• Title/Summary/Keyword: Thermal front

Search Result 308, Processing Time 0.023 seconds

Thermoelastic effect on inter-laminar embedded delamination characteristics in Spar Wingskin Joints made with laminated FRP composites

  • Mishra, P.K.;Pradhan, A.K.;Pandit, M.K.;Panda, S.K.
    • Steel and Composite Structures
    • /
    • v.35 no.3
    • /
    • pp.439-447
    • /
    • 2020
  • This paper presents two sets of full three-dimensional thermoelastic finite element analyses of superimposed thermo-mechanically loaded Spar Wingskin Joints made with laminated Graphite Fiber Reinforced Plastic composites. The study emphasizes the influence of residual thermal stresses and material anisotropy on the inter-laminar delamination behavior of the joint structure. The delamination has been pre-embedded at the most likely location, i.e., in resin layer between the top and next ply of the fiber reinforced plastic laminated wingskin and near the spar overlap end. Multi-Point Constraint finite elements have been made use of at the vicinity of the delamination fronts. This helps in simulating the growth of the embedded delamination at both ends. The inter-laminar thermoelastic peel and shear stresses responsible for causing delamination damage due to a combined thermal and a static loading have been evaluated. Strain energy release rate components corresponding to the Mode I (opening), Mode II (sliding) and Mode III (tearing) of delamination are determined using the principle of Virtual Crack Closure Technique. These are seen to be different and non-self-similar at the two fronts of the embedded delamination. Residual stresses developed due to the thermoelastic anisotropy of the laminae are found to strongly influence the delamination onset and propagation characteristics, which have been reflected by the asymmetries in the nature of energy release rate plots and their significant variation along the delamination front.

An Experimental Assessment of the Effects of Residual Stresses on Fracture Behavior of the Plate (압축잔류응력이 판의 파괴 특성에 미치는 영향에 관한 실험적 평가)

  • Jang, Chang-Doo;Park, Yong-Kwan;Song, Ha-Cheol;Kim, Byung-Il
    • Journal of Navigation and Port Research
    • /
    • v.26 no.4
    • /
    • pp.435-440
    • /
    • 2002
  • The quantitative assessment of the effect of the residual stress on fracture behavior was executed by some experiment and numerical analysis. First of all, artificial residual stresses were imposed on CT(Compact Tension) specimens by local heating using gas torch, and an appropriate distribution of residual stresses was obtained by thermal elastic-plastic FE analysis. To certify the result of the FE analysis, an experimental measurement was performed in accordance with ASTM standard. Fracture toughness test was executed on the several types of specimens. The first type was the specimen without residual stresses, and the others had different peak value of compressive residual stress at crack front via controlling the heat flux. All the test results were presented on th J resistance(JR) curves and discussed to verify the effect of compressive residual stresses on fracture behavior.

Thermal Flow Characteristics of Impinging Air Jet by Shape of Turbulence Promoter (난류촉진체 형상에 의한 충돌제트의 열유동 특성)

  • Kum, Sungmin;Jho, Shigie;Yu, Byeonghun;Lee, Seungro
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.187-193
    • /
    • 2012
  • In this study, it was experimentally investigated the effect of the clearances distance between the rod and the impinging plate on characteristics of the thermal flow. For the heat transfer enhancement of wall jet region, the right triangle and the square rods were arranged in front of the impinging plate with various clearance distances. As results, the heat transfer enhancement rate of potential core region at H/B=2 was higher than that of transition region at H/B=10. In this experiment range, the maximum heat transfer enhancement rate was about 46 % higher at the square rod with H/B=2 and C=1mm compared with the flat plate. The heat transfer enhancement rate of the right triangle rod was on average about 3 to 8 % higher than that of the square rod, regardless of the clearance.

Analyzing Flow Variation and Stratification of Paldang Reservoir Using High-frequency W ater Temperature Data (고빈도 수온 자료를 이용한 팔당호의 성층과 흐름 변화 분석)

