• Title/Summary/Keyword: Thermal and electrical degradation

Search Result 223, Processing Time 0.034 seconds

Reliablity of Distributed Feedback Laser Diodes for High-speed Optical Communication Systems (고속 광통신 시스템용 비대칭 분포귀환형 레이져 다이오드의 신뢰성에 관한 연구)

  • Jeon, Su-Chang;Joo, Han-Sung;Yun, Il-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.96-99
    • /
    • 2005
  • As the demand of internet networks using backbone communication systems recently increased, the researches on the high-speed wideband optical communication systems are required. For high-speed optical communication systems, asymmetric sampled grating distributed feedback laser diodes (DFB-LDs) are developed and the reliability of DFB-LDs is examined. The reliability of DFB-LDs is performed by monitoring I-V and L-I characteristics and two degradation phenomena related to the electrical characteristics of LDs are observed during the life tests. The first degradation phenomenon by increasing the reverse current is considered as a formation of leakage current path enough to prevent lasing operation in lateral blocking layer near active region of lasers. The second degradation phenomenon by decreasing the forward current is considered as activation of non-radiative Auger recombination process by thermal energy and the second degradation phenomenon is recovered after the off-test period at room temperature Eventually, evaluating the reliability of DFB LDs can allow us to improved the manufacturability in high-volume manufacturing.

  • PDF

Analyses on Electrical-Mechanical Characteristics of Environment-friendly Transformer Insulating Material by Accelerated Thermal Aging (가속 열 열화에 따른 환경친화형 변압기 절연물의 전기적-기계적 특성 분석)

  • Shim, Myeong-Seop;An, Jung-Sik;Choi, Sun-Ho;Jeong, Jung-Il;Lee, Tae-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1832-1838
    • /
    • 2010
  • Aging of transformer insulating material in natural ester insulating oil is compared to that in conventional transformer oil. Aging of insulating paper and insulating oil have been studied by performing accelerated thermal aging test. Sealed aging test vessels containing cooper, laminated core, Kraft paper and insulating oil(natural oil or mineral oil) were aged at $140^{\circ}C$ for 500, 1000, 1500 and 2000 hours. Insulating oils after aging are investigated with total acid number, breakdown voltage and viscosity. Also, degradation of insulating paper after aging is determined using breakdown voltage and mechanical strength. Accelerated aging studies demonstrate a slower aging rate for natural ester insulating oil compared to the rate for conventional mineral oil.

Degradation characteristics of ITO thin film deposited by RF magnetron sputter (RF 마그네트론 스퍼터로 증착시킨 ITO 박막의 열화 특성에 관한 연구)

  • 김용남;박정현;신현규;송준광;이희수
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.234-234
    • /
    • 2003
  • Indium tin oxide(ITO) is an advanced ceramic material with many electronic and optical applications due to its high electrical conductivity and transparency to light ITO thin films are used in transparent electrodes for display devices, transparent coatings for solar energy heat mirrors and windows films in n-p heterojunction solar cells, etc. Almost all display devices were fabricated on transparent ITO electrode substrates. There are several factors that cause decay in the efficiency and the failure of display devices. The degradation or damage of ITO is one of the main factors. Under normal operating conditions, the electric fold required for the operation of display devices is very high As a high electric field induces the joule heat, the degradation of the ITO thin film may be expected. Therefore, it is worthy to investigate the thermal and electrical effect on ITO thin films.

  • PDF

Lifetime-Temperature Rise Model for the Evaluation of Degradation in Electric Connections/Contacts (전기적 접속/접촉부 열화 평가를 위한 수명 온도상승 모델)

  • Kim, Jeong-Tae;Kim, Nam-Jun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this paper, 'lifetime-temperature rise model' based on the 'lifetime-resistance model' is theoretically Proposed, in order to find out the evaluation method of degradation and the residual lifetime by use of infrared image camera for electric connections/contacts. Two assumptions have been builded up for the 'lifetime-temperature rise model': one is associated with the linear relationship between the temperature ism ΔK and contact resistance, and the other the functional relationship between the temperature of electric connections/contacts and the operating time presenting in the 'lifetime-resistance model'. To prove the proposed model, experiments have been performed for various electric connections/contacts. From the experimental results, measured values were quite similar to the calculated values, which proved the above-mentioned two assumptions. Therefore, by use of 'lifetime-temperature rise model', it is possible to estimate the trend of degradation and the residual lifetime for electric connections/contacts through the temperature measurements .

Dielectric Relaxation Properties for following the Ageing of Polyetheretherketone (열화에 따른 Polyetheretherketone의 유전완화특성)

  • Kim, Ki-Yup;Lee, Chung;Ryu, Boo-Hyung;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.396-403
    • /
    • 2004
  • The dielectric properties of Y-ray irradiated and thermally aged polyetheretherketone (PEEK) have been investigated. Results of the temperature dependency of dielectric properties indicated that the glass transition temperature of aged PEEK increased as radiative and thermal ageing. The frequency dependency of dielectric properties implied that the magnitude of radiation and thermal induced dipoles, ions increased as radiative and thermal ageing. The values of relaxation intensity calculated using Cole-Cole's circular arc can be useful for evaluation of degradation level of PEEK.

