Examining Diurnal Thermal Variations by Urban Built Environment Type with ECOSTRESS Land Surface Temperature Data: Evidence from Seoul, Korea (도시 건조환경 유형에 따른 서울시 주간 지표면 온도 변동성 분석: ECOSTRESS 데이터의 활용)

  • Gyuwon Jeon;Yujin Park
    • Journal of the Korean Regional Science Association
    • /
    • v.40 no.2
    • /
    • pp.107-130
    • /
    • 2024
  • Urban land surface temperature (LST) change is a major environmental factor that affects the thermal comfort, energy consumption, and health of urban residents. Most studies that explored the relationship between LST and urban built-environment form analyzed only midday LST. This study explores the diurnal variation of summertime LST in Seoul using ECOSTRESS data, which observes LST at various times of the day and analyzes whether the LST variation differs by built environment type. Launched in 2018, ECOSTRESS operates in a non-sun-synchronous orbit, observing LST with a high resolution of 70 meters. This study collected data from early morning (6:25) to evening (17:26) from 2019 to 2022 to build time-series LST. Based on greenery, water bodies, and building form data, eight types of Seoul's built environment were derived by hierarchical clustering, and the LST fluctuation characteristics of each cluster were compared. The results showed that the spatial disparity in LST increased after dawn, peaked at noon, and decreased again, highlighting areas with rapid versus stable LST changes. Low-rise and high-rise compact districts experienced fast, high temperature increases and high variability, while low-density apartments experienced moderate LST increases and low variability. These results suggest urban forms that can mitigate rapid daytime heating.

Effects of Regular Jjimjilbang(Korean sauna) Exposure on Human Heat Tolerance in Young and Old Females (정기적인 찜질 훈련이 청년과 노년여성의 내열성 증진에 미치는 영향)

  • Choi, Jeong-Wha;Song, Eun-Young;Hwang, Soo-Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.9_10
    • /
    • pp.1465-1474
    • /
    • 2007
  • We analyzed the effects of regular Jjimjilbang(Korean sauna) exposure on the heat tolerance in young and old females. Subjects were young(n=7) and old(n=7) females who never had a bath in Jjimjilbang for last year. Jjimjilbang training group took a bath in Jjimjilbang once a week 19 times. Jjimjibang expsure was limited three times per day, Jjimjil were taken free way. To prove the effects of the heat tolerance, Subjects were exposed to hot and humid air$(40.0{\pm}0.5^{\circ}C,\;60{\pm}5%RH)$. In the condition, subjects were taken a foot bathing$(40.0{\pm}0.5^{\circ}C)$ and simulated for 30 min., and rectal temperature, skin temperatures, clothing microclimate, blood pressure, total body weight loss, local sweat and subjective sensation were measured. The results are as follow: Rectal temperature, skin temperatures, clothing microclimate, total body weight and subjective thermal comfort sensation were decreased gradually(p<.001). Local sweat of upper arm was decreased(p<.01). In conclusion. the regular Jjimjilbang exposure has positive effects upon improvement in regulation of body temperature, especially in heat tolerance.

The Individual Heat-recovery ventilation system of Residential Buildings (주거용 건물의 개별 환기시스템 필요성에 관한 연구)

  • Shin, U-Cheul;Lee, Wang-Je;Yoon, Jong-Ho;Baek, Nam-Choon
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

Using and Evaluative Criteria for Purchasing of Sleepwear in Winter (겨울철 잠옷이용실태와 구매시 평가기준)

