• Title/Summary/Keyword: Thermal Sensitivity

검색결과 636건 처리시간 0.025초

SnO2 반도체 나노선 네트웍 구조를 이용한 NO2 가스센서 소자 구현 (SnO2 Semiconducting Nanowires Network and Its NO2 Gas Sensor Application)

  • 김정연;김병국;최시혁;박재관;박재환
    • 한국재료학회지
    • /
    • 제20권4호
    • /
    • pp.223-227
    • /
    • 2010
  • Recently, one-dimensional semiconducting nanomaterials have attracted considerable interest for their potential as building blocks for fabricating various nanodevices. Among these semiconducting nanomaterials,, $SnO_2$ nanostructures including nanowires, nanorods, nanobelts, and nanotubes were successfully synthesized and their electrochemical properties were evaluated. Although $SnO_2$ nanowires and nanobelts exhibit fascinating gas sensing characteristics, there are still significant difficulties in using them for device applications. The crucial problem is the alignment of the nanowires. Each nanowire should be attached on each die using arduous e-beam or photolithography, which is quite an undesirable process in terms of mass production in the current semiconductor industry. In this study, a simple process for making sensitive $SnO_2$ nanowire-based gas sensors by using a standard semiconducting fabrication process was studied. The nanowires were aligned in-situ during nanowire synthesis by thermal CVD process and a nanowire network structure between the electrodes was obtained. The $SnO_2$ nanowire network was floated upon the Si substrate by separating an Au catalyst between the electrodes. As the electric current is transported along the networks of the nanowires, not along the surface layer on the substrate, the gas sensitivities could be maximized in this networked and floated structure. By varying the nanowire density and the distance between the electrodes, several types of nanowire network were fabricated. The $NO_2$ gas sensitivity was 30~200 when the $NO_2$ concentration was 5~20ppm. The response time was ca. 30~110 sec.

An Application of Realistic Evaluation Methodology for Large Break LOCA of Westinghouse 3 Loop Plant

  • Choi, Han-Rim;Hwang, Tae-Suk;Chung, Bub-Dong;Jun, Hwang-Yong;Lee, Chang-Sub
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.513-518
    • /
    • 1996
  • This report presents a demonstration of application of realistic evaluation methodology to a posturated cold leg large break LOCA in a Westinghouse three-loop pressurized water reactor with 17$\times$17 fuel. The new method of this analysis can be divided into three distinct step: 1) Best Estimate Code Validation and Uncertainty Quantification 2) Realistic LOCA Calculation 3) Limiting Value LOCA Calculation and Uncertainty Combination RELAP5/MOD3/K [1], which was improved from RELAP5/MOD3.1, and CONTEMPT4/MOD5 code were used as a best estimate thermal-hydraulic model for realistic LOCA calculation. The code uncertainties which will be determined in step 1) were quantified already in previous study [2], and thus the step 2) and 3) for plant application were presented in this paper. The application uncertainty parameters are divided into two categories, i.e. plant system parameters and fuel statistical parameters. Single parameter sensitivity calculations were performed to select system parameters which would be set at their limiting value in Limiting Value Approach (LVA) calculation. Single run of LVA calculation generated 27 PCT data according to the various combinations of fuel parameters and these data provided input to response surface generation. The probability distribution function was generated from Monte Carlo sampling of a response surface and the upper 95$^{th}$ percentile PCT was determined. Break spectrum analysis was also made to determine the critical break size. The results show that sufficient LOCA margin can be obtained for the demonstration NPP.

  • PDF

산화물 반도체 박막 가스센서 어레이의 제조 (Fabrication of oxide semiconductor thin film gas sensor array)

  • 이규정;김석환;허창우
    • 한국정보통신학회논문지
    • /
    • 제4권3호
    • /
    • pp.705-711
    • /
    • 2000
  • 반도체 제조공정과 미세가공 기술을 이용하여 $300^{\circ}C$의 동작온도에서 약 60 mW의 전력소모를 갖는 산화물 반도체 박막 가스센서 어레이를 제조하였다. 멤브레인의 우수한 열적 절연은 $0.1\mum\; 두께의\; Si_3N_4와\; 1\mum$ 두께의 PSG의 이중 층에 의한 것으로, 각각 LPCVD(저압화학 기상증착)와 APCVD(대기압 화학 기상증착)에 의해 제조되었다. 센서 어레이의 4가지 산화물 반도체 박막 감지물질로는 1 wt.% Pd가 도핑된 $SnO_2,\; 6 we.% A1_2O_3$가 도핑된 ZnO, $WO_3$, ZnO를 이용하였으며,4가지 감지물질의 베이스라인 저항은 $300^{\circ}C$ 에서 3일 동안의 에이징을 거친 후 안정됨을 보였다. 제조된 초소형 산화물 반도체 박막 가스센서 어레이는 여러 가지 가스의 노출 시 유용한 저항 변화를 나타내었으며 감도는 감지 물질에 강하게 의존함을 알 수 있었다.

