• 제목/요약/키워드: Thermal Resolution

검색결과 465건 처리시간 0.028초

Inspection of Calandria Reactor Surface of Wolsung Nuclear Power Plant using Thermal Infrared Camera mounted on the Mobile Robot KAEROT/m2

  • Cho, Jai-Wan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.578-578
    • /
    • 2002
  • Thermal infrared imaging is a highly promising technology for condition monitoring and predictive maintenance of electronic, electrical and mechanical elements in nuclear power plants. However, conventional low-cost infrared imaging systems suffer from poor spatial resolution compared to commercial CCD cameras. This paper describes an approach to enhance inspection performances for calandria reactor area of Wolsung nuclear power plant through the technique of superimposing thermal infrared image into real CCD image. In the occurrence of thermal abnormalities on observation points and areas of calandria reactor area, unusual hot image taken from thermal infrared camera is mapped upon real CCD image. The performance of the technique has been evaluated in the experiment carried out at Wolsung nuclear power plant in the overhaul period. The results show that localizations of thermal abnormalities on calandria reactor face can be estimated accurately.

  • PDF

방조제 건설에 의한 해수면 온도 변화 추정 (Estimating Sea Surface Temperature Change after Tide Embankment Construction using Landsat Data)

  • 신동훈;이규석
    • 한국지리정보학회지
    • /
    • 제9권4호
    • /
    • pp.224-232
    • /
    • 2006
  • 본 연구는 Landsat Thematic Mapper (TM) 영상의 열적외선 (Thermal Infrared: TIR) 밴드 자료를 이용하여 시화호와 그 주변지역의 해수면 온도 (SST: sea surface temperature)를 검출하고, 시화방조제 공사 후의 토지피복변화를 파악하기 위해 수행되었다. 해수면 온도의 측정은 해양체계 뿐만 아니라 해양과 대기 사이의 열적인 경계범위 연구에 있어 중요하다. 1970년대 이후, AVHRR (advanced very high resolution radiometer)과 Landsat TM (Thematic Mapper)과 같은 인공위성 영상의 원격탐사기법을 이용한 해수면 온도의 추출이 이루어졌다. 그러나 AVHRR 영상은 우리나라의 서해안 지역과 같은 매우 복잡한 해안선을 가지고 있는 지역에서는 조악한 공간 해상도로 인해 해수표면온도 추출에 한계가 있다. Landsat TM 위성영상은 본 연구지역과 같이 복잡하고 좁은 해안지역의 해수면 온도 추출에 유용하게 사용된다고 판단된다.

  • PDF

CCD와 적외선 열영상의 다중영상을 이용한 월성원자력발전소의 칼란드리아 전면부 점검 (Inspection of Calandria Reactor Area of Wolsung NPP using Thermal Infrared and CCD Images)

  • 조재완;최영수;김창회;서용칠;김승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.711-714
    • /
    • 2002
  • Thermal infrared camera have poor image qualities compared to commercial CCD cameras, as in contrast, brightness, and. resolution. To compensate the poor Image quality problems associated with the thermal infrared camera, the technique of superimposing thermal infrared image into real ccd image is proposed. The mobile robot KAEROT/m2, loaded with sensor head system at the mast, is entered to monitor leakage of heavy water and thermal abnormality of the calandria reactor area in overhaul period. The sensor head system is composed of thermal infrared camera and cod camera In parallel. When thermal abnormality on observation points and areas of calandria reactor area is occurred, unusual hot image taken from thermal infrared camera is superimposed on real CCD image. In this inspection experiment, more accurate positions of thermal abnormalities on calandria reactor area can be estimated by using technique of mapping thermal infrared image into CCD image, which include characters arranged in MPOQ order.