  • Kweon, Soo-Ae;Choi, Jong-Myoung;Kim, Eun-Young
    • Korean Journal of Human Ecology
    • /
    • v.10 no.1
    • /
    • pp.101-111
    • /
    • 2001
  • The purpose of this study was to investigate using and evaluative criteria for purchasing of sleepwear in winter. Subjects were 523 males and females aged from twenties to fifties, living in Chongju and Taejon. For data analysis, frequency, descriptive analysis, t-test, and F-test were used. The results are as follows. First, the ownership of sleepwear was sweat suits with zippered top, pajamas, T-shirts/pants, underwear, and nightgown in order. The mean of using sweat suits was used the highest, and subjects used more home wear than sleepwear in winter. Second, the using or sleepwear had a significant difference in cold-sensitiveness and body types. Cold-sensitive group used sweat suit and T-shirts/pants more than cold-insensitive group. Also, groups who are thin wore sweat suit the most while groups who are corpulent, used underwear the most when they slept. Third, subjects, who are married women and use bed, used nightgown, but pajamas were used by groups who are older, married, and professional. Sweat suits and T-shirts/pants were used the most by single aged twenties. Forth, consumers considered the wearing comfort when they purchased sleepwear for winter, and they evaluated washing/management, fabric, design/style, economic, service, brand, and others' response in order, for judging the quality of sleepwear. Also, the evaluative criteria had a significant difference in demographic variables such as sex, occupation, and marital state. These results implied that sleepwear would be needed for winter in terms of behavioral temperature regulation. Especially, cold-sensitive and thin group would wear knitted and two-piece sleepwear for thermal comfort when they sleep in winter. Also, Using and evaluative criteria of sleepwear would be different in demographic characteristics. For winter, sleepwear should be develop based on physiologic as well as demographic variables.

  • PDF

A Study on the Analysis and Verification of Evaluation system for the Usability Evaluation of Purpose-Based XR Devices (목적 기반 XR 디바이스의 사용성 평가를 위한 평가체계 분석 및 검증 연구)

  • Young Woo Cha;Gi Hyun Lee;Chang Kee Lee;Sang Bong Lee;Ohung Kwon;Chang Gyu Lee;Joo Yeoun Lee;JungMin Yun
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.20 no.spc1
    • /
    • pp.56-64
    • /
    • 2024
  • This study aims to compare and evaluate the usability of domestic and overseas XR devices. With the recent release of 'Apple Vision Pro', interest in the XR field is increasing rapidly. XR devices are being used in various fields such as defense, medical care, education, and entertainment, but the evaluation system for evaluating usability is still insufficient. Therefore, this study aims to derive improvements in domestic equipment through comparative evaluation of usability for two HMD-type devices and one glasses-type device that are released. In order to conduct the study, 20 participants in their 20s to 30s who were interested in XR devices and had no visual sensory organ-related disabilities were evaluated by wearing VR equipment. As a quantitative evaluation, electromyography through an EMG sensor and the device and body temperature of the device through a thermal imaging camera were measured. As a qualitative evaluation, the safety of wearing, ease of wearing, comfort of wearing, and satisfaction of wearing were evaluated. As a result of comparing the usability of the devices based on the results, it was confirmed that domestic HMD-type device needs improvement in the strap part.

Physiological responses and subjective sensation of human body wearing Cool Mapsi in air-conditioning environment (냉방환경에서 쿨맵시 착용에 따른 생리적 반응과 주관적 감각)

  • Kang, Noo-Ri;Na, Young-Joo
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.359-370
    • /
    • 2010
  • The purpose of this study is to test the performance of the recommended summer dressing for office man through the analysis of skin temperature changes by air-conditioning temperature. We tested two clothing combinations; formal wear with necktie and casual shirts without necktie as for Cool mapsi. 4 male subjects sat to stabilize for thirty minutes after entering artificial-climate chamber with both temperature of $25^{\circ}C$, $27^{\circ}C$ and $50{\pm}10%$ R.H. And during 60 minute experiments of simulating office work, the subjective feelings including thermal, humidity and comfort sensation, skin temperature, clothing humidity and sweat amount were measured at the equal intervals. The result is that formal wear of $25^{\circ}C$ and Cool mapsi of $27^{\circ}C$ show good values such as low skin temperature, low clothing humidity and neutral thermal sensation. And Cool mapsi of $25^{\circ}C$ shows the risk of low rectal temperature for long and static energy level of office work. Formal wear of $27^{\circ}C$ shows high values of mean skin temperature, clothing humidity and thermal sensation. Second experiment was to find the ambient temperature when the subject wearing formal wear shows the skin temperature corresponding to which he shows on Cool mapsi of $27^{\circ}C$. The air-conditioning temperature on wearing formal wear has to be $2^{\circ}C$ lower to produce the corresponding skin temperature to which shows on wearing Cool mapsi of $27^{\circ}C$. Therefore it is possible to increase room temperature to $27^{\circ}C$, when wear Cool mapsi for summer office, for skin temperature and thermal sensation are produced the same.

