• Title/Summary/Keyword: Thermal Changes

Search Result 1,948, Processing Time 0.029 seconds

The Effect of Fumed Silica Loading on the Thermal Stability of Fluorosilicone Composites

  • Muhammet Iz;Jinhyok Lee;Myungchan Choi;Yumi Yun;Hyunmin Kang;Jungwan Kim;Jongwoo Bae
    • Elastomers and Composites
    • /
    • v.57 no.4
    • /
    • pp.165-174
    • /
    • 2022
  • The effect of fumed silica loading on the thermal stability and mechanical properties of fluorosilicone (FVMQ) rubber was investigated. The distribution of fumed silica inside FVMQ was characterized using scanning electron microscopy, and the thermal stability of composites was evaluated using thermogravimetric analysis and by the changes in mechanical performance during thermo-oxidative aging. The function mechanism of fumed silica was studied by Fourier transform infrared spectroscopy. The results show that with increasing silica content, the crosslink density of composites, the modulus at 100%, and tensile strength also increased, whereas the elongation at break decreased. Furthermore, increasing the silica content of composites increased the initial decomposition temperature (Td) and residual weight of the composite after exposure to nitrogen. In addition, the thermal oxidative aging experiment demonstrated improved aging resistance of the FVMQ composites, including lower change in tensile strength, elongation at break, and modulus at 100%.

Enhancing Thermal Conductivity in Epoxy Composites with Functionalized Boron Nitride Nanosheets

  • Yang Soo Kim;Ik-Tae Im;Jong Seok Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.12
    • /
    • pp.503-510
    • /
    • 2023
  • This comprehensive study delves into the intricate process of exfoliating and functionalizing boron nitride nanosheets (BNNSs) extracted from hexagonal boron nitride (h-BN), and meticulously explores their potential application within epoxy composites. The extensive research methodology encompasses a sequence of treatments involving hydrothermal and sonication processes aimed at augmenting the dispersion of BNNSs in solvents. Leveraging advanced analytical techniques such as Raman spectroscopy, X-ray diffraction, and FTIR spectroscopy, the study rigorously analyzes a spectrum of changes in the BNNS's properties, including layer count variations, interlayer interactions, crystal structure modifications, and the introduction of functional groups. The research also rigorously evaluates the impact of integrating BNNSs, specifically glycidyl methacrylate (GMA)-functionalized BNNSs, on the thermal conductivity of epoxy composites. The conclusive findings exhibit notable enhancements in thermal properties, predominantly attributed to the enhanced dispersion of fillers and enhanced interactions within the epoxy matrix. This pioneering work illuminates the wide potential of functionalized BNNSs for significantly enhancing the thermal conductivity of epoxy composites, paving the way for advanced materials engineering and practical applications.

Nonlinear forced vibration of axially moving functionally graded cylindrical shells under hygro-thermal loads

  • Jin-Peng Song;Gui-Lin She;Yu-Jie He
    • Geomechanics and Engineering
    • /
    • v.36 no.2
    • /
    • pp.99-109
    • /
    • 2024
  • Studying the dynamic behavior of axially moving cylindrical shells in hygro-thermal environments has important theoretical and engineering value for aircraft design. Therefore, in this paper, considering hygro-thermal effect, the nonlinear forced vibration of an axially moving cylindrical shell made of functionally graded materials (FGM) is studied. It is assumed that the material properties vary continuously along the thickness and contain pores. The Donnell thin shell theory is used to derive the motion equations of FGM cylindrical shells with hygro-thermal loads. Under the four sides clamped (CCCC) boundary conditions, the Gallekin method and multi-scale method are used for nonlinear analysis. The effects of power law index, porosity coefficient, temperature rise, moisture concentration, axial velocity, prestress, damping and external excitation amplitude on nonlinear forced vibration are explored through parametric research. It can be found that, the changes in temperature and humidity have a significant effect. Increasing in temperature and humidity will cause the resonance position to shift to the left and increase the resonance amplitude.