  • Ryu, In-Gu;Lee, Bo-Mi;Cho, Yong-Chul;Choi, Hwang-Jeong;Shin, Dong-Seok;Kim, Sang-Hun;Yu, Soon-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.392-404
    • /
    • 2020
  • The focus of this study was to quantify the thermal stratification and analyze the relationship between the stratification structure and the tributaries to understand flow variations in the Paldang Reservoir. The vertical distribution of the temperature and density gradients, and the depth and thickness of the thermocline were quantitatively calculated using a lake physics tool (rLakeAnalyzer) and high-frequency monitoring data. Based on a density gradient of 0.2 kg/㎥/m, the thermocline was formed from mid-May to early-September 2019 and the other periods were weakly stratified or mixed. The thickness of the thermocline was developed until 4.7 m and the depth of the thermocline was formed at a depth of 3 - 6 m at the front of the Paldang Reservoir. During the formation of the thermocline, the Namhangang and Gyeongancheon tributaries with relatively high water temperature (low-density) flowed into the upper layer of the reservoir, and the Bukhangang tributary with low water temperature (high-density) mainly affected the lower layer of the reservoir. This is because the density currents were formed due to the difference in the water temperature of the tributaries. The findings of this study may be used for constructing high-frequency monitoring and quantitative data analyses of reservoirs.

A Case Study of Heavy Snowfall with Thunder and Lightning in Youngdong Area (뇌전을 동반한 영동지역 대설 사례연구)

  • Kim, Hae-Min;Jung, Sueng-Pill;In, So-Ra;Choi, Byoung-Choel
    • Atmosphere
    • /
    • v.28 no.2
    • /
    • pp.187-200
    • /
    • 2018
  • The heavy snowfall phenomenon with thunder and lightning occurred in Yeongdong coastal region on 20 January 2017. Amount of snow on that day was a maximum of 47 cm and was concentrated in a short time (2 hours) at the Yeongdong coastal area. The mechanism of thundersnow was investigated to describe in detail using observational data and numerical simulation (Weather Research and Forecast, WRF) applied lightning option. The results show that a convective cloud occurred at the Yeongdong coastal area. The east wind flow was generated and the pressure gradient force was maximized by the rapidly developed cyclone. The cold and dry air in the upper atmosphere has descended (so called tropopause folding) atmospheric lower layer at precipitation peak time (1200 LST). In addition, latent heat in the lower atmosphere layer and warm sea surface temperature caused thermal instability. The convective cloud caused by the strong thermal instability was developed up to 6 km at that time. And the backdoor cold front was determined by the change characteristics of meteorological elements and shear line in the east sea. Instability indexes such as Total totals Index (TT) and Lightning Potential Index (LPI) are also confirmed as one of good predictability indicates for the explosive precipitation of convective rainfall.

Study on Reaction Characteristics and Catalysts to Reform Diesel for Production of Hydrogen (수소생산을 위한 디젤 개질용 촉매와 반응특성에 관한 연구)

  • Kang, In-Yong;Bae, Joong-Myeon
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.1
    • /
    • pp.12-16
    • /
    • 2005
  • Diesel is one of the best hydrogen systems, which has very high volumetric density $[kg\;H_2/m^3]\;(>100)\;and\;gravimetric\;density[\%\;H_2]\;(>\;15)$Several catalysts were selected for diesel reforming. 3 catalysts of our group (NECS-1, NECS-2, NECS-3) and 2 commercial catalysts (Sud-Chemie, Inc, FCR-HCl4, FCR-HC35) were used to reform diesel. NECS-1 showed the best performance to reform diesel. In addition to these results, we studied on reaction characteristics for better understanding about auto thermal reforming of diesel by investigating product gas concentrations and temperature Profiles along the catalyst bed. We found technological issues such as fuel delivery and thermal configuration between front exothermic part and rear endothermic part.

A Study on the interface of information processing system on Human enhancement fire fighting helmet (휴먼 증강 소방헬멧 정보처리 시스템 인터페이스 연구)

  • Park, Hyun-Ju;Lee, Kam-Yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.497-498
    • /
    • 2018
  • In the fire scene, it is difficult to see 1m ahead because of power failure, smoke and toxic gas, even with thermal imaging camera and Xenon searchlight. Analysis of the smoke particles in the fire scene shows that even if the smoke is $5{\mu}m$ or less in wavelength, it is difficult to obtain a front view when using a conventional thermal imaging camera if the visual distance exceeds 1 meter. In the case of black smoke with a particle wavelength of $5{\mu}m$ or more, a space permeation sensor technology using various sensors other than a single sensor is required because chemical materials, gas, and water molecules are mixed. Firefighters need a smoke detection technology for smoke detection and spatial information visualization for forward safety view.In this paper, we design the interface of the information processing system with 32bit CPU core and peripheral circuit. We also implemented and simulated the interface with Lidar sensor. Through this, we provide interface that can implement information processing system of human enhancement fire helmet in the future.

