• Title/Summary/Keyword: Thermal Sensitivity

검색결과 636건 처리시간 0.03초

정량적 감각 검사: 한국인에서의 연령별 정상 범위 및 당뇨병성 다발신경병증에서의 유용성 평가 (Quantitative Sensory Test: Normal Range in Korean Adults and Application to Diabetic Polyneuropathy)

  • 김수현;안석원;김성민;홍윤호;박경석;성정준;이광우
    • Annals of Clinical Neurophysiology
    • /
    • 제12권1호
    • /
    • pp.21-26
    • /
    • 2010
  • Background: Although quantitative sensory test (QST) is being used with increasing frequency for measuring sensory thresholds in clinical practice and epidemiologic studies, there has been no age-matched normative data in Korean adults. The objective of this study is to evaluate the value of QST in diabetic polyneuropathy with normal range in Korean adults. Methods: The Computer Aided Sensory Examination IV 4,2 (WR Medical Electronics Co., Stillwater, Minnesota, U.S.A.), with 4,2,1 stepping algorithm was used to determine vibration and cold perception threshold in 70 normal controls and 19 patients with diabetic polyneuropathy aged from 21 to 79 years. The data were used to define age-matched upper and lower normal limits and normal range of side to side difference. We also evaluated the duration of diabetes, serum HbA1C level, and findings of nerve conduction study (NCS) and QST in patients with diabetic polyneuropathy. Results: In normal adults, sensory thresholds slightly increased with age, and a slight side-to-side difference was observed. The diagnostic sensitivity of QST was not higher than NCS in patients with diabetic polyneuropathy (36.8% vs. 42.1%, p=0.716), especially among elderly patients. Conclusions: QST might be used as a complementary test for NCS in the diagnosis of diabetic polyneuropathy. Although the QST is a simple method for the evaluation of peripheral nerve function, there are some limitations. Most of all, because the QST measuring is dependent on the subjective response of patients, the degree of concentration and cooperation of the patients can significantly affect the result. And thus, attention should be paid during the interpretation of QST results in patients with peripheral neuropathy.

하부전극 물질에 따른 CdTe박막 증착과 그에 따른 전기적 특성 평가

  • 김대국;신정욱;이영규;김성헌;이건환;남상희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.327-328
    • /
    • 2012
  • 의료분야의 진단 방사선 장비는 초기의 필름방식 및 카세트에서 진보되어 현재는 디지털방식의 DR (Digital Radiography)이 널리 사용되며 이에 관한 연구개발이 활발히 진행 되고 있다. DR은 일반적으로 직접방식과 간접방식으로 나눌 수 있다. 직접방식의 원리는 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 전압을 인가하여 전기장을 유도한 가운데, X선을 조사하면 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이것은 양단에 유도된 전기장의 영향으로 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 하부기판을 통하여 이미지로 변조된다. 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 조사된 X선을 형광체에서 가시광선으로 전환하고, 이를 Photodiode와 같은 광변환소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말한다. 본 연구에서는 직접방식에서 이용되는 광도전체 중 흡수효율이 높고 Mobility가 뛰어난 CdTe를 선정하여 PVD (Physical vapor deposition)방식으로 300 m의 두께를 목표로 하여 증착을 진행하였다. Chamber의 진공도가 $2.5{\times}10^{-2}$ Torr로 도달 시점부터, Substrate와 Boat에 열을 가하였다. Substrate온도는 $350^{\circ}C$, Boat온도는 $300^{\circ}C$도로 설정하여 11시간 동안 진행하였다. Substrate온도는 $303^{\circ}C$, Boat온도는 $297^{\circ}C$도부터 증착이 시작되어 선형적인 증가세 추이를 나타내어 Substrate 및 Boat온도가 설정 값에 도달 하였을 때, $25{\sim}34.4{\AA}/s$ 증착율을 나타내었다. 하부전극의 물질에 따른 CdTe증착 효율성 평가를 진행한 후, 그에 따른 전기적 특성을 알아보았다. 하부전극의 물질로는 ITO (Indium Tin Oxide), Parylene이 코팅 된 ITO, Au, Ag를 사용하였다. 하부전극의 물질 상단에 Thermal Evaporation System을 사용하여 CdTe를 증착한 후, Cdte 상단에 Au를 증착 시켜 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 증착 결과 ITO와 Ag상단에 증착시킨 CdTe박막은 박리가 되었고, Au와 Parylene이 코팅 된 ITO에는 CdTe박막이 안정적이게 형성이 되었다. 이 두 샘플에 대하여 동일한 조건으로 민감도와 암전류를 측정 시, Parylene이 코팅된 ITO를 하부전극으로 사용한 CdTe박막은 0.1021 pA/$cm^2$의 암전류와 1.027 pC/$cm^2$의 민감도를 나타낸 반면, Au를 하부전극으로 사용한 CdTe박막은 0.0381 pA/$cm^2$의 암전류와 1.214 pC/$cm^2$의 민감도를 나타내어 Parylene이 코팅된 ITO보다 우수한 전기적 특성을 나타내었다. 따라서 Au는 CdTe박막 증착 시, 하부전극 기판으로서 뛰어난 특성을 나타내는 것을 알 수 있었다.

