• 제목/요약/키워드: Thermal energy performance

검색결과 1,938건 처리시간 0.033초

태양열 시스템에 적용된 나선재킷형 축열조의 CFD 해석 (CFD Analysis for Spiral-Jacketed Thermal Storage Tank in Solar Heating Systems)

  • 남진현;김민철;김찬중;홍희기
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.645-653
    • /
    • 2008
  • Spiral-jacketed thermal storage tanks can greatly simplify solar heating systems while maintaining the thermal performance at a similar level as conventional systems with an external heat exchanger. Proper design of the spiral-jacket flow path is essential to make the most of solar energy, and thus to maximize the thermal performance. In the present work, computational fluid dynamics (CFD) analysis was carried out for a spiral-jacketed storage tank installed in a solar heating demonstration system. The results of the CFD analysis showed a good agreement with experimentally determined thermal performance indices such as the acquired heat, collector efficiency, and mixed temperature in the storage tank. This verified CFD modelling approach can be a useful design tool in optimizing the shape of spiral-jacket flow path and the flow rate of circulating fluid for better performance.

BTES 방식의 계간축열 시스템을 적용한 유리온실의 난방용 태양열시스템의 경제성 평가 (Economic Evaluation of Glass Greenhouse Heating Solar Thermal System Applied with Seasonal Borehole Thermal Energy Storage System)

  • 박상미;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.63-74
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a 1,320 m2 glass greenhouse was analyzed numerically, and the economic feasibility depending upon the number of boreholes was evaluated. For this study, the gardening 16th and 19th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And the heating load of the glass greenhouse selected was 1,147 GJ. BTES(Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The number of boreholes was selected from 25 to 150. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modelling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump and controller. As a result of the analysis, when the number of boreholes was from 25 to 50, the thermal efficiency of BTES system and the solar fraction was the highest. When the number of boreholes was from 25 to 50, it was analyzed that the payback period was from 5.2 years to 6.2 years. Therefore it was judged to be the number of boreholes of the proposed system was from 25 to 50, which is the most efficient and economical.

국내 최대 경사면일사량 분석 (Analysis of Maximum Solar Radiation on Inclined Surfaces in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.3-7
    • /
    • 2009
  • The amount of incident rays over inclination according to direction has been widely utilized as important data in installing solar thermal systems. To optimize the incident solar radiation, the slope, that is the angle between the plane surface in question and the horizontal, and the solar azimuth angles are needed for these solar thermal systems. This is because the performance of the solar thermal systems in much affected by angle and direction of incident rays. Recognizing that factors mentioned above are of importance, actual experiment on the moving route of the sun have been performed in this research to obtain the angle of inclination with which the maximum incident rays can be absorbed. After all, the standard for designing highly optimized solar thermal systems will be provided for designers and employees working in the solar collector related industries.

  • PDF

비유리식(nonglass) 진공관의 진공도가 집열판의 열적 특성에 미치는 영향 (Effect of Vacuum in a Non-glass Vacuum Tube on the thermal behavior of the Absorber Plate)

  • 오승진;현준호;김남진;이윤준;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.67-73
    • /
    • 2008
  • This study has been carried out to investigate the effect of vacuum on the thermal performance of a nonglass evacuated tube. A series of measurements are made indoors to monitor the temperature change of the absorber plate contained in the evacuated tube under different conditions of vacuum and heat fluxes. Those temperatures measured at the thermal equilibrium could be used to assess the heat losses to the ambient in link with the steady operation of non-glass evacuated tubes for solar exploitation.

Inactivation of Airborne E. coli and B. subtilis Bioaerosols Utilizing Thermal Energy

  • Lee, Yun-Ha;Lee, Byung-Uk
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권11호
    • /
    • pp.1684-1689
    • /
    • 2006
  • Airborne microorganisms, which are currently termed bioaerosols, have received attention owing to the harmful effects they have on human health. As the concern over airborne microorganisms grows, there also grows an urgent need to study and develop efficient methods for controlling them. In this study, thermal energy using a thermal tube was tested as a control method, mainly against airborne E. coli. For a comparison, B. subtilis var. niger spores were utilized in the experimentation. It was found that the widely known inactivation conditions for microorganisms were not adequate against airborne microorganisms. The experimental results demonstrated the need for extensive studies that should investigate adequate and economic conditions to control against airborne bacteria. In this study, thermal energy exposed by the thermal tube demonstrated an inactivation performance for controlling E. coli bioaerosols.

국내 태양열시스템 설치를 위한 시스템 최적 설치각 산출을 통한 최대 경사면일사량 분석 (Analysis of Maximum Solar Radiation on Inclined Surfaces for the Installation of Solar Thermal Systems in Korea Using the Optimum Installation Angle)

  • 조덕기;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.47-54
    • /
    • 2009
  • The amount of incident rays over inclination according to direction has been widely utilized as important data m installing solar thermal systems. To optimize the incident solar radiation, the slope, that is the angle between the plane surface in question and the horizontal, and the solar azimuth angles are needed for these solar thermal systems. This is because the performance of the solar thermal systems in much affected by angle and direction of incident rays. Recognizing that factors mentioned above are of importance, actual experiment on the moving route of the sun have been performed in this research to obtain the angle of inclination with which the maximum incident rays can be absorbed. After all, the standard for designing highly optimized solar thermal systems will be provided for designers and employees working in the solar collector related industries.

