• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.033 seconds

Analysis of Heavy Metal Concentration on Working Clothes for Waste Incinerating Workers (생활폐기물 소각장 작업복의 중금속 분석)

  • Park, Soon-Ja
    • The Korean Journal of Community Living Science
    • /
    • v.18 no.1
    • /
    • pp.39-53
    • /
    • 2007
  • The purpose of this study was to determine the characteristics of an experimental protective clothing material with regard to comfort and isolation from the hazardous heavy metals produced in municipal waste incineration. An analysis was conducted on the total concentrations of heavy metals in some parts such as surface, middle layer, and interior for the treated fabric, and the untreated one, and working clothes. We conclude that the processed fabric with charcoal for working clothes showed the least exposure to heavy metals of the three. Working clothes worn by workers during waste incineration were much more contaminated than the untreated and treated materials. The material of working clothes could be chosen according to the function with regard to its original chemical characteristics, which are the proper results of the dyeing process. The processed fabric material has high degrees of moisture regain, thermal insulation, water vapor penetration, and antibacterial function; consequently, it is much more comfortable to wear. The fabric material proposed in this research contributed much more to blocking heavy metal concentrations (such as Cd, Pb, Cu, Cr, Zn, Mn) than did the fabric of working clothes at present. Consequently, we strongly suggest that the material of working clothes be upgraded by adopting the above-mentioned charcoal-processed fabric. Materials of working clothes must be improved to increase comfort and prevent harmful gas, flying dust, and heavy metals from permeating the fabrics.

  • PDF

Analysis of Response of a Wind Farm During Grid/inter-tie Fault Conditions (그리드/연계선 사고 시 풍력발전단지의 응동 분석)

  • Lee, Hye-Won;Kim, Yeon-Hee;Zheng, Tai-Ying;Lee, Sang-Cheol;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1128-1133
    • /
    • 2011
  • In a wind farm, a large number of small wind turbine generators (WTGs) operate whilst a small number of a large generator do in a conventional power plant. To maintain high quality and reliability of electrical energy, a wind farm should have equal performance to a thermal power plant in the transient state as well as in the steady state. The wind farm shows similar performance to the conventional power plant in the steady state due to the advanced control technologies. However, it shows quite different characteristics during fault conditions in a grid, which gives significant effects on the operation of a wind farm and the power system stability. This paper presents an analysis of response of a wind farm during grid fault conditions. During fault conditions, each WTG might produce different frequency components in the voltage. The different frequency components result in the non-fundamental frequencies in the voltage and the current of a wind farm, which is called by "beats". This phenomenon requires considerable changes of control technologies of a WTG to improve the characteristics in the transient state such as a fault ride-through requirement of a wind farm. Moreover, it may cause difficulties in protection relays of a wind farm. This paper analyzes the response of a wind farm for various fault conditions using a PSCAD/EMTDC simulator.

Performance Analysis of a Triple Pressure HRSG

  • Shin, Jee-Young;Son, Young-Seok;Kim, Moo-Geun;Kim, Jae-Soo-;Jeon, Yong-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1746-1755
    • /
    • 2003
  • Operating characteristics of a triple pressure reheat HRSG are analyzed using a commercial software package (Gate Cycle by GE Enter Software). The calculation routine determines all the design parameters including configuration and area of each heat exchanger. The off-design calculation part has the capability of simulating the effect of any operating parameters such as power load, process requirements, and operating mode, etc., on the transient performance of the plant. The arrangement of high-temperature and intermediate-temperature components of the HRSG is changed, and its effect on the steam turbine performance and HRSG characteristics is examined. It is shown that there could be a significant difference in HRSG sizes even though thermal performance is not in great deviation. From the viewpoint of both economics and steam turbine performance, it should be carefully reviewed whether the optimum design point could exist. Off-design performance could be one of the main factors in arranging components of the HRSG because power plants operate at various off-design conditions such as ambient temperature and gas turbine load, etc. It is shown that different heat exchanger configurations lead to different performances with ambient temperature, even though they have almost the same performances at design points.

