• Title/Summary/Keyword: Thermal loads

Search Result 601, Processing Time 0.029 seconds

COMPARISON OF NEUTRONIC BEHAVIOR OF UO2, (TH-233U)O2 AND (TH-235U)O2 FUELS IN A TYPICAL HEAVY WATER REACTOR

  • MIRVAKILI, SEYED MOHAMMAD;KAVAFSHARY, MASOOMEH ALIZADEH;VAZIRI, ATIYEH JOZE
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.315-322
    • /
    • 2015
  • The research carried out on thorium-based fuels indicates that these fuels can be considered as economic alternatives with improved physical properties and proliferation resistance issues. In the current study, neutronic assessment of $UO_2$ in comparison with two $(Th-^{233}U)O_2$, and $(Th-^{235}U)O_2$ thorium-based fuel loads in a heavy water research reactor has been proposed. The obtained computational data showed both thorium-based fuels caused less negative temperature reactivity coefficients for the modeled research reactor in comparison with $UO_2$ fuel loading. By contrast, $^{235}U$-containing thorium-based fuel and $^{235}U$-containing thorium-based fuel loadings in the thermal core did not drastically reduce the effective delayed neutron fractions and delayed neutron fractions compared to $UO_2$ fuel. A provided higher conversion factor and lower transuranic production in the research core fed by the thorium-based fuels make the fuel favorable in achieving higher cycle length and less dangerous and costly nuclear disposals.

Sensitivity Study on Creep Behaviors of RPV under Severe Accident conditions (중대사고 조건하의 원자로용기 크리프 거동 민감도 분석 연구)

  • Kim, Tae Hyun;Chang, Yoon-Suk;Kim, Min-Chul;Lee, Bong-Sang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.1
    • /
    • pp.61-68
    • /
    • 2017
  • Reactor pressure vessel (RPV) under severe accident conditions accompanied by core melting is exposed to direct high-temperature thermal loads. Understanding the creep behavior of the material is one of the most important factors for evaluating the structural integrity at these conditions. While damage evaluation studies have been conducted on critical structures of nuclear power plants through finite element (FE) analyses considering creep behavior, for accurate creep damage evaluation, constitutive equations considered in the FE analyses may have different results depending on the time hardening and strain hardening models as well as the tertiary creep consideration. The purpose of this study is to evaluate the creep damage under severe accident conditions by using FE method for a representative domestic RPV material, SA508 Gr.3. The effect of material hardening models and constitutive equations which are the main variables were also investigated.

Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method (건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석)

  • Park, Jaejoong;Myeong, Jemin;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

Study on characteristics of board prepared by microwave drying process of coal bottom ash and vermiculite (바텀애쉬를 이용한 흡음 내장재 개발에 관한 연구)

  • Jun, Hyun Chul;Kim, Geug Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.3
    • /
    • pp.135-142
    • /
    • 2017
  • In this study, we prepared the board of vermiculite materials utilizing coal bottom ash from the Western thermal power stations in Korea and obtained experimental data in applications for building interior materials with the characteristics of sound absorption. To produce the mixture materials of vermiculite and coal bottom ash, we used a microwave drying process. In addition, a ball milling process was used to produce particles of coal bottom ash with a uniform size of $65{\mu}m$. When the board made from mixture materials of vermiculite and coal bottom ash were produced with bottom ash sulfur concentrations of 5, 10 wt%, maximum bending loads were analyzed. These experimental results would contribute much to fundamental data essential to the recycling technology of coal bottom ash.

Analysis of Steady Heat Conduction for Rubber Pads of a Tank Track Subjected to Dynamic Loading (동적하중을 받는 궤도차량 고무패드의 정상 열전도 해석)

  • Kim, Hyung-Je;Kim, Byung-Tak
    • Elastomers and Composites
    • /
    • v.36 no.3
    • /
    • pp.153-161
    • /
    • 2001
  • The rubber pads era tank which undergo dynamic deformations with the sufficient amplitudes and frequencies lead to a considerable internal temperature rise due to the heat generation. The heat generation which is dependent on the viscoelastic characteristics or a rubber is due to the conversion of partial mechanical energy into thermal energy identical to the area oi hysteresis loop. Heat generation without adequate heat dissipation leads to heat build-up and the excessive temperature rite exerts a bad influence upon the performance and the life of rubber products. In this paper, temperature distributions of the rubber pads of a tank track subjected to dynamic loads are obtained under the assumption of the steady state. Heat generation rates used in this finite element analysis are acquired through experiments and the computed temperature fields are displayed in isothermal contour regions.

  • PDF

Performance Prediction of Geothermal Heat Pump System by Line-Source and Modified DST(TRNVDSTP) Models (선형열원 모델과 수정 DST(TRNVDSTP) 모델에 의한 지열 히트펌프 시스템 성능 예측)

  • Sohn, Byong-Hu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.61-69
    • /
    • 2012
  • Geothermal heat pump(GHP) systems have been shown to be an environmentally-friendly, efficient alternative to traditional cooling and heating systems in both residential and commercial applications. Although some experimental work related to performance evaluation of GHP systems with vertical borehole ground heat exchangers for commercial buildings has been done, relatively little has been reported on the performance simulation of these systems. The aim of this study is to evaluate the cooling and heating performance of the GHP system with 30 borehole ground heat exchangers applied to an commercial building($1,210m^2$) in Seoul. For this purpose, a typical design procedure was involved with a combination of design parameters such as building loads, heat pump capacity, circulating pump, borehole diameter, and ground effective thermal properties, etc. The cooling and heating performance prediction of the system was conducted with different prediction methods and then each result is compared.

