• Title/Summary/Keyword: Thermal Comfort Temperature

Search Result 469, Processing Time 0.03 seconds

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Estimation of Indoor Environment using CFD of Multi-Purpose System with a Solar Collector -Part 1, focused on floor area and number of ventilation- (태양열온수기 적용 냉난방시스템의 CFD를 이용한 실내환경 평가 -제1보 바닥면적과 환기횟수를 중심으로-)

  • Kim, Jong-Ryeol;Choi, Kyang-Hyan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • This paper has been conducted to estimate cooling capacity of the dehumidification tower using hot water from a solar water heating system as a energy source of regeneration process when the dehumidification and drying system is applied to room cooling. A solar water heating system was operated and indoor temperature distributions were simulated according to weather conditions when the concerned solution was used to dehumidify room air in the dehumidification tower. Through this simulation researches we found th following results ; It was found that air velocity through supply and return diffusers should be controlled because it can cause uncomfort in dwelling area. It was found that in the sunny morning temperatures of dwelling area 1 and 2 are higher than those of dwelling area 3 and 4. In this research all the calculation results of heating and cooling system supported by solar water heater have confirmed that its cooling capacity could not reach PMV 0, thermal comfort.

Impact of future climate change on UK building performance

  • Amoako-Attah, Joseph;B-Jahromi, Ali
    • Advances in environmental research
    • /
    • v.2 no.3
    • /
    • pp.203-227
    • /
    • 2013
  • Global demand for dwelling energy and implications of changing climatic conditions on buildings confront the built environment to build sustainable dwellings. This study investigates the variability of future climatic conditions on newly built detached dwellings in the UK. Series of energy modelling and simulations are performed on ten detached houses to evaluate and predict the impact of varying future climatic patterns on five building performance indicators. The study identifies and quantifies a consistent declining trend of building performance which is in consonance with current scientific knowledge of annual temperature change prediction in relations to long term climatic variation. The average percentage decrease for the annual energy consumption was predicted to be 2.80, 6.60 and 10.56 for 2020s, 2050s and 2080s time lines respectively. A similar declining trend in the case of annual natural gas consumption was 4.24, 9.98 and 16.1, and that for building emission rate and heating demand were 2.27, 5.49 and 8.72 and 7.82, 18.43 and 29.46 respectively. The study further analyse future heating and cooling demands of the three warmest months of the year and ascertain future variance in relative humidity and indoor temperature which might necessitate the use of room cooling systems to provide thermal comfort.

A Study on the Design Prototype Development of Underfloor Air-Conditioning System(UFAC) for Improving Indoor Environment (바닥급기 공조시스템(UFAC)을 적용한 작업공간의 실내환경 평가기법 개발연구)

  • 정광섭;한화택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.325-336
    • /
    • 2000
  • During the last decade, an increasing interest in Underfloor Air-Conditioning(UFAC) systems has emerged. The purpose of this paper is to evaluate comprehensively the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. In this paper, the physical measurements and the interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation(POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey.

  • PDF

Numerical Study on Control Factors of Defrosting Performance for Automobile Windshield Glass in Winter (수치해석을 통한 자동차 전면유리 제상성능 제어인자 연구)

  • Youn, Young-Muk;Kader, Md. Faisal;Lee, Kum-Bae;Jun, Yong-Du
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.789-794
    • /
    • 2008
  • Recently, much attention has been paid in the field of defrosting because clear windshield in vehicle without effecting the thermal comfort is realized essentially. Then in winter, defrosting performance is one of the important factors in vehicle design to make certain driver's view. In this study, the velocity profile, temperature distribution and frost melting pattern on the windshield screen have been predicted in three dimensional geometry of an automobile interior. Numerical analyses predict a detailed description of fluid flow and temperature patterns on the inside windshield screen, utilizing the flow through defroster nozzle. Numerical prediction established a good defrosting performance with the standard distance ratio and the defroster nozzle angle ranging from $30^{\circ}$ to $40^{\circ}$, which satisfy the condition of National Highway Traffic Safety Administration (NHTSA) completely.

Effect of Wear Training on Temperature Adaptability of the Obese Children (비만아동의 온도적응성에 대한 착의훈련 효과)

  • Jeong, Woon-Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.3 s.151
    • /
    • pp.407-411
    • /
    • 2006
  • This study was carried out to investigate the physiological responses of obese children after a short-term wear training and education. A ten-week program was conducted on thirteen obese elementary school children of six boys and seven girls in the 4th to the 6th grade. During the program, the children were instructed to measure daily ambient temperature and weight of their clothing. Physiological responses of the sedentary children in 100$\%$ cotton short sleeved t-shirt (0.13clo) and T/C short pants(0.09clo) were observed in the climatic chamber of 23.0$\pm$0.5$^{circ}C$ and 50$\pm$5$\%$RH before and after program. During the experiment, internal ear temperature ($T_{ear}$), seven site skin temperatures, systolic blood pressure, diastolic blood pressure, heart rate, and subjective responses of thermal comfort and thermal sensation were measured every 5minutes. Mean skin temperature($T_{sk}$) and mean arterial pressure(MAP) were calculated. Obtained data are statistically analyzed and main results are as follows. There was highly significant correlation between the ambient temperature and the total clothing weight. $T_{ear}$ and MAP were reduced in the post-program compared to the pre-program. The obese girls felt slightly warmer than the obese boys and the girls were likely to prefer lower ambient temperature in the post-program than the pre-program. It was concluded that the 10 week wear training is apt to be more applicable to the obese girls than the obese boys. However, a more comprehensive study including. diverse measurements of deep body temperature with a long-term training would be needed to clarify the improvement of temperature adaptability in the obese children.