The Improvements for Fire Retardancy and Radiation Resistance of Chloroprene Rubber (클로로프렌 고무의 난연성 및 내방사선 특성 향상)

  • Kim, Ki-Yup;Lee, Chung;Ryu, Boo-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1205-1211
    • /
    • 2004
  • This study has investigated radiation degradation of chloroprene rubber in the presence of some fire retardant. Ammonium polyphosphate, aluminium trihydroxide, magnesium hydroxide, calcium carbonate and antimony trioxide were selected as flame retardant. Samples were irradiated using a Co$^{60}$ ${\gamma}$ -ray and ray up to 2000 kGy at a dose rate of 5 kGy/hr in the presence of air atmosphere at room temperature. After irradiation, samples were assessed fire retardancy with electrical properties and mechanical properties. Some considerations concerning the effects of the fire retardants added to chloroprene rubber on the radiation and thermal stability of chloroprene rubber are presented. From fire retardancy with electrical and mechanical property measurements, it was found that addition of magnesium hydroxide resulted in maximum fire retardant effect.

Evaluation of Radiation Degradation or Crosslinked Polyethylene using TGA (TGA를 이용한 가교폴리에틸렌의 방사선 열화 평가)

  • Lee, Chung;Kim, Ki-Yup;Ryu, Boo-Hyung;Lim, Kee-Joe
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.50-55
    • /
    • 2003
  • Radiation degradation of crosslinked polyethylene(XLPE) was investigated using thermogravimetric analysis(TGA), The results of TGA were compared with FT-IR, melting temperature, oxidation induction time, and elongation at break on the XLPE exposed by $\gamma$-ray. 5% decomposition temperature of $\gamma$-ray irradiated XLPE showed similar tendencies with the case of elongation at break. Both properties agreed below 1000 KGy, however, did not show any remarkable characteristics above 1000 kGy, these properties can be useful to evaluate the radiation degradation of XLPE for only low irradiated region. Above 1000 kGy, the thermal decomposition activation energy showed decreased, on the contrary, increasing below 1000 kGy. Compared with FT-IR spectrum of irradiated XLPE, it was confirmed that the oxidation reaction was still occurring below 1000 kGy. Radiation degradation of XLPE was dependent upon the irradiation doses, TGA can be a useful tool to evaluate the degradation.

Effect of Thermal Aging on Electrical Properties of Low Density Polyethylene

  • Wang, Can;Xie, Yaoheng;Pan, Hua;Wang, Youyuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2412-2420
    • /
    • 2018
  • The thermal degradation of low density polyethylene (LDPE) will accelerate the production of carbonyl groups (C=O), which can act as the induced dipoles under high voltage. In this paper, we researched the dielectric properties and space charge behavior of LDPE after thermal aging, which can help us to understand the correlation between carbonyl groups (C=O) and electrical properties of LDPE. The spectra results show that LDPE exhibit obvious thermooxidative reactions when the aging time is 35 days and the productions mainly contain carboxylic acid, carboxylic eater and carboxylic anhydride, whose amount increase with the increasing of aging time. The dielectric properties show that the real permittivity of LDPE is inversely proportional to temperature before aging and subsequently become proportional to temperature after thermal aging. Furthermore, both the real and imaginary permittivity increase sharply with the increasing of aging time. The fitting results of imaginary permittivity show that DC conductivity become more sensitive about temperature after thermal aging. On this basis, the active energies of materials calculated from DC conductivity increase first and then decrease with the increasing of aging time. In addition, the space charge results show that the heterocharges accumulated near electrodes in LDPE change to the homocharges after thermal aging and the mean volume charge density increase with the increasing of aging time. It is considered that the overlaps caused by electrical potential area is the main reason for the increase of DC conductivity.

Effects of Heat Treatment on Electrical and Mechanical Properties of Glass Fiber Reinforced Epoxy (열처리가 유리섬유 강화 복합재료의 전기적 및 기계적 성질에 미치는 영향)

  • 이백수;이덕출
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.3
    • /
    • pp.174-180
    • /
    • 1998
  • In this work, the properties of FRP, which is applied recently in the composite insulating materials, by thermal treatment were investigated. The specimens were epoxy glass laminates fabricated by thermal press method and had the volume content of 46[%] cutted $45^{\circ}C$ in the fiber direction and 1.0[mm] thickness. The experimental results showed that the amount of weight loss, wettability, surface potential, and surface resistivity increased up to 200[$^{\circ}C$] as a function of temperature. Usually, most degradations caused the hydrophilic to decrease the contact angle. But, in this work on thermal-degradated FRP, we can confirm the introduction of hydrophobic properties by cross-linking and the ablation of polar small-molecules rather than chain scission and oxidation. Finally, weight loss and contact angle increased. These phenomena show the existence of hydrophobic surface. With the change to the hydrophobic surface and the electrical potential and resistivity on FRP surface increased. But, the dielectric properties and tensile stength are decreased.

  • PDF

A Study on Optimal Design According to Change of Coil Distribution in Slot Less Type Permanent Magnet Synchronous Motor (소형 Slot less PMSM의 coil 배치에 따른 최적 설계 및 열 내구성 분석)

  • Kim, Yong-Tae;Go, Duk-Hwa;Gim, Gyu-Hwa;Baek, Sung-Min;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.27-32
    • /
    • 2017
  • In this paper, slot less type high-speed and compact motor was designed. it was selected through change of stator coil distribution for the optimal performance of the motor. In this paper, designed motor was expected to be very vulnerable to heat dissipation in a compact motor. Therefore, to ensure reliability in the design result, winding and permanent magnet damage caused by the losses of motor was analyzed by thermal analysis and demagnetization analysis. Using the result, whether motor burnout was confirmed by motor performance degradation and insulation breakdown.