  • PDF

Effect of Thermal Imidization and Curing on Fluorescence Behavior of a Phenylethynyl-Terminated Poly(amic acid)

  • Cho, Donghwan;Yang, Gyeongmo;Drzal, Lawrence T.
    • Macromolecular Research
    • /
    • v.11 no.5
    • /
    • pp.297-302
    • /
    • 2003
  • The imidization and cure reaction of a thermosetting phenylethynyl-terminated amic acid (LaRC PETI-5) in film form have been monitored as a function of temperature by means of a steady-state fluorescence technique using a front-face illumination method. The variation of the fluorescence emission spectra of LaRC PETI-5 can be divided into four temperature regions; Region I: below 15$0^{\circ}C$, Region II: 150-25$0^{\circ}C$, Region III: 250-35$0^{\circ}C$, and Region IV: above 35$0^{\circ}C$. The fluorescence spectra in Region I are largely influenced by residual N-methyl-2pyrrolidinone in the polymer and also slightly by partial imidization of the polymer. There is a combined effect of imidization and solvent removal on the fluorescence behavior in Region II. The spectra in Regions III and IV are due significantly to the cure reaction of LaRC PETI-5 and to a post-cure effect of the polyimide, respectively. This spectroscopic evidence indicating the transformation of the amic acid imide oligomer into the corresponding polyimide via imidization and cure, agrees well with thermal analysis results obtained previously. The intermediate stage of cure in the range of 250-30$0^{\circ}C$ predominantly influences the change of the fluorescence intensity. The later stage above 30$0^{\circ}C$ significantly influences the position of the spectrum. This fluorescence study also supports the mechanism proposed in earlier work that the crosslinking reaction takes place at the reaction sites in the conjugated polyene and the phenylethynyl end group in the polyimide chain.

A Study on Behavior Pattern and Physiological Changes during Bathing and Showering (목욕 및 샤워시 행동패턴 및 생리적 변화에 대한 연구)

  • Jeong W.W.;Rhee K.;Park K.R.;Chun K.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.256-259
    • /
    • 2005
  • Analysis of behavior pattern and thermal response during bathing and showering provides important fundamental data when developing an automatic bathing/showering system. The behavior pattern and physiological changes during bathing/showering were measured und analyzed for the aged male group. We recorded the volunteers showering at front, back, left and right view using four CCTV cameras in order to study the behavior pattern during showering. The photographic data were analyzed by counting the frequencies of body contact and identifying zones where hands could reach. In order to study the thermal response, we measured the blood pressure (B.P), heart rate (H.R), body temperature (B.T.), breathing rate (B.R) for the different water temperatures and the locations of immersion for the young and old age groups. The results showed that the frequencies of body contacts were varied for different body sections. Also there were some body sections where hands could not be reached because of reduced pliability and muscular strength of the aged group. But we observed rather uniform body contact frequencies when a towel was used. In partial immersion bath experiments, we observed the changes of B.P. H.R and B.T in the case of young and old age groups, and the changes were more significant in the young age group.

  • PDF

Non Destructive Technique for Steel Corrosion Detection Using Heat Induction and IR Thermography (열유도 장치와 적외선 열화상을 이용한 철근부식탐지 비파괴 평가기법)

  • Kwon, Seung Jun;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.40-48
    • /
    • 2012
  • Steel corrosion in concrete is a main cause of deterioration and early failure of concrete structures. A novel integration of electromagnetic heat induction and infrared (IR) thermography is proposed for nondestructive detection of steel corrosion in concrete, by taking advantage of the difference in thermal characteristics of corroded and non-corroded steel. This paper focuses on experimental investigation of the concept. An inductive heater is developed to remotely heat the embedded steel from concrete surface, which is integrated with an IR camera. Concrete samples with different cover depths are prepared. Each sample is embedded with a single rebar in the middle, resulting an identical cover depth from the front and the back surfaces, which enable heat induction from one surface and IR imaging from the other simultaneously. The impressed current (IC) method is adopted to induce accelerated corrosion on the rebar. IR video images are recorded during the entire heating and cooling periods. The test results demonstrate a clear difference in thermal characteristics between corroded and non-corroded samples. The corroded sample shows higher rates of heating and cooling than those of the non-corroded sample. This study demonstrates a potential for nondestructive detection of rebar corrosion in concrete.