The Physical Property of Nylon/PP Warm-up Knitted Fabric for High Emotional Garment (고감성 의류용 Nylon/PP 온감 니트 소재의 물성)

  • Kim, Hyun Ah;Jang, Hong Won;Heo, Kyoung;Kim, Seung Jin;Kwon, Sang Jun
    • Textile Coloration and Finishing
    • /
    • v.26 no.1
    • /
    • pp.22-31
    • /
    • 2014
  • This study investigated the physical properties of warm up yarns and their knitted fabrics including the dye affinity and color fastness to washing of these knitted fabrics according to the various dyeing times and temperatures on dyeing process. The results were summarized as follows. The tenacity of Nylon/PP warm-up yarn was 4g/d and breaking strain was 4.5%. The wet and dry thermal shrinkages were higher than those of PET warm-up yarn. The maximum heat flow rate(Qmax) of Nylon/PP warm-up knitted fabric was lower than that of PET warm-up knitted fabric and heat keeping rate(a) of Nylon/PP warm-up knitted fabric was higher as 47% than that of PET warm-up knitted fabric. It was shown that the shape retention and wearing comfort of Nylon/PP warm-up knitted fabric were better than those of PET warm-up knitted fabric. The dye-affinity(K/S) of Nylon/PP warm-up knitted fabric showed maximum value at the dyeing condition of 40minute or 50minute dyeing time with $80^{\circ}C$ dyeing temperature, but PET warm-up knitted fabric showed maximum value at the 30minute or 40minute with $110^{\circ}C$ dyeing temperature. Finally, the color fastness to washing of Nylon/PP warm-up knitted fabric showed good value as between 4 and 5 grade.

Thermal Environment and Bedclimate on Ondol during Sleeping in Each Season (온돌에서 수면시의 계절별 침실내 온열환경과 침상기후)

  • 이순원;권수애
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.7
    • /
    • pp.1162-1172
    • /
    • 1997
  • The actual thermal environment and bedclimate on Ondol were investigated by the regions and housing styles in each season. The subject were sixty healthy men and women, 30 of them live in apartment, and 30 of them live in detached house. 20 of them live in Wonju, 20 of them live in Cheongju and 20 of them live in Pusan. The results are as follows: 1) The subject slept in this conditions; 23.1$\pm$2.4$^{\circ}C$ and 38$\pm$8.8% RH in spring, 27.1$\pm$1.5$^{\circ}C$ and 68$\pm$6.4% RH in summer, 27.1$\pm$1.7$^{\circ}C$ and 47$\pm$11.1% RH in autumm, and 24.9$\pm$3.3$^{\circ}C$ and 41$\pm$10.7% R.H in winter The temperatures of the floors were 38.6$\pm$5.$0^{\circ}C$ in the spring, 26.7$\pm$1.9$^{\circ}C$ in the summer, 29.4$\pm$4.7$^{\circ}C$ in the autumm, and 30.0$\pm$5.8$^{\circ}C$ in the winter. 2) Each thickness of the quilts was thinner in the summer than in any other season, but the differences in the thickness of each mattress was not significant by the seasons. 3) The differences of the bedclimate and the clothing microclimate were significant by the regions and housing in each seasons. The inside of temperature and humidity of sleepwrar were highest in summer. The bedclimate showed high correlation with the clothing microclimate. 4) The differences in the sensation which the subjects felt about temperature and comfort of the bedroom conditions were not significant by the seasons, regions, or housing styles. But the subjects felt more humid in the summer and spring than in the autumm and winter.

  • PDF

Effects of Clothing Material Dyed with Astringent Persimmon Extract upon Exercise-Induced Thermal Strain and Sensory Responses in a Warm Environment

  • Park, Shin-Jung;Shin, Hye-Sun;Chung, Hee-Chung
    • International Journal of Human Ecology
    • /
    • v.16 no.2
    • /
    • pp.1-9
    • /
    • 2015
  • This study investigated the effects of persimmon-dyed clothing materials upon thermophysiological responses and subjective comfort sensations during exercise and rest in a warm environment. Six healthy, untrained women participated in two separate testing sessions, with cotton materials dyed with astringent persimmon extract (DC) and undyed cotton materials (UDC). The physical characteristics associated with heat and moisture transfer were improved in DC; also, stiffness, anti-drapery stiffness and crispness in the primary hand values were higher in DC. The experimental protocol consisted of a 10-min rest, 15-min exercise on a treadmill (at ${7km{\cdot}h^{-1}}$) and 25-min recovery at $28{\pm}0.2^{\circ}C$ and $50{\pm}3%\;RH$. The results were as follows: When wearing DC rather than UDC, mean body temperature, heart rate, heat storage and body mass loss were significantly lower during the whole experimental period. Clothing microclimate temperature showed different profiles between the two clothing materials, being lower with DC than UDC during the first half of exercise and the second half of recovery. Clothing microclimate humidity was significantly lower with DC than UDC during the whole experimental period. When wearing UDC, subjects felt significantly warmer and less comfortable during exercise, and sensed greater humidity during exercise and recovery. These results suggest that eco-friendly clothing materials dyed with astringent persimmon extract can reduce exercise-induced heat load and improve subjective sensations when exercising and resting in a warm environment, due to greater heat dissipation from the body to the outside environment compared with undyed clothing materials.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.