• 제목/요약/키워드: Thermal Input

검색결과 740건 처리시간 0.022초

증발부 내경 변화에 따른 진동형 히트파이프의 온도 거동에 관한 연구 (A Study on temperature behavior of pulsating heat pipe with different diameter in evaporator)

  • 김지훈;박철우;;김대중
    • 한국가시화정보학회지
    • /
    • 제17권1호
    • /
    • pp.10-18
    • /
    • 2019
  • In this study, the temperature behavior of Pulsating Heat Pipe (PHP) according to the diameter change were studied by limiting the diameter change to only the evaporator. To investigate operation of PHP in various heat input, heat input power was increased from 10 to 120 W. The results show operation can be divided into 3 regimes by temperature behavior. Thermal resistance was increased before start-up and decreased with increasing heat input. At 110 W heat input, thermal conductivity of 2 mm PHP was 8 .times higher compare to thermal conductivity of copper. Further, to investigate details of temperature behavior in higher heat input, FFT analysis was conducted. Based on the results, when the deviation of peak frequency in each section is lowest, the thermal resistance has lowest value.

Nonlinear Optimal Control of an Input-Constrained and Enclosed Thermal Processing System

  • Gwak, Kwan-Woong;Masada, Glenn Y.
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권2호
    • /
    • pp.160-170
    • /
    • 2008
  • Temperature control of an enclosed thermal system which has many applications including Rapid Thermal Processing (RTP) of semiconductor wafers showed an input-constraint violation for nonlinear controllers due to inherent strong coupling between the elements [1]. In this paper, a constrained nonlinear optimal control design is developed, which accommodates input constraints using the linear algebraic equivalence of the nonlinear controllers, for the temperature control of an enclosed thermal process. First, it will be shown that design of nonlinear controllers is equivalent to solving a set of linear algebraic equations-the linear algebraic equivalence of nonlinear controllers (LAENC). Then an input-constrained nonlinear optimal controller is designed based on that LAENC using the constrained linear least squares method. Through numerical simulations, it is demonstrated that the proposed controller achieves the equivalent performances to the classical nonlinear controllers with less total energy consumption. Moreover, it generates the practical control solution, in other words, control solutions do not violate the input-constraints.

용접 잔류응력 해석을 위한 Heat Input Model 개발 (Modeling of Welding Heat Input for Residual Stress Analysis)

  • 심용래;이성근
    • Journal of Welding and Joining
    • /
    • 제11권3호
    • /
    • pp.34-47
    • /
    • 1993
  • 용접에서 발생하는 열응력 및 잔류응력을 해석하기 위한 유한요소용 모델을 개발하였다. 여러 가 지 변수의 연구를 통하여 Ramp heat input function과 Lumped모델을 제시하였다. 용접부에 열입 력을 점차적으로 주기 위하여 Ramp heat input을 이용하였으며 Ramp input을 통하여 이차원 모 델에서의 이동열원의 영향을 고려하였고 실험치와 비교에서 최적 ramp시간을 결정하였다. 다층용 접에서는 용접 pass 에 비례하여 계산시간이 증가한다. 따라서 후판용접의 잔류응력계산에는 막 대한 계산시간이 필요하며 이를 줄이기 위하여 Lumped 모델을 개발하였다. 이 Lumped모델에서 는 각 용접층에 들어있는 용접 pass들을 하나의 lumped pass으로 이용하였으며 각 pass를 따로 계산한 모델 및 시험치와의 비교를 통하여 최적 lumped technique을 제시하였다. *****Finite element models were developed for thermal and residual stress analysis for the specific welding problems. They were used to evaluate the effectiveness of the various welding heat input models, such as ramp heat input function and lumped pass models. Through the parametric studies, thermal-mechanical modeling sensitivity to the ramp function and lumping techniques was determined by comparing the predicted results with experimental data. The kinetics for residual stress formation during welding can be developed by iteration of various proposed mechanisms in the parametric study. A ramp heat input function was developed to gradually apply the heat flux with variable amplitude to the model. This model was used to avoid numerical convergence problems due to an instantaneous increase in temperature near the fusion zone. Additionally, it enables the model to include the effect of a moving arc in a two-dimensional plane. The ramp function takes into account the variation in the out of plane energy flow in a 2-D model as the arc approaches, travels across, and departs from each plane under investigation. A lumped pass model was developed to reduce the computation cost in the analysis of multipass welds. Several weld passes were assumed as one lumped pass in this model. Recommendations were provided about ramp lumping techniques and the optimum number of weld passes that can be combined into a single thermal input.