Effectsd of posture on physiological thermal responses with Ondol heating system (온돌난방에서의 자세에 따른 온열생리적 반응의 성차)

  • 신정화;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.8
    • /
    • pp.1020-1031
    • /
    • 1998
  • This study was done to investigate thermal reponses and to obtain the basic information of thermal comfort by sex and posture under the Ondol heating system. Six healthy males and females were exposed to Ondol(Room Temp.: 25$\pm$1$^{\circ}C$, 50$\pm$10%R.H, Floor Temp.:30$\pm$1$^{\circ}C$) on the of posture such as sitting, lying aside and supine on the floor for 30 minutes after 30 minutes' control phase. During the experiment, rectal temperature, skin temperature of 10 areas, local sweating rate, clothing microclimate, subjective sensation were measured. Rectal temperature gradually decreased and mean skin temperature grad-ually increased both male and female in any posture. There was not significant difference between male and female in rectal temperature and mean skin temperature. There were significant difference among the postures in rectal temperature(p<0.001) and mean skin temperature(p<0.001). In lying aside and supine on the floor, appearances of change and changes in rectal temperature and mean skin temperature were large, changes of weight were small. In sitting on the floor, appearances of change and changes in rectal temperature and mean skin temperature were small, changes of weight were large. The trunk skin tem-perature was higher in female than in male, but the extremity skin temperature was higher in male than in female. In sitting on the floor, foot skin temperature(p<0.001) was higher than any other local skin temperature. In supine on the floor, back skin temperature(p<0.001) was higher than any other local skin temperature.

  • PDF

Effects on the Thermal Changes of Kok-Chi$(LI_{11})$ and Yong-Hyang$(LI_{20})$ Following Acupuncture on Hap-Kok $(LI_{4})$ in Man (합곡(合谷)$(LI_4)$ 자침(刺鍼)이 곡지(曲池)$(LI_{11})$와 영향(迎香)$(LI_{20})$ 영역(領域) 온도변화(溫度變化)에 미치는 영향(影響))

  • Song, Jae-Soo;An, Seong-Hun;Kim, Jae-Hyo;Kim, Kyung-Sik;Sohn, In-Chul
    • The Journal of Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.271-295
    • /
    • 1998
  • This study was performed from October 1997 to March 1998 on 42 healthy students to observe the effects of acupuncture at Hap-kok (LI4) according to the meridian and qi-xue(氣血) phenomenon of oriental medicine's theory. Skin temperature on the Kok-Chi(LI11) and Yong-Hyang(LI20) were measured by D. I. T. I. (Digital Infrared Thermograph Imaging) before acupuncture stimulation, 1min after and after acupuncture stimulation during 10 min. 1. In healthful man, average skin temperature about Kok-Chi area was in low than Yong-Hyang, and temperature change for 10 min was decreased significantly. 2. In Kok-Chi, the temperature decrease index of execution was shown in low than control. 3. When the temperature of Yong-Hyang(left) was higher, the index was shown in high than control. 4. When the temperature of Kok-Chi (left) was higher, execution temperature change was decreased significantly than control. The above results indicates that D. I. T. I. was a useful method to observe follow-up the effects and changes by acupuncture stimulation on objective evaluation of phenomenon for the meridian system. Thus, acupuncture on LI4 affects to thermal changes of ST25 and LI4, but exact examination of thermal changes on ST25 will have to be.

  • PDF

Evaluation of Soil Health Affected by Soil Remediation Technologies and Its Processes (토양정화 공법 및 단위공정에 따른 토양건강성 평가)

  • Kim, Mintchul;Chun, Mihee;Kim, Jungsun;Park, Minjeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.6
    • /
    • pp.36-46
    • /
    • 2021
  • The Soil Health Index (SHI) developed by Park et al. (2021) is used to evaluate soil health on remediated soils collected from several remediation project sites and monitored the changes of SHI during the remediation process of land farming, soil washing, and thermal desorption. In the case of land farming, the soils remediated below a legal standard didn't show any significant changes in indices of SHI except the downgrade of available phosphate from medium to a low level. The SHI scores were ranged from 52 to 56 in the contaminated soil and 54 to 57 in the remediated soil. With soil washing, bulk density changed from high to a low level, and available phosphate was lowered from medium to low level. As the SHI scores were evaluated as 58 to 63 for contaminated soil and 38 to 42 for remediated soils. For thermal desorption, soil respiration rate was reduced from high to low level and SHI was scored as 50 to 51 for contaminated soils and 43 to 47 for remediated soils. Even though any abrupt changes of the SHI in remediated soils were not identified in the soils used in this study, it is expected that soil in different conditions such as types and concentrations of contaminant and soil characteristics would result in distinguished changes of the SHI. There is a room for more studies collect diverse information on SHI across the country.

