• 제목/요약/키워드: Thermal Power Generation

검색결과 626건 처리시간 0.027초

부하 변화에 따른 리니어엔진의 동적·연소특성에 대한 연구 (A Study About Effects of Changed Load on Dynamic·Combustion Characteristics of Linear Engine)

  • 이재완;임옥택;김강출
    • 한국수소및신에너지학회논문집
    • /
    • 제24권3호
    • /
    • pp.206-215
    • /
    • 2013
  • A linear engine has advantages in terms of volume and weight, because there are no rotating parts. Thus, it is considered that linear engines might be suitable in hybrid vehicles. However, the linear engine has challenges in terms of the engine ignition timing and efficiency, so the engine has not been commercialized yet. In this study, the dynamic and combustion characteristics of the linear engine might be specified by various loads which are changed by conductance. The engine used in this experiment consists of two combustion chambers, four compressors, two linear alternators and a mover with a piston head and magnets. The way fuel is supplied in the experiment is by propane fuel being mixed with air in the carburetor, then being delivered into combustion cylinders via compressors. In the experiment, conductance is altered from 0.04 to 0.16mho, and the ignition timing is ahead by just 5.0mm from the maximum stroke. As a result of the experiment, frequency, stroke, input calories and maximum pressure are decreased when the conductance is increased. Meanwhile, IMEP, generation efficiency and electric power are increased when the conductance is increased. Therefore, it might confirm that high conductance generates more efficient electric power, but that thermal efficiency is the highest in the state of 0.08mho.

DC Magnetron Sputter로 제조된 Pt 박막의 특성 (The characteristics of Pt thin films prepared by DC magnetron sputter)

  • 나동명;김영복;박진성
    • 센서학회지
    • /
    • 제16권2호
    • /
    • pp.159-164
    • /
    • 2007
  • Thin films of platinum were deposited on a $Al_{2}O_{3}/ONO(SiO_{2}-Si_{3}N_{4}-SiO_{2})/Si$-substrate with an 2-inch Pt(99.99 %) target at room temperature for 20, 30 and 60 min by DC magnetron sputtering, respectively X-ray diffract meter (XRD) was used to analyze the crystallanity of the thin films and field emission scanning electron microscopy (FE-SEM) was employed for the investigation on crystal growth. The densification and the grain growth of the sputtered films have a considerable effect on sputtering time and annealing temperatures. The resistance of the Pt thin films was decreased with increasing deposition time and sintering temperature. Pt micro heater thin film deposited for 60 min by DC magnetron sputtering on an $Al_{2}O_{3}$/ONO-Si substrate and annealed at $600^{\circ}C$ for 1 h in air is found to be a most suitable micro heater with a generation capacity of $350^{\circ}C$ temperature and 645 mW power at 5.0 V input voltage. Adherence of Pt thin film and $Al_{2}O_{3}$ substrate was also found excellent. This characteristic is in good agreement with the uniform densification and good crystallanity of the Pt film. Efforts are on progress to find the parameters further reduce the power consumption and the results will be presented as soon as possible.

An Application of Realistic Evaluation Methodology for Large Break LOCA of Westinghouse 3 Loop Plant

  • Choi, Han-Rim;Hwang, Tae-Suk;Chung, Bub-Dong;Jun, Hwang-Yong;Lee, Chang-Sub
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.513-518
    • /
    • 1996
  • This report presents a demonstration of application of realistic evaluation methodology to a posturated cold leg large break LOCA in a Westinghouse three-loop pressurized water reactor with 17$\times$17 fuel. The new method of this analysis can be divided into three distinct step: 1) Best Estimate Code Validation and Uncertainty Quantification 2) Realistic LOCA Calculation 3) Limiting Value LOCA Calculation and Uncertainty Combination RELAP5/MOD3/K [1], which was improved from RELAP5/MOD3.1, and CONTEMPT4/MOD5 code were used as a best estimate thermal-hydraulic model for realistic LOCA calculation. The code uncertainties which will be determined in step 1) were quantified already in previous study [2], and thus the step 2) and 3) for plant application were presented in this paper. The application uncertainty parameters are divided into two categories, i.e. plant system parameters and fuel statistical parameters. Single parameter sensitivity calculations were performed to select system parameters which would be set at their limiting value in Limiting Value Approach (LVA) calculation. Single run of LVA calculation generated 27 PCT data according to the various combinations of fuel parameters and these data provided input to response surface generation. The probability distribution function was generated from Monte Carlo sampling of a response surface and the upper 95$^{th}$ percentile PCT was determined. Break spectrum analysis was also made to determine the critical break size. The results show that sufficient LOCA margin can be obtained for the demonstration NPP.