  • PDF

THERMALHYDRAULIC EVALUATIONS FOR A CANFLEX BUNDLE WITH NATURAL OR RECYCLED URANIUM FUEL IN THE UNCREPT AND CREPT CHANNELS OF A CANDU-6 REACTOR

  • Jun, Ji-Su
    • Nuclear Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.479-490
    • /
    • 2005
  • The thermalhydraulic performance of a CANDU-6 reactor loaded with various CANFLEX fuel bundles is evaluated by the NUCIRC code, which is incorporated with recent models of pressure drop and critical heat flux (CHF) predictions based on high-pressure steam-water tests for the CANFLEX bundle as well as a 37-element bundle. The distributions of channel flow rate, channel exit quality, critical channel power (CCP), and critical power ratio (CPR) for the CANFLEX bundles (with natural or recycled uranium fuel) in the CANDU-6 reactor fuel channel are calculated by the code. The effects of axial and radial heat flux on CCP are evaluated by assuming that the recycled uranium fuel (CANFLEX-RU) has the same geometric data as the natural uranium fuel bundle (CANFLEX-NU), but a different power distribution due to different fuel composition and refueling scheme. In addition, the effects of pressure tube creep and bearing-pad height are examined by comparing various results of uncrept, and $3.3\%\;and\;5.1\%$ crept channels loaded with CANFLEX bundles with 1.4 mm or 1.7 mm high bearing-pads with those of the 37-element bundle. The distributions of the channel flow rate and CCP for the CANFLEX-NU or -RU bundle show a typical trend for a CANDU-6 reactor channel, and the CPRs are maintained above at least 1.444 (NU) or 1.455 (RU) in the uncrept channel. The enhanced CHF of the CANFLEX bundle (particularly with 1.7mm height bearing-pads) produces a higher thermal margin and considerably less sensitivity to CCP reduction due to the pressure tube creep than the 37-element bundle. The CCP enhancement due to the raised bearing-pads is estimated to be about $3\%\~5\%$ for the CANFLEX-NU and $2\%\~6\%$ for the CANFLEX-RU bundle, respectively.

High Density Polyethylene (HDPE) / Exfoliated Graphite (EFG) 나노복합필름 제조와 특성에 관한 연구 (Preparation and Characterization of High Density Polyethylene (HDPE)/Exfoliated Graphite (EFG) Nanocomposite Films)

  • 권혁;김도완;서종철
    • 한국포장학회지
    • /
    • 제19권2호
    • /
    • pp.95-102
    • /
    • 2013
  • 고밀도 폴리에틸렌(High density polyethylene, HDPE)을 수분에 민감한 전기전자제품, 의약품 등을 위한 하이배리어 패키징 소재로써 적용하기 위해서 높은 가로세로비(High aspect ratio)를 가진 Exfoliated graphite (이하 EFG)를 필러로 도입하였다. 또한, 효과적인 분산성과 혼화성을 위해서 상용화제를 첨가하여 HDPE/EFG 나노복합필름을 제조하였다. HDPE/EFG 나노복합필름의 EFG 함량에 따른 화학적 특성, 모폴로지(Morphology), 열적 특성 및 수분차단 특성을 조사하였다. HDPE와 EFG 사이에 화학적 결합이나 상호작용이 약하지만, EFG를 첨가함에 따라 수증기 투과도는 127에서 78 (70 ${\mu}m{\cdot}g/m^2$, $day{\cdot}atm$)까지 감소되었다. 특히, HDPE/EFG 나노복합필름은 EFG의 함량이 0.5%일 때 가장 효과적이며, 그 이상의 함량에서는 물성이 향상되지 않았다. 따라서, 물성의 극대화를 위해서는 EFG의 분산성 향상 및 HDPE와 EFG의 화학적 결합 등의 혼화성 개선에 관한 추가적인 연구가 필요하다.

