• 제목/요약/키워드: Thermal Imager System

검색결과 22건 처리시간 0.02초

열상장비의 포화 현상에 대한 시스템 모델링 (System-Level Saturation Modeling of Thermal Imager)

  • 한승오;박승만
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.698-702
    • /
    • 2016
  • Thermal imager is now regarded as one of the key observation devices for ISR activities and getting important more and more. As other detectors, however, the thermal detectors also have maximum input and therefore they will be saturated if the input IR energy exceeds the allowed range. The saturation in the thermal detector makes it impossible to distinguish the target from background, as a result, the thermal imager does not perform its own mission anymore. In order to get an insight related with the image saturation, this paper develops a saturation model for a thermal imaging system, not a thermal detector. The proposed modeling starts from analyzing the specification of a thermal imager. Coupled with the characteristic parameters of the object, the saturation model can be used to predict the distance on which the detector is saturated. The proposed saturation model prove its validity by applying it for the case of observing a flash-bang.

320x240 적외선 배열검출기를 이용한 고분해능 열상 신호처리기 구현 (High Resolution Electronic Processor Design for Thermal Imager with 320x240 Staring Array Infrared Detector)

  • 홍석민;유위경;윤은숙
    • 한국군사과학기술학회지
    • /
    • 제9권2호
    • /
    • pp.111-117
    • /
    • 2006
  • This paper describes the design principles and methods of electronic processor for thermal imager with 320$\times$240 staring array infrared detector. For the detector's nonuniformity correction and excellent image quality, we have designed the multi-point correction method using the defocusing technique of the optics. And to enhance the image of low contrast and improve the detection capability, the new technique of histogram processing has been designed. Through these image processing techniques, we have developed the high quality thermal imager and acquired a satisfactory thermal image. The result of MRTD(Minimum Resolvable Temperature Difference) is $0.1^{\circ}C$ at 4cycles/mard.

시험용 달 궤도선의 광학탑재체 시스템 열설계에 대한 수치해석적 연구 (Numerical Study on the Thermal Design of Lunar Terrain Imager System Loaded on the Korea Pathfinder Lunar Orbiter)

  • 김택영;장수영;허행팔
    • 한국항공우주학회지
    • /
    • 제47권4호
    • /
    • pp.309-318
    • /
    • 2019
  • 한국형 달 궤도선(Korea Pathfinder Lunar Orbiter, KPLO)에 탑재되는 달 표면지형 광학관측기(Lunar Terrian Imager, LUTI)의 열설계를 수행하고, 열해석을 통하여 열설계의 건전성을 검증하였다. 달 임무궤도의 열환경은 지구궤도와 달리 달 표면의 IR 복사가 중요하므로 이를 열설계에 반영하여야 한다. 위성 외부에 노출되는 부품이나 모듈은 가능한 MLI로 단열시키지만 경통이나 방열판은 기능상 노출되므로 복사형상계수의 개념을 이용한 thermal shield를 전면에 장착함으로써 IR 복사를 완화시킨다. 태양복사를 거의 받지 않는 방열판의 전면부는 IR 방사율이 중요하며, 경통과 같이 열변형에 취약한 부품은 복사히터를 사용하여 온도구배를 최소화시킨다. 열해석 결과분석을 통하여 LUTI의 열설계는 다양한 상황에서 안정적임을 확인하였다.

정지궤도위성의 해양관측센서 임무 궤도 열해석 (ON-ORBIT THERMAL ANALYSIS FOR THE GEOSTATIONARY OCEAN COLOR IMAGER OF A GEOSTATIONARY SATELLITE)

  • 김정훈;전형열
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.135-141
    • /
    • 2009
  • A preliminary thermal analysis is performed for the optical payload system of a geostationary satellite. The optical payload considered in this paper is GOCI(Geostationary Ocean Color Imager) of COMS of Korea. The radiative and conductive thermal models are employed in order to predict thermal responses of the GOCI on the geostationary orbit. According to the results of this analysis are as follows: 1) the GOCI instrument thermal control is satisfactory to provide the temperatures for the GOCI performances, 2) the thermal control is defined and interfaces are validated, and 3) the entrance baffle temperature is found slightly out its specification, therefore further detailed analyses should be continued on this element.

  • PDF

통신해양기상위성 해양탑재체 정지궤도 예비 열해석 (PRELIMINARY ON-ORBIT THERMAL ANALYSIS FOR THE GEOSTATIONARY OCEAN COLOR IMAGER OF COMS)

  • 김정훈;전형열;한조영
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.24-30
    • /
    • 2010
  • A preliminary thermal analysis is performed for the optical payload system of a geostationary satellite. The optical payload considered in this paper is GOCI(Geostationary Ocean Color Imager) of COMS of Korea. The radiative and conductive thermal models are employed in order to predict thermal responses of the GOCI on the geostationary orbit. The results of this analysis are as follows: 1) the GOCI instrument thermal control is satisfactory to provide the temperatures for the GOCI performances, 2) the thermal control is defined and interfaces are validated, and 3) the entrance baffle temperature and shutter wheel motor gradient are found slightly out their specification, therefore further detailed analyses should be continued on these elements.