  • PDF

지각과민치아에 대한 Nd:YAG 레이저 조사의 효과 (Desensitizing Effects of a Nd:YAG Laser Irradiation on Hypersensitive Dentine)

  • 정성용;김경희;고명연;안용우;박준상
    • Journal of Oral Medicine and Pain
    • /
    • 제30권4호
    • /
    • pp.465-473
    • /
    • 2005
  • 냉온자극 또는 잇솔질에 불편감을 호소하는 치과 외래 환자를 72명을 대상으로 레이저 조사를 시행한 실험군(45명)과 모의 레이저 조사를 시행한 대조군(27명)으로 나누어 지각 과민 치아의 치경부에 냉자극 및 기계적 자극을 가하여 대상자가 느끼는 불편감을 NPS로 평가하였다. 치아의 통증역치 평가를 위하여 전기치수검사기(EPT)를 사용하였다. 각 치아에 대한 레이저 조사에는 pulsed Nd:YAG 레이저를 사용하였고 조사조건은 1.5W, 20Hz, 75mJ/pulse으로 4분간 비접촉식으로 시행하였다. 대상자의 반응을 레이저 조사 전과 직후, 1주 이내, 2주 이내 각각 평가하여 다음과 같은 결과를 얻었다. 1. 지각 과민 치아에 대한 Nd:YAG 레이저 조사는 지각 과민을 완화시켜 주었으며 대조군에 비해 그 효과가 현저하였다. 2. 심한 지각 과민을 호소하는 치아에 대한 위약 효과는 존재하였으나 중등도의 지각 과민을 호소하는 치아에 대한 위약효과는 배제할 수 있었다. 3. 지각 과민 치아에 대한 Nd:YAG 레이저 조사는 전기치수검사에 의한 통증역치에 영향을 주지 않았다. 4. 지각 과민 치아에 대한 Nd:YAG 레이저 조사의 효과는 최소 2주는 지속되었다. 따라서 지각 과민 치아에 대한 치료법의 하나로 Nd:YAG 레이저 조사가 임상적으로 유용할 것으로 사료된다.

형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성 (Characterization of the a-Se Film for Phosphor based X-ray light Modulator)

  • 강상식;박지군;조성호;차병열;신정욱;이건환;문치웅;남상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Changes in expression of monocarboxylate transporters, heat shock proteins and meat quality of Large White Yorkshire and Ghungroo pigs during hot summer period