  • PDF

노즐 축소부 수렴각이 고속 광섬유 피복유동에 미치는 영향 (EFFECTS OF CONVERGENT ANGLE OF NOZZLE CONTRACTION ON HIGH-SPEED OPTICAL FIBER COATING FLOW)

  • 박신;김경진;곽호상
    • 한국전산유체공학회지
    • /
    • 제21권4호
    • /
    • pp.11-18
    • /
    • 2016
  • A numerical study is conducted on the optical fiber coating flow in a primary coating nozzle consisting of three major parts: a resin chamber, a contraction and a coating die of small diameter. The flow is driven by the optical fiber penetrating the center of the nozzle at a high speed. The axisymmetric two-dimensional flow and heat transfer induced by viscous heating are examined based on the laminar flow assumption. Numerical experiments are performed with varying the convergent angle of nozzle contraction and the optical fiber drawing speed. The numerical results show that for high drawing speed greater than 30 m/s, there is a transition in the essential flow features depending on the convergent angle. For a large convergent angle greater than $30^{\circ}$, unfavorable multicellular flow structures are monitored, which could be associated with wall boundary-layer separation. In the regime of small convergent angle, as the angle increases, the highest resin temperature at the exit of die and the coating thickness decrease but the sensitivity of coating thickness on drawing speed and the maximum shear strain of resin on the optical fiber increase. The effects of the convergent angle are discussed in view of compromise searching for an appropriate angle for high-speed optical fiber coating.

수직벽 화재 자연대류에 의한 난류 경계층 열유동 특성 해석 (ANALYSIS OF TURBULENT BOUNDARY LAYER OF NATURAL CONVECTION CAUSED BY FIRE ALONG VERTICAL WALL)

  • 장용준;김진호;류지민
    • 한국전산유체공학회지
    • /
    • 제21권4호
    • /
    • pp.1-10
    • /
    • 2016
  • The analysis of characteristics of turbulent flow and thermal boundary layer for natural convection caused by fire along vertical wall is performed. The 4m-high vertical copper plate is heated and kept at a uniform surface temperature of $60^{\circ}C$ and the surrounding fluid (air) is kept at $16.5^{\circ}C$. The flow and temperature is solved by large eddy simulation(LES) of FDS code(Ver.6), in which the viscous-sublayer flow is calculated by Werner-Wengle wall function. The whole analyzed domain is assumed as turbulent region to apply wall function even through the laminar flow is transient to the turbulent flow between $10^9$<$Gr_z$<$10^{10}$ in experiments. The various grids from $7{\times}7{\times}128$ to $18{\times}18{\times}128$ are applied to investigate the sensitivity of wall function to $x^+$ value in LES simulation. The mean velocity and temperature profiles in the turbulent boundary layer are compared with experimental data by Tsuji & Nagano and the results from other LES simulation in which the viscous-sublayer flow is directly solved with many grids. The relationship between heat transfer rate($Nu_z$) and $Gr_zPr$ is investigated and calculated heat transfer rates are compared with theoretical equation and experimental data.

신경손상에 의해 유발된 과민통반응에서 말초 케모카인 CCL3의 역할 (The Role of the Peripheral Chemokine, CCL3, in Hyperalgesia following Peripheral Nerve Injury in the Rat)

  • 임중우;이현주;남택상;윤덕미
    • The Korean Journal of Pain
    • /
    • 제21권3호
    • /
    • pp.187-196
    • /
    • 2008
  • Background: Upregulation of one type of the pro-inflammatory chemokine (CCL2) and its receptor (CCR2) following peripheral nerve injury contributes to the induction of neuropathic pain. Here, we examined whether another type of chemokine (CCL3) is involved in neuropathic pain. Methods: We measured changes in mechanical and thermal sensitivity in the hind paws of naïve rats or rats with an L5 spinal nerve ligation (SNL) after intra-plantar injection of CCL3 or met-RANTES, an antagonist of the CCL3 receptor, CCR1. We also measured CCL3 levels in the sciatic nerve and the hind paw skin as well as CCR1 expression in dorsal root ganglion (DRG) cells from the lumbar spinal segments. Results: Intra-plantar injection of CCL3 into the hind paw of naive rats mimicked L5 SNL-produced hyperalgesia. Intra-plantar injection of met-RANTES into the hind paw of rats with L5 SNL attenuated hyperalgesia. L5 SNL increased CCL3 levels in the sciatic nerve and the hind paw skin on the affected side. The number of CCR1-positive DRG cells in the lumbar segments was not changed following L5 SNL. Conclusions: Partial peripheral nerve injury increases local CCL3 levels along the degenerating axons during Wallerian degeneration. This CCL3 binds to its receptor, CCR1, located on adjacent uninjured afferents, presumably nociceptors, to induce hyperalgesia in the neuropathic pain state.