  • PDF

Development of Impact-based Heat Health Warning System Based on Ensemble Forecasts of Perceived Temperature and its Evaluation using Heat-Related Patients in 2019 (인지온도 확률예보기반 폭염-건강영향예보 지원시스템 개발 및 2019년 온열질환자를 이용한 평가)

  • Kang, Misun;Belorid, Miloslav;Kim, Kyu Rang
    • Atmosphere
    • /
    • v.30 no.2
    • /
    • pp.195-207
    • /
    • 2020
  • This study aims to introduce the structure of the impact-based heat health warning system on 165 counties in South Korea developed by the National Institute of Meteorological Sciences. This system was developed using the daily maximum perceived temperature (PTmax), which is a human physiology-based thermal comfort index, and the Local ENSemble prediction system for the probability forecasts. Also, A risk matrix proposed by the World Meteorological Organization was employed for the impact-based forecasts of this system. The threshold value of the risk matrix was separately set depending on regions. In this system, the risk level was issued as four levels (GREEN, YELLOW, ORANGE, RED) for first, second, and third forecast lead-day (LD1, LD2, and LD3). The daily risk level issued by the system was evaluated using emergency heat-related patients obtained at six cities, including Seoul, Incheon, Daejeon, Gwangju, Daegu, and Busan, for LD1 to LD3. The high-risks level occurred more consistently in the shorter lead time (LD3 → LD1) and the performance (rs) was increased from 0.42 (LD3) to 0.45 (LD1) in all cities. Especially, it showed good performance (rs = 0.51) in July and August, when heat stress is highest in South Korea. From an impact-based forecasting perspective, PTmax is one of the most suitable temperature indicators for issuing the health risk warnings by heat in South Korea.

Nocturnal Surface Cooling and Cold Air Transport Analysis Based on High Density Observation - A Case Study of Eunpyeong New Town in Seoul (고밀도 관측자료를 이용한 야간 지면냉각과 찬공기 이동 분석 - 서울 은평구 뉴타운 사례)

  • Yi, Chae-Yeon;Kim, Kyu-Rang;Choi, Young-Jean;Won, Hye-Young;Scherer, Dieter
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.4
    • /
    • pp.124-137
    • /
    • 2012
  • Climate analysis is important in urban planning for human comfort. Synoptic weather conditions can only resolve the 30% of local variance of wind conditions whereas 70% of the variance arise from local terrain, buildings, and other small scale thermal conditions. Climate Analysis Seoul (CAS) was developed to resolve such micro-scale climate. The Local-scale air temperature Deviation (LD) analysis map from CAS showed the co-existence of built-up and suburban areas in the study region (CR, Cold-air analysis Region) despite its small extent. Temperature, humidity, wind speed, and wind direction were monitored in CR. Hourly observed cooling rate agreed well with LD. Cold air production, transportation, and stagnation was visualized by the observed Vertical Temperature Gradient (VTG) along the small stream in CR. VTG observed at the upper-most stream can be divided into two components: radiative cooling and cold air inflow from outside. Radiative cooling exists regardless of the wind speed whereas cold air inflow occurs only with calm wind. From the regression analyses based on the wind speed, the inflow portion was determined as 84% of radiative cooling. Climate analysis in the future will be able to characterize the changes in cold air by urban development plan to support the human comfort.

