• Title/Summary/Keyword: Thermal Transfer Analysis

Search Result 1,366, Processing Time 0.028 seconds

Thermal Analysis of Wall/Floor Intersections in Building Envelope

  • Ihm, Pyeongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.97-107
    • /
    • 2004
  • Wall/floor intersection is important parts of a building envelope system. These intersections can be sources of thermal bridging effects and/or moisture condensation problems. This paper provides a detailed analysis of the thermal performance of wall/floor intersection. In particular, two-dimensional steady-state and transient solutions of the heat conduction within the wall/floor joint are presented. Various insulation configurations are considered to determine the magnitude of heat transfer increase due to wall/floor joint construction.

MATRIX형 세라믹 열교환기 코아의 열전단 및 열응력해석 (The Heat Transfer and Thermal Stress Analysis on the Ceramic Core of the Matrix-type Recuperator)

  • 박용환;우창수
    • 연구논문집
    • /
    • 통권24호
    • /
    • pp.151-159
    • /
    • 1994
  • The heat transfer and thermal stress analysis was performed on the ceramic core of the matrix-type recuperator. The efficiency was calculated as 34% to 65%. Triple-pass arrangement provided higher preheated air temperatures, lower thermal stresses and the increase of pressure drops. Higher temperature gradients and maximum peak stresses appeared on the corners of the ceramic core. The effect of boundary conditions was significant and the use of spring-load sealing mechanism could release thermal stresses.

  • PDF

동시 축·방열 조건에서 PCM의 열전달 특성에 관한 연구 (A Study on the Characteristic of Heat Transfer of PCM(Phase Change Material) at the Simultaneous Charging and Discharging Condition)

  • 이동규;박세창;정동열;강채동
    • 설비공학논문집
    • /
    • 제28권8호
    • /
    • pp.305-310
    • /
    • 2016
  • A thermal storage systems was designed to correspond to the temporal or quantitative variation in the thermal energy demand, and most of its heat is stored using the latent and sensible heat of the heat storage material. The heat storage method using latent heat has a very complex phenomenon for heat transfer and thermal behavior because it is accompanied by a phase change in the course of heating/cooling of the heat storage material. Therefore, many studies have been conducted to produce an experimentally accessible as well as numerical approach to confirm the heat transfer and thermal behavior of phase change materials. The purpose of this study was to investigate the problems encountered during the actual heat transfer from an internal storage tank through simulation of the process of storing and utilizing thermal energy from the thermal storage tank containing charged PCM. This study used analysis methods to investigate the heat transfer characteristics of the PCM with simultaneous heating/cooling conditions in the rectangular space simulating the thermal storage tank. A numerical analysis was carried out in a state considering natural convection using the ANSYS FLUENT(R) program. The result indicates that the slope of the liquid-solid interface in the analysis field changed according to the temperature difference between the heating surface and cooling surface.

ASCENT THERMAL ANALYSIS OF FAIRING OF SPACE LAUNCH VEHICLE

  • Choi Sang-Ho;Kim Seong-Lyong;Kim Insun
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.239-242
    • /
    • 2004
  • The fairing of the launch vehicles has a role of protecting the spacecraft from outer thermal, acoustical, and mechanical loads during flight. Among them, the thermal load is analyzed in the present study. The ascent thermal analyses include aerodynamic heating rate on every point of the fairing, heat transfer through the fairing and spacecraft, and the final temperature during ascent flight phase. A design code based on theoretical/experimental database is applied to calculate the aerodynamic heating rate, and a thermal math program, SINDA/Fluint, is considered for conductive heat transfer of the fairing. The results show that the present design satisfies the allowing temperature of the structure. Another important thermal problem, pyro explosive fairing separation device, is calculated because the pyro system is very sensitive to the temperature. The results also satisfies the pyro thermal condition.

  • PDF

봉과 링 조합형 아이스캡슐을 적용한 축열시스템의 열전달 해석 (Heat Transfer Analysis of a Thermal Storage System using the Ice Capsule of Bar and Ring Module)

  • 김명수;최형권;변성광
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.268-275
    • /
    • 2008
  • The shape and array of ice capsules are very important factors in ice thermal storage system because the heat transfer rate of the system strongly depends upon them. In this paper, a new type of ice capsule composed of bar and ring module is proposed to increase the efficiency of the ice thermal storage system. To investigate the heat transfer rate of the proposed ice capsule, numerical analysis of the incompressible Navier-Stokes equations is performed to compare the proposed bar and ring system with the conventional ice capsules. It is shown that the ice capsule composed of bar and ring has a higher heat transfer rate and a low outlet temperature than the conventional ice capsules for various packing ratios and entrance velocities. Furthermore, it is found that the optimal entrance velocity exists between 0.005 m/s and 0.007 m/s from the present numerical analysis.