GC-ECD/MS를 이용한 농산물 중 Captan, Folpet, Captafol 및 Chlorothalonil의 잔류분석법 (Determination of Captan, Folpet, Captafol and Chlorothalonil Residues in Agricultural Commodities using GC-ECD/MS)

  • 이수진;황영선;김영학;권찬혁;도정아;임무혁;이영득;정명근
    • 한국환경농학회지
    • /
    • 제29권2호
    • /
    • pp.165-175
    • /
    • 2010
  • A gas chromatographic (GC) method was developed to determine residues of captan, folpet, captafol, and chlorothalonil, known as broad-spectrum protective fungicides for the official purpose. All the fungicide residues were extracted with acetone containing 3% phosphoric acid from representative samples of five agricultural products which comprised rice, soybean, apple, pepper, and cabbage. The extract was diluted with saline, and dichloromethane partition was followed to recover the fungicides from the aqueous phase. Florisil column chromatography was additionally employed for final cleanup of the extracts. The analytes were then determined by gas chromatography using a DB-1 capillary column with electron capture detection. Reproducibility in quantitation was largely enhanced by minimization of adsorption or thermal degradation of analytes during GLC analysis. Mean recoveries generated from each crop sample fortified at two levels in triplicate ranged from 89.0~113.7%. Relative standard deviations (RSD) were all less than 10%, irrespective sample types and fortification levels. As no interference was found in any samples, limit of quantitation (LOQ) was estimated to be 0.008 mg/kg for the analytes except showing higher sensitivity of 0.002 mg/kg for chlorothalonil. GC/Mass spectrometric method using selected-ion monitoring technique was also provided to confirm the suspected residues. The proposed method was reproducible and sensitive enough to determine the residues of captan, folpet, captafol, and chlorothalonil in agricultural commodities for routine analysis.

Microcantilever biosensor: sensing platform, surface characterization and multiscale modeling

  • Chen, Chuin-Shan;Kuan, Shu;Chang, Tzu-Hsuan;Chou, Chia-Ching;Chang, Shu-Wei;Huang, Long-Sun
    • Smart Structures and Systems
    • /
    • 제8권1호
    • /
    • pp.17-37
    • /
    • 2011
  • The microcantilever (MCL) sensor is one of the most promising platforms for next-generation label-free biosensing applications. It outperforms conventional label-free detection methods in terms of portability and parallelization. In this paper, an overview of recent advances in our understanding of the coupling between biomolecular interactions and MCL responses is given. A dual compact optical MCL sensing platform was built to enable biosensing experiments both in gas-phase environments and in solutions. The thermal bimorph effect was found to be an effective nanomanipulator for the MCL platform calibration. The study of the alkanethiol self-assembly monolayer (SAM) chain length effect revealed that 1-octanethiol ($C_8H_{17}SH$) induced a larger deflection than that from 1-dodecanethiol ($C_{12}H_{25}SH$) in solutions. Using the clinically relevant biomarker C-reactive protein (CRP), we revealed that the analytical sensitivity of the MCL reached a diagnostic level of $1{\sim}500{\mu}g/ml$ within a 7% coefficient of variation. Using grazing incident x-ray diffractometer (GIXRD) analysis, we found that the gold surface was dominated by the (111) crystalline plane. Moreover, using X-ray photoelectron spectroscopy (XPS) analysis, we confirmed that the Au-S covalent bonds occurred in SAM adsorption whereas CRP molecular bindings occurred in protein analysis. First principles density functional theory (DFT) simulations were also used to examine biomolecular adsorption mechanisms. Multiscale modeling was then developed to connect the interactions at the molecular level with the MCL mechanical response. The alkanethiol SAM chain length effect in air was successfully predicted using the multiscale scheme.