• Title/Summary/Keyword: Thermal Capacity

Search Result 1,284, Processing Time 0.035 seconds

Quality Characteristics of Meat Analogs through the Incorporation of Textured Vegetable Protein and Tenebrio molitor Larvae in the Presence of Transglutaminase

  • Yea-Ji Kim;Jeong Heon Kim;Ji Yoon Cha;Tae-Kyung Kim;Hae Won Jang;Dong-Hyun Kim;Yun-Sang Choi
    • Food Science of Animal Resources
    • /
    • v.44 no.5
    • /
    • pp.1028-1039
    • /
    • 2024
  • Alternative protein sources with greater nutritional value and a lower environmental footprint have recently attracted interest in the production of meat substitutes. However, it is required that these alternatives mimic the texture and structure of meat. This study investigated varying ratios of textured vegetable proteins (TVP) to Tenebrio molitor larvae (brown mealworm; TM) with the addition of transglutaminase (TG) to determine the quality characteristics of these emulsions. The results demonstrated low protein solubility of the emulsions as TVP content increased. Furthermore, when the proportion of TM was high, the TG-treated emulsion had a low pH. Additionally, when there was a high TM ratio to TVP in the TG treatment, the emulsions demonstrated better thermal stability and water holding capacity. Regarding the rheological properties of the emulsion, both the frequency-dependent storage modulus (G') and loss modulus (G'') increased as the proportion of TVP in the emulsion increased with and without the addition of TG. Differential scanning calorimetry analyses demonstrated two protein denaturation peaks in all treatments, with high peak temperatures for both treatments with a high proportion of TM. The hardness and chewiness of the emulsion were highest in the treatment (T6 and T8) with TG, and the gumminess of the emulsion was greatest when TM only or when equal ratios of TVP and TM were treated with TG, respectively. In conclusion, the addition of TM to TVP with TG improves the overall texture of the protein mixture, making it a suitable meat alternative.

Analysis of the Spent Fuel Cooling Time for a Deep Geological Disposal (심지층 처분을 일한 사용후핵연료 냉각기간 분석)

  • Lee, Jong-Youl;Cho, Dong-Geun;Choi, Heui-Joo;Choi, Jong-Won;Lee, Yang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.65-72
    • /
    • 2008
  • The purpose of the HLW deep geological disposal is to isolate and to delay the radioactive material release to human beings and the environment for a long time so that the toxicity does not affect to the environment. The main requirements for the HLW repository design is to keep the buffer temperature below $100\;^{\circ}C$ in order to maintain its integrity. So the cooling time of spent fuels discharged from the nuclear power plant is the key consideration factors for efficiency and economic feasibility of the repository. The disposal tunnel/disposal hole spacing, the disposal area and thermal capacity required for the deep geological repository layout which satisfies the temperature requirement of the disposal system is analyzed to set the optimized spent fuels cooling time. To do this, based on the reference disposal concept, thermal stability analyses of the disposal system have been performed and the derived results have been compared by setting the spent fuels cooling time and the disposal tunnel/disposal hole spacing in various ways. From these results, desirable spent fuels cooling time in view of disposal area is derived. The results shows that the time reaching the maximum temperature within the design limit of the temperature in the disposal site is likely shortened as the cooling time of spent fuels becomes short. Also it seems that the temperature-rising and-dropping patterns in the disposal site are of smoothly varying form as the cooling time of spent fuels becomes long. In addition, it is revealed that a desirable cooling time of spent fuels is approximately 40-50 years when spent fuels are supposedly disposed in the deep geological disposal site with its structural scale under consideration in this study.

  • PDF

Enhanced High-Temperature Performance of LiNi0.6Co0.2Mn0.2O2 Positive Electrode Materials by the Addition of nano-Al2O3 during the Synthetic Process (LiNi0.6Co0.2Mn0.2O2 양극 활물질의 합성공정 중 나노크기 알루미나 추가에 의한 고온수명 개선)

  • Park, Ji Min;Kim, Daeun;Kim, Hae Bin;Bae, Joong Ho;Lee, Ye-Ji;Myoung, Jae In;Hwang, Eunkyoung;Yim, Taeeun;Song, Jun Ho;Yu, Ji-Sang;Ryu, Ji Heon
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.3
    • /
    • pp.80-86
    • /
    • 2016
  • High Ni content layered oxide materials for the positive electrode in lithium-ion batteries have high specific capacity. However, their poor electrochemical and thermal stability at elevated temperature restrict the practical use. A small amount of $Al_2O_3$ was added to the mixture of transition metal hydroxide and lithium hydroxide. The $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$ was simultaneously doped and coated with $Al_2O_3$ during heat-treatment. Electrochemical characteristics of modified $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$ were evaluated by the galvanostatic cycling and the LSTA(linear sweep thermmametry) at the constant voltage conditions. The nano-sized $Al_2O_3$ added materials show better cycle performance at elevated temperature than that of micro-sized $Al_2O_3$. As the added amount of nano-$Al_2O_3$ increased, the thermal stability of electrode also enhanced, but the use of 2.5 mol% Al showed the best high temperature performance.

Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air (실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가)

  • Baek, Sung-Ok;Moon, Young-Hun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.496-513
    • /
    • 2004
  • This study was carried out to evaluate the performance of sampling and analytical methodology used for the measurement of toxic volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis. Target analytes were 33 compounds including major aromatic compounds such as BTEX, and halogenated compounds. The methodology was investigated with a wide range of different adsorbents which are commercially available and have been frequently adopted for the VOC measurement. A total of 10 adsorbents were tested in this study: 6 carbon-based adsorbents such as Carbotrap, Carbopack B, Carbosieve S-III, Carboxen 1000, Carbotrap C, Activated Charcoal; and 4 polymer-based adsorbents including Tenax, Porapak Q, Chromosorb 102, and Chromosorb 106. The sampling performance was evaluated with respect to the sampling capacity of VOCs with single-adsorbent and multiple-adsorbents methods for standard samples and field samples. As a result, the best adsorbents for single-adsorbent method in the sampling of toxic organic compounds (including benzene, toluene, xylenes etc.) appeared to be Carbotrap, Carbopack B and Tenax TA. On the other hand, Chromosorb 102, Chromosorb 106 and Porapak Q were found to be unsuitable adsorbents for VOC measurement based on thermal desorption method. Multi-adsorbent packings were evaluated with 4 carbon-based adsorbents, which classified by 3 combination sets of double adsorbents and 2 combination sets of triple adsorbents. The results indicated that the most suitable combination for toixc VOC measurements is Carbotrap C with Carbotrap. Multi-sorbents tubes packed with a strong adsorbent such as Carbosieve S-III or Carboxen 1000 were found to be relatively unsuitable for several compounds, not only owing to the effect of migration of adsorbed compounds from weaker adsorbent to stronger adsorbent, but to hydrophobic nature of the adsorbents. Therefore, it should be addressed that selection of a proper adsorbent (or combination of multi sorbents) is extremely important to obtain reliable data for the concentrations of toxic VOCs in indoor and outdoor environments.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Removal of CO2 from Syngas(CO2 and H2) Using Nanoporous Na2CO3/Al2O3 Adsorbents (나노기공성 Na2CO3/Al2O3 흡착제를 이용한 합성가스(CO2, H2) 내 CO2 제거)

  • Bae, Jong-Soo;Park, Joo-Won;Kim, Jae-Ho;Lee, Jae-Goo;Kim, Younghun;Han, Choon
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.646-650
    • /
    • 2009
  • Hydrocarbon gases generated from the gasification of waste could be converted into $CO_2$ and $H_2$ using reforming catalysts and then $CO_2$ was selectively adsorbed and removed to obtain pure hydrogen. To optimize adsorption efficiency for $CO_2$ removal, $Na_2CO_3$ was supported on nanoporous alumina and the efficiency was compared with commercial alumina(Degussa). Nanoporous adsorbents formed more uniform pores and larger surface area compared to adsorbents using commercial alumina. The increase of $Na_2CO_3$ loading improved adsorption of $CO_2$. Finally, the highest adsorption capacity per unit mass of $Na_2CO_3$ could be achieved when the loading of $Na_2CO_3$ reached up to 20wt%. When the content of $Na_2CO_3$ increased above 20 wt%, it aggregated on the surface, and the pore volume was decreased. Used adsorbents could be recycled by the thermal treatment.

Physical and Thermodynamic Properties of Imidazolium Ionic Liquids (이미다졸계 이온성 액체의 물성)

  • Oh, Sooyeoun;Kang, Jeong Won;Park, Byung Heung;Kim, Ki-Sub
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.708-712
    • /
    • 2012
  • Ionic liquids (ILs) existing as liquid state at room temperature are composed of a immense heterocyclic cation and inorganic anion which is smaller than cation's size. Thus, the species of cation and anion as well as the length of alkyl group on the cation have influence on their physical properties. Their outstanding properties such as non-volatility, thermal stability and wide range of electrochemical stability make these materials excellent candidates for green solvent which can substitute the conventional organic solvents. In this study, ILs based on imidazolium cation have been synthesized such as 1-butyl-3-methylimidazolium bromide ([BMIM][Br]), 1-butyl-3-methylimidazolium chloride ([BMIM] [Cl]), 1-butyl-3-methylimidazolium iodide ([BMIM][I]), and 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM][$BF_4$]). The density, viscosity, refractive index, heat capacity and ionic conductivity of [BMIM][Br], [BMIM][I], and [BMIM] [$BF_4$] were measured over range of temperature of 293.2 to 323.2 K. The density and refractive index values of [BMIM][I] were the highest among three ILs and the viscosity values of [BMIM][Br] were the highest among three ILs. The heat capacities [BMIM][$BF_4$] were higher than those of [BMIM][Br]. The ionic conductivities of [BMIM][$BF_4$] were higher than those of [BMIM][I].

