• Title/Summary/Keyword: Thermal Exposure

Search Result 519, Processing Time 0.026 seconds

Utilization of Immersion-Drying Method for Measuring Damage Depth of Fire-Damaged High-Strength Concrete (화재로 손상된 고강도 콘크리트의 손상 깊이 측정을 위한 수중침지 건조방법의 활용)

  • Kim, Jong;Lim Gun-Su;Beak, Seung-Bok;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.297-308
    • /
    • 2024
  • This study presents a novel approach for evaluating fire-induced damage depth in concrete. The methodology leverages the principle that exposure to high temperatures causes internal expansion within concrete, leading to increased voids and microcracks in the damaged zones. This heightened porosity results in greater absorption rates compared to undamaged areas. By immersing fire-damaged concrete samples in water and subsequently monitoring the drying process, the depth of damage can be assessed. Differences in drying rates and color variations between damaged and undamaged areas serve as visual indicators for determining the extent of the damage. Experimental results from this water immersion method revealed damage depths of 38.7mm and 37.5mm for two different concrete mixtures. These measurements notably surpass the damage depths estimated using traditional phenolphthalein-based methods. This discrepancy suggests that utilizing the absorption rate principle, which is directly linked to the physical changes caused by thermal expansion, offers a more accurate and sensitive assessment of fire damage depth compared to methods relying solely on the presence of Portlandite for colorimetric indication.

Human Health Risk, Environmental and Economic Assessment Based on Multimedia Fugacity Model for Determination of Best Available Technology (BAT) for VOC Reduction in Industrial Complex (산업단지 VOC 저감 최적가용기법(BAT) 선정을 위한 다매체 거동모델 기반 인체위해성·환경성·경제성 평가)

  • Kim, Yelin;Rhee, Gahee;Heo, Sungku;Nam, Kijeon;Li, Qian;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.325-345
    • /
    • 2020
  • Determination of Best available technology (BAT) was suggested to reduce volatile organic compounds (VOCs) in a petrochemical industrial complex, by conducting human health risk, environmental, and economic assessment based on multimedia fugacity model. Fate and distribution of benzene, toluene, ethylbenzene, and xylene (BTEX) was predicted by the multimedia fugacity model, which represent VOCs emitted from the industrial complex in U-city. Media-integrated human health risk assessment and sensitivity analysis were conducted to predict the human health risk of BTEX and identify the critical variable which has adverse effects on human health. Besides, the environmental and economic assessment was conducted to determine the BAT for VOCs reduction. It is concluded that BTEX highly remained in soil media (60%, 61%, 64% and 63%), and xylene has remained as the highest proportion of BTEX in each environment media. From the candidates of BAT, the absorption was excluded due to its high human health risk. Moreover, it is identified that the half-life and exposure coefficient of each exposure route are highly correlated with human health risk by sensitivity analysis. In last, considering environmental and economic assessment, the regenerative thermal oxidation, the regenerative catalytic oxidation, the bio-filtration, the UV oxidation, and the activated carbon adsorption were determined as BAT for reducing VOCs in the petrochemical industrial complex. The suggested BAT determination methodology based on the media-integrated approach can contribute to the application of BAT into the workplace to efficiently manage the discharge facilities and operate an integrated environmental management system.

Serum Enzyme and Isozyme Activities of Rats Acclimated to Cold Environment (寒冷環境에 순화시킨 흰쥐의 血淸酵素 및 同位酵素의 活性)

