• 제목/요약/키워드: Thermal effect

Search Result 6,965, Processing Time 0.035 seconds

Effect of silica fume content in concrete blocks on laser-induced explosive spalling behavior

  • Seong Y. Oh;Gwon Lim;Sungmo Nam;Byung-Seon Choi;Taek Soo Kim;Hyunmin Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.1988-1993
    • /
    • 2023
  • This experimental study investigated the effect of silica fume mixed in concrete blocks on laser-induced explosion behavior. We used a 5.3 kW fiber laser as a thermal source to induce explosive spalling on a concrete surface blended with and without silica fume. An analytical approach based on the difference in the removal rate and thermal behavior was used to determine the effect of silica fume on laser-induced explosive spalling. A scanner was employed to calculate the laser-scabbled volume of the concrete surface to derive the removal rate. The removal rate of the concrete mixed with silica fume was higher than that of without silica fume. Thermal images acquired during scabbling were used to qualitatively analyze the thermal response of laser-induced explosive spalling on the concrete surface. At the early stage of laser heating, an uneven spatial distribution of surface temperature appeared on the concrete blended with silica fume because of frequent explosive spalling within a small area. By contrast, the spalling frequency was relatively lower in laser-heated concrete without silica fume. Furthermore, we observed that a larger area was removed via a single explosive spalling event owing to its high porosity.

Effect of Thermal Contact Resistance on Transient Thermoelastic Contact for an Elastic Foundation (탄성기반에서 과도 열탄성 접촉에 대한 열 접촉 저항의 영향)

  • Jang Yong-Hoon;Lee Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.7 s.250
    • /
    • pp.833-840
    • /
    • 2006
  • The paper presents a numerical solution to the problem of a hot rigid indenter sliding over a thermoelastic Winkler foundation with a thermal contact resistance at constant speed. It is shown analytically that no steady-state solution can exist for sufficiently high temperature or sufficiently small normal load or speed, regardless of the thermal contact resistance. However the steady state solution may exist in the same situation if the thermal contact resistance is considered. This means that the effect of the large values of temperature difference and small value of force or velocity which occur at no steady state can be lessened due to the thermal contact resistance. When there is no steady state, the predicted transient behavior involves regions of transient stationary contact interspersed with regions of separation regardless of the thermal contact resistance. Initially, the system typically exhibits a small number of relatively large contact and separation regions, but after the initial transient, the trailing edge of the contact area is only established and the leading edge loses contact, reducing the total extent of contact considerably. As time progresses, larger and larger numbers of small contact areas are established, unlit eventually the accuracy of the algorithm is limited by the discretization used.

Human Solar Heat Load and Thermal Comfort in an Outdoor Environment (건축외부공간에 있어서 인체의 일사열부하(日射熱負荷) 및 열적(熱的) 쾌적성(快適性)에 관한 실험적 연구)

  • Jeong, Chang-Won;Yoon, In
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.1 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • The purpose of this paper is to investigate the mount of relief of human solar heat load and thermal comfort in outdoor environment in summer, Six different types of sites, T garden and its neighboring area in Japan, were selected as the experiment sites. The experiments were conducted from 22 to 29 August, 1994 to find the relationship between climatic conditions and human responses, Climatic conditions, subjects's thermal sensation and skin temperature were measured. Radiant heat exchange on the human body was estimated on the basis of the measured air and surface temperature and solar radiation. Thermal index Operative Temperature and New Effective Temperature was modified with the effect of the radiant heat exchange. Human thermal comfort and skin temperature is affected by the solar radiation and the sky factor in an outdoor environment. The effect of tree shade was verified on thermal comfort, The mount of relief of human solar heat load is relation to the existence of shade a solar radiation and the sky factor. The urban garden is one of the effective design element in an urban environmental planning.

  • PDF

Effect of enzyme treatment on the DSC and TGA behavior of silkworm powder

  • Jo, You-Young;Bae, Sung Min;Kim, HyunBok;Lee, Kwang Gill;Kweon, HaeYong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.37 no.1
    • /
    • pp.29-32
    • /
    • 2018
  • Silkworm powder's thermal property is an important factor for its storage and marketing. This study examined the effect of edible enzyme on the thermal property of silkworm powder using Thermogravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC). Results of the TGA showed that regardless of the enzyme treatment, the weight loss patterns of silkworm powders exhibited 3 step thermal property deterioration at approximately $80^{\circ}C$, $280^{\circ}C$, and $480^{\circ}C$ due to water evaporation and thermal degradation. This is similar with the DSC which also resulted in all samples two endothermic peaks attributed also to water evaporation and thermal degradation. These results indicated that the use of enzyme such as protease and cellulase might not affect significantly the thermal properties of silkworm powder.

A Study on the Improvement of Thermal Environment by a method using thermometers and computer simulations on the Atrium (실측 분석기법과 시뮬레이션 분석 기법에 의한 아트리움 열환경 개선에 관한 연구)

  • Lee, So-Yeun;An, Jung-Soo;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.28-34
    • /
    • 2009
  • The atrium in the building has many advantages including its aesthetic and functional effect. But the upper part of the atrium has the thermal problem of overheating due to insolation through the window. But natural ventilation aided buoyancy effect can be a solution to make comfortable indoor environment. Proper design of openings is very important to improve thermal environment in the atrium. In this study, thermal evaluations were performed to improve thermal environment in the atrium. Indoor thermal environment of an atrium at Seoul was measured in the field and simulated with Computational Fluid Dynamics( CFD) code. The turbulent flow model adopted is $K-{\varepsilon}$ model. The results of computer simulations are compared with the measurements at the point in the atrium. In order to improve the indoor ventilation environment of the atrium, thermal environment evaluations of six alternatives were conducted. After evaluations of the results, the design guidelines of an atrium are suggested.

