• Title/Summary/Keyword: Therapy Room

Search Result 325, Processing Time 0.035 seconds

Effect of NaCl on the Stability of Oncolytic Vaccinia Virus (항암 백시니아 바이러스의 안전성에 대한 염화나트륨의 효과)

  • Kim, Seong-Geun;Ran, Gui Shao;Kwon, Hyuk-Chan;Hwang, Tae-Ho
    • Journal of Life Science
    • /
    • v.26 no.1
    • /
    • pp.23-33
    • /
    • 2016
  • Pexa-Vec (JX-594) is a specific cancer-targeted oncolytic and immunotherapeutic vaccinia virus. The purpose of this study was to develop methods to maximize the stability of Pexa-Vec. In short-term instability testing, viral activity was rapidly decreased both at 4℃ and at room temperature (RT), but it was completely restored after sonication followed by vortex. Long-term stability testing of Pexa-Vec in the following liquid formulations was performed: (A) 30 mM Tris/pH 7.6, (B) 30 mM Tris/pH 8.6, (C) 30 mM Tris/pH 7.6, 150 mM NaCl, 15% sucrose, (D) 30 mM Tris/pH 7.6, 15% sucrose, and (E) 30 mM Tris/pH 8.6, 15% sucrose. Viral activity decreased less than 2 log10 at 4℃, and RT was observed in 3 days in B, while viral activity was not decreased even after 4–8 weeks at 4℃ and at 1 week in RT in A, suggesting that neutral pH may be essential to maintain virus stability. The addition of 15% sucrose into A (D) significantly increased viral stability at −20℃, 4℃, or RT, and it was also observed at pH 8.6 (E). The addition of 150 mM NaCl into D (C) significantly increased viral stability in addition to the sucrose effect at 4℃ or RT. Accordingly, the viral activity in formulation C was maintained for 1.5 years at 4℃, and for 1-2 weeks in RT. In conclusion, we propose that formulation C can provide the most adequate condition for the proper storage of vaccinia oncolytic virus.

Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom (인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Purpose: The aim of this study is to compare patient's body posture and its position at the time of simulation with one at the treatment room using On-board Imaging (OBI) and CT (CBCT). The detected offsets are compared with position errors of Rando Phantom that are practically applied. After that, Rando Phantom's position is selected by moving couch based on detected deviations. In addition, the errors between real measured values of Rando Phantom position and theoretical ones is compared. And we will evaluate target position's accuracy of KV X-ray imaging's 2D and CBCT's 3D one. Materials and Methods: Using the Rando Phantom (Alderson Research Laboratories Inc. Stanford. CT, USA) which simulated human body's internal structure, we will set up Rando Phantom on the treatment couch after implementing simulation and RTP according to the same ways as the real radioactive treatment. We tested Rando Phantom that are assumed to have accurate position with different 3 methods. We measured setup errors on the axis of X, Y and Z, and got mean standard deviation errors by repeating tests 10 times on each tests. Results: The difference between mean detection error and standard deviation are as follows; lateral 0.4+/-0.3 mm, longitudinal 0.6+/-0.5 mm, vertical 0.4+/-0.2 mm which all within 0~10 mm. The couch shift variable after positioning that are comparable to residual errors are 0.3+/-0.1, 0.5+/-0.1, and 0.3+/-0.1 mm. The mean detection errors by longitudinal shift between 20~40 mm are 0.4+/-0.3 in lateral, 0.6+/-0.5 in longitudinal, 0.5+/-0.3 in vertical direction. The detection errors are all within range of 0.3~0.5 mm. Residual errors are within 0.2~0.5 mm. Each values are mean values based on 3 tests. Conclusion: Phantom is based on treatment couch shift and error within the average 5mm can be gained by the diminution detected by image registration based on OBI and CBCT. Therefore, the selection of target position which depends on OBI and CBCT could be considered as useful.

  • PDF

Radiotherapy Incidents Analysis Based on ROSIS: Tendency and Frequency (ROSIS 자료 기반 방사선 사고 사례 분석 : 경향과 빈도)

  • Koo, Jihye;Yoon, MyongGeun;Chung, Won Kuu;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.298-303
    • /
    • 2014
  • In this study, we examine the trends and types of incidents frequently occur during radiation therapy by using the data from the radiation oncology safety information system (ROSIS), according to discovery method explores the development direction of future research accident cause factor control method. This study was carried out analysis of incident data in ROSIS nearly 1163 cases in last 11 years from 2003 to 2013. We categorized into treatment methods, found the time, discoverer of occupations and finding ways to analyze the data. Then, we calculate the percentage and the classification for each item. About 1163 cases of incident cases including the near miss cases, external radiation therapy, brachytherapy and other were 97%, 2% and 1%. In the case was improperly planned dose delivery was 44% (497 cases) which 429 cases (86%) was found before 3 fractions and 13 cases were found after 11 fractions. The investigation was found to be distributed in various a found times. Approximately 42% of found time was during treatment and 29% of patients were found the problem during inspection chart. Occupation to discover the most radiation accidents was the radiation therapist (53%) who works in treatment room. Among 1163 incidence cases, 24% cases were found the accident before the treatment, therefore most of accident were found after of during the treatment (70%, 813 cases). This trend is acquired through ROSIS analysis, is expected to be not significantly different in the case of Korea, so it is necessary more diverse and systematic research for the prevention and early detection by using the ROSIS data.