  • 정애순;남상열
    • The Korean Journal of Zoology
    • /
    • v.29 no.2
    • /
    • pp.107-120
    • /
    • 1986
  • The activities of serum of serum lactate dehydrogenase (SLDH), serum alkaline phosphatase (SALP), serum creatine phosphokinase (SCPK), and their isozymes were determined in adult male Sprague-Dawley rats acclimated to cold environment $(4\\pm1^\\circC)$ for 36 days. The SLDH activity was significantly higher in the early stage of acclimated period. The steady state of SLDH activity seemed to be reached by the end of acclimated period. Electrophoretic separation of serum of control rat showed three SLDH isozymes. Isozymes SLDH4 and SLDH5 appeared most prominently, whereas only trace of SLDH1 or SLDH2 was found. The increase in SLDH level during acclimation to cold environment is a reflection of an immediate increase in the SLDH1, SLDH2, and SLDH3 type of SLDH isozyme. The acclimation to cold environment increased significantly level of SALP in the early state of acclimated period. SALP activity showed a attaining steady state with the resting level after transient rise. Electrophoretic separation of SALP of control rats showed the SALP1 and SALP2 fractions. The transient rise in SALP activity of rats acclimated to cold environment coincided with a transient rise in SALP1 fraction. Immediately after exposure to cold environment, there was significant elevation in SCPK activity. Value returned to normal after transient rise. A new steady state of SCPK activity seemed to be reached by 36 days. It may be inferred from the above data that thermal compensation appears to result from a change in the activity of an enzyme and that the SLDH, SLDH-isozyme, SALP-isozyme, and SCPK may be involved directly or indirectly in thermoregulation during acclimation to cold environment.

  • PDF

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

Accelerated Degradation Test and Failure Analysis of Rapid Curing Epoxy Resin for Restoration of Cultural Heritage (문화재 복원용 속(速)경화형 Epoxy계 수지의 가속열화시험 및 고장분석 연구)

  • Nam, Byeong Jik;Jang, Sung Yoon
    • Journal of Conservation Science
    • /
    • v.33 no.6
    • /
    • pp.467-483
    • /
    • 2017
  • In this study, the degradation properties by temperature stress of $Araldite^{(R)}$ rapid-curing epoxy resin used for inorganic cultural heritages, was identified. The tensile and tensile shear strength of durability decreased for 12,624 hours at temperatures of $40{\sim}60^{\circ}C$. In terms of stability of external stress and temperature, the slow-curing epoxy was superior to the rapid-curing epoxy, and cultural heritage conservation plans should therefore consider the strength and stress properties of restoration materials. Color differences increased for 12,624 hours at temperatures of $40{\sim}60^{\circ}C$, and glossiness decreased. Both color and gloss stability were weak, which necessitates the improvement of optical properties. Thermal properties (weight loss, decomposition temperature, and glass transition temperature) of adhesives are linked to mechanical properties. Interfacial properties of the adherend and water vapor transmission rates of adhesives are linked to performance variation. For porous media (ceramics, brick, and stone), isothermal and isohumid environments are important. For outdoor artifacts on display in museums, changes in physical properties by exposure to varying environmental conditions need to be minimized. These results can be used as baseline data in the study of the degradation velocity and lifetime prediction of rapid-curing epoxy resin for the restoration of cultural heritages.

The Feasibility of Natural Ventilation in Radioactive Waste Repository Using Rock Cavern Disposal Method (동굴처분 방식을 사용하는 방사성 폐기물 처분장의 자연 환기 타당성 평가)

  • Kim Jin;Kwon Sang Ki
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.183-192
    • /
    • 2005
  • Natural ventilation in radioactive waste repositories is considered to be less efficient than mechanically forced ventilation for the repository working environment and hygiene & safety of the public at large, for example, controlling the exposure of airborne radioactive particulate matter. It is, however, considered to play an important role and may be fairly efficient for maintaining environmental conditions of the repository over the duration of its lifetime, for example, moisture content and radon (Rn) gas elimination in repository. This paper describes the feasibility of using natural ventilation which can be generated in the repository itself, depending on the conditions of the natural environment during the periods of repository construction and operation. Evidences from natural cave analogues, actual measurements of natural ventilation pressures in mountain traffic tunnels with vertical shafts, and calculations of airflow rates with given natural ventilation pressures indicate possible benefits from passive ventilation for the prospective Korean radioactive waste repository. Natural ventilation may provide engineers with a cost-efficient method for heat and moisture transfer, and radon (Rn) gas elimination in a radioactive waste repository. The overall thermal performance of the repository may be improved. The dry-out period may be extended, and the seepage flux likely would be decreased.