A Study on Temperature Characteristics of KSTAR PFC and Vacuum Vessel at Baking Phase (KSTAR PFC와 진공용기의 가열탈리 단계에서의 온도특성에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Young-Jin;Jung, Nam-Yong;Kim, Kyung-Min;Lee, Je-Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.158-168
    • /
    • 2015
  • To create an ultra-high vacuum state at the KSTAR, the temperature of plasma facing component and vacuum vessel should be maintained at $300^{\circ}C$ and $110^{\circ}C$ respectively at a baking phase. The purpose of this research is obtaining the target baking temperatures. Experiments were performed to investigate the temperature characteristics of PFC and VV at the baking phase. Thermal network analysis was used to find heat transfer rates among PFC, VV and other components, and this analysis was verified by using the experimental data. The required heating energy of the PFC and the heating and cooling energy of the VV for the target baking temperatures were found to be 346 kW, 28 kW, and 136 kW, respectively.

A Study on the Vibration Behavior of Composite Laminate under Tensile Loading by ESPI (ESPI에 의한 인장하중 하에서의 복합재 적층판의 진동 거동에 관한 연구)

  • Yang, Seung-Pil;Kim, Koung-Suk;Jung, Hyun-Chul;Chang, Ho-Seob;Kim, Chong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.516-521
    • /
    • 2000
  • Most of studies, using ESPI method, have handled tension, thermal and vibration analysis, and is limited to isotropic materials. However, tension and vibration simultaneously are loaded in real structure. Also, almost study using ESPI method is locally limited to the analysis on the isotropic materials and a few studies on the anisotropic materials have reported. Existing methods, such as the accelerometer method and FEA method, to analyze vibration have some disadvantages. Using the accelerometer method that is generally used to analyze vibration phenomena, it is impossible to analyze vibration on the oscillating body and one can observe no vibration mode shape during experiment. In case of the FEA method, it is difficult to define boundary conditions correctly if the shape of a body tested is complex, and one can just obtain vibration mode shapes on the peak amplitude in each modes. In this study, plane plate of stainless steel(STS304), isotropic material, that is used as structural steel is analyzed about vibration characteristics under tension. Also, in the study of stainless steel, the characteristics of composite material(AS4/PEEK) used as high strength structural material in aircraft is evaluated about vibration under tension, and studies the effect of tension on vibration.

  • PDF

Occupant Characteristics Analysis based on Integrative IEQ Weighting Factor in Residential Buildings - Based on Occupant Survey of Residential Building in Chungbuk Province (주거건물에서의 통합 실내환경평가 가중치 분석을 통한 거주자 특성분석 - 충북지역 주거건물 거주자 설문조사를 바탕으로)

  • Yoon, Sung-Hoon;Yun, Hee-Jin
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The objective of this research is to investigate and analyze the relationship between physical residential conditions and occupants' responses in apartment buildings by POE(Post-Occupancy Evaluation). The analysis results from this research will help to identify the indoor residential problems and find design solutions for improving overall residential indoor residential environment. Method: The occupant survey was conducted at four different apartment complex area at Cheongju City, Chungbuk Province, Korea. Combination of unbalanced indoor environmental conditions in residential building had difference of occupants' responses according to occupants' characteristics, such as gender, age, and so on. The survey collected data regarding the occupants' EQ(Environmental Quality) priorities to determine the weight of each environmental-quality factor (lighting, acoustic, thermal and indoor air quality). A paired comparison method was used to determine the weight by comparing the relative importance of the two factors based on occupant's survey response. Result: The output from this research is useful to understand the residential environment, occupants' satisfaction, preference, and identifies the current residential problems and finds an architectural solution in apartment buildings.