  • Parkunan, Thulasiraman;Das, Arun K.;Banerjee, Dipak;Mohanty, Niharika;Paul, Avishek;Nanda, P.K.;Biswas, TK;Naskar, Syamal;Bag, Sadhan;Sarkar, Mihir;Mohan, Narayana H.;Das, Bikash Chandra
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제30권2호
    • /
    • pp.246-253
    • /
    • 2017
  • Objective: Present study explores the effect of hot summer period on the glycolytic rate of early post-mortem meat quality of Ghungroo and Large White Yorkshire (LWY) pig and comparative adaptability to high temperature between above breeds by shifting the expression of stress related genes like mono-carboxylate transporters (MCTs) and heat shock proteins (HSPs). Methods: Healthy pigs of two different breeds, viz., LYW and Ghungroo (20 from each) were maintained during hot summer period (May to June) with a mean temperature of about $38^{\circ}C$. The pigs were slaughtered and meat samples from the longissimus dorsi (LD) muscles were analyzed for pH, glycogen and lactate content and mRNA expression. Following 24 h of chilling, LD muscle was also taken from the carcasses to evaluate protein solubility and different meat quality measurements. Results: LWY exhibited significantly (p<0.01) higher plasma cortisol and lactate dehydrogenase concentration than Ghungroo indicating their higher sensitivity to high temperature. LD muscle from LWY pigs revealed lower initial and ultimate pH values and higher drip loss compared to Ghungroo, indicating a faster rate of pH fall. LD muscle of Ghungroo had significantly lower lactate content at 45 min postmortem indicating normal postmortem glycolysis and much slower glycolytic rate at early postmortem. LD muscle of LWY showed rapid postmortem glycolysis, higher drip loss and higher degrees of protein denaturation. Ghungroo exhibited slightly better water holding capacity, lower cooking loss and higher protein solubility. All HSPs (HSP27, HSP70, and HSP90) and MCTs (MCT1, MCT2, and MCT4) in the LD muscle of pigs inclined to increase more in Ghungroo than LWY when exposed to high temperature. Conclusion: Effect of high temperature on the variation of HSPs and MCTs may play a crucial role in thermal tolerance and adaptation to different climatic conditions, pH regulation, muscle acidification, drip loss, protein denaturation and also in postmortem meat quality development.

중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발 (Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor)

  • 정현규;이동훈;이윤상;허형;정용무
    • 비파괴검사학회지
    • /
    • 제24권2호
    • /
    • pp.164-170
    • /
    • 2004
  • 중수로 내부구조물 중 칼란드리아관(CT)와 액체주입노즐관(LIN)은 서로 수평으로 90도 교차되게 배열되어 있으며 원자로 내의 열, 방사선, 하중에 의해 creep 현상이 발생되어 처짐이 일어난다. 칼란드리아관은 액체주입노즐관과 동일 재료이나 운전 온도와 방사선 조사량으로 인해 액체주입노즐관에 비해 상당히 열악한 조건에 노출되어 있으므로 처짐이 심각할 것으로 예상된다. 만약 두 관의 접촉이 발생되면 원전 안전성에 영향을 미칠 것이므로 인접관에 대한 접촉여부 점검은 중수로 안전현안 중 하나이다. 이러한 접촉여부를 확인하기 위하여 핵연료채널 내부로 탐촉자를 삽입하여 인접관과의 교차점에서 간격을 직접측정하기 위한 방법으로 원거리장 와전류검사 (RFECT) 기술을 적용하였다. 핵연료채널 인접관인 액체주입노즐관 신호 취득시 발생 가능한 잡음 신호(두께변화, Lift-off, 수축)에 대해 체적적분법에 의한 모델링으로 조사하였고, 신호와 잡음과의 분리 가능한 조건을 확인하였다. 원거리장 와전류검사 적정 조건은 민감도와 투과력 그리고 잡음신호 등을 동시에 고려하여 주파수 1kHz와 코일간격 200m로서 결정하였다. 원거리장 와전류검사 실험 결과 칼란드리아관과 액체주입노즐관 사이의 간격 변화에 대한 신호 특성을 전압평면을 이용하여 상관관계를 도출하였다.

