An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구)

  • 김용이;임재한;한여명;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

Wear Evaluation of Protective Mask according to Internal Volume (보호마스크의 내부 부피에 따른 착용 평가)

  • Eom, Ran-i;Park, Sunhee;Park, Soyoung;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.4
    • /
    • pp.626-638
    • /
    • 2020
  • In this study, protective masks were designed in varying internal volume and analyzed in regards to wearing effect. Masks were measured by surface temperature and subjective wear evaluation. Four experimental masks were created with an increasing distance between the mask center line and nose in increments. The distances were set at 0.0 cm (M0), 2.0 cm (M2), 4.0 cm (M4), and 6.0 cm (M6). The area and volume of each experimental mask was measured and both measurements had a positive correlation with the set distances. Among the experimental masks, M2 was the most breathable. The heat between the face and the mask created by exhalation was able to escape from the mask and provided the highest comfort sensation when worn. Conversely, an internal volume that is too large would decrease its comfort because repetitive breathing deforms the appearance of the mask and adversely affects its fit. Therefore, creating and maintaining the optimal internal volume of the M2 mask is important to achieve maximum thermal sensation and ease of wear.

Thermal Performance Evaluation at corners of the External wall of Modern New Han-oks using Temperature Difference Ratio inside (내표면 온도차 비율(TDRi) 분석을 통한 현대 신한옥 외벽 모서리 부위 단열성능 평가)

  • Lee, Ju-Yeob;Song, Min-Jeong;Lee, Tai-Gang;Kim, Sun-Woo;Cheon, Deuk-Youm
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.103-112
    • /
    • 2016
  • Recently, many New Han-oks have been constructing in all over the country to popularize as a type of green house. But, achievement of thermal performance of external wall is still the very important issue to become popular. Purpose: The purpose of this study is to verify the thermal performance level of modern New Han-ok through Temperature Difference Ratio inside(TDRi) analysis at corners of the external wall in Han-ok. Method: To achieve this goal, measurements were carried out in 12 Han-oks(experimental mock-up(1), exhibition Han-ok(1), happy village Han-oks(10)) by taking a infra-red thermography using thermal video system. Following are analysis items about connection joint between wall and wood columns of external wall conditions; the part between external wall and external wall(2D), external wall and ceiling(or floor)(2D), 2 external walls and ceiling(or floor)(3D) and so on. Result: It was analyzed that the probability of condensation at most of connection joint appear high and TDRi of 3D corners is higher than that of 2D corners in general. It means that the development of construction techniques about connection joint between wood columns and external wall is still required. The results of this study may be used to improve the construction technology of new Han-ok and as a basis for the specifying the desired thermal comfort environment of dwelling.

The Study on the Physiological Response in Wearing Sportswear in Two Different Environments

  • Kwon, Oh Kyung;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.5
    • /
    • pp.416-422
    • /
    • 2000
  • In this study, to find out the physiological reaction of the human body and the sensation of comfort when people are wearing sportswear which is made of waterproof breathable fabrics under general environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec) and rainy environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec, rainfall : 250 1/hr), we made an experiment with sportswear in an artificial climate chamber and studied the thermal physiological response and subjective sensation. Mean skin temperature of the subjects was low and had a big range of fluctuation in rainy environmental conditions of two condition. Temperature started to increase at the beginning of the exercise, reached the maximum at the 2nd level of the exercise and then started to decline. Rectal temperature showed a slighter increase and bigger range of fluctuation in general conditions than in rainy conditions. Except clothing micro climate in rainy conditions, temperature and humidity and their range of fluctuation around back were higher than those around chest. Humidity was high and had wide range of fluctuation in general conditions. Heart rate was 4.4 beats/min higher in general conditions. In subjective test on rainy conditions, the feeling of discomfort increased due to the raindrops fallen on the skin. Unlike that in general conditions, cold sensation increased and humidity sensation reached to the peak after the exercise. In wearing sportswear made of shape memory breathable waterproof fabric, controlling function over a small amount of heat and water was distinctive while it turned out to be not so comfortable over a large amount of heat and water. Through this, the limitation of shape memory breathable waterproof fabric was recognised.

  • PDF

Analysis of Changes in Temperature and Humidity by Material Combination Using 3D Printing (3D 프린팅을 활용한 재료조합에 따른 온습도 변화 분석)

  • Lee, Heeran;Kim, Soyoung;Lee, Yejin;Lee, Okkyung
    • Fashion & Textile Research Journal
    • /
    • v.24 no.1
    • /
    • pp.127-137
    • /
    • 2022
  • Recently, various clothing items are being developed using 3D printing technology, but comfort has become an issue while wearing them for a long time. Therefore, this study researched on how the temperature and humidity of the devices developed by 3D printing change depending on the material combination. Five types of material combinations (EVA foam, TPU density 10%, TPU density 30%, EVA foam+TPU density 10%, and EVA foam+TPU density 30%) were selected as variables, and the experiment was conducted for two different cases with and without a cover. All the ten types of samples were placed on the hot plate set at 36℃, and the surface temperature and humidity were measured at three different points for 10 minutes. As a result, the case with only TPU showed the greatest temperature change while the case with 100% EVA foam showed the least temperature change. The humidity of the surface layer gradually decreased with time for 100% EVA foam. For the case with TPU materials, the moisture was transferred to the surface layer at first, thereby increasing the humidity but then dropped significantly. Meanwhile, the cases with the cover on showed similar tendencies of change in both temperature and humidity where the overall temperature and humidity delivery were slow.