  • PDF

폴리에틸렌으로 피복된 전선화염의 전파에 교류전기장이 미치는 영향에 관한 실험적 연구 (Experimental Study on the Effects of AC Electric Fields on Flame Spreading over Polyethylene-insulated Electric-Wire)

  • 진영규;김민국;박정;정석호;김태형;박종호
    • 대한기계학회논문집B
    • /
    • 제34권11호
    • /
    • pp.1015-1025
    • /
    • 2010
  • 본 연구는 교류전기장이 인가된 전선에서의 화염전파특성에 전기장이 미치는 영향에 대한 실험적 연구이다. 폴리에틸렌으로 피복된 전선에서 인가된 교류전압과 주파수에 따라 화염전파율을 도출하였다. 그리고 화염전파는 선형적 화염 전파와 비선형적으로 가속된 화염 전파로 구분되어졌다. 이것은 전선에 인가된 교류전기장에 따라 형성된 전기장 세기의 축방향 분포가 원인이 된다. 그리고 기울어진 전선화염의 화염전파율이 상대적으로 높게 나타났다. 이러한 현상은 온도균형메커니즘으로 설명이 가능하다.

DEVELOPMENT OF A TWO-DIMENSIONAL THERMOHYDRAULIC HOT POOL MODEL AND ITS EFFECTS ON REACTIVITY FEEDBACK DURING A UTOP IN LIQUID METAL REACTORS

  • Lee, Yong-Bum;Jeong, Hae-Yong;Cho, Chung-Ho;Kwon, Young-Min;Ha, Kwi-Seok;Chang, Won-Pyo;Suk, Soo-Dong;Hahn, Do-Hee
    • Nuclear Engineering and Technology
    • /
    • 제41권8호
    • /
    • pp.1053-1064
    • /
    • 2009
  • The existence of a large sodium pool in the KALIMER, a pool-type LMR developed by the Korea Atomic Energy Research Institute, plays an important role in reactor safety and operability because it determines the grace time for operators to cope with an abnormal event and to terminate a transient before reactor enters into an accident condition. A two-dimensional hot pool model has been developed and implemented in the SSC-K code, and has been successfully applied for the assessment of safety issues in the conceptual design of KALIMER and for the analysis of anticipated system transients. The other important models of the SSC-K code include a three-dimensional core thermal-hydraulic model, a reactivity model, a passive decay heat removal system model, and an intermediate heat transport system and steam generation system model. The capability of the developed two-dimensional hot pool model was evaluated with a comparison of the temperature distribution calculated with the CFX code. The predicted hot pool coolant temperature distributions obtained with the two-dimensional hot pool model agreed well with those predicted with the CFX code. Variations in the temperature distribution of the hot pool affect the reactivity feedback due to an expansion of the control rod drive line (CRDL) immersed in the pool. The existing CRDL reactivity model of the SSC-K code has been modified based on the detailed hot pool temperature distribution obtained with the two-dimensional pool model. An analysis of an unprotected transient over power with the modified reactivity model showed an improved negative reactivity feedback effect.

Laser Thermal Processing System for Creation of Low Temperature Polycrystalline Silicon using High Power DPSS Laser and Excimer Laser

  • Kim, Doh-Hoon;Kim, Dae-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.647-650
    • /
    • 2006
  • Low temperature polycrystalline silicon (LTPS) technology using a high power laser have been widely applied to thin film transistors (TFTs) for liquid crystal, organic light emitting diode (OLED) display, driver circuit for system on glass (SOG) and static random access memory (SRAM). Recently, the semiconductor industry is continuing its quest to create even more powerful CPU and memory chips. This requires increasing of individual device speed through the continual reduction of the minimum size of device features and increasing of device density on the chip. Moreover, the flat panel display industry also need to be brighter, with richer more vivid color, wider viewing angle, have faster video capability and be more durable at lower cost. Kornic Systems Co., Ltd. developed the $KORONA^{TM}$ LTP/GLTP series - an innovative production tool for fabricating flat panel displays and semiconductor devices - to meet these growing market demands and advance the volume production capabilities of flat panel displays and semiconductor industry. The $KORONA^{TM}\;LTP/GLTP$ series using DPSS laser and XeCl excimer laser is designed for the new generation of the wafer & FPD glass annealing processing equipment combining advanced low temperature poly-silicon (LTPS) crystallization technology and object-oriented software architecture with a semistandard graphical user interface (GUI). These leading edge systems show the superior annealing ability to the conventional other method. The $KORONA^{TM}\;LTP/GLTP$ series provides technical and economical benefits of advanced annealing solution to semiconductor and FPD production performance with an exceptional level of productivity. High throughput, low cost of ownership and optimized system efficiency brings the highest yield and lowest cost per wafer/glass on the annealing market.