The Effects of Pergola Wisteria floribunda's LAI on Thermal Environment (그늘시렁 Wisteria floribunda의 엽면적지수가 온열환경에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.115-125
    • /
    • 2017
  • This study was to investigate the user's thermal environments under the pergola($L\;7,200{\times}W\;4,200{\times}H\;2,700mn$) covered with Wisteria floribunda(Willd.) DC. according to the variation of leaf area index(LAI). We carried out detailed measurements with two human-biometeorological stations on a popular square Jinju, Korea($N35^{\circ}10^{\prime}59.8^{{\prime}{\prime}}$, $E\;128^{\circ}05^{\prime}32.0^{{\prime}{\prime}}$, elevation: 38m). One of the stations stood under a pergola, while the other in the sun. The measurement spots were instrumented with microclimate monitoring stations to continuously measure air temperature and relative humidity, wind speed, shortwave and longwave radiation from the six cardinal directions at the height of 0.6m so as to calculate the Universal Thermal Climate Index(UTCI) from $9^{th}$ April to $27^{th}$ September 2017. The LAI was measured using the LAI-2200C Plant Canopy Analyzer. The analysis results of 18 day's 1 minute term human-biometeorological data absorbed by a man in sitting position from 10am to 4pm showed the following. During the whole observation period, daily average air temperatures under the pergola were respectively $0.7{\sim}2.3^{\circ}C$ lower compared with those in the sun, daily average wind speed and relative humidity under the pergola were respectively 0.17~0.38m/s and 0.4~3.1% higher compared with those in the sun. There was significant relationship in LAI, Julian day number and were expressed in the equation $y=-0.0004x^2+0.1719x-11.765(R^2=0.9897)$. The average $T_{mrt}$ under the pergola were $11.9{\sim}25.4^{\circ}C$ lower and maximum ${\Delta}T_{mrt}$ under the pergola were $24.1{\sim}30.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average $T_{mrt}$ compared with those in the sun and was expressed in the equation $y=0.0678{\ln}(x)+0.3036(R^2=0.9454)$. The average UTCI under the pergola were $4.1{\sim}8.3^{\circ}C$ lower and maximum ${\Delta}UTCI$ under the pergola were $7.8{\sim}10.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average UTCI compared with those in the sun and were expressed in the equation $y=0.0322{\ln}(x)+0.1538(R^2=0.8946)$. The shading by the pergola covered with vines was very effective for reducing daytime UTCI absorbed by a man in sitting position at summer largely through a reduction in mean radiant temperature from sun protection, lowering thermal stress from very strong(UTCI >$38^{\circ}C$) and strong(UTCI >$32^{\circ}C$) down to strong(UTCI >$32^{\circ}C$) and moderate(UTCI >$26^{\circ}C$). Therefore the pergola covered with vines used for shading outdoor spaces is essential to mitigate heat stress and can create better human thermal comfort especially in cities during summer. But the thermal environments under the pergola covered with vines during the heat wave supposed to user "very strong heat stress(UTCI>$38^{\circ}C$)". Therefore users must restrain themselves from outdoor activities during the heat waves.

Effect of Clothing Habit on Thermoregulation of Body A Comparative Study of Skirt and Slacks (스커트와 슬랙스의 의복착용습관이 인체의 체온조절에 미치는 영향)

  • 최영희;이순원
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.6
    • /
    • pp.983-991
    • /
    • 1996
  • This study focusses on how the skirt or slacks wearing habit affects the female physiology in her daily life. The healthy female college students have been trained to wear either skirt (group A) or slacks (group B) from late August to early January in order to study the effects of clothing habit on thermoregulatory responses. Also, the themoregulatory responses have been compared the healthy students groups with a physical trained students group (group C) to examine the effects of clothing habit. The changes in body temperatures of students have been studied under the cool environmental condition (15$\pm$1$^{\circ}C$, 60$\pm$5% RH, 0.25 m/sec). The results were as follows: 1. Rectal temperature of the group A was 0.4$^{\circ}C$ lower at 36.9$^{\circ}C$ than that of the group B The groups A and B were found identical before the training, while the groups A and C were identical after the training. 2. Mean skin temperature of the group A was 1.2$^{\circ}C$ lower than that of the group B. The groups A and C were identical after the training. 3. The thermal sensation was reflected to be cool by the group A and to be cold by the group B. As for the humidity sensation, the group A felt average, whereas the group B reported between average and slightly humid. In the case of comfort sensation, the group A felt average, while the group B felt between average and slightly uncomfortable. In summary, the 18 weeks of training has provided the skirt group an improved acclimatization to the cold environment . This group also showed an insulative-hypothermic adapta lion in a cold ambient temperature, as was the case for the physical trained group. It is concluded that wearing a skirt for a long period of time can be helpful to human body through gaining of thermoregulatory abilities.