  • PDF

산업 발생 노르말헥산과 벤젠 증기의 저온 분해 (Low-Temperature Thermal Decomposition of Industrial N-Hexane and Benzene Vapors)

  • 조완근;이준엽;강정환;신승호;권기동;김모근
    • 한국환경과학회지
    • /
    • 제15권7호
    • /
    • pp.635-642
    • /
    • 2006
  • Present study evaluated the low-temperature destruction of n-hexane and benzene using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst. The parameters tested for the evaluation of catalytic destruction efficiencies of the two volatile organic compounds(VOC) included input concentration, reaction time, reaction temperature, and surface area of catalyst. It was found that the input concentration affected the destruction efficiencies of n-hexane and benzene, but that this input-concentration effect depended upon VOC type. The destruction efficiencies increased as the reaction time increased, but they were similar between two reaction times for benzene(50 and 60 sec), thereby suggesting that high temperatures are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Similar to the effects of the input concentration on destruction efficiency of VOCs, the reaction temperature influenced the destruction efficiencies of n-hexane and benzene, but this temperature effect depended upon VOC type. As expected, the destruction efficiencies of n-hexane increased as the surface area of catalyst, but for benzene, the increase rate was not significant, thereby suggesting that similar to the effects of the re- action temperature on destruction efficiency of VOCs, high catalyst surface areas are not always proper for economical thermal destruction of VOCs. Depending upon the inlet concentrations and reaction temperatures, almost 100% of both n-hexane and benzene could be destructed, The current results also suggested that when applying the mesh type transition Metal Pt/SS catalyst for the better catalytic pyrolysis of VOC, VOC type should be considered, along with reaction temperature, surface area of catalyst, reaction time and input concentration.

응답계수(應答係數)를 이용(利用)한 건물벽에서의 열부하(熱負荷) 계산(計算) (Thermal Load Calculations on Stud-Frame Walls by Response Coefficient Method)

  • 황영규;박이동
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.357-368
    • /
    • 1988
  • An application of thermal response coefficient method for obtaining thermal load on stud-frame walls in a typical house is presented. A set of stud-frame walls is two-dimensional heat conduction transients with composite structure. The ambient temperature on the right-hand face of the stud-frame walls is a typical day-cycle input and the room temperature on the left-hand face is a constant input. The desired output is thermal load at the left-hand face. The time-dependent ambient temperature is approximated by a continuous, piecewise-linear function each having one hour interval. The conduction problem is spatially discretized as 8 computer modelings by finite elements to obtain thermal response coefficients. The discretization and round-off errors can be neglected in the range of adequate number of nodes. A 60-node discretization is recommended as the optimum model among 8 computer modelings. Several sets of response coefficients of the stud-frame walls are generated by which the rate of heat transfer through the walls or some temperature in the walls can be calculated for different input histories.

  • PDF

그라우팅 영역이 선형열원 해석에 미치는 영향에 관한 연구 (A Study of the Effect of Grouting Region on the Solution of Line Source Analysis)

  • 이세균;우정선;노정근
    • 에너지공학
    • /
    • 제19권3호
    • /
    • pp.143-150
    • /
    • 2010
  • 선형열원 해석은 열원 주위가 완전히 균일한 매질로 이루어져 있다는 가정 하에 성립되는 해석이나 실제 보어홀 시스템의 경우 그라우팅 영역은 주위토양과 매우 다른 열물성치를 가진 물질로 이루어져 있다. 본 연구에서는 이러한 그라우팅 영역이 선형열원 해석에 어떠한 영향을 미치는가를 연구하였다. 연구방법으로는 먼저 수치모델을 개발하고 이 수치모델에 의하여 시간에 따른 보어홀 유체온도를 생성한 후 이 유체온도를 선형열원법에 이용하여 지중열전도도와 보어홀 전열저항을 구하며 이렇게 구한 해를 수치모델의 입력조건과 비교함으로서 그 차이점을 규명한다. 이러한 해석결과 선형열원법의 해인 지중열전도도와 보어홀 전열 저항은 수치모델 입력조건에 비해 대략, 86%와 91%의 수준으로 나타났다. 선형열원 해로부터 수치모델의 입력조건을 역산해 나가는 Chart법이 본 연구에서 개발되었으며 시험용 보어홀의 열응답시험 결과와 비교해 본 결과 이 Chart법은 신뢰성이 있는 것으로 나타났다. 그라우트 영역의 열물성치를 변화시켜가며 선형열원해의 특성이 어떻게 변하는지도 검토하였다.