An Energy Performance Evaluation of UFAD System under the Various Conditions of Thermal Load (실내 부하조건에 따른 바닥공조 시스템의 에너지 성능 평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Kim, Kyung-Ah;Yu, Ki-Hyung;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.14-19
    • /
    • 2013
  • The present study has been conducted for evaluating and comparing the performance of the underfloor air distribution system(UFAD) and the ceiling based air distribution system(CBAD) under cooling condition. Simulations and experiments were carried out for verifying the model by TRNSYS program about UFAD and CBAD. The results of simulation for various conditions of thermal load are summarized as followings. UFAD had an advantage for making thermal comfort because of lower temperature of the floor surface. Moreover, UFAD showed lower fan power about 30~50% than CBAD under the same conditions of thermal load. The energy saving rates of UFAD were increased to 17.7% in proportion to the thermal load on unoccupied zone(lighting). Ultimately, additional investigations should be done for analyzing optimized operating conditions of UFAD with considering the thermal performance of building envelop and the thermal load.

A Study on the Comfort and Skin Temperature on the Clothing Environment in the Taegu City during Years -Concentrated on indoor uniforms- (섬유·패션 산업 DB 구축을 위한 대구지역의 연간 피복환경내의 피부온과 쾌적성 -실내 제복을 중심으로-)

  • Ryo, Duck-Hwan;Lee, Uk-Ja;Kim, Seong-Jin;Song, Min-Kyo;Cho, Ji-Hyun;Jung, Meung-Sun
    • Fashion & Textile Research Journal
    • /
    • v.1 no.4
    • /
    • pp.376-386
    • /
    • 1999
  • The purpose of this study was to determine the physiological responses and the Subjective sensations of the human subjects when 10 human subjects(5 males and 5 females) were tested with selected ensembles, including the uniforms of students, industrial and bank workers. For the study, garment material and design were selected, which was mostly used in Taegu area by the survey. Thermal manikin and the human subject tests were performed. The results were as follows: 1. There was no significant difference among skin temperature of head by season and among that of breast and back by all variables, however, there was a significant difference among that of belly by gender and that of thigh and shank by season. In addition, there was no significant difference among rectal temperature by gender and season, but there was a significant difference by uniform. 2. Mean skin temperature of male subjects was significantly higher than that of female subjects. Specially in lower environmental condition, the difference got larger. 3. There was a significant difference among purse rate of subjects by uniform, but there was no significant difference among those by gender and season. There were no significant difference among maximum and minimum blood pressure by gender, uniform, and season. 4. There was a significant difference in temperature of chest among gender and uniform, and there was no significant difference in temperature of back by season. In addition, There was a significant difference in humidity of back by uniform and season but there were no significant difference in that by gender. 5. There was a significant difference in humidity sensation by gender, comfort sensation by uniform and season, but there was no significant difference thermal sensation by uniform and season. 6. For the result of regression analysis, we got the regression equations as follows: Clo=1.810 Thickness+0.525, Clo=0.475 weight+0.863.

  • PDF

Fuzzy Control Application Strategy for Energy Saving in HVAC System (공조시스템의 에너지절약을 위한 Fuzzy제어 적용방안 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.2
    • /
    • pp.31-37
    • /
    • 2007
  • The fuzzy control algorithm for HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with fuzzy control are supply air temperature, chilled water temperature and condenser temperature. This study has been done by using TRNSYS program in order to analyze the HVAC system response. As a result, the fuzzy control algorithm with PID algorithm shows good energy performance in comparison with conventional one.

  • PDF

Measurements of Temperature Distribution on Human Body Surface using Multi-Channel Skin Temperature Sensors (다채널 피부온 센서를 이용한 인체표면 온도분포의 측정)

  • 한화택;김민규;박명규;이성수
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.205-209
    • /
    • 2002
  • 인체의 피부온도는 쾌적성과 감성에 크게 영향을 미치며 의류의 개발이나 건축환경의 설계 등에 활용되고 있다. 단순히 몇몇 측정점에서의 피부온도 데이터가 아니라 인체표면에 걸친 온도분포를 파악함으로써 다양한 정보를 이용하여 보다 광범위한 응용분야에 활용될 수 있을 것이다. 현재 인체표면의 온도분포를 측정하기 위하여 대부분 적외선 열화상 카메라를 활용하고 있다 그러나 열화상 카메라는 서미스터 등을 이용한 피부온 센서에 비하여 온도분해능이 떨어지며 특히 의복내의 피부온을 측정하는 것이 불가능하고 노출된 인체표면에 대해서만 측정이 가능하다. 따라서 본 연구에서는 피부온 센서를 이용한 인체표면 온도분포 측정시스템을 개발하기 위하여 각 센서의 위치와 간격, 그리고 인체 곡면을 따라서 보간법에 따라 온도분포 결과에 미치는 영향을 파악하고 적외선 화상 결과와 비교하고자 한다.

  • PDF

Dynamic Simulation of a Dedicated Outdoor Air-conditioning System (외기 전용 공조기의 동특성 시뮬레이션)

  • Kim, Jung-Min;Kim, Young-Il;Chung, Kwang-Seop;Park, Seung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF