• 제목/요약/키워드: Thermal Capacity

검색결과 1,279건 처리시간 0.025초

Analysis of Supply Airflow Control by a Stratified Thermal Model in a VAV System

  • Kim, Seo-Young;Moon, Jeong-Woo;Cho, Hyung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.46-56
    • /
    • 2001
  • The present study concerns the numerical simulation of a supply airflow control in a variable air volume (VAY) system. A stratified thermal model (multi-zone model) is suggested to predict a local thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of an air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated. Further, the influence of control parameters such as the supply air temperature, the PI control factor and the thermostat location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (single zone model) may overestimate the time taken to the set point temperature. It is also found that there exist the appropriate ranges of the control parameters for the optimal airflow control of the VAV system.

  • PDF

고속 전철에서 디스크 브레이크의 열거동에 관한 유한요소해석 (Finite Element Analysis of Thermal Behaviours of a Disk Brake in High-Speed Trains)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • 제14권1호
    • /
    • pp.28-36
    • /
    • 1998
  • This paper presents the thermal behaviours of a solid type disk brake for a high-speed train. The thermal behaviours of a brake disk with 50mm thickness shows good performance compared with 45mm thickness of a disk because of a high specific heat capacity. The FEM results show that the thickness of the disk with a same weight of the brake disk should be increased for a good flexibility of the contact thermal problems. Therefore, the ratio between the pad and disk in diameter may be reduced and the thickness of a disk increased.

매스 콘크리트 구조물의 수화열 및 응력 해석의 민감도 분석 (Sensitivity Study of Thermal Stresses in Mass Concrete Structures)

  • 차수원;김광수
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.160-167
    • /
    • 2001
  • Cracking in connote structures is one of the main issues of structural design next to ensuring the load-bearing capacity. Thermal analysis is used to prevent thermal mucking, but concrete properties are uncertain variable, and analysis results have uncertainty, too. In this study, sensitivity analysis is performed to investigate the effect of conductivity, specific heal and pouring temperature. The results show that lower conductivity and higher specific heat increase the maximum temperature and maximum tensile stress. The structure with internal restraint is mostly influenced by the change of conductivity and specific heat.

  • PDF

동절기 옥외 수영장 시설의 운영을 위한 바닥난방 성능평가 및 설계기준에 관한 사례연구 (Evaluation of Floor Heating Performance and Design Criteria for Operating an Outdoor Swimming Pool During Winter : A Case Study)

  • 조진균;우경헌;김진호
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.289-296
    • /
    • 2017
  • This study aimed to analyze the deck floor heating system of an outdoor swimming pool in terms of the thermal capacity/output and the surface temperature distribution based on the outdoor temperature, to design for anti-freezing during winter. Through the transient heat transfer simulation with PHYSIBEL and theoretical equations, the surface temperature distribution of the floor heating system at two outdoor conditions in Jeju, were calculated and evaluated. The results indicate that the specific thermal output required for maintaining $4^{\circ}C$ surface temperature at the design outdoor temperature of $0.1^{\circ}C$, was about $90W/m^2$. This performance analysis can be applied for future design criteria, including optimizations of system capacity and size.

빙축열시스템의 실질적인 최대 축열 가능량 예측 (Prediction of practically chargeable cold energy in an ice storage system)

  • 이대영;강병하;김민수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

CNT 함량에 따른 전력케이블용 반도전층 재료의 열적 특성 (Thermal Properties of Semiconducting Materials for Power Cable by Carbon Nanotube Content)

  • 양종석;이경용;신동훈;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.570-575
    • /
    • 2006
  • In this paper, we have investigated thermal properties by changing the content of carbon nanotube, which is component part of semiconductive shield in underground power transmission cable. Heat capacity (${\Delta}H$), glass transition temperature (Tg) and melting temperature (Tm) were measured with the samples of eight, through DSC (Differential Scanning Calorimetry), and the measurement ranges of temperature selected from $-100[^{\circ}C]\;to\;100[^{\circ}C]$ with heating temperature selected per $4[^{\circ}C/min]$ Also, high temperature, heat degradation initiation temperature, and heat weight loss were measured by TGA (Thermogravimetric Analysis) in the temperature from $0[^{\circ}C]\;to\;700[^{\circ}C]$ with rising temperature of $10[^{\circ}C/min]$. As a result, the Glass transition temperatures of the sample were showed near $-20[^{\circ}C]{\sim}25[^{\circ}C]$, and the heat capacity and melting temperature from the DSC was increased according to increasing the content of carbon nanotube, while, thermal diffusivity was increased according to increasing the content of carbon nanotube. Also, heat degradation initiation temperature from the TGA results was increasing according to increasing the content of carbon nanotube with CNT/EEA. Therefore, heat stabilities of EVA, which contained the we VA (vinyl acetate), showed the lowest.