  • PDF

Thermal and Non-thermal Heat Flow in a Large Crystal Detector for Neutrinoless Double Beta Decay Search

  • Kim, G.B.;Lee, S.J.;Jang, Y.S.;Lee, H.J.;Lee, J.H.;Lee, J.Y.;Lee, M.K.;Yoon, W.S.;Kim, Y.H.
    • Progress in Superconductivity
    • /
    • 제14권2호
    • /
    • pp.87-91
    • /
    • 2012
  • Metallic magnetic calorimeters (MMCs) are one of the most competitive low temperature detector (LTD) readout sensors. They have the advantages of high time resolution, no heat dissipation, and a wide range of operating temperature. We apply MMCs to our neutrinoless double beta decay ($0v{\beta}{\beta}$) search experiment. A $CaMoO_4$ crystal was employed as both a source of $0v{\beta}{\beta}$ and an energy absorber. The crystal was thermally connected to a MMC sensor. We set a simple thermal model for this detector and measured pulse shapes are compared with a numerical solution of the thermal model.

유정압테이블의 위치결정오차요인 분석 (Analysis of Positioning Error Factors in the Hydrostatic Tables)

  • 오윤진;박천홍;이득우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.773-776
    • /
    • 2005
  • In this paper, For improving the positioning accuracy of hydrostatic table, relationship between temperature of atmosphere and thermal characteristics of hydrostatic table is analyzed, and influence of thermal characteristics on positioning accuracy is also analyzed experimentally. From the experimental results, it is confirmed that positioning error and repeatability is $0.21{\mu}m\;and\;0.18{\mu}m$ when the laser scale which has $0.01{\mu}m$ of resolution is used as feed-back unit. and also confirmed that thermal deformation of scale and supporter, which occurs by the temperature variation of atmosphere, works as limit of repeatability in long time operation.

  • PDF

Inspection of Calandria Reactor Area of Wolsung NPP using Thermal Infrared and CCD Images

  • Cho, Jai-Wan;Kim, Chang-Hoi;Seo, Yong-Chil;Park, Young-Soo;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.96.4-96
    • /
    • 2002
  • Thermal infrared imaging is a highly promising technology for condition monitoring and predictive maintenance of electronic, electrical and mechanical elements in nuclear power plants. However, conventional low-cost infrared imaging systems suffer from poor spatial resolution compared to commercial CCD cameras. This paper describes an approach to enhance inspection performances for calandria reactor area of Wolsung nuclear power plant through the technique of superimposing thermal infrared image into real CCD image. In the occurrence of thermal abnormalities on observation points and areas of calandria reactor area, unusual hot image taken from thermal infrared camera is mapped upon re...

  • PDF

320x240 적외선 배열검출기를 이용한 고분해능 열상 신호처리기 구현 (High Resolution Electronic Processor Design for Thermal Imager with 320x240 Staring Array Infrared Detector)

  • 홍석민;유위경;윤은숙
    • 한국군사과학기술학회지
    • /
    • 제9권2호
    • /
    • pp.111-117
    • /
    • 2006
  • This paper describes the design principles and methods of electronic processor for thermal imager with 320$\times$240 staring array infrared detector. For the detector's nonuniformity correction and excellent image quality, we have designed the multi-point correction method using the defocusing technique of the optics. And to enhance the image of low contrast and improve the detection capability, the new technique of histogram processing has been designed. Through these image processing techniques, we have developed the high quality thermal imager and acquired a satisfactory thermal image. The result of MRTD(Minimum Resolvable Temperature Difference) is $0.1^{\circ}C$ at 4cycles/mard.

흘로그램 간섭계를 이용한 광픽업 베이스의 미소 열변형 측정 (Measurement of Micro Thermal Deformation of Optical Pick-up Base Using Holographic Interferometry)

  • 서영민;강신일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.191-194
    • /
    • 2002
  • In optical pick-up, optical components such as objective lens, collimator, mirror, laser diode and photo diode are mounted on the pick-up base. These components must keep their original position during operation for proper transmittance of information from laser diode to optical disk and back to photo diode. However, micro thermal deformation of pick-up base which is induced by thermal environment during operation can deteriorate the performance of optical pick-up. Therefore, it is important to measure and analyze the thermal deformation behavior of pick-up base under thermal environment. In the present study, a measurement system using holographic interferometry was designed to measure micro thermal deformation of pick up base. The measurement system was verified by using the deformation of cantilever with prescribed motion actuated by PZT with 1 nm resolution. Interferometric measurement was compared quantitatively with that induced by PZT actuator. Finally, micro thermal deformation of pick-up base under actual thermal environment was measured using the present holographic interferometry and the results were analysed.

  • PDF