A Need Assessment on Establishment of Oriental Health Promotion Center (한방건강증진센터 설립에 대한 인식 및 요구조사)

  • Lee, Hyang-Yeon;Kim, Kwuy-Bun;Cho, Kyoul-Ja;Shin, Hye-Sook;Kim, Kwang-Joo;Moon, Heui-Ja;Park, Shin-Ae;Kim, Yoon-Hee;Kang, Hyun-Sook
    • Journal of East-West Nursing Research
    • /
    • v.5 no.1
    • /
    • pp.90-101
    • /
    • 2000
  • The study attempts to examine the degree of cognition and demand on health promotion center of oriental nursing. It puts unique nursing intervention using traditional health promotion connected with oriental medicine to practical use for residents' health promotion and prevention of disease. With the study design of cross-sectional descriptive study, 516 residents who live in 26 Dongs, Dongdaemoon-gu were selected. The tool of study consists of 30 questions which the study team made for the degree of cognition and demand on health promotion center of oriental nursing. Cronbach's $\alpha$ in the degree of cognition was .8028. Collection of research data had been done from October 1 to October 30, 1999 with help of Dongdaemoon-gu office after pretest from 20 residents. Collected data were analyzed into the number and percentage in the characteristic of a subject and connected with demand on the establishment of center, the mean and the standard deviation in the degree of cognition and F-tests in the difference of the degree of cognition by characteristics. The results were as follow; 1) The characteristic of subject of this study was male 50.6%, and average age was 38.5 years old and 30-39 years old occupied the highest percentage with 31.6%. The married were 71.8%, over high school graduates was 85.6%, monthly income from 500 thousand won to 2 million won was 86.1%. 50.8% was the type living with parents, children and sibling. 2) When they were sick, the institution which residents used at first was a pharmacy(69.2%) and hospital(27.5%), but oriental medicine hospital was just 1.4%. As for subjective health condition, 82.5% answered over average, and 28.7% answered that they had chronic illness such as arthritis, chronic digestion problem, hypertension and so on. As for information collection on health, mass communication(34.9%) and medically concerned people(28.1%) occupied relatively high rate. Free health diagnosis system(36.8%) and establishment of health promotion center(31.5%) among welfare programs that residents want to enjoy were high ranked. The rate using a special institution for health was 17.8%, and among these institutions, the rate using aerobic exercises, health center(7.0%) and steamed room(5.4%) was high. Besides, other institutions such as breathing at the abdomen, finger-pressure therapy, meridian massage, foot massage, and so on were being used. 3) As the average of the degree of cognition on health promotion center of oriental medicine was 2.92, the degree of cognition was medium. The description, "health promotion center of oriental medicine is necessary for health keeping of healthy people, including people who have a problem in health" showed the highest degree of cognition(3.04, ${\pm}0.64$). 4) As for the intention on using health promotion center of oriental nursing, 61.4% said "yes", "no" was just 1.4%. The services that people relatively high wanted to be served from the center were measures reducing stress(68.0%) (relaxation therapy, meditation, breathing at the abdomen and so on), acupuncture(66.5%), finger-pressure(61.6%), moxibustion(57.6%), meridian massage(44.2%), postpartum care(40.3%) and so on. 5) As for the degree of cognition on the establishment of health promotion center of oriental nursing by characteristics of subject, there was significant difference(F=4.03, p=.046) between male(3.01) and female(2.91). But there was no significant difference by age, marital status, level of educational achievement and monthly income. As the above result, cognition on the establishment of health promotion center of oriental nursing was relatively low because people were not familiar with about the health promotion center of oriental nursing yet. However once the center will be established, the degree of demand on the center will be relatively high. So positive advertisement will be necessary, and the management of useful programs will be also required in order to make people recognize the advantage when they actually will use the center. On the other hand, as the subject of the study consists of many young people of below 30, the health problem came to be low. And in the case of sampling, the study using random sampling that can represent population will be required.

