• Title/Summary/Keyword: Thermal Sensitivity

Search Result 636, Processing Time 0.022 seconds

Sensitivity Enhancement of Shadow Moiré Technique for Warpage Measurement of Electronic Packages (반도체 패키지의 굽힘변형 측정을 위한 그림자 무아레의 감도향상 기법연구)

  • Lee, Dong-Sun;Joo, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.3
    • /
    • pp.57-65
    • /
    • 2015
  • Electronic packages consist of various materials, and as temperature changes, warpage occurs because of the difference in coefficient of thermal expansion. Shadow $moir{\acute{e}}$ is non-contact, whole field measurement technique for out-of-plane displacement. However, the technique has low sensitivity above $50{\mu}m/fringe$, it is not adequate for the warpage measurement in some circumstance. In this paper, by applying phase shifting process to the traditional shadow $moir{\acute{e}}$, measurement system having enhanced sensitivity of $12.5{\mu}m/fringe$ is constructed. Considering Talbot effect, the measurement is carried out in the half Talbot area. Shadow fringe pattern having four times enhanced sensitivity is obtained by the image process with four shadow fringes. The measurement technique is applied to the fibered package substrate and coreless package substrate for measuring warpages at room temperature and at about $100^{\circ}C$.

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.

A Numerical Study on the Pressure Drop and Heat Transfer in the Hot Channel of Plate heat Exchanger with Chevron Shape (쉐브론 형상 판형 열교환기의 고온 채널에서의 압력손실 및 열전달 특성에 관한 해석 연구)

  • Sohn, Sangho;Shin, Jeong-Heon;Kim, Jungchul;Yoon, Seok Ho;Lee, Kong Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.175-185
    • /
    • 2018
  • This research investigates the internal flow and heat transfer in a plate heat exchanger with chevron shape by utilizing the computational fluid dynamics (CFD) software. The basic unit of the plate heat exchanger is generally composed of a hot channel, an intermediate chevron plate, and a cold channel. Several studies have reported experimental and numerical simulation of heat transfer and pressure drop. This study focused on the detailed numerical simulation of flow and heat transfer in the complicated chevron shape channel. The long chevron plate was designed to include 16 chevron patterns. For proper mesh resolution, the number of cells was determined after the grid sensitivity test. The working fluid is water, and its properties are defined as a function of temperature. The Reynolds number ranges from 900 to 9,000 in the simulation. A realizable $k-{\varepsilon}$ model and non-equilibrium wall function are properly considered for the turbulent flow. The friction factors and heat transfer coefficient are validated by comparing them with existing empirical correlations, and other patterned flow phenomena are also investigated.

Development of a thermal-hydraulic analysis code for once-through steam generators using straight tubes for SMRs (일체형 원자로용 관류식 직관형 증기발생기 열수력 해석 코드 개발)

  • Park, Youngjae;Kim, Iljin;Kang, Kyungjun;Kang, Hanok;Kim, Youngin;Kim, Hyungdae
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.91-102
    • /
    • 2015
  • A thermal-hydraulic design and performance analysis computer code for a once-through steam generator using straight tubes is developed. To benchmark the developed physical models and computer code, an once-through steam generator developed by other designer is simulated and the calculated results are compared with the design data. Also, the same steam generator is analyzed with the best-estimate thermal-hydraulic system code, MARS, for the code-to-code validation. The overall characteristics of heat transfer area, pressure and temperature distributions calculated by the developed code show general agreements with the published design data as well as the analysis results of MARS. It is demonstrated that the developed code can be utilized for diverse purposes, such as, sensitivity analyses and optimum thermal design of a once-through steam generator.

$H^{\infty}$ Controller Design for RTP System using Weighted Mixed Sensitivity Minimization (하중 혼합감도함수를 이용한 RTP 시스템의 $H^{\infty}$ 제어기 설계)

  • Lee, Sang-Kyung;Kim, Jong-Hae;Oh, Do-Chang;Park, Hong-Bae
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.6
    • /
    • pp.55-65
    • /
    • 1998
  • In industrial fields, RTP(rapid thermal processing) system is widely used for improving the oxidation and the annealing in semiconductor manufacturing process. The main control factors are temperature control of wafer and uniformity in the wafer. In this paper, we propose an $H^{\infty}$ controller design of RTP system satisfying robust stability and performance using weighted mixed sensitivity miniimization and loop shaping technique. And we need reduction technique because of the difficulty of implementation with the obtained high order controller for original model and reduced models, namely, Hankel, square-root balanced, and Schur balanced methods. An example is proposed to show the validity of the proposed method.

  • PDF

A Study on Significant Parameters for Efficient Design of Open-loop Groundwater Heat Pump (GWHP) Systems (개방형 지열시스템의 효율적 설계를 위한 영향인자에 대한 연구)

  • Park, Byeong-Hak;Joun, Won-Tak;Lee, Bo-Hyun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.41-50
    • /
    • 2015
  • Open-loop groundwater heat pump (GWHP) system generally has benefits such as a higher coefficient of performance (COP), lower initial cost, and flexible system size. The hydrogeological conditions in Korea have the potential to facilitate the use of the GWHP system because a large number of monitoring wells show stable groundwater temperatures, shallow water levels, and high well yields. However, few studies have been performed in Korea regarding the GWHP system and the most studies among them dealt with Standing Column Well (SCW). Because the properties of the aquifer have an influence on designing open-loop systems, it is necessary to perform studies on various hydrogeological settings. In this study, the hydrogeological and thermal properties were estimated through various tests in the riverside alluvial layer where a GWHP system was installed. Under different groundwater flow velocities and pumping and injection rates, a sensitivity analysis was performed to evaluate the effect of such properties on the design of open-loop systems. The results showed that hydraulic conductivity and thermal dispersivity of the aquifer are the most sensitive parameters in terms of performance and environmental aspects, and sensitivities of the properties depend on conditions.

RELAP5/MOD3 Analysis for Hydraulic Load Calculation of the SEBIM POSRV Discharge Riping System (SEBIM POSRV 방출배관계통의 수력학적 하중계산을 위한 RELAP5 / MOD3 분석)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.225-236
    • /
    • 1994
  • The sudden discharge of the loop seal water, which is present upstream of the SEBIM POSRV, creates large momentum and inertia forces on the downstream of the discharge piping system. This study provides the procedures and results of analysis of the thermal-hydraulic transient in the SEBIM POSRV discharge piping during the valve opening. The analysis is peformed by RELAP5/MOD3. The appropriate modeling of the discharge piping system, SEBIM POSRV opening characteristics, and loop seal water discharge for the RELAP5/MOD3 analysis is suggested. Also performed is the sensitivity study for the selection of proper options for the junction and volume control. flags. The analysis results demonstrate the adequacy of the RELAP5/HOD3 for the thermal-hydraulic transient analysis of the loop seal water discharge of the SEBIM POSRV discharge piping system. From the sensitivity analysis results, it is shown that the smooth area change option with reasonable geometric pressure drop distribution, non-equilibrium option, and proper time step should be selected for loop seal water discharge analysis.

  • PDF

Silicon Capacitive Pressure Sensor for Low Pressure Measurements (저 압력 측정을 위한 실리콘 용량형 압력센서)

  • Seo, Hee-Don;Lee, Youn-Hee;Park, Jong-Dae;Choi, Se-Gon
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.19-27
    • /
    • 1993
  • Capacitive pressure sensor for low pressure measurements has been fabricated by using $n^{+}$ epitaxial layer electrochemical etching stop and glass-to-silicon electrostatic bonding technique. The sensor had hybrid configuration of a sensor chip, which consists of sensor capacitor and reference capacitor, and two output signal detection IC chips. A fabricated sensor, with a $1.0{\times}1.0 mm^{2}$ square size and a $10{\mu}m$ thick flat diaphragm, showed a 7.1 pF zero pressure capacitance, and 5.2 % F.S, sensitivity in 10 KPa pressure range. By using a capacitance to voltage converter, the thermal zero shift of 0.051 %F.S./$^{\circ}C$ and the thermal sensitivity shift of 0.12 %F.S./$^{\circ}C$ for temperature range of $5{\sim}45^{\circ}C$ were obtained.