Analysis of Induction Heating according to Coil Shapes on the V-groove Weld Joint (V-groove를 가진 모재에서 코일 형상에 따른 유도가열 해석)

  • Ahn, Soo Deok;Cho, Young Tae;Jung, Yoon Gyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.2
    • /
    • pp.167-172
    • /
    • 2015
  • In order to prevent crack in thick weld zones, the preheating process such as induction and gas torch heating needs to be applied. Among them induction heating is the most effective heat source because it has rare thermal effect and very rapid heating characteristics. In this paper, when the induction heating method is used to improve arc welding, the temperature distribution and magnetic field density of the welding zones are analyzed by simultaneously solving heat transfer and electromagnetic field equation. In particular, cone and flat type coils are designed and induction heating effects of each type are compared to identify heating characteristics on a V-groove weld joint. As a result, a cone shape coil is more efficient in the preheating process. When induction heating and arc welding system is designed for thick plate with V-groove weld joint, the results in this paper could be applied.

Recycling of Sound Insulation Headliner Waste Material (흡음재 폐기물의 재활용 방안)

  • Hong, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.3089-3095
    • /
    • 2013
  • The headliner was made of polyurethane(PU) and glass fiber(GF) composite materials are widely used as a sound insulation material. A large amount of waste materials occurs as a by-product in the headliner manufacturing process. In order to efficiently reuse the headliner waste materials, separation process of the components are very necessary. According to the results of thermal analysis, weight loss showed increase in the order polyurethane foam> non-foaming polyurethane> non-woven fabric> 1st layer> glass fiber in the range of up to $400^{\circ}C$. Analysis of the DSC characteristics, HDPE, LLDPE, PP, and Master Batch by adding additives the wasted scrap. As a result, except for the PP, there was no exothermic transition due to the crystallization.

A Characteristics of Environmental Fraternitive Photopolymerization and Thermal Degradation on Methyl Methacrylate (메틸메타크릴레이트의 환경친화적인 광중합 및 열분해특성)

  • 주영배;이내우;최재욱;강돈오;설수덕
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.68-75
    • /
    • 2001
  • Photopolymerization, the utilization of electromagnetic radiation(or light) as the energy source for polymerization of functional monomers, oligomers is the basis of important commercial processes with broad applicability, including photoimaging and RV curing of coatings and inks. The objective of this study is to investigate the characteristics of environmental fraternitive photopolymerization of methyl methacrylate(MMA). This work is the first step to continue further research about alkyl methacrylate. The experiment was done in aqueous solution under the influence of photo-initiator concentration(0.05-0.25mol/l), light intensity (5000-9000 ${\mu}J/cm^2$) and monomer concentration(2-6mol/l). Methyl methacrylate was polymerized to high conversion ratio using hydrogen peroxide($H_2O_2$) and the kinetics model we have obtained is as follows. $R_p=k_p[S]^{0.41}[M]^{0.62}[L]^{2.45} exp(53.64/RT$). The differential method of thermogravimetric analysis(Friedman method) was used to obtain value of activation energy on decomposition reaction. The average value of it res 45.4Kca1/mol.

  • PDF

A Study on the Flow Characteristics according to the Shapes of Rod on Impinging Jet by PIV Measurement (충돌 Jet에서 Rod 형상에 따른 유동특성의 PIV 계측에 의한 연구)

  • 나우정;정진도;송민근;이상범;손승우;주은선
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.152-161
    • /
    • 2004
  • The thermal load is a very important problem to be solved in many industrial systems including the electronic equipment. Impinging Jets have been known to provide a large heat transfer rates on surface for many years. The turbulence enhancement of fluid flow is requested for the efficiency elevation of heat transfer. A study on flow fields by rods attached to the wall surface as a promoter of turbulence enhancement has been carried out. The exact analysis on chracteristics of impinging jet field is requested to obtain the optimum design of the impinging jet system. By visualizing the flow field and processing the high digital image by computer PIV can afford exact data on the velocity vector kinetic energy and turbulence intensity in the complex turbulence field. In this study. three kinds of rod shape such as square. triangle. and semicircle are selected as the turbulence promoter. Nozzle diameters are 10mm. 17mm. and 23mm. And the analysis of the flow characteristics due to the above rods is carried out at Re No. 2.000, 3.000. and 4,000 by PIV measurement. It is clarified that the rod setup is very useful to obtain the turbulence enhancement and the turbulence intensity according to the shapes of rod appears large in order of the shapes of rod such as square 〉 triangle 〉semicircle.