• Title/Summary/Keyword: Thermal Network

Search Result 530, Processing Time 0.026 seconds

Development of Livestock Monitoring Device based on Biosensors for Preventing Livestock Diseases

  • Park, Myeong-Chul;Jung, Hyon-Chel;Ha, Ok-Kyoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.91-98
    • /
    • 2016
  • Outbreaks of highly contagious livestock diseases can cause direct and indirect economic impacts such as lower productivity of cattle farms, fall in tourism in damaged areas and countries, and decline in exports. They also incur tremendous social costs associated with disease elimination and restoration work. Thus, it is essential to prevent livestock diseases through monitoring and prediction efforts. Currently, however, it is still difficult to provide accurate predictive information regarding occurrences of livestock diseases, because existing cattle health monitoring or forecasting systems are only limited to monitor environmental conditions of livestock barns and check activities of cattle by using a pedometer or thermal image. In this paper, we present a biosensor-based cattle health monitoring system capable of collecting bio-signals of farm animals in an effective way. For the presented monitoring system, we design an integrated monitoring device consisting of a sensing module to measure bio-signals of cattle such as the heartbeat, the breath rate and the momentum, as well as a Zigbee module designed to transmit the biometric data based on Wireless Sensor Network (WSN). We verify the validity of the monitoring system by the comparison of the correlations of designed device with a commercial ECG equipment through analyzing the R-peak of measured signals.

Input Variable Decision of the Predictive Model for the Optimal Starting Moment of the Cooling System in Accommodations (숙박시설 냉방 시스템의 최적 작동 시점 예측 모델 개발을 위한 입력 변수 선정)

  • Baik, Yong Kyu;Yoon, Younju;Moon, Jin Woo
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: This study aimed at finding the optimal input variables of the artificial neural network-based predictive model for the optimal controls of the indoor temperature environment. By applying the optimal input variables to the predictive model, the required time for restoring the current indoor temperature during the setback period to the normal setpoint temperature can be more precisely calculated for the cooling season. The precise prediction results will support the advanced operation of the cooling system to condition the indoor temperature comfortably in a more energy-efficient manner. Method: Two major steps employing the numerical computer simulation method were conducted for developing an ANN model and finding the optimal input variables. In the first process, the initial ANN model was intuitively determined to have input neurons that seemed to have a relationship with the output neuron. The second process was conducted for finding the statistical relationship between the initial input variables and output variable. Result: Based on the statistical analysis, the optimal input variables were determined.

An Impact Analysis of Community Energy System (CES) on The Grid (지역 에너지 시스템(CommunityEnergysystem)의 개통 연계 운전 특성)

  • Park Y. U.;Kim K. H.;Jang S. I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.120-122
    • /
    • 2004
  • This paper analyse impacts of Community Energy System (CES) on the grid during transition periods for integrating of the CES and the grid. In the near future, CES might be one of major energy supply structures. The basic concept of CES is that it supplies electrical and thermal energy to the local customer loads through the islanded power network separated from the grid. Therefore, the interconnection with the grid occurs only when the energy supply from the CES generators does not meet the demand of the local load. For avoiding impacting the grid during the transition operation modes of CES, it is necessary to thoroughly analyse the influences on the grid during those periods. In order to show them, in this paper, we model the CES with 2.34 WVA DG and simulate the impacts on the grid due to interconnection of CES The simulation results show that, in order to reduce bad influences of CES on the grid, CES need the efficient load management and generation control schemes during the transition periods.

  • PDF

Preparation of Hydrated Basic Aluminum Salts by Homogeneous Precipitation Method and Their Thermal Decomposition (균일침전법에 의한 수화 염기성 알루미늄염의 합성 및 열분해)

  • 박홍채;김주석;이승호;오기동
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.1
    • /
    • pp.132-138
    • /
    • 1989
  • High purity(99.99%) spherical particles of hydrated Basic Aluminum Salts(BAS) were prepared by a homogeneous precipitation process utilizing the urea decomposition reaction and characterized by XRD, SEM, TG-DTA, IR and PSA methods. Amorphous hydrated BAS was precipitated in the range of pH 4~6. The molar ratio [Al3+]/[SO42-] for the precipitate particles was about 3.7. With increasing the concentration of aluminum sulfate the precipitation of the hydrated BAS occurred slowly and the precipitate particles with a narrow size distribution were fine(1-2${\mu}{\textrm}{m}$ in diameter). At temperatures in the range 400$^{\circ}$to 95$0^{\circ}C$, desulfurization and dehydroxylization resulted in weight loss with 22%. When the precipitate particles were thermally treated, the crystlline ${\gamma}$-Al2O3 was identifited by XRD at 50$0^{\circ}C$ and ${\gamma}$-Al2O3 particles were transformed into $\alpha$-Al2O3 at 100$0^{\circ}C$. A vermicular network was produced by calcining at 125$0^{\circ}C$ for 30min.

  • PDF

Development and Sensitivity Analysis of Life Estimation Program for Turbine Rotors (터빈로터 수명예측 프로그램의 개발 및 민감도 분석)

  • Park, Jae-Sil;Seok, Chang-Sung;Suh, Myung-Won;Hong, Kyung-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2654-2663
    • /
    • 2000
  • Steam turbine rotors are the most critical and highly stressed components of a steam power plant; therefore, the life expectancy of the turbine rotor is an important consideration for the safety of a steam power plant. The objective of this paper is to develop a life estimation program for turbine rotors for all possible operating conditions. For this purpose, finite element analysis was carried out for four normal operating modes (cold, warm, hot and very hot starts) using ABAQUS codes. The results are made into databases to evaluate the life expenditure for an actual operating condition. For any other possible abnormal operating condition, the operating data are transmitted to the server (workstation) through a network to carry out finite element analysis. Damage estimation is carried out by transmitting the finite element analysis results to the personal computer, and then the life expectancy is calculated.

