• 제목/요약/키워드: Thermal and electrical degradation

검색결과 223건 처리시간 0.024초

대형 터빈 발전기용 고정자 권선의 1000 thermal cycle 후 전기적 특성 변화 (Electrical Degradation of Stator Bars for Large Turbine Generator after 1000 Thermal Cycles)

  • 강명국;김태희;이재권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.975-976
    • /
    • 2007
  • Thermal and mechanical stresses, caused by repetitive start and stop and load fluctuation during long time operation, on winding stator bars are one of the main causes for electrical degradation of insulating materials. To understand the degradation process, we manufactured bar specimens with the same processes that make generator winding stator bars and the specimens were subjected to various degrees of thermal cycling. Measurements of the insulation properties, such as dissipation factor, tip-up and partial discharge, for un-aged specimens and for specimens aged by thermal cycling at 50, 100, 250, 500 and 1000 thermal cycles were performed. Finally all specimens were tested to obtain electrical breakdown voltages. In this paper we present the data and electrical degradation analysis results obtained during this program.

  • PDF

가속 열열화 시험에 의한 고정자 형권 코일의 절연특성에 관한 연구 (A Study on the Insulation Properties for Stator Form-wound Winding by Thermal Degradation Test)

  • 채승훈;김상걸;오현석;신철기;왕종배;김기준;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.115-118
    • /
    • 2000
  • In case of developing new motor, many examinations was tested to decide a motor efficiency and reliability. To give reliability judgment, traction motor winding insulation was tested by electrical method after appling electrical, heat, mechanical, environmental stress. In this study, stator form-wound winding of traction motor in urban transit E.M.U was tested by accelerative thermal degradation test. Stator form-wound winding was tested on the accelerative degradation composed of heat, vibration, moisture, overvoltage and researched insulation resistance, dielectric loss, partial discharge for insulation degradation properties, evaluated withstand voltage. Degradation temperature was $230[^\circ{C}]$, $250[^\circ{C}]$, $270[^\circ{C}]$, for stator form-wound winding respectively. On the test results of accelerative thermal degradation, insulation properties were relied all temperature until 10 times and expected life was evaluated by the rule of reducing $10[^\circ{C}]$ life into halves. Expected life was 31.8 years. It is guaranteed insulation reliability because of exceeding 25 years life times as considering.

  • PDF

열열화된 PVC 케이블의 부분방전 진단 (Partial Discharge Diagnosis of Thermal Degradated PVC Cable)

  • 송기태;이성일
    • 한국전기전자재료학회논문지
    • /
    • 제24권3호
    • /
    • pp.208-214
    • /
    • 2011
  • In this thesis, the partial discharge according to applied voltage and variations of cross-sectional area and length of the conductor related to general condition for using cable was measured in order to study degradation diagnosis for 2-Core cable of the PVC insulator used in industrial fields for other safety installations. Also the thermal degradation conditions under various installation circumstances of cables were studied by assuming degradation conditions with each different degradation rate (50%, 67%, 100%) such as variation in degradated temperature, thermal exposure time, normal state, partially degradated state and overall degradated state for thermal degradation diagnosis. The quantity of electric discharge (V-Q) according to applied voltage was measured for measurement of inception voltage and extinction voltage. The quantity of electric discharge and the number of electric discharge (Q-N) were measured with applied voltage kept constantly. In addition, pictures were taken using SEM (scanning electron microscope) to compare the surface of external insulator to degradated state of internal insulator according to thermal degradation temperature and also compare the surface of external insulator to degradated surface state of internal insulator according exposure time of cables to thermal stress.

열 열화에 의한 폴리에틸렌 테레프탈레이트 필름의 전기 특성에 관한 연구 (A Study on Electricity Properties of Polyethylene Terephthalate Film due to Thermally Degradation)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제30권11호
    • /
    • pp.693-698
    • /
    • 2017
  • In this study, the thermal degradation properties of polyethylene terephthalate film has been examined by the capacitance, Tan ${\delta}$, thermography, FTIR, and SEM results at temperatures of $90{\sim}170^{\circ}C$ and frequencies of 0.3~3,000 kHz. It was found that the capacitance decreased with increasing thermal imaging temperature, probably caused by weakening of chemical bond with increasing temperature. Tan ${\delta}$ decreased upon increasing temperature from $90^{\circ}C$ to $170^{\circ}C$, probably due to the molecular motion of COOH radical or OH radical. The FT-IR measurement reveals that no structural change of the material occurs upon thermal radiation. The SEM measurement shows that the material is stabilized by thermal decomposition with increasing temperature; however, excessive thermal degradation obstructs the stabilization of the material.

배전용 ZnO 피뢰기 소자의 열적/전기적 파라미터 분석에 관한 연구 (A study on analysis of thermal and electrical parameters of the ZnO arrester block)

  • 이복희;이수봉;이승주;전병욱;김동성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.353-356
    • /
    • 2007
  • This paper presents the thermal and electrical characteristics of ZnO arrester blocks under the AC voltages. The leakage currents of ZnO arrester blocks were measured as a function of time. The temperature distributions of ZnO arrester blocks were observed by the forward looking infrared camera The degradation and thermal runaway of ZnO arrester blocks were closely related with the temperature limit of ZnO arrester blocks which decided heat generation and dissipation As a result, the degradation and thermal runaway of ZnO arrester blocks depend on the temperature and leakage current of ZnO arrester blocks.