유입공기의 온도변화가 전자모듈의 냉각에 미치는 영향 (Cooling effect of an electronic module with a variation of the inlet air temperature)

  • 이진호;조성훈
    • 한국군사과학기술학회지
    • /
    • 제4권1호
    • /
    • pp.264-273
    • /
    • 2001
  • The conjugate heat transfer from a protruding module in a horizontal channel with a variation of air temperature is experimentally investigated. It is an aim of this study is to estimate temperature difference between a module and air. This study is performed with a variation of parameters that are air temperatures($T_i,=25^{\circ}C{\sim}55^{\circ}C),$ thermal resistance($R_c=158 K/W),$ air velocities ( 4V_i=0.1$ m/s~l.5 m/s ), and input power (Q=3 W, 7 W ). The results show that as the thermal resistance increases, the effect of air temperatures are decreased. And input power was most effective parameter on the temperature difference between a module and air.

  • PDF

냉매압축기 성능시험장치의 제어 특성 (Control characteristics of a refrigerant compressor test facility)

  • 이진영;이대영;김광호;남평우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.46-51
    • /
    • 1999
  • This paper describes the control charcteristics of thermal/flow systems. In thermal/flow systems, the transport lag plays as a dead time causing a deterioration of the controllability. Besides this, such many parameters including the temperature, pressure, and flow rate affect the system response that a control scheme which can deal with multi-input is required. Particularly in a refrigerant compressor test facility, the evaporator and condenser interact each other so that the change in the evaporator pressure cause the condenser pressure to change or vice versa. Therefore, to control the evaporator pressure, not only the cooling water flow rate in the evaporator but also the coolant flow rate in the condenser is considered. Meanwhile, the conventional PID controllers, which is suitable for a single input system, shows a large overshoot for a disturbance input. In this work, the predictive control scheme is introduced and its applicability is discussed for thermal/flow systems.

  • PDF

공기온도가 열전도성 기판 위에 탑재된 군용 전자칩 냉각에 미치는 영향 (The effect of inlet air temperature for the cooling of the military electronic chip on the thermal conductive board)

  • 이진호
    • 한국군사과학기술학회지
    • /
    • 제5권2호
    • /
    • pp.195-206
    • /
    • 2002
  • The conjugate heat transfer from the simulated module in a horizontal channel with the variation of inlet air temperature is experimentally investigated. The aim of this study is to estimate temperature difference between a module and inlet air. This study is performed with the variation of parameters that are inlet air temperature(Ti=25~$55^{\circ}C), thermal resistance( $R_c$=0.05, 4.11, 158 K/W), inlet air velocity(Vi=0.1~1.5m/s), and input power(Q=3, 7 W). The results show that the effect of inlet air temperature is little, at the case of using conductive board. And input power was most effective parameter on the temperature difference between module and Inlet air.

열상장비의 포화 현상에 대한 시스템 모델링 (System-Level Saturation Modeling of Thermal Imager)

  • 한승오;박승만
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.698-702
    • /
    • 2016
  • Thermal imager is now regarded as one of the key observation devices for ISR activities and getting important more and more. As other detectors, however, the thermal detectors also have maximum input and therefore they will be saturated if the input IR energy exceeds the allowed range. The saturation in the thermal detector makes it impossible to distinguish the target from background, as a result, the thermal imager does not perform its own mission anymore. In order to get an insight related with the image saturation, this paper develops a saturation model for a thermal imaging system, not a thermal detector. The proposed modeling starts from analyzing the specification of a thermal imager. Coupled with the characteristic parameters of the object, the saturation model can be used to predict the distance on which the detector is saturated. The proposed saturation model prove its validity by applying it for the case of observing a flash-bang.