A Study on Efficiency Enhancement in a Reciprocating Compressor for a Domestic Refrigerator (소형 냉장고용 왕복동식 압축기의 효율향상에 관한 연구)

  • Sim Yun-Hee;Youn Young;Park Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.418-426
    • /
    • 2005
  • Efficiency of the compressor is most important parameter in the domestic refrigerator which runs year around. With developed analytical model about heat transfer analysis in the hermetic compressor, parametric study was performed to know the effect on efficiency by design and material modification of the compressor. Volumetric efficiency of the compressor increased approximately $3\%$ when insulation is increased about $50\%$ in suction component. However, the insulation effect on discharge component was only $1\%$. When the thermal conductivity of the discharge plenum is reduced from 300 to 20 $W/m{\cdot}K$, volumetric efficiency increased about $3.1\%$. There is no attraction in efficiency increment with variation of outside surface area of the compressor and radial heat transfer coefficient of the solid component in the compressor shell.

A Study on Temperature Characteristics of KSTAR PFC and Vacuum Vessel at Baking Phase (KSTAR PFC와 진공용기의 가열탈리 단계에서의 온도특성에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Young-Jin;Jung, Nam-Yong;Kim, Kyung-Min;Lee, Je-Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.158-168
    • /
    • 2015
  • To create an ultra-high vacuum state at the KSTAR, the temperature of plasma facing component and vacuum vessel should be maintained at $300^{\circ}C$ and $110^{\circ}C$ respectively at a baking phase. The purpose of this research is obtaining the target baking temperatures. Experiments were performed to investigate the temperature characteristics of PFC and VV at the baking phase. Thermal network analysis was used to find heat transfer rates among PFC, VV and other components, and this analysis was verified by using the experimental data. The required heating energy of the PFC and the heating and cooling energy of the VV for the target baking temperatures were found to be 346 kW, 28 kW, and 136 kW, respectively.

Quench characteristics of YBCO thin films using magnetic field source for superconducting fault current limiters

  • Lee, B.W.;Park, K.B.;Kang, J.S.;Oh, I.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.11-14
    • /
    • 2004
  • YBCO thin films have good characteristics for current limiting materials due to compact size and high current carrying capability. But the irregularities and the extreme thin thickness of YBCO films cause some difficulties in simultaneous quench and thermal shock protection. In order to solve these problems, vertical magnetic field generated from solenoid coil was applied to the YBCO element. And also to minimize the inductance caused by the serial connection of magnetic field source with superconducting elements, magnetic field source was separated from the power lines adapting protective current transformer. In this study, electric field-current (E-I) and quench characteristics of YBCO films were analyzed both by electrical measuring method and observations of bubble propagation. From the experiment results, it was revealed that the magnetic fields generated by surrounding coil could induce the uniform quench distribution for all stripes of current limiting units and finally simultaneous quenches were realized in all serial connection of YBCO elements. In addition, the separation of magnetic field source form electrical network could be good solution for simultaneous quench of YBCO films without any unnecessary effect caused by serial connection.

A Basic Study of Thermal-Fluid Flow Analysis Using Grid Computing (그리드 컴퓨팅을 이용한 열유동 해석 기법에 관한 기초 연구)

  • Hong, Seung-Do;Ha, Yeong-Man;Cho, Kum-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.604-611
    • /
    • 2004
  • Simulation of three-dimensional turbulent flow with LES and DNS lakes much time and expense with currently available computing resources and requires big computing resources especially for high Reynolds number. The emerging alternative to provide the required computing power and working environment is the Grid computing technology. We developed the CFD code which carries out the parallel computing under the Grid environment. We constructed the Grid environment by connecting different PC-cluster systems located at two different institutes of Pusan National University in Busan and KISTI in Daejeon. The specification of PC-cluster located at two different institutes is not uniform. We run our parallelized computer code under the Grid environment and compared its performance with that obtained using the homogeneous computing environment. When we run our code under the Grid environment, the communication time between different computer nodes takes much larger time than the real computation time. Thus the Grid computing requires the highly fast network speed.

Surimi Quality from Mechanically Deboned Chicken Meat as Affected by Washing Cycle, Salt Concentration, Heating Temperature and Rate

  • Min, Byung-Jin;Lee, Sung-Ki
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.1
    • /
    • pp.131-136
    • /
    • 2004
  • The effects of salt concentration and heating conditions on the thermal gelation properties of surimi produced from mechanically deboned chicken meat (MDCM) were investigated. Chicken surimi was manufactured by washing (MDCM: 0.5% NaCl=1:4), standing, straining and centrifuging. The fat, water-soluble protein and heme pigment in the MDCM were removed by increasing washing cycles. The compressive force of the chicken surimi increased as the concentration of salt was increased from 0% to 5%. Total gel strength of the surimi measured by texture profile analysis showed a maximum in the range 3-5% NaCl. Microstructural analysis showed that the unfolding network structure of the surimi gel began to appear at NaCl concentrations>2%. The optimum heating condition for gelation was $90^{\circ}C$ for 40 min as this resulted in maximum values for measures of gel strength including compressive force, hardness, fracturability, adhesiveness, springiness, gumminess, chewiness and resilience. Chicken surimi gel formed by cooking at a heating rate of $1^{\circ}C/min$ to $90^{\circ}C$ showed better a texture than gels produced at $1.85^{\circ}C/min$. Our result show that a lower rate of heating improves chicken surimi gelation.