  • PDF

전력용 피뢰기의 열안정화 특성 (Study on Thermal Stability Characteristics of Surge Arrester for High Power)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1142-1145
    • /
    • 2004
  • ZnO surge arresters continuously endure the operating voltages during the operation course, and in the mean time, which need to withstand occasionally transient voltages of lightning and switching overvoltages. Under these voltages, the ZnO varistors inside arresters would have aging phenomena, one important result of aging phenomena is the increasing of resistive currents of varistors, which leads to the increasing of power losses of varistors. And the operating voltage is continuously applied on the ZnO varistors, there is a degradation phenomenon existing in ZnO varistors. When the degradation reaches a certain degree, then the arrester must stop operation. The degradation is related to the applied voltage ratio, the applied voltage ratio is high, the degradation is quickly. When the power loss is higher than the thermal dispersion ability of house of arrester, then the arrester will thermally breakdown. In this study the thermal stability characteristics of surge arresters for high power wil be discussed on the view point of watt losses and thermal breakdown.

  • PDF

Lifetime Assessment for Oil-Paper Insulation using Thermal and Electrical Multiple Degradation

  • Kim, Jeongtae;Kim, Woobin;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.840-845
    • /
    • 2017
  • In this paper, in order to investigate the lifetime of oil-paper insulation, specimens were artificially aged with thermal and electrical multiple stresses. Accelerated ageing factors and equivalent operating years for each aging temperatures were derived from results of tensile strengths for the aged paper specimens. Also, the evaluation for the multi-stress aged specimens were carried out through the measurement of impulse breakdown voltage at high temperature of $85^{\circ}C$. The lifetimes of the oil-paper insulations were calculated with the value of 66.7 for 1.0 mm thickness specimens and 69.7 for 1.25 mm thickness specimens throughout the analysis of impulse BD voltages using equivalent operating years, which means that dielectric strengths would not be severely decreased until the mechanical lifetime limit. Therefore, for the lifetime evaluation of the oil-paper insulation, thermal aging would be considered as a dominant factor whereas electrical degradation would be less effective.

열화 시간 변화에 따른 폴리카보네이트 필름의 유전 특성에 관한 연구 (A Study on Dielectric Properties of Polycarbonate Film Due to Variation of Degradation Time)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제31권7호
    • /
    • pp.469-474
    • /
    • 2018
  • In this study, the capacity and FTIR of polycarbonate film that was degraded for 2, 4, and 8 h in a thermostat at $180^{\circ}C$ was measured. The results of this study are as follows. It was found that the capacity decreased with increasing degradation time and frequency. This findings suggest that the attraction between molecules and amorphous polycarbonate increased because it contains the ketone group (-C=O-) and the chain of dioxides group (-O-R-O-). Measurement by FTIR found that the time of thermal degradation has a smaller impact because the transmutation or variation of the material does not occur. Measurement by SEM magnified 1,000 times found that a longer thermal degradation time results in thermal decomposition of the specimen's particles.

열 열화에 따른 변압기 절연물의 절연특성 분석 (Analysis of Insulation Characteristics for Transformer Insulating Materials According to Thermal Degradation)

  • 이민구;심재명;임경범;이대동
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1688-1693
    • /
    • 2016
  • In this study shall investigate the influence upon the electrical property of transformer oil due to the heat among accelerated heat degradation experiment for a constant hour in the typical insulation oils of mineral base oil, silicon base oil and vegetable oil. In addition, the electric insulation performance of insulation materials in transformer shall be evaluated through the electric property analysis according to the heat degradation of epoxy insulation material, which has been used for electric facilities such as a molded transformer.

열철리에 따른 Epoxy 복합재료의 표면 소수성증가에 관한 해석 (Analyses on the Increment of Surface Hydrophobicity of Epoxy Composites by Thermal Treatment)

  • 임경범;이백수;정무영;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권4호
    • /
    • pp.153-160
    • /
    • 2001
  • In order to analyze the degradation process of epoxy/glass fiber for outdoor condition, FRP laminate was exposed to high temperature. Then, the degradation process was evaluated by comparing contact angle, surface potential, surface resistivity, and XPS. The experimental results showed that the amount of weight loss, contact angle, surface potential and surface resistivity increased up to 200 $^{\circ}C$ as a function of temperature. These phenomena show the existence of hydrophobic surface. With the change to the hydrophobic surface and the electrical potential and resistivity on FRP surface increased. In XPS to analyze surface chemical structures, the increased hydrophobicity in thermal increase of unsaturated double bond in carbon chains. Aslo, thermal treatment caused the discoloration on the point of treated surface. These phenomena were attributed to the generations of ether group.

  • PDF