하중변환 알고리듬을 적용한 줄눈 콘크리트 포장해석 프로그램 개발 (Development of Structure Analysis Program for Jointed Concrete Pavement Applying Load Discretization Algorithm)

  • 윤태영;김지원;조윤호
    • 한국도로학회논문집
    • /
    • 제5권4호
    • /
    • pp.1-11
    • /
    • 2003
  • 최근 국내에서는 국내 여건을 고려한 설계법을 개발함과 동시에 이미 공용중에 있는 도로 포장의 성능향상을 위한 $\ulcorner$한국형 포장 설계법 개발과 성능개선 연구$\lrcorner$가 진행되고 있다. 본 연구에서 개발된 $\ulcorner$하중변환 알고리듬을 적용한 줄눈콘크리트 포장 해석 프로그램$\lrcorner$은 이러한 연구의 세부분야인 콘크리트 포장 설계법 개발분야의 연구 결과로서 기본 프로그램 부분과 하중변환 부분으로 구분되어 구성되며, 기본 프로그램 부분에서는 판/쉘 요소, 스프링 요소 보 요소를 이용하여 줄눈 콘크리트 포장의 콘크리트 슬래브, 하부층, 다웰바를 모사한다. 하중변환 부분에서는 기존의 연속체 요소에 대한 하중변환 알고리듬을 수정/적용하여 요소망에 제약을 받지 않고 다양한 하중 조건을 해석한다. 또한 프로그램은 하중변환 알고리듬을 적용하여 해석을 수행하는 등분포 하중 이외에, 집중하중. 온도하중, 자중 등을 고려할 수 있는 특징이 있다. 개발된 프로그램의 특성을 분석하기 위한 민감도 분석 결과 하중크기 및 위치와 콘크리트 슬래브의 두께가 포장의 거동에 가장 큰 영향을 미치는 인자로 분석되었으며 이는 Westergaard 계산식, ILLISLAB과 유사한 결과이다.

  • PDF

CATHARE2와 RELAP5/MOD3를 이용한 BETHSY 6.2 TC 소형 냉각재상실사고 실험결과의 해석 (Comparison Of CATHARE2 And RELAP5/MOD3 Predictions On The BETHSY 6.2% TC Small-Break Loss-Of-Coolant Experiment)

  • Chung, Young-Jong;Jeong, Jae-Jun;Chang, Won-Pyo;Kim, Dong-Su
    • Nuclear Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.126-139
    • /
    • 1994
  • 본 연구에서는 BETHSY 실험장치에서 수행한 6" 소형 냉각재 상실사고(LOCA) 실험을 최적 열수력 코드인 CATHARE2 V1.2와 RELAP5/MOD3를 이용하여 계산했다. 본 연구의 주 목적은 소형 LOCA시 관심을 가지는 주요 물리현상인 이상 임계유동, 감압과정, 노심수위 감소, loop seal clearing 등에 대한 두 코드의 소형 LOCA 계산모의능력을 평가하는 것이다. 두코드는 이상 유동현상의 전개 경향이나 발생시점을 비교적 잘 예측하는 것으로 나타났고, CATHARE2의 경우가 실험과 더 잘 일치했다. 그렇지만 두 코드는 loop seal clearing 현상, loop seal clearing 발생후의 노심수위, accumulator 유량거동 등의 예측에는 약간의 편차를 보였는데, 편차의 정도는 RELAP5가 CATHARE2보다 더 큰 것으로 나타났다. 두 코드의 편차요인을 보다 상세히 분석하기 위하여 계면 마찰력, mesh크기, 파단노즐 junction에서의 방출계수(Discharge coefficient)등에 대하여 민감도분석을 수행하였다. 그 결과 CATHARE2의 경우는 계면 마찰력을 증가시킴으로써 감압과정시 일차계통의 질량분포, 즉 증기 발생기 입구 공동(SG inlet plenum)에서의 차압과 Cross√er leg의 차압이 개선되었으며, 증기발생기 외측 열전달계수를 증가시킴으로써 중기발생기의 압력변화를 개선할 수 있었다. RELAP5의 경우는 어떤 하나의 입력변수를 변화시켜서 과도기의 결과를 개선할 수 없었으며 다만, 계면 마찰력 모델링에 여전히 많은 불화실성이 내포되어 있음을 확인했다.확인했다.