  • PDF

Inverse Association and Differences in the Distribution of Metabolic Syndrome and Cold Hypersensitivity in the Hands and Feet According to Sasang Constitution (사상체질에 따른 대사증후군과 수족냉증 분포 차이와 역상관관계)

  • Bae, Kwang-Ho;Park, Ki-Hyun;Lee, Siwoo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2022
  • Objectives This study aimed to examine the differences in the distribution of metabolic syndrome(MetS) and cold hypersensitivity in the hands and feet(CHHF) according to Sasang constitution, and to determine whether CHHF and MetS have an inverse association. Methods MetS and its components, CHHF, Sasang constitution data from 1,998 participants in the Korean medicine Daejeon Citizen Cohort study(KDCC) were obtained. The participants were divided into a non-CHHF(n = 1,270, 63.6%), intermediate(n = 220, 11.0%) and CHHF(n = 508, 25.4%) group according to the thermal sensitivity questionnaire. Sasang constitution was diagnosed by Korea Sasang Constitutional Diagnostic Questionnaire(KS-15). One-way ANOVA and the chi-square test were used for participants' general characteristics and thermal sensitivity and MetS related factors. ANCOVA and logistic regression were used to compare the differences and the odds ratios(ORs) for MetS and its components. Results The MetS and CHHF prevalence rates of the Taeeumin, Soeumin, and Soyangin were 27.6%, 3.8%, 7.7%, and 18.3%, 42.3%, 26.4% respectively. The ANCOVA for MetS components showed that the waist circumference was significantly lower in the CHHF group as compared to the non-CHHF group in total and Soyangin. The logistic regression for MetS prevalence showed that CHHF had a significant inverse association in total(OR = 0.611) and Taeeumin(OR = 0.521). Conclusions The MetS prevalence had the highest in Taeeumin, followed by Soyangin and Soeumin, while the prevalence of CHHF was highest in Soeumin, followed by Soyangin and Taeeumin. In addition, it was confirmed that CHHF and MetS had an inverse association independently.

Detection of a Thermal Stable-Soluble Protein (TSSP) as a Marker of Peanut Adulteration Using a Highly Sensitive Indirect Enzyme-Linked Immunosorbent Assay based on Monoclonal Antibodies

  • Sol-A Kim;Sazzad Hossen Toushik;Jeong-Eun Lee;Won-Bo Shim
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.9
    • /
    • pp.1170-1178
    • /
    • 2023
  • Food allergy represents a severe problem for many societies, including sensitive populations, academies, health authorities, and the food industry. Peanut allergy occupies a special place in the food allergy spectrum. To prevent consumption by consumers suffering from a peanut allergy, a rapid and sensitive detection method is essential to identify unintended peanut adulteration in processed foods. In this study, we produced four monoclonal antibodies (MAbs; RO 3A1-12, PB 4C12-10, PB 5F9-23, and PB 6G4-30) specific to thermo-stable and soluble proteins (TSSPs) of peanut and developed an enzyme-linked immunosorbent assay (ELISA) based on the MAbs. Among them, PB 5F9-23 MAb was firmly bound to Ara h 1, and other MAbs strongly reacted to Ara h 3 in the Western blot analysis. An antibody cocktail solution of the MAbs was used to enhance the sensitivity of an indirect ELISA, and the limit of detection of the indirect ELISA based on the antibody cocktail solution was 1 ng/ml and improved compared to the indirect ELISA based on the single MAb (11 ng/ml). The cross-reaction analysis revealed the high specificity of developed MAbs to peanut TSSPs without cross-reaction to other food allergens, including nuts. Subsequently, analyzing processed foods by indirect ELISA, all foods labeled as containing peanuts in the product description were confirmed to be positive. The results indicate that the developed antibodies exhibit high specificity and sensitivity to peanuts and can be used as bio-receptors in immunoassays or biosensors to detect intentional or unintentional adulteration of peanuts in processed foods, particularly heat-processed foods.