The applicability study and validation of TULIP code for full energy range spectrum

  • Wenjie Chen;Xianan Du;Rong Wang;Youqi Zheng;Yongping Wang;Hongchun Wu
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4518-4526
    • /
    • 2023
  • NECP-SARAX is a neutronics analysis code system for advanced reactor developed by Nuclear Engineering Computational Physics Laboratory of Xi'an Jiaotong University. In past few years, improvements have been implemented in TULIP code which is the cross-section generation module of NECP-SARAX, including the treatment of resonance interface, considering the self-shielding effect in non-resonance energy range, hyperfine group method and nuclear library with thermal scattering law. Previous studies show that NECP-SARAX has high performance in both fast and thermal spectrum system analysis. The accuracy of TULIP code in fast and thermal spectrum system analysis is demonstrated preliminarily. However, a systematic verification and validation is still necessary. In order to validate the applicability of TULIP code for full energy range, 147 fast spectrum critical experiment benchmarks and 170 thermal spectrum critical experiment benchmarks were selected from ICSBEP and used for analysis. The keff bias between TULIP code and reference value is less than 300 pcm for all fast spectrum benchmarks. And that bias keeps within 200 pcm for thermal spectrum benchmarks with neutron-moderating materials such as polyethylene, beryllium oxide, etc. The numerical results indicate that TULIP code has good performance for the analysis of fast and thermal spectrum system.

CPV 냉각용 열분산기 모듈의 열성능에 관한 실험적 연구 (Experimental Investigation on the Thermal Performance of a Heat Spreader Module for the CPV Cooling)

  • 도규형;한용식;최병일;김명배
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.95-102
    • /
    • 2011
  • In this paper, the thermal performance of a heat spreader module for CPV(Concentrating Photovoltaic) cooling is experimentally investigated. In order to evaluate the thermal performance of the heat spreader module which consists of a Metal PCB and an aluminum alloy heat spreader, experiments are conducted with varying the type of the metal PCB, the thickness of the heat spreader, the inclination angle, and the applied heat flux. To validate the experimental data, three dimensional numerical simulations are performed using the commercial simulation tool in the present work. The experimental results are compared with the corresponding numerical results and are in close agreement with the numerical results. From the experimental results, the temperature difference between the maximum temperature and the ambient temperature increases with decreasing the thickness of the heat spreader and with increasing the applied heat flux. Also, it is found that the inclination angle significantly affects the thermal performance of the heat spreader. the maximum temperature difference of the heat spreader with the horizontal orientation is much larger than that with the vertical orientation.

열전도도 저감 기반의 열전소재 성능 증대 전략 수립을 위한 수식적 이해 (Formulaic Understanding to Make a Strategy of Thermal Conductivity Reduction for Enhancing the Performance of Thermoelectric Materials)

  • 피지희;최명식;이규형
    • 마이크로전자및패키징학회지
    • /
    • 제29권4호
    • /
    • pp.89-94
    • /
    • 2022
  • 고체상태에서 열에너지과 전기에너지를 직접적이고 가역적으로 변환할 수 있는 열전소재는 전기전도특성인 전기전도도 및 제벡계수와 열전도특성인 열전도도에 의해 그 성능이 결정된다. 하지만 전기전도도, 제벡계수, 열전도도는 소재의 조성, 결정구조 및 전자구조에 의해 결정되며, 서로 상관관계를 나타내기 때문에 성능 증대를 위한 효과적인 전략수립에 어려움이 있다. 본 논문에서는 열전소재의 성능과 관련한 수식에 대한 이해를 바탕으로 실험 결과와 연계하여 열전도도 저감 관점에서 효과적인 결함제어 기반 열전소재 성능 증대 전략을 수립할 수 있는 방법론을 제공하고자 한다.

이중관형 지중열교환기 구성에 따른 현장 열성능 평가 (Evaluation on in-situ Thermal Performance of Coaxial-type Ground Heat Exchanger with Different Configurations)

  • 이석재;정현석;오광근;박상우;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.8-15
    • /
    • 2019
  • In order to design coaxial-type Ground Heat Exchangers (GHEXs) efficiently, the effect of components (i.e, heat exchange pipe and grouting material) on the thermal performance of coaxial-type GHEXs should be identified in advance. In this paper, three coaxial-type GHEXs with different configurations were constructed in a test bed. Then, the effect of heat exchange pipes and grouting materials on the thermal performance of coaxial-type GHEXs was investigated by performing in-situ thermal response tests (TRTs) and thermal performance tests (TPTs). In the TRTs, the effective thermal conductivities of the coaxial-type GHEXs with concrete grouting and STS pipes were improved by 6.15 and 22.7%, respectively compared to those of bentonite grouting and HDPE pipes. Additionally, in the TPTs, the use of concrete grouting and STS pipes in the coaxial-type GHEXs enhanced the in-situ thermal performance by 15 and 33.8%, respectively.