  • PDF

Extremely Low Frequency Magnetic Field is an Environmental Stress Factor by Exerting Oxidative Stress

  • Park, Yong-Jin;Park, Won-Joo;Yim, Sung-Hyuk;Yang, Seong-Jun;Sun, Yuan Lu;Jeong, Ji-Hoon;Park, Eon-Sub
    • Biomolecules & Therapeutics
    • /
    • 제15권1호
    • /
    • pp.58-64
    • /
    • 2007
  • The previous study reported the biological effect of magnetic field exerted by acting on endocrine and anti-oxidant system. The present study aims to study whether ELF-MF (extremely low frequency magnetic field) affects the physiological endocrine systems such as thyroid and whether ELF-MF affects the defense system against oxidative stress when it alters the function of thyroid. Finally, we correlate the effects of MF on oxidative stress, and adrenal and thyroid with an environmental stress factor. We exposed sham or MF to rats for 5 or 25 days. After the exposure, we determined pain sensitivity, level of TSH, $T_3$ and free $T_4$ in plasma. We also assayed in whole brain, lipid peroxidation, the activity of enzymatic anti-oxidant defense including superoxide dismutase(SOD) and glutathione peroxidase (GPx), and non enzymatic defense such as reduced or oxidized glutathione contents. MF induced the hypersensitivity to thermal stimuli with the reduction of latency. $T_3$ and $T_4$ levels were also increased by the exposure of MF. In addition, we observed the rise of MDA level in rat brain by MF although the MF did not change superoxide dismutase and glutathione peroxidase activity. The effect of MF on both reduced and oxidized glutathione results in decrease in reduced or oxidized glutathione in whole brain. In every experiment, there was no significant difference in MF influence between short term (5 days) and long term (25 days) exposure. Taken together, MF exposure affects the thyroid hormonal control in brain. The elevated thyroid hormone acts on brain, leading to hyper-utilization of oxygen. This phenomenon may be correlated with oxidative stress resulting from MF exposure. In conclusion, we suggest that MF exposure may be an environmental stress by exerting oxidative stress.

전산유체역학을 이용한 Fischer-Tropsch 마이크로채널 반응기 반응채널구조에 따른 열적 효과 분석 (Analysis on Thermal Effects of Process Channel Geometry for Microchannel Fischer-Tropsch Reactor Using Computational Fluid Dynamics)

  • 이용규;정익환;나종걸;박성호;;한종훈
    • Korean Chemical Engineering Research
    • /
    • 제53권6호
    • /
    • pp.818-823
    • /
    • 2015
  • 본 연구에서는 전산유체역학(CFD)을 이용하여 마이크로채널 내부의 Fischer-Tropsch(FT) 반응을 모사하였고, 나아가 반응채널의 너비와 높이, 냉각채널과의 거리 그리고 채널 사이 간격을 변수로 두고 채널 내부 온도에 대해 민감도 분석을 수행하였다. 마이크로채널 반응기는 채널 간의 열교환을 고려하기 위한 5개의 반응채널과 냉각채널을 대신한 냉각면으로 이루어져 있으며 채널의 높이와 너비를 포함한 변수들의 길이는 0.5 mm ~ 5.0 mm 범위에서 설정하였다. 반응물로는 $H_2$와 CO의 혼합기체($H_2/CO$ molar ratio=2)를 사용하였으며 반응기의 운전 조건은 $GHSV=10000h^{-1}$, 압력 20 bar와 온도 483 K($210^{\circ}C$)이다. 민감도 분석의 결과로 반응채널 내부의 최대 온도는 채널의 높이에 비례하며 너비에 대해서는 특정 길이 이상에서 영향을 받지 않는 것을 확인하였으며 이 중에 냉각채널과의 거리와 채널 사이 간격은 채널 내부 온도에 거의 영향을 미치지 않았다. 따라서 채널 레이아웃에서 반응채널의 높이는 짧을수록(약 2 mm 이하), 너비는 길수록(약 4 mm 이상) 열제거뿐만 아니라 생산량 측면에서 이득을 얻을 수 있었다.