정지궤도위성 광학탑재체 복사 열제어 시스템 개념 설계 (A CONCEPTUAL DESIGN OF RADIATIVE THERMAL CONTROL SYSTEM IN A GEOSTATIONARY SATELLITE OPTICAL PAYLOAD)

  • 김정훈;전형열
    • 한국전산유체공학회지
    • /
    • 제12권3호
    • /
    • pp.62-68
    • /
    • 2007
  • A conceptual thermal design is performed for the optical payload system of a geostationary satellite. The optical payload considered in this paper is GOCI(Geostationary Ocean Color Imager) of COMS of Korea. The radiative thermal control system is employed in order to expect a small thermal gradient in the telescope structure of GOCl. Two design margins are applied to the dedicated radiator dimensioning, and three kinds of configuration to the heater power sizing. A Monte-Carlo ray tracing method and a network analysis method are utilized to calculate radiative couplings and thermal responses respectively. At the level of conceptual design, sizing thresholds are presented for the radiator and heater on the purpose of determining the mass and power budget of the spacecraft.

적외선 센서를 이용한 열상장비의 구현 (Thermal Imager Implementation Using Infrared Sensor)

  • 유위경;윤은숙;김창우;송인섭;홍석민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1250-1254
    • /
    • 1992
  • This paper describes the designed and fabricated thermal imaging system with the SPRITE(Signal PRocessing in The Element) detector, operating in the 3-12 micron band. This system consists of an afocal telescope, a scan unit containing the SPRITE detector, an electronic processor unit and a cooler. The optical scan system utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using five elements of the detector. And the electronic processor unit performs digital scan conversion to reform the parallel data stream into serial analog data compatable with conventional RS-170 video. The scan field of view is 40 ${\times}$ 26.7 and the MRTD(Minium Resolvable Temperature Difference) is 0.6 K at 7.5 cycles/mm. The acquired thermal image indicates that this system has a satisfactory performance.

  • PDF

바이메탈형 적외선 이미지 센서 제작과 칸틸레버 변위에 관한 고찰 (A study on MicroCantilever Deflection for the Infrared Image Sensor using Bimetal Structure)

  • 강정호
    • 한국기계가공학회지
    • /
    • 제4권4호
    • /
    • pp.34-38
    • /
    • 2005
  • This is a widespread requirement for low cost lightweight thermal imaging sensors for both military and civilian applications. Today, a large number of uncooled infrared detector developments are under progress due to the availability of silicon technology that enables realization of low cost IR sensor. System prices are continuing to drop, and swelling production volume will soon drive process substantially lower. The feasibility of micromechanical optical and infrared (IR) detection using microcantilevers is demonstrated. Microcantilevers provide a simple Structurefor developing single- and multi-element sensors for visible and infrared radiation that are smaller, more sensitive and lower in cost than quantum or thermal detectors. Microcantilevers coated with a heat absorbing layer undergo bending due to the differential stress originating from the bimetallic effect. This paper reports a micromachined silicon uncooled thermal imager intended for applications in automated process control. This paper presents the design, fabrication, and the behavior of cantilever for thermomechanical sensing.

  • PDF

비냉각 열상시스템에서 TEC-Less를 이용한 절대온도 측정 정밀도 향상 기법 (Novel Accuracy Enhancement Method for Absolute Temperature Measurement Using TEC-LESS Control in Uncooled Thermal Imaging)

  • 한준환
    • 한국컴퓨터정보학회논문지
    • /
    • 제17권12호
    • /
    • pp.41-47
    • /
    • 2012
  • 모든 물체는 절대온도 0도 이상에서 복사에너지를 방출한다. 비냉각 열상시스템은 입사된 복사에너지를 검출하여 신호처리를 통해 영상으로 출력하는 장비이다. 최근에는 비냉각 열상장비를 활용하여 의료, 산업, 및 군수 등의 다양한 분야에 응용 되고 있으며, 다양한 응용분야에 대한 많은 연구가 진행되고 있다. 본 논문에서는 비냉각 열상시스템 검출기 내부에 열전소자가 없는 검출기를 보다 효과적으로 제어하여 영상의 화질을 향상시키고 이를 기반으로 온도 측정 정밀도를 극대화 할 수있는 효율적인 제어기법에 대해 설명한다. 제안하는 기법은 비냉각 열상시스템에 TEC-less 및 온도 검출 알고리듬을 적용하는 것이다. 실제 챔버를 활용하여 시험을 수행한 결과 알고리듬 적용 전 시스템보다 우수한 화질의 영상을 획득하고 온도 측정 정밀도가 $1^{\circ}C$이하로 향상됨을 확인할 수 있었다.

비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교 (Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application)

  • 김병혁;정한;김영호
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.