• Title/Summary/Keyword: Thermal Labyrinth

Search Result 6, Processing Time 0.026 seconds

Case Study on Application of Ground Heat Source in Thermal Labyrinth by CFD Model (CFD 모델을 이용한 열미로의 지중열원 활용에 관한 사례 연구)

  • Min, Joon-Ki;Nam, Sun-Young
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • In order to evaluate the performance of ground heat source in thermal labyrinth on pre-heating in winter season and pre-cooling in summer season, the followings are made as a conclusion through case study of H project by using the weather data from Korea meteorological administration and CFD model. By making outdoor air inlet via ground heat source in thermal labyrinth for conduction, convection and etc., the temperature rise is $13.4^{\circ}C$as the effect of pre-heating in winter season. On the other hand, as the effect of pre-cooling in summer season, the temperature decrease is $7.2^{\circ}C$. The energy saving rate by the application of ground heat source in thermal labyrinth is 9.1%.

Labyrinth Seal Design for Preventing Internal Inflow of Plating Solution (도금액의 내부 유입 방지를 위한 래버린스 시일 설계)

  • Lee, Duck-Gyu;Kim, Wan-Doo
    • Tribology and Lubricants
    • /
    • v.33 no.6
    • /
    • pp.256-262
    • /
    • 2017
  • Molten zinc plating is a process in which zinc is thinly coated over a metallic or non-metallic surface. It is used in various industrial fields for corrosion resistance and decoration. During the process, a steel sheet is passed through a roll that rotates inside the molten zinc liquid in the temperature range of $460^{\circ}C$ to $680^{\circ}C$, and the plating liquid flows into the roll causing abrasion and erosion of the roll surface. This problem is known to accelerate the replacement cycle of the roll and cause considerable economic loss owing to production line stoppage. Here, we propose a mechanism that operates at high temperature and pressure with a labyrinth type seal design to resolve this problem. We theoretically investigate the flow of the plating solution inside the seal and compute the minimum rotation speed required to prevent the plating solution from entering the seal chamber. In addition, we calculate the thermal deformation of the seal during operation and display thermally deformed dimensions at high temperatures. To verify the theoretical results, we perform experiments using pilot test equipment working in the actual plating environment. The experimental results are in good agreement with theoretical results. We expect our results to contribute towards the extension of the roll's life span and thereby reduce the economic losses.

Mechanical Isolation Method for an Air Intake Duct with Vertical Temperature Gradient (수직 온도구배를 갖는 공기 흡입 덕트의 기계적 격리기법)

  • Jung, Chihoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.87-93
    • /
    • 2016
  • In a Direct Connect(DC) mode altitude engine test, a labyrinth seal is set up between an air intake duct and an engine. The labyrinth seal plays a key role in mechanically isolating them, which contributes to the accurate measurement of thrust and the other component forces. However, when high vertical temperature gradient is generated in the supplied air in the duct, the isolation breaks down. In this paper, a labyrinth seal control device is designed and installed in an effort to eliminate the issue. Test result shows the device successfully gets rid of the contact problem even when high vertical temperature gradient is produced.

Characterising the dynamic seals used in absorber rod drive mechanisms in Indian FBR

  • Kaushal, Nihal;Patri, Sudheer;Kumar, R. Suresh;Meikandamurthy, C.;Sreedhar, B.K.;Murugan, S.;Raghupathy, S.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3438-3448
    • /
    • 2021
  • Dynamic seals are one of the critical components of Absorber Rod Drive Mechanism of Fast Breeder Reactors, requiring separate experimental development. Their significance can't be overemphasized considering that the availability and re-usability of Control Rod Drive Mechanisms of Fast Breeder Test Reactor is governed by the failure rate of dynamic seals (bellows). For prototype and subsequent Fast Breeder Reactors in India, choice of the dynamic seal is changed to an in-house designed & developed labyrinth type V-ring seal. The present work is related to the numerical investigations carried out to gain insights into the sealing mechanism and the thermal behaviour of these seals. The results indicate that the seal geometry is very important for obtaining optimum performance. By changing the geometry of the present seal, performance enhancement by more than 50% in important indices is obtained. Further, the results point out that caution shall be exercised when the seal material & its operating temperature are changed. Also, the numerical model developed in this study will be useful for developing more robust dynamic seals in future.