  • PDF

Artificial Spawning, Larval and Spat Developments of the Bay Scallop, Argopecten irradians (해만가리비, Argopecten irradians의 인공산란과 유생 및 치패의 발생)

  • Oh, Bong-Se;Jung, Choon-Goo;Kim, Sook-Yang
    • The Korean Journal of Malacology
    • /
    • v.19 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Artificial spawning, larval and spat developments of the bay scallop, Argopecten irradians, which was transplanted from China on 16 August 1996, were investigated monthly until August 1997 in the Deukyang Bay, Jangheung-gun, Jeollanam-do, Korea. Sufficient amount of cultured microalgae supplemented seawater were supplied as food (6 kinds of phytoplankton) for fully grown adult individuals at 17.1-23.2$^{\circ}C$ for 44 days. A total of 45,320,000 eggs were spawned by way of 2 times of artificial spawning inductions such as exposure stimulus to the air and thermal shock (with water temperature) on 29 January and 31 January in 1997. Artificially fertilized eggs were developed to D-shaped larvae (77.5 ${\times}\;63.8\;{\mu}m)$ and metamorphosed to larvae (191.8 ${\times}\;181.2\;{\mu}m)$ 181.2 m) in the attached larval stage on the collectors. A total of 110,000 spats (average 3.04 mm in shell length) were produced at 22.8-26.3$^{\circ}C$ and 31.0-34.4 psu in the indoor rearing tank from 14 February through 7 May in 1997. In case of Argopecten irradians, if the attached larvae in the attachment stage are detached from the collector, they could not live. Accordingly, it is assumed that survival (%) of the attached larvae of A. irridians showed very low because of weak power attached to the collector due to the small number of the byssuses of the attached larva, not the short attachment period by the byssus as seen in other scallops such as Argopecten balloti.

  • PDF

Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns without Loading (섬유혼입공법을 적용한 고강도콘크리트 기둥의 비재하 내화시험)

  • Youm, Kwang-Soo;Jeon, Hun-Kyu;Kim, Heung-Youl
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.465-471
    • /
    • 2009
  • To prevent the explosive spalling of the high strength concrete and control the rise of temperature in the steel rebar during fire, a fiber cocktail method has been proposed simultaneously with the use of polypropylene and steel fiber. After applying the fiber cocktail (polypropylene and steel fibers) into the mixture of high strength concrete with a compressive strength of between 40 and 100 MPa and evaluating the thermal properties at elevated temperatures, the fire test was carried out on structural members in order to evaluate the fire resistance performance. Two column specimens were exposed to the fire without loading for 180 minutes based on the standard curve of ISO-834. No explosive spalling has been observed and the original color of specimen surface was changed to light pinkish grey. The inner temperature of concrete dropped rapidly starting from 60mm deep. After 60 minutes of exposure to the fire, the temperature gradient of fiber cocktail reinforced high strength concrete was measured as 2.2oC/mm, which is approximately 5 times less than that of normal concrete. The final temperatures of steel rebar after 180 minutes of fire test resulted in 488.0oC for corner rebar, 350.9oC for center rebar, and 419.5oC for total mean of steel rebar. The difference of mean temperature between corner and center rebar was 137.1oC The tendency of temperature rise in concrete and steel rebar changed between 100oC and 150oC The cause of decrease in temperature rise was due to the water vaporization in concrete, the lower temperature gradient of the concrete with steel and polypropylene fiber cocktails, the moisture movement toward steel rebars and the moisture clogging.