A Comparative Study About the Effect of Nonablative Laser and Thermal energy on Rabbit Knee Joint Capsular Properties (비융해성 LASER 및 열에너지의 가토 슬관절막에 대한 영향 비교)

  • Byun Ki-Yong;Rhee Kwang-Jin;Lee Jun-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2001
  • Purpose: To evaluate the histologic effect(LM and EM findings)of nonablative LASER and thermal energy on knee joint capsule of rabbit. Material and Methods: The nonablative LASER and thermal energy was applied to the rabits(average age 36 weeks, weight 5 ㎏). There were divided into 4 groups with 6 rabbits in each. The group I received 6 watts of LASER, group Ⅱ 12 watts of LASER, group Ⅲ 60° of thermal energy, and group Ⅳ 70° of thermal energy. The histologic study included H-E, Massons trichrome stain and electron microscopy at immediate, 3 weeks and 6 weeks after operation. Results: The histologic finding in immediate after operation was shown a fibrous degeneration of collagen on all groups and related to the energy level. The histologic finding after 3 weeks showed fibrosis and this fibrosis related the level of energy. Especially the group IV was shown flattening of capsule and deep fibrosis. The histologic finding after 6 weeks was shown marked recovery of collagen arrangement and capillary proliferation in group Ⅰ,Ⅱ and Ⅲ. But in the group Ⅳ not recovered. Conclusion: The nonablative LASER or thermal energy can cause degeneration, fibrosis and contracture of joint capsular collagen.

  • PDF

Evaluation of Effect on Thermal Fatigue Life Considering TGO Growth (TGO 성장이 열피로 수명에 미치는 영향 평가)

  • Song, Hyunwoo;Lee, Jeong-Min;Kim, Yongseok;Oh, Chang-Seo;Han, Kyu Chul;Lee, Young-Ze;Koo, Jae-Mean;Seok, Chang-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.12
    • /
    • pp.1155-1159
    • /
    • 2014
  • Thermal barrier coating (TBC) which is used to protect the substrate of gas turbine is exposed to high temperature environment. Because of high temperature environment, thermally grown oxide (TGO) is grown at the interface of thermal barrier coating in operation of gas turbine. The growth of TGO critically affects to durability of TBC, so the evaluation about durability of TBC with TGOs of various thickness is needed. In this research, TGO was inserted by aging of TBC specimen to evaluate the effect of the TGO growth. Then thickness of TGO was defined by microstructure analysis, and thermal fatigue test was performed with these aging specimens. Finally, the relation between thermal fatigue life and the TGO growth according to aging time was obtained.

Numerical Study on the Thermal Entrance Effect in Miniature Thermal Conductivity Detectors (소형 Thermal Conductivity Detector의 입구열전달 거동에 대한 수치해석)

  • Kim, U-Seung;Kim, Yeong-Min;Chen, Kuan;Cheon, Won-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.439-447
    • /
    • 2002
  • The microchannel flow in miniature TCDs (thermal conductivity detectors) is investigated numerically. The solutions based on the boundary layer approximation are not very accurate in the region of the duct inlet for low Reynolds numbers. In this study, two-dimensional Navier-Stokes equations are considered to analyze the gas flow in a miniature TCD. Effects of channel size, inlet and boundary conditions on the heat transfer rate are examined. When the gas stream is not preheated, the distances for a miniature TCD to reach the conduction-dominant region for duct flow are found to be approximately two and three times the thermal entry length for duct flow with constant properties, respectively, leer constant wall temperature and constant wall heat flux boundary conditions. If the gas temperature at the channel inlet is close to the mean gas temperature in the conduction-dominant region, the entrance region is much shorter compared to other cases considered in this study.

Studies on the Thermal Resistant Spore of Bacillus coagulance(Part I Sporulating Conditions of the Thermal Resistant spore) (Bacillus coagulance 의 내열성포자에 관한 연구 (제일보) 생육ㆍ내열성및 포자형성에 미치는 단양조건)

  • 유주현;최규봉;이정치;윤원영
    • Microbiology and Biotechnology Letters
    • /
    • v.5 no.1
    • /
    • pp.5-12
    • /
    • 1977
  • As a basic study for the application of the spore-tearing lactic acid bacteria to foods, the effects of the sporulating conditions on the growth and sporogenesis were studied were observed. The results obtained are as follow. 1. All carbohydrates added to sporulation media except dextrin decreased the sporulation rate and the thermal resistance of spores. Dextrin stimulated the growth, however, there in no effect on the thermal resistance. 2. As nitrogen source, the protein hydrolysates such as peptone, casamino acid were effective to obtain were spores of the increased thermal resistance. 3. Ca$\^$++/, Mn$\^$++/ of the metal ions added to casamino acid containing medium validly increased the total growth, sporulation rate and thermal resistance. Its optimum concentration was 40 ppm each. 4. Biotin of vitamines had an effect on the total growth, sporulation and thermal resistance of spores. Its optimum concentration was 30${\gamma}$/ml. 5. The resistant spores required the adequate maturation period, more than 36 hours, sufficient aeration. and optimum temperature, 37∼45$^{\circ}C$.

  • PDF