Investigation about the Decrease Efficiency of Thermal Discharge Temperature at Mixing Basin of Power Plant using 3-D CFD (3차원 수치모의에 의한 발전소 배수로 혼합지에서의 온배수 수온저감 효과에 대한 고찰)

  • Park, Byong-Jun;Lee, Sang-Hwa;Park, Ji-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.593-593
    • /
    • 2012
  • 본 연구는 화력 및 원자력 발전소로 취입된 냉각수(circulating and essential service water)가 복수기로부터 온배수 형태의 개수로 흐름으로 표층배수 될 경우 수온을 저감시키기 위해 주입하는 희석수(by-pass cooling water)와의 혼합효과의 효율성을 증대시키고, 불리한 수리현상을 야기하지 않으며, 경제적인 배수로 구조물을 고찰하기 위한 목적으로 시도되었다. 배수로 구조물 내 온배수와 희석수가 혼합되는 구간을 혼합지(mixing basin)라 하는데, 본 과업에서는 ${\bigcirc}{\bigcirc}$발전소의 배수로 구간 중 혼합지를 대상으로 FLOW-3D$^{(R)}$를 이용한 3차원 수치모형을 구축하고, 총 9개에 해당하는 각 대안별 현상을 분석하고 비교하였다. 각 대안들의 차이점은 배수로에 설치되는 보조구조물들의 형상과 배열 등이며, 복수기로부터 나오는 배출수의 수온은 $42^{\circ}C$, 희석수는 $35^{\circ}C$이고, 본 과업의 주요 관심대상 물리량은 유속과 온도이다. 배수로에 아무런 보조 구조물이 없는 형태인 기본 계획안을 검토한 결과, 평균 $3.31^{\circ}C$의 수온강하가 이루어졌으나, 우안 쪽으로 강한 흐름이 발생하여 수온의 좌우편차가 $4.61^{\circ}C$ 가량 발생하는 것으로 나타났다. 기본 계획안의 검토결과를 보완하기 위한 대안으로 연직 흐름의 소산을 위해 고안된 잠형 소파블록(baffle block) 설치안은 평균 $3.06^{\circ}C$의 수온강하가 이루어지고 $4.44^{\circ}C$의 수온 좌우편차가 발생했다. 지그재그(zigzag) 형태의 흐름을 만들어 혼합효과를 올리기 위한 미로형 수제(labyrinth groin) 설치안은 평균 $5.33^{\circ}C$의 수온강하가 이루어지고, $1.43^{\circ}C$의 수온 좌우편차를 보여줘 검토했던 대안들 중 가장 좋은 결과를 보여주었다. V자 배열 소파블럭(deformed block) 설치안은 연직 및 수평방향의 소산을 기대했으나 평균 $3.00^{\circ}C$의 수온 강하와 $4.41^{\circ}C$의 수온 좌우편차를 나타냈다. 벤츄리(Venturi) 형태의 흐름을 발생시키기 위한 병목형(bottleneck) 수로안은 평균 $3.18^{\circ}C$의 수온강하와 $3.94^{\circ}C$의 수온 좌우편차, 흐름의 소산과 흐름방향을 변화시키기 위한 와형 수제(swirl groin) 설치안은 평균 $2.24^{\circ}C$의 수온강하와 $1.48^{\circ}C$의 수온좌우편차, 우안 흐름을 지연시키기 위한 물방석(water cushion) 수로안은 평균 $3.03^{\circ}C$의 수온강하와 $4.50^{\circ}C$의 수온 좌우편차, 우안의 흐름을 좌안으로 보내기 위한 분사형(injector) 수로안은 평균 $3.13^{\circ}C$의 수온강하와 $4.45^{\circ}C$의 수온 좌우편차, 우안의 흐름을 막기 위한 외팔형 수제(cantilever groin) 설치안은 평균 $3.11^{\circ}C$의 수온강하와 $3.02^{\circ}C$의 수온 좌우편차가 발생하는 것으로 나타났다.

  • PDF