Developing improvement technology in pre-etching process for the Shadow Mask quality of flat color TV

  • Park, Jong-Moo;Park, Kwang-Ho;Jung, Hyo-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1164-1167
    • /
    • 2003
  • Recently CRT is getting flatted, As change of CRT trend from normal type to Flat type, the material of Shadow Mask was also changed from AK(Aluminum Killed) to Invar(Fe-Ni alloy) materials Until now we have used just AK(Aluminum Killed) for normal type TV(not flat type), but main raw material of shadow mask component was changed. . However recently Invar(Fe-Ni alloy) materials, which has advantage of Low Thermal Expansion and High Strength, has been developed as well as applying in mass production as CRT's trend has become more flat and fine pitch. As main raw material of shadow mask component was changed, conditions of process were changed. One of them, the importance of pre-etching process (assistant process for developing & etching) is improved because there are so many particles in the pre-etching bath because of Ni compounds. Since the solubility of Ni in pre-etching solvent is very low related to Fe's, so the compounds of Ni happen to make particles.(the solubility of Fe is twenty times Ni's) that particles happen to make process troubles and NG productions so to clear the particles we had to established high cost filtering system, but it is useless. As time goes by the quantity of particles (Ni compounds) was increased because of the capability of filtering system was not enough, the particles was produced continuous in bath, and it make quality problems. Hence we tried to develop the new pre-etching solution to remove the particles (Ni compounds) and to cost down the filtering system's running cost. But in improving the solution we discovered the new pre-etching solution made the PR developing better. In former solution there were three kinds of chemistry (COOH)2 , H2O2 , H2S04 .first the function of (COOH)2 is drilling the surface of Invar, during this mechanism Ni compounds occurred. Second the function of H202 is removing the PR fringe (half UV exposure zone on PR(PVA)), Third the function of H2S04 is the catalysis of (COOH)2 In those, (COOH)2 was the main reason to make the Ni compounds. So to improve the solutions we had to change (COOH)2 to the other material. the chemistry we improved was a complex chemistry based on H2S04 . after using this chemistry the particles problem was disappeared and there was another advantage cut down the PR fringe. The New solution made the function of H202 better so the PR developing improved. To be direct the catalyst of the new solution helped the H202. anyway First thing after change the solution the quality of shadow Mask for flat color TV was improved & the yield also improved. But the more important thing is how to control the new solution. So we accepted the new concept which was the degree of freshness. The degree of freshness is based on non-reacted solution which was 100% ( the degree of freshness) and calculated the melted Ni quantity as time goes by. So we made the gauging liner plot. In conclusion, many companies tried to make fine pitched Shadow Mask ,generally to make quality jump up it needed a lot of cost & persons .in this case the shift of core material made it possible.

  • PDF

Plasma Potential of Atmospheric Plasma Double Jets (대기압 플라즈마 이중 제트의 플라즈마 전위)

  • Kang, Han-Lim;Kim, Jung-Hyun;Kim, Hyun-Chul;Han, Sang-Ho;Cho, Gunagsup
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.312-321
    • /
    • 2012
  • The electric potential of plasma column is measured with the high voltage probe in a pair of atmospheric plasma jets operated by AC-voltage. According to the polarity of voltage applied to the electrodes, the polarity of plasma column potential has the same polarity of applied voltage. The high potential of plasma column at the side of high voltage electrode is decreased linearly along the plasma column to the ground side. Therefore, the plasma column seams to be a kind of resistor whose resistivity is a few 10s $M{\Omega}/m$. In the experiment of double-jets system, the polarity of plasma potential is verified to be the same polarity to the applied voltage. When the different voltage polarities are applied to the electrodes of double plasma jets, the attractive force is acted between two plumes at the merged plasma and the plasma potential is measured to be low as a few 10s V. When the same polarity of voltage is applied to the electrode, the repulsive force is acted and the plasma potential is measured to be high as a several 100s V at the merged plumes. In the exposure of plasma plume on the bio-substrate with the double plasma jets, the electric shock and thermal damage might be proportional to the plasma power which is the multiplication of the plasma potential and the plasma current.