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

Analysis of the Surface Urban Heat Island Changes according to Urbanization in Sejong City Using Landsat Imagery (Landsat영상을 이용한 토지피복 변화에 따른 행정중심복합도시의 표면 열섬현상 변화분석)

  • Lee, Kyungil;Lim, Chul-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.3
    • /
    • pp.225-236
    • /
    • 2022
  • Urbanization due to population growth and regional development can cause various environmental problems, such as the urban heat island phenomenon. A planned city is considered an appropriate study site to analyze changes in urban climate caused by rapid urbanization in a short-term period. In this study, changes in land cover and surface heat island phenomenon were analyzed according to the development plan in Sejong City from 2013 to 2020 using Landsat-8 Operational Land Imager/Thermal Infrared Sensor (OLI/TIRS) satellite imagery. The surface temperature was calculated in consideration of the thermal infrared band value provided by the satellite image and the emissivity, and based on this the surface heat island effect intensity and Urban Thermal Field Variance Index (UTFVI) change analysis were performed. The level-2 land cover map provided by the Ministry of Environment was used to confirm the change in land cover as the development progressed and the difference in the surface heat island intensity by each land cover. As a result of the analysis, it was confirmed that the urbanized area increased by 15% and the vegetation decreased by more than 28%. Expansion and intensification of the heat island phenomenon due to urban development were observed, and it was confirmed that the ecological level of the area where the heat island phenomenon occurred was very low. Therefore, It can suggest the need for a policy to improve the residential environment according to the quantitative change of the thermal environment due to rapid urbanization.

Thermal Deformation Analysis of an Orbital Grinding System Grinding Process (오비탈 연삭시스템의 연삭가공 열변형 오차 해석)

  • Lee, Hyeon Min;Choi, Woo Chun;Cho, Chang Rae;Cho, Soon Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.595-600
    • /
    • 2016
  • An orbital grinding system uses a special motion to machine crankshafts in ships. When a crankshaft is operated, eccentric pins rotate and a grinding wheel moves in order to grind the pins. Thermal error caused by heat generated in the grinding process decreases the quality of the final product. In this study, the thermal error of an orbital grinding system caused by heat generation was investigated in order to predict the extent of thermal error that can occur during the grinding process. Since the machine position changes during orbital grinding, the pin part is divided into 30 degree intervals and heat is generated. Total thermal error was measured by summing the thermal errors associated with the pin and the grinding wheel. Total thermal error was found to reach a maximum at 60 degrees and a minimum at 210 degrees because of the shape of the crankshaft.

A study of the simulation of thermal distribution in an aquifer thermal energy storage utilization model (대수층 축열 에너지 활용 모델의 온도 분포 시뮬레이션 연구)

  • Shim, Byoung-Ohan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.697-700
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) system can be very cost-effective and renewable energy sources, depending on site-specific parameters and load characteristics. In order to develop an ATES system which has certain hydrogeological characteristics, understanding of the thermo hydraulic processes of an aquifer is necessary for a proper design of an aquifer heat storage system under given conditions. The thermo hydraulic transfer for heat storage is simulated using FEFLOW according to two sets of pumping and waste water reinjection scenarios of heat pump operation in a two layered confined aquifer. In the first set of model, the movement of the thermal front and groundwater level are simulated by changing the locations of injection and pumping well in seasonal cycle. However, in the second set of model the simulation is performed in the state of fixing the locations of pumping and injection well. After 365 days simulation period, the temperature distribution is dominated by injected water temperature and the distance from injection well. The small temperature change is appears on the surface compared to other slices of depth because the first layer has very low porosity and the transfer of thermal energy are sensitive at the porosity of each layer. The groundwater levels and temperature changes in injection and pumping wells are monitored to validate the effectiveness of the used heat pump operation method and the thermal interference between wells is analyzed.

  • PDF