Analysis Models of Concrete Slabs-on-Grade Considering Horizontal Resistance at Slab Bottom and Behavior under Thermal Loads (슬래브 하부 수평저항을 고려한 지반위의 콘크리트 슬래브 해석 모델 및 온도하중에 의한 거동 분석)

  • Kim Seong-Min;An Zu-Og
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.271-282
    • /
    • 2006
  • The behavior of the concrete slabs on grade considering the horizontal resistance at the slab bottom, which exists due to the shear resistance of the foundation and the friction between the slab and the foundation, has been investigated when the slabs-on-grade are subjected to the thermal load. Analytical formulations have been developed to include the effect of the horizontal resistance at the slab bottom employing the thin plate on an elastic foundation that is widely used for the analysis of concrete slabs-on-grade and rigid pavement systems. Finite element formulations have then been developed using the plate bending elements and the flat shell elements. The solutions from the analytical and numerical models have been compared and showed very good agreement. The sensitivity of the horizontal resistance to the stresses of the concrete slab has been investigated with various values of the slab thickness, elastic modulus, and vortical stiffness of the foundation when subjected to the temperature gradient between the top and bottom of the slab and the uniform temperature drop throughout the slab depth. The analysis results show that the horizontal resistance at the plate bottom can significantly affect the stresses of the slab when the thermal loads are applied.

A Comparative Study of Various Fuel for Newly Optimized Onboard Fuel Processor System under the Simple Heat Exchanger Network (연료전지차량용 연료개질기에 대한 최적연료비교연구)

  • Jung, Ikhwan;Park, Chansaem;Park, Seongho;Na, Jonggeol;Han, Chonghun
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.720-726
    • /
    • 2014
  • PEM fuel cell vehicles have been getting much attraction due to a sort of highly clean and effective transportation. The onboard fuel processor, however, is inevitably required to supply the hydrogen by conversion from some fuels since there are not enough available hydrogen stations nearby. A lot of studies have been focused on analyses of ATR reactor under the assumption of thermo-neutral condition and those of the optimized process for the minimization of energy consumption using thermal efficiency as an objective function, which doesn't guarantee the maximum hydrogen production. In this study, the analysis of optimization for 100 kW PEMFC onboard fuel processor was conducted targeting various fuels such as gasoline, LPG, diesel using newly defined hydrogen efficiency and keeping simply synthesized heat exchanger network regardless of external utilities leading to compactness and integration. Optimal result of gasoline case shows 9.43% reduction compared to previous study, which shows the newly defined objective function leads to better performance than thermal efficiency in terms of hydrogen production. The sensitivity analysis was also done for hydrogen efficiency, heat recovery of each heat exchanger, and the cost of each fuel. Finally, LPG was estimated as the most economical fuel in Korean market.

Comparison of absolute and relative thermal QST thresholds In the orofacial region of the young Korean women (젊은 한국 여성의 구강안면영역에서 절대적 온도역치와 상대적 온도역치간의 비교)

  • Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.4
    • /
    • pp.367-372
    • /
    • 2013
  • To diagnose sensory nerve damage, patient values for thermal stimuli as quantitative sensory test (QST) can be compared with the values of the general population (absolute reference data) or to values measured at contralateral unaffected side (relative reference data). It is well know that relative reference data are more sensitive for detecting sensory abnormality than absolute reference data. However it is still lack of the studies for comparisons between relative and absolute data. This study aimed to evaluate the validity of relative reference data and compare the sensitivities of the two approaches in the orofacial region. In 19 young Korean women as normal subjects, quantitative somatosensory thermotest were done in the forehead, cheek, mentum, lower lip and tongue tip bilaterally. After we get the standard deviations (SD) of average reference data and relative reference data, the ratios SD absolute data/SD relative data were calculated. Our study showed that relative reference data for side to side comparisons in the same patient have the high ratios than the absolute reference data, i.e. the side to side comparisons with relative reference data exhibit gain in sensitivity in assessment of sensory abnormality.

Development of FURA Code and Application for Load Follow Operation (FURA 코드 개발과 부하 추종 운전에 대한 적용)

  • Park, Young-Seob;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.88-104
    • /
    • 1988
  • The FUel Rod Analysis(FURA) code is developed using two-dimensional finite element methods for axisymmetric and plane stress analysis of fuel rod. It predicts the thermal and mechanical behavior of fuel rod during normal and load follow operations. To evaluate the exact temperature distribution and the inner gas pressure, the radial deformation of pellet and clad, the fission gas release are considered over the full-length of fuel rod. The thermal element equation is derived using Galerkin's techniques. The displacement element equation is derived using the principle of virtual works. The mechanical analysis can accommodate various components of strain: elastic, plastic, creep and thermal strain as well as strain due to swelling, relocation and densification. The 4-node quadratic isoparametric elements are adopted, and the geometric model is confined to a half-pellet-height region with the assumption that pellet-pellet interaction is symmetrical. The pellet cracking and crack healing, pellet-cladding interaction are modelled. The Newton-Raphson iteration with an implicit algorithm is applied to perform the analysis of non-linear material behavior accurately and stably. The pellet and cladding model has been compared with both analytical solutions and experimental results. The observed and predicted results are in good agreement. The general behavior of fuel rod is calculated by axisymmetric system and the cladding behavior against radial crack is used by plane stress system. The sensitivity of strain aging of PWR fuel cladding tube due to load following is evaluated in terms of linear power, load cycle frequency and amplitude.

  • PDF

Large-Area Synthesis of High-Quality Graphene Films with Controllable Thickness by Rapid Thermal Annealing

  • Chu, Jae Hwan;Kwak, Jinsung;Kwon, Tae-Yang;Park, Soon-Dong;Go, Heungseok;Kim, Sung Youb;Park, Kibog;Kang, Seoktae;Kwon, Soon-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.130.2-130.2
    • /
    • 2013
  • Today, chemical vapor deposition (CVD) of hydrocarbon gases has been demonstrated as an attractive method to synthesize large-area graphene layers. However, special care should be taken to precisely control the resulting graphene layers in CVD due to its sensitivity to various process parameters. Therefore, a facile synthesis to grow graphene layers with high controllability will have great advantages for scalable practical applications. In order to simplify and create efficiency in graphene synthesis, the graphene growth by thermal annealing process has been discussed by several groups. However, the study on growth mechanism and the detailed structural and optoelectronic properties in the resulting graphene films have not been reported yet, which will be of particular interest to explore for the practical application of graphene. In this study, we report the growth of few-layer, large-area graphene films using rapid thermal annealing (RTA) without the use of intentional carbon-containing precursor. The instability of nickel films in air facilitates the spontaneous formation of ultrathin (<2~3 nm) carbon- and oxygen-containing compounds on a nickel surface and high-temperature annealing of the nickel samples results in the formation of few-layer graphene films with high crystallinity. From annealing temperature and ambient studies during RTA, it was found that the evaporation of oxygen atoms from the surface is the dominant factor affecting the formation of graphene films. The thickness of the graphene layers is strongly dependent on the RTA temperature and time and the resulting films have a limited thickness less than 2 nm even for an extended RTA time. The transferred films have a low sheet resistance of ~380 ${\Omega}/sq$, with ~93% optical transparency. This simple and potentially inexpensive method of synthesizing novel 2-dimensional carbon films offers a wide choice of graphene films for various potential applications.

  • PDF

A Generalized Model for the Prediction of Thermally-Induced CANDU Fuel Element Bowing (CANDU 핵연료봉의 열적 휨 모형 및 예측)

  • Suk, H.C.;Sim, K-S.;Park, J.H.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.811-824
    • /
    • 1995
  • The CANDU element bowing is attributed to actions of both the thermally induced bending moments and the bending moment due to hydraulic drag and mechanical loads, where the bowing is defined as the lateral deflection of an element from the axial centerline. This paper consider only the thermally-induced bending moments which are generated both within the sheath and the fuel and sheath by an asymmetric temperature distribution with respect to the axis of an element The generalized and explicit analytical formula for the thermally-induced bending is presented in con-sideration of 1) bending of an empty tube treated by neglecting the fuel/sheath mechanical interaction and 2) fuel/sheath interaction due to the pellet and sheath temperature variations, where in each case the temperature asymmetries in sheath are modelled to be caused by the combined effects of (i) non-uniform coolant temperature due to imperfect coolant mixing, (ii) variable sheath/coolant heat transfer coefficient, (iii) asymmetric heat generation due to neutron flux gradients across an element and so as to inclusively cover the uniform temperature distributions within the fuel and sheath with respect to the axial centerline. As the results of the sensitivity calculations of the element bowing with the variations of the parameters in the formula, it is found that the element bowing is greatly affected relatively with the variations or changes of element length, sheath inside diameter, average coolant temperature and its variation factor, pellet/sheath mechanical interaction factor, neutron flux depression factor, pellet thermal expansion coefficient, pellet/sheath heat transfer coefficient in comparison with those of other parameters such as sheath thickness, film heat transfer coefficient, sheath thermal expansion coefficient and sheath and pellet thermal conductivities.

  • PDF

An Analysis Method on Injury Symptoms Utilizing Infrared Thermal Imaging under the Freezing Stress of Hedera helix L. (헤데라 헬릭스 식물의 적외선 열영상에 의한 저온 및 한풍피해에 관한 연구)

  • Seong, Bu-Geun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.173-179
    • /
    • 2012
  • The experiments, which analyze the injury symptoms and diagnose growth conditions utilizing IRVT and analyzing each parts of H. helix L., had been held under a low temperature. Greenhouse and outdoor growing Genus hedera had been prepared and compared with each Genus hedera's peak and bottom leaves' surface temperature under the experimental categories $-6^{\circ}C$ and $-12^{\circ}C$. As results, analyzing the surface thermal property of peak part leaves' of outdoor growing Genus hedera, at experimental categories $-6^{\circ}C$, $-12^{\circ}C$ were ranged from $-2^{\circ}C{\sim}-7^{\circ}C$ and $-2^{\circ}C{\sim}-15^{\circ}C$. On the other hand, the surface thermal property of bottom part leaves at experimental categories $-6^{\circ}C$, $-12^{\circ}C$ were ranged $-2^{\circ}C{\sim}-11^{\circ}C$ and $-1^{\circ}C{\sim}-12^{\circ}C$. It appears that the thermal properties of leaves' surface on $-6^{\circ}C$ peaks and $-12^{\circ}C$ bottoms were more broadband than bottoms and peaks. It means that the peaks were more sensitive than bottoms, as like $-2^{\circ}C{\sim}-15^{\circ}C$, $-1{\sim}-12^{\circ}C$. Moreover, as similar results had seen to leaves surface temperature added to cold wind conditions. How the cold wind damaged the outdoor growing Genus hedera, analyzed the surface thermal property by IRVT data under $0^{\circ}C$, $-2^{\circ}C$, $-4^{\circ}C$ condition, it resulted to $-6.2^{\circ}C$, $-6.8^{\circ}C$, $-7.5^{\circ}C$. It appeared more $3.5{\sim}6.2^{\circ}C$ low temperature than experimental setting point. In addition, each parts thurmal property of peaks and bottoms was not similar, it referred to each parts' sensitivities of low temperature were different on the peak and bottom leaves surface temperature.

Infrared Thermography in the Assessment of Temporomandibular Joint Dysorder (측두하악장애에서의 적외선 체열 촬영 검사의 유용성)

  • Nahm, Sahngun Francis;Koo, Mi Suk;Kim, Yang Hyun;Suh, Jeong Hun;Shin, Hwa Yong;Choi, Yong Min;Kim, Yong Chul;Lee, Sang Chul;Lee, Pyung Bok
    • The Korean Journal of Pain
    • /
    • v.20 no.2
    • /
    • pp.163-168
    • /
    • 2007
  • Background: Temporomandibular joint disorder (TMD) is a group of musculoskeletal conditions characterized by pain in the pre-auricular area, limitation of jaw movement and palpable muscle tenderness. Thermography is a nonionizing, noninvasive diagnostic alternative for the evaluation of TMD. This study was conducted to evaluate the usefulness of thermography in the assessment of TMD. Methods: Thermography was conducted on the 61 patients who had been diagnosed with TMD, and on the 34 normal symptom-free volunteers. The temperature differences between opposite sides of the temporomandibular joint (${\Delta}T_{TMJ}$) and the masseter muscle (${\Delta}T_{MST}$) were calculated. The sensitivity and specificity of thermography was calculated at the cut off values of 0.2, 0.3, and $0.4^{\circ}C$. Results: In the patient group, the ${\Delta}T_{TMJ}$ was $0.42{\pm}0.38^{\circ}C$ and the ${\Delta}T_{MST}$ was $0.38{\pm}0.33^{\circ}C$, whereas in the control group the ${\Delta}T_{TMJ}$ was $0.10{\pm}0.07^{\circ}C$ and the ${\Delta}T_{MST}\;0.15{\pm}0.10^{\circ}C$. In addition, the patient group demonstrated a significantly lower level of thermal symmetry than the control group (P < 0.001) in both the temporomandibular joints and the masseter muscles. The sensitivity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 67.2, 49.2, and 42.6% in the temporomandibular joint (TMJ) and 60.7, 49.2 and 37.7% in the masseter muscle, respectively. The specificity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 88.2, 100, and 100% in the TMJ and 61.8, 91.2 and 100% in the masseter muscles, respectively. The accuracy of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 74.7, 67.4, and 63.2% in TMJ and 61.1, 64.2 and 60.0% in the masseter muscles, respectively. Conclusions: Temperature differences exist between the opposite sides of the TMD and masseter muscles in patients with TMD. Although the sensitivity of thermography in the diagnosis of TMD is low, it has high specificity in the evaluation of TMD, and is therefore applicable to patients with TMD.

A study on electrical response property of photoconductor film for x-ray imaging sensor (X선 영상센서 적용을 위한 광도전체 필름의 전기적 응답특성 연구)

  • Kang, Sang-Sik;Kim, Chan-Wook;Lee, Mi-Hyun;Lee, Kwang-Ok;Moon, Yong-Soo;An, Sung-A;No, Ci-Chul;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.29-33
    • /
    • 2009
  • Recently, the compound materials(a-Se, $HgI_2$, PbO, CdTe, $PbI_2$, etc.) that are used in flat panel x-ray imager have been studied for digital x-ray imaging. In this paper, the signal detection properties of $HgI_2$ and a-Se conversion layer, are compared. The thick $HgI_2$ film is fabricated by special particle-in-binder method and the conventional vacuum thermal evaporation is used for a deposition of a-Se film. And an electrical characteristic measurements were investigated about leakage current, signal response property and x-ray sensitivity. From the experimental results show that the $HgI_2$ film has a low operation voltage and high signal generation than that of a-Se.

  • PDF

Study on the Enhanced Specific Surface Area of Mesoporous Titania by Annealing Time Control: Gas Sensing Property (열처리 시간에 따른 메조기공 타이타니아의 비표면적 향상 연구: 가스센싱 특성 변화)

  • Hong, M.-H.;Park, Ch.-S.;Park, H.-H.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.2
    • /
    • pp.21-26
    • /
    • 2015
  • Mesoporous ceramic materials were applied in various fields such as adsorbent and gas sensor because of low thermal conductivity and high specific surface area properties. This structure could be divided into open-pore structure and closed-pore structure. Although closed-pore structure mesoporous ceramic materials have higher mechanical property than open-pore structure, it has a restriction on the application because the increase of specific surface area is limited. So, in this work, specific surface area of closed-pore structure $TiO_2$ was increased by anneal time. As increased annealing time, crystallization and grain growth of $TiO_2$ skeleton structured material in mesoporous structure induced a collapse and agglomeration of pores. Through this pore structural change, pore connectivity and specific surface area could be enhanced. After anneal for 24 hrs, porosity was decreased from 36.3% to 34.1%, but specific surface area was increased from $48m^2/g$ to $156m^2/g$. CO gas sensitivity was also increased by about 7.4 times due to an increase of specific surface area.