Optimization of ${\beta}$-Glucanase-assisted Extraction of Starch from Domestic Waxy Barley and Its Physicochemical Properties (${\beta}$-Glucanase를 이용한 국내산 찰보리 전분 추출공정의 최적화 및 추출 전분의 주요 이화학적 특성에 관한 연구)

  • Jeong, Yong-Seon;Bae, Jae-Seok;Kim, Jeong-Won;Lee, Eui-Seok;Lee, Ki-Teak;Lee, Mi-Ja;Hong, Soon-Taek
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.23 no.6
    • /
    • pp.789-798
    • /
    • 2013
  • In the present study, optimization on ${\beta}$-glucanase-assisted extraction was made in order to isolate waxy barley starch from domestic cultivar using the D-optimal design suitable for response surface methodology (RSM). The results demonstrated that the amount of enzyme was found to be a major influencing factor on the extraction yield, which was substantially increased by increasing the amount of enzyme. It was also influenced by the reaction time and amount of water addition; however, the two factors were less influential than the amount of enzyme. The optimized condition by RSM for the reaction time was found to be 2.63 hours and amount of enzyme 1.7%, and amount of water addition 4.38 times the weight of raw material. With the enzyme treatment, the starch content in residues (R), particularly in R1 and R5, was reduced considerably, resulting in an increase in the extraction yield and therefore primarily and effectively releasing B-type starch small granule confirmed by scanning electronic microscopy. In addition, the study determined the physicochemical properties of isolated waxy starch (i.e., purity, water adsorption capacity, thermal properties, rheology and starch morphology) and compared them with those from the enzyme-not treated sample. It was found that they were almost similar to each other, except for the purity of starch, which was lower in the enzyme-treated sample than in the enzyme-not treated one.

A Study on Load Current and Temperature to Expect Lifetime of High-Power Cables (고전력 케이블의 잔여 수명 예측을 위한 부하 전류 및 온도 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.199-203
    • /
    • 2015
  • With the development of industry these days, the demand for electric power increases and the larger capacity for power transfer is required. The scales of facilities should become larger; and the relative systems are required to operate with a higher degree of reliability. Therefore, stabilization of electric power systems is an important issue. The high degree of reliability required in the process of production and supply of electric power is an essential part of industrial society. Accident such as blackouts causes a hugh amount of economic losses to the high-tech industrial society dependent upon electric power. This paper is about the basic study of the relations between the load current and lifetime of power cables in operation. In order to do the research, we installed a current transformer and an equipment for measuring temperature at the 6.6. kV cables in operation. The two equipments have been installed on the cable systems in operation for the last 20 years. Since the insulation resistance of most of the cables showed the value larger than the threshold, it was not easy to tell the remaining lifetime of cables. The load current of the cables was almost constant. The surrunding temperature was $15{\sim}25^{\circ}C$, little variation of temperature values.

Prediction of the Tritium Behavior in Very High Temperature Gas Cooled Reactor Using TRITGO (TRITGO 코드를 이용한 초고온가스로 (VHTR) 삼중 수소 거동 예측)

  • Park, Jong-Hwa;Park, Ik-Kyu;Lee, Won-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.3
    • /
    • pp.113-120
    • /
    • 2008
  • In this study, The TRITGO code was introduced, which can predict the amount of tritium production, it's transport, removal, distribution and the level of contamination for the produced hydrogen by the tritium on the VHTR (very high temperature gas cooled reactor). The TRITGO code was improved so that the permeation to the IS Iodine Sulfide) loop for producing the hydrogen can be simulated. The contamination level of the produced hydrogen by the tritium was predicted by the improved code for the VHTR with 600MW thermal power. The contamination level for the produced hydrogen by tritium was predicted as 0.055 Bq/$H_2-g$. This level is three order of lower than the regulation value of 56 Bq/$H_2-g$ from Japan. From this study, the following results were obtained. it is important that the fuel coating (SiC layer) should be kept intact to prevent the tritium from releasing. Also it is necessary that the level of impurity such as 3He and Li in the helium coolant and the reflector consisting of the graphite should be kept as low as possible. It was found that the capacity of the purification system for filtering the impurities directly from the coolant will be the important design parameter.