A Study on the Internal Flow Patterns and Heat Transfer Characteristics for a Cylindrical Rotating Heat Pipe (원통형 회전 히트파이프의 내부 유동 및 열전달 특성에 관한 연구)

  • Lee, Jin Sung;Lee, Jae Jun;Kim, Chul Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1217-1228
    • /
    • 1998
  • In order to elucidate the operational characteristics of rotating heat pipes, the internal flow patterns and heat transfer performance are investigated. Flow patterns and its transition are studied with various rotational speeds by visualizing flows established inside a rotating tube. To verify those results of analysis, 2 heat pipes of the same geometries but fill charge rates of 7, 30% were manufactured and submitted to operating tests. Comparison of experimental results on heat transfer rate show a fairly good agreement with the analytical results. The analysis reveals that the optimum charge ratio is ranged in 4~7% depending on the quantity of thermal loads. but the heat pipe with 7% of fill charge ratio reached dry-out limitation at heat flux of $q^{{\prime}{\prime}}=6.2kW/m^2$ lower than that of analytic results. Transition of flow regime was well related to the correlation by Semena & Khmelev on transient centrifugal Froude Number Frc. But hysteresis phenomenon was observed in transition of flow regime, when the rotational speed was stepwisely changed in the way to undergo 1 cycle.

An Experimental Study on the Performances of a Coupled Reactor with Catalytic Combustion and Steam Reforming for SOFC and MCFC (SOFC와 MCFC에 적용하기 위한 촉매연소-수증기 개질이 통합된 반응기의 성능에 관한 실험적 연구)

  • Ghang, Taegyu;Kim, Yongmo;Lee, Sangmin;Ahn, Kookyoung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.4
    • /
    • pp.364-377
    • /
    • 2014
  • The performances of a coupled reactor in which a steam reformer and a catalytic combustor were mounted simultaneously had been investigated and compared. The combustible offgas exhausted from the anode of SOFC and MCFC were utilized as heat sources for the endothermic steam methane reforming. The catalytic combustion was used in order to burn the combustible offgas. Thermal energy released by the catalytic combustion is directly transferred to the reformer surrounding the combustor. The various operational conditions such as fuel utilization rate, steam to carbon ratio, amount of catalysts, fuel cell loads were changed. And operating variables were comprehensively identified by sensitivity analysis. The fundamental results from this experimental study show the potential abilities of the coupled reactor. Therefore the results will be of help to design and manufacture the more better coupled reactor in the future.

Prediction of the Strength and Vibration Safety of the 30ton Thrust Turbopump Turbine by Finite Element Analysis (30톤 추력급 터보펌프 터빈의 구조 강도 및 진동 해석을 통한 안정성 예측)

  • Yoon, Suk-Hwan;Jeon, Seong-Min;Lee, Kwan-Ho;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.5 s.26
    • /
    • pp.20-28
    • /
    • 2004
  • Static and dynamic structural analyses of a turbine bladed-disk for a liquid rocket turbopump are performed to investigate the safety level of strength and vibration at design point. During operation, turbopump is exposed to various external loads. Therefore, the effects of them should be carefully considered and properly modeled. First, due to the high rotational speed of the turbopump, effects of centrifugal forces are considered in the structural analysis. Thermal load caused by severe temperature differences is also considered. A three dimensional finite element method (FEM) is used for linear and nonlinear structural analyses with modified Newton-Raphson iteration method. After the nonlinear solution is obtained from the structural analysis, dynamic characteristics are obtained as a function of rotational speed from the linearized eigenvalue analysis at an equilibrium position. From the analysis results, characteristics of stress distribution and vibration were thoroughly examined and investigated.

Calculation of Active Power Transfer Capability using Repeated Power Flow Program

  • Ham, Jung-Pil;Kim, Jung-Hoon;Lee, Byung-Ha;Won, Jong-Ryul
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.15-19
    • /
    • 2002
  • The power transfer capability is determined by the thermal, dynamic stability and voltage limits of the generation and transmission systems. The voltage stability depends on the reactive power limit and it affects the power transfer capability to a great extent. Then, in most load flow analysis, the reactive power limit is assumed as fixed, relatively different from the actual case. This paper proposes a method for determining the power transfer capability from a static voltage stability point of view using the IPLAN which is a high level language used with PSS/E program. The f-V curve for determining the power transfer capability is determined using Repeated Power Flow method. It Is assumed that the loads are constant and the generation powers change according to the merit order. The maximum reactive power limits are considered as varying similarly with the actual case and the effects of the varied maximum reactive power limits to the maximum power transfer capability are analyzed using a 5-bus power system and a 19-bus practical power system.