스파이크와 돔 형상의 공력 가열 해석 (Analysis on Aerodynamic Heating on Spike and Dome Configuration)

  • 정석영;윤성준;변우식
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 추계 학술대회논문집
    • /
    • pp.109-113
    • /
    • 2002
  • Numerical analysis of aerodynamic heating for KPSAM is performed using aerodynamic heating model suitable to KPSAM, which has complex flow field resulting from the spike attached to the dome, such as large separation area and the strong shock/boundary layer interaction region around reattachment point on the dome. The aerodynamic heating model is validated and modified through the comparison between the flight test measurement and the thermal analysis results. TFD temperature sensors are installed on the dome to measure surface temperature during the flight. Computation results, obtained from the heat transfer analysis on the sensors, agree well with flight test data. The aerodynamic heating model provides heat transfer rate into surface as a boundary condition of unsteady 1D/axisymmetric thermal analysis on the missile structure. The axisymmetric thermal analysis using FLUENT is more versatile than the 1D analysis and can be applied to the heating problem related with complex structures and multi-dimensional heat transfer problems such as prediction of temperature rise at contact surface of different materials.

  • PDF

열성층유동 곡관벽에서의 과도온도분포 예측 (Prediction of Transient Temperature Distributions in the Wall of Curved Piping System Subjected to Internally Thermal Stratification Flow)

  • 조종철;조상진;김윤일;박주엽;김상재;최석기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.474-481
    • /
    • 2001
  • This paper addresses a numerical method for predicting transient temperature distributions in the wall of a curved pipe subjected to internally thermal stratification flow. A simple and convenient numerical method of treating the unsteady conjugate heat transfer in the non-orthogonal coordinate systems is presented. The proposed method is implemented in a finite volume thermal-hydraulic computer code based on a cell-centered, non-staggered grid arrangement, the SIMPLEC algorithm, a higher-order bounded convection scheme, and the modified version of momentum interpolation method. Calculations are performed for the transient evolution of thermal stratification in two curved pipes, where the one has thick wall and the other has so thin wall that its presence can be negligible in the heat transfer analysis. The predicted results show that the thermally stratified flow and transient conjugate heat transfer in a curved pipe with a finite wall thickness can be satisfactorily analyzed by the present numerical method, and that the neglect of wall thickness in the prediction of pipe wall temperature distributions can provide unacceptably distorted results.

  • PDF

Numerical analysis of reflood heat transfer and large-break LOCA including CRUD layer thermal effects

  • Youngjae Park;Donggyun Seo;Byoung Jae Kim;Seung Wook Lee;Hyungdae Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2099-2112
    • /
    • 2024
  • This study examined the effects of CRUD on reflood heat transfer behaviors of nuclear fuel rods during a loss-of-coolant-accident (LOCA) in a pressurized water reactor using a best-estimate thermal-hydraulic analysis code. Changes in thermal properties and boiling heat transfer characteristics of the CRUD layer were extensively reviewed, and a set of correction factors to reflect the changes was implemented into the code. A heat structure layer reflecting the effects of CRUDs on the properties was added to the outer surface of the fuel cladding. Numerical simulations were conducted to examine the effects of CRUDs on reflood cooling of overheated fuel rods for representative separate and integral effect tests, FLECHT-SEASET and LOFT. In LOFT analysis, the average cladding temperature was increased due to the low thermal conductivity of CRUD during steady-state operation; however, in both analyses, the peak cladding temperature decreased, and the quenching time was reduced. Obtained results revealed that when the porous CRUD layer is deposited on the fuel cladding, two opposite effects appear. Low thermal conductivity of the CRUD layer always increases fuel temperature during normal operation; however, its hydrophilic porous structures may contribute to accelerated reflood cooling of fuel rods during a LOCA.

열전달 매질을 고려한 에너지파일의 열전달 거동 분석 (Heat Transfer Analysis of Energy Pile Considering heat transfer medium)

  • 김도현;정상섬;송진영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.963-970
    • /
    • 2010
  • In this study, a series of thermal numerical analysis was conducted through the ground condition and the length and shape of the energy pile. In order to investigate the effect of the thermal properties of ground condition, grout and pile type on heat transfer efficiency in the U-type heat exchanger in energy pile, thermal numerical analysis was done by using ABAQUS. ABAQUS, a finite element analyzing program, was employed to evaluate the temperature distribution on the cross section of energy pile system incorporating HDPE - grout - pile - Ground condition which consists of clay, sand, rock type soil and ground water.

  • PDF

전자계-열계 결합해석에 의한 전력용 변압기의 열전달 해석 (Heat Transfer Analysis of Coupled Electromagnetic-Thermal Field for Power Transformer)

  • 안현모;오연호;한성진
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2155-2161
    • /
    • 2009
  • In this paper, we dealt with the electro-thermal coupling analysis for temperature prediction of power transformer. Heat transfer coefficient are calculated using Nusselt number in accordance with heat source generated from transformer windings and core materials. The calculated temperatures in power transformer were compared to those of measured ones and showed good agreement. This coupling method using heat transfer coefficient can be used at the design stage of power transformer efficiently.