• 제목/요약/키워드: Thermal insulation shutter

검색결과 2건 처리시간 0.016초

단열셔터를 적용한 구동창호의 에너지 절감 및 야간 난방성능 분석 (Analyses of Energy Savings and Night Heating Performance of a Movable Thermal Insulation Shuttered Window)

  • 이장만;조수;임상훈;송규동
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.150-155
    • /
    • 2013
  • Usually, a window tends to have a lower thermal performance, than that of an ordinary wall. This study analyzes the enhancement of thermal performance of a window, when a Thermal Insulation Shutter is installed. The analyses were conducted at the laboratory, and with a full-scale mockup house, and the U-factor and heating load were examined. The laboratory results show that the U-factor increased by approximately 28%, when a Thermal Insulation Shutter was installed. The temperature difference was about $5^{\circ}C$, and this shows that the Thermal Insulation Shutter enhances the thermal performance of the window, when installed. The mockup house was used to calculate the heating load; the heating load was reduced by more than 41%, and shows that the installation of a Thermal Insulation Shutter is an effective way to reduce heating energy consumption.

단열 셔터의 기밀성능 및 단열성능 확보를 위한 Azon 및 Azo-Core의 적용성 평가 (Evaluation of the Applicability of Azon and Azo-Core for Enhancing Airtightness and Thermal Insulation Performance of Insulated Shutters)

  • 길민우;김규용;최병철;지성준;윤혜영;남정수
    • 한국건축시공학회지
    • /
    • 제24권4호
    • /
    • pp.437-445
    • /
    • 2024
  • 본 연구는 창호에 사용되고 있는 Azon과 Azo-Core를 셔터에 활용하여 단열성능을 확보하고자 Therm 7.4 프로그램과 기밀, 단열성 시험을 통해 검토하였다. 시뮬레이션 결과 Azon 및 Azo-Core는 기존의 단열재에 비해 단열성이 우수했으며 셔터에 적용 시 1등급의 기밀성능과 평균2.018W/m2·k의 열관류율을 확인하였다. 이는 외부셔터 설치 기준 중부지방 1.5W/m2·k, 남부지방 1.8W/m2·k보다 높은 수치이지만 제주지방 2.2W/m2·k에는 적용 가능한 수치이며 Azon과 병행 적용이 아닌 Azo-Core만 적용할 수 있는 추가 연구가 검토된다면 셔터 단열재로 사용 가능성이 있다.