  • PDF

SP-Creep 시험기법에 의한 9Cr강의 크리프 손상과 경도 특성 (Creep Damage and Hardness Properties for 9Cr Steel by SP-Creep Test Technique)

  • 백승세;류대영;김정기;권일현;정세희;유효선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.105-110
    • /
    • 2001
  • It has recently been raised main issue how solve the problem of insufficient energy. One of the solution is to increase the thermal efficiency of power generation system. For the purpose of high efficiency, it is necessary to increase the steam temperature and pressure. So, the use of modified $9{\sim}12%Cr$ steel having superior creep rupture strength and oxidation resistance is required to endure such severe environment. The evaluation of creep properties of those heat resistance material is very important to secure the reliability of high temperature and pressure structural components. Since creep properties are determined by microstructural change such as carbide precipitation and coarsening, It is certain that there are some relationship between creep properties and hardness affected by microstructure. In this study, SP-Creep ruptured test for newly developed 9Cr steel being used as boiler valve material was performed, and creep properties of the material were evaluated. Also, hardness test were performed and hardness results were related to the creep properties such as LMP and creep strength to verify the availability of SP-Creep test as creep test method.

  • PDF

해수온도변화에 따른 온도차발전시스템의 동적 성능 시뮬레이션 (Dynamic Performance Simulation of OTEC According to Seawater Temperature Change)

  • 임승택;이호생;김현주
    • 동력기계공학회지
    • /
    • 제22권1호
    • /
    • pp.34-40
    • /
    • 2018
  • In this paper, Performance of 1MW OTEC system using R32 with varying seawater temperature range is studied. Steady state cycle is designed and its output and generation efficiency were 1,014kW and 2.72%, respectively. Compared to dynamic cycle, system performance and change during long term operation is studied. The simulation is performed by decreasing surface seawater temperature from $29^{\circ}C$ to $25^{\circ}C$ with 20 minute of reaction time. Dynamic cycle with same condition applied to steady state cycle and it showed output and efficiency of 1,020kW and 2.75% respectively. Seawater temperature decreased from $29^{\circ}C$ and the vapor fraction of refrigerant decreased below 1 at $28^{\circ}C$. While the vapor fraction was above 1, the turbine output decreased by 0.017kW per second. After the seawater temperature reached $26.2^{\circ}C$, the turbine output decreased by 1.03kW per second. However, Driving the turbine below the saturation temperature caused the occurrence of surging and the influx of liquid refrigerant. When the liquid separator having a capacity of 1.0 m3 was used, the flow into the turbine was confirmed after 5 minutes from the first liquid refrigerant coming into the separator.

고분자 전해질 연료전지용 유.무기 복합막의 연구개발동향 (Research Trend of Organic/Inorganic Composite Membrane for Polymer Electrolyte Membrane Fuel Cell)

  • 김득주;남상용
    • 멤브레인
    • /
    • 제22권3호
    • /
    • pp.155-170
    • /
    • 2012
  • 연료전지는 석유엔진과 비교하여 높은 전류밀도와 효율성, 그리고 친환경적이기 때문에 21세기 들어 대체 발전시스템으로서 각광받아왔다. 연료전지 시스템에서 고분자 전해질 막은 핵심부품으로써 현재 Nafion막이 연료전지시스템에서 사용 중이지만 높은 제조단가와 고온에서 낮은 전도도를 가지는 단점을 가지고 있다. 그러므로 많은 학자들이 낮은 제조단가, 높은 물리적 특성들을 달성하기 위한 연구를 진행하여 왔으며 연료전지의 상용화와 동시에 고성능의 연료전지의 개발을 위하여 많은 방법들이 개발되어 왔다. 그중, 유무기 복합막은 유기물과 무기물의 물성을 균일하게 조합할 수 있으므로 잠재성을 가지고 있는 제조방법이다. 본고에서는 다양한 무기물이 사용되어 제조된 유무기 복합막의 연구동향에 대하여 조사하였다.

생태건축 0번지의 자연에너지 효과에 관한 연구 (A Study on the Natural Energy Effect about the Address No.0 of Eco-friendly Architecture)

  • 이시웅;강병호;임상훈;최승희
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.19-25
    • /
    • 2003
  • The Address No.0 of Eco-friendly Architecture offers unique experience for those who visit the place to envisage the future architecture where nature, human and building exist in harmony. It is open to the general public including the students of elementary and secondary schools. This house has been built to provide opportunities for the general public to experience eco-friendly architecture. It's floor area is 42 pyung($140m^2$) and the overall site has the area of 180 pyung($600m^2$). The following illustrates some of its prominent features : ${\bullet}$ Remodeling of a traditional Korean residence ${\bullet}$ Application of passive solar systems ${\bullet}$ Use of clerestory windows and daylighting systems(washroom and machine room) ${\bullet}$ Operation of solar water heaters with flat plate collectors ${\bullet}$ Construction of Biotop(small ecological world) ${\bullet}$ Water circulation for Biotop by photovoltaic(150W) and wind power(400W) generation ${\bullet}$ Outdoor hot water supplied by all-glass evacuated solar tubes. Through this Address No.0 of Eco-friendly Architeture conclusions are as followings. 1. The array of tubes in collector has the best nice in that the number of tube is nine and the tilt angle is the latitude $+20^{\circ}$. 2. The thermal performance of the all-glass solar vacuum collector was excellent than of the flate-plate solar collector. 3. The adaption of new small wind power systems to buildings were proved to produce a profit if it is considered the expense of environment improvement and the wind speed increasing according to rise of building hight.