AB5계 합금에 있어서 수소 흡수-방출 cycling에 따른 수소 저장 특성 변화 (Changes of Hydrogen Storage Properties upon Hydrogen Absorption-Desorption Cycling in AB5-type Alloys)

  • 노학;최전;정소이;최승준;박충년
    • 한국수소및신에너지학회논문집
    • /
    • 제12권3호
    • /
    • pp.177-189
    • /
    • 2001
  • T hydrogen absorption-desorption behavior induced by thermal or hydrogen pressure cycling in a closed system was observed in hydrogen storage alloys, $(La-R-Mm)Ni_{4.5}Fe_{0.5}$, $MmNi_4Fe_{0.85}Cu_{0.15}$ and $(Ce-F-Mm)Ni_{4.7}Al_{0.2}Fe_{0.1}$. Thereby (La-R-Mm), Mm and (Ce-F-Mm) refer to La-rich mischmetal, mischmetal and Ce-free mischmetal respectively. As the results, it is found that the alloy stabilities during thermal cycling varies with alloy composition change. The highest stability occurs in $MmNi_4Fe_{0.85}Cu_{0.15}$ and the lowest stability in $(La-R-Mm)Ni_{4.5}Fe_{0.5}$. Comparing hydrogen pressure cycling with thermal cycling, pressure cycling causes severer degradation of the alloy $(Ce-F-Mm)Ni_{4.7}Al_{0.2}Fe_{0.1}$ than thermal cycling. When the 1500 times-cycled alloy is annealed at $400^{\circ}C$ for 3hrs under 1 atm of hydrogen pressure the hydrogen storage capacity is recovered only partially but not completely to the initial capacity. The amount of capacity loss after annealing is larger in the hydrogen pressure cycled samples than in the thermal cycled, suggesting an incoming of impure gas during hydrogen pressure cycling.

  • PDF

핀 부착 U형 복사튜브 버너의 열전달 및 연소성능 실험 (Heat Transfer and Combustion Characteristics and Performance of U type Radiation Tube Burner with fin)

  • 이현찬;유현석;이중성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.516-521
    • /
    • 2001
  • Present study deals with combustion characteristics and performance of U type radiation tube burner with fin which combustion capacity is 30,000kcal/hr and the maximum capacity of supply fuel is $30Nm^{3}/hr$. Temperature difference of radiation tube is about $173^{\circ}C$ at 25% capacity and this show relatively small temperature difference for convenient type. Thermal efficiency is satisfactory as $72{\sim}81%$. Also, radiative efficiency of radiation tube is $52{\sim}73%$. The efficiency of heat exchanger is $27{\sim}37%$. Therefore, radiative efficiency is improved to $1{\sim}10%$ after installing fin.

  • PDF

최적 열원용량 산정을 위한 모델건물 공조부하 시뮬레이션 분석 (Thermal Load Simulation Analysis on Model Building Estimating Optimum Heat Source Capacity)

  • 박종일;김세환;이성
    • 설비공학논문집
    • /
    • 제19권6호
    • /
    • pp.427-433
    • /
    • 2007
  • Generally, H.V.A.C load capacity in early planning phase can presume with maximum thermal load. Basic data can prove by air conditioning equipment system data analysis at existing building. There are poor and not reliable alternative presentation. In this paper, measured data after use H.V.A.C load calculation K-load program reply choosing standard building and variables simulation. And I founded peak load correlation graph and mode for several kinds of variable and contents of size. I wish that equipment designer is beaconed to produce optimum capacity at building as quantitative through this result.

Part-load Performance of a Screw Chiller with Economizer using R22 and R407C

  • Chang, Young-Soo;Kim, Young-Il;Lee, Yong-Chul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2005
  • Screw compressor chillers are widely used in refrigeration for capacity over 30 RT. In general, chillers operate under part-load conditions during most of the time. Therefore, information on the characteristics of part-load is very important for better chiller performance and energy economy. In this study, performance tests of screw chiller with economizer using R22 and R407C under part-load conditions have been performed for various secondary fluid temperatures. Adoption of an economizer system increased the cooling capacity and improved COP except for lower part-load condition when economizer volume ratio is 1.01. For the same cooling capacity condition at part-load, COP's of both non-economizer and economizer system showed similar values.