  • PDF

Development of Contents for the Activities of Daily Living Training for Life Care - Korean Version (라이프케어를 위한 한국형 일상생활활동훈련치료 콘텐츠 개발)

  • Lee, Chun-Yeop;Park, Young-Ju
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.529-538
    • /
    • 2020
  • This study aims to develop of contents for the activities of daily living training - Korean version that reflexes the domestic situation and can be applied to clinical practice. For contents development, a Delphi survey was conducted with 13 experts. In the first Delphi survey, 133 items of activities of daily living training are derived based on previous studies, and then the extracted items are asked to group of experts, and the derived items are answered for actual domestic clinical application. In the second survey, 118 items were added by excluding items with a low content validity ratio (CVR) including the results of the first survey, and adding items that can be derived from other opinions. In the 3rd survey, while presenting the 2nd Delphi survey items as they are, it provides an opportunity to change their opinions by presenting their 2nd response and the 2nd average score of other expert panels, and adding appropriateness and importance together. The data were analyzed to obtain the mean, standard deviation, interquartile range, CVR, convergence, and consensus. Finally, a total of 69 items were selected and 49 items were excluded so that 105 items for CVR 0.54 or higher, 111 items for convergence degree 0.50 or lower, and 70 items for continuity degree 0.75 or higher. Sexual activity, care of others, care of pets, and child rearing are difficult to apply socially and culturally, driving and community mobility cannot be performed within the clinical room, and home establishment and management may have different roles depending on gender, and religious spiritual activities and expression are so personal. For these reasons, these items were found to have low importance or suitability. This study can be usefully used as an indicator on the activities of daily living training - Korean version in clinic or community setting.

Initial Analysis of the Underground Air Among Jeju Lava Forest(Sumgol) and its Healing Effect on the Human Body (제주 현무암 '숲' 지하 공기(숨골: Sumgol)의 분석과 인체에 미치는 치유 효과)

  • Sin, SBangsik;Kim, Hyek Nyeon;Lee, Deok Hee;Kim, Tae Seung;Kim, Yong Hwan;Kang, Chang Hee;Song, Kyu Jin;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.11 no.1
    • /
    • pp.18-30
    • /
    • 2022
  • Background: It was to develop an air purification system (APS) using an underground air purification layer to verify the effect of basalt forest's underground air (sumgol) on a volcanic Jeju. Finally, it is necessary to analyze these purified air components and their usefulness to the human body in an air experience center. Purpose: It was to collect basalt forest air, analyze its composition, and explore its effect on the human body. Methods: We APS devices installed at four points in the Papaville area of Jeju. The air discharged from the APS was collected and analyzed the recycling components. An installed experience room filled with negative ions is about 5,000 ions/m3. After allowing the participants to stay for 60 to 120 minutes, we investigated the state of blood vessels. Results: In the analysis of the underground air, the O2 concentration was 21.18%, which was higher than the average oxygen concentration of 20.94% in the atmosphere. However, Formaldehyde was not detected, and the CO2 was 419 ppm, which was lower than that of indoor air. The PM2.5 concentration was less than 24 ㎍/m3 and detected anions over 5.000 /m3. The experiencer's vascular states improved, and the increase in pulse rate and stress relief were high. Conclusions: The valuable ingredients identified by analyzing the air were precious for natural healing. The experience results showed that it effectively improved the pulse rate, blood vessels, and stress. These conditions may be highly beneficial as a new area for expanding the basalt lava forest in the Jeju area into the natural healing and wellness industry.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

A Case of Rapidly Developed Obesity Hypoventilation Syndrome in a Patient with Kyphoscoliosis (척추후측만증 환자에서 급속히 진행된 비만성 저환기 증후군 1례)

  • Kim, Min Young;Jeong, Jee Sun;Jang, Yu Na;Go, Se-eun;Lee, Sang Haak;Moon, Hwa Sik;Kang, Hyeon Hui
    • Sleep Medicine and Psychophysiology
    • /
    • v.22 no.1
    • /
    • pp.30-34
    • /
    • 2015
  • Obesity hypoventilation syndrome (OHS) is characterized by severe obesity, excessive daytime sleepiness, hypoxemia and hypercapnea. Because OHS mimics pulmonary hypertension or cor pulmonale, clinicians should recognize and treat this syndrome appropriately. A 58-year-old female visited the emergency room because of dyspnea. She was obese and had kyphoscoliosis. The patient also experienced snoring, recurrent choking during sleep and daytime hypersomnolence which worsened after gaining weight in the recent year. The arterial blood gas analysis showed she experienced hypoxemia and hypercapnea not only during nighttime but also daytime. We suspected OHS and the patient underwent polysomnography to confirm whether obstructive sleep apnea was present. During the polysomnography test, sleep obstructive apnea was observed and apnea-hypopnea index was 9.2/hr. The patient was treated with bilevel positive airway pressure therapy (BiPAP). After BiPAP for 4 days, hypoxemia and hypercapnia were resolved and she is currently well without BiPAP. We report a case successfully treated with clinical improvement by presuming OHS early in a patient who had typical OHS symptoms, even while having other conditions which could cause hypoventilation.