• Title/Summary/Keyword: Therapeutic computer

Search Result 106, Processing Time 0.026 seconds

A Verification for Multiple Arc Stereotaxic Radiotherapy (정위 다방향 방사선조사의 선량분포를 위한 증명)

  • Yoon, Sei-Chul;Jang, Hong-Seok;Kim, In-Ah;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.111-114
    • /
    • 1990
  • External stereotaxic irradiation of intracranial lesions has recently gained its interest in the fields of not only radiation oncolgy but also neurosurgery. Its main goal is to deliver large doses to a relatively small target volume. Authors present methods of the stereotaxic radiosurgical irradiation using 6 MV linear accelerator (Nelac-6) and isodose distribution by therapeutic computer (Therac 2000). We attempt to demonstrate the dose distribution on verification films.

  • PDF

A Study on the Realities and Preventive Countermeasures of Child Abuse Committed by Biological Parents by information analysis.

  • Ryu, Chae-Hyoung;Yoon, Hyun-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.5
    • /
    • pp.171-177
    • /
    • 2019
  • In this paper, we analyze the current phenomenon of child abuse crimes based on the information gathered by the National Child Protection Agency. The purpose of this paper is to diagnose the seriousness of child abuse by biological parents based on the analyzed information and propose measures against it. Comprehensive and integrated measures are needed for child abuse committed by biological parents due to abuse concealment, continuity of damage, and inactive national intervention by considering punishment on attackers through national intervention, fundamental in-depth psychological counseling, therapeutic care, promoting recovery of victims, and ultimately continuous and regular management and monitoring as a long-terms measure. To do so, developing customized and individual educational programs and make them obligations can be first presented to identify child abuse in advance and build up preventive systems based on the principle of family preservation. In addition, problems should be addressed at a fundamental level by performing various and active therapeutic treatments such as psychological treatment, mental treatment, or drug treatment gradually and through phases for biological parents who commit child abuse and contributing to recovering the relationship. Furthermore, proper protection and treatment service should be provided to children victimized by abuse by extending professional children care facilities and adopting the professional family commission system as measures by separating family.

Generative Interactive Psychotherapy Expert (GIPE) Bot

  • Ayesheh Ahrari Khalaf;Aisha Hassan Abdalla Hashim;Akeem Olowolayemo;Rashidah Funke Olanrewaju
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2023
  • One of the objectives and aspirations of scientists and engineers ever since the development of computers has been to interact naturally with machines. Hence features of artificial intelligence (AI) like natural language processing and natural language generation were developed. The field of AI that is thought to be expanding the fastest is interactive conversational systems. Numerous businesses have created various Virtual Personal Assistants (VPAs) using these technologies, including Apple's Siri, Amazon's Alexa, and Google Assistant, among others. Even though many chatbots have been introduced through the years to diagnose or treat psychological disorders, we are yet to have a user-friendly chatbot available. A smart generative cognitive behavioral therapy with spoken dialogue systems support was then developed using a model Persona Perception (P2) bot with Generative Pre-trained Transformer-2 (GPT-2). The model was then implemented using modern technologies in VPAs like voice recognition, Natural Language Understanding (NLU), and text-to-speech. This system is a magnificent device to help with voice-based systems because it can have therapeutic discussions with the users utilizing text and vocal interactive user experience.

The Evaluation of Multiplane-Parallel Chamber Using Crystal Plate as Ionization Medium for Therapeutic Radiation Beams

  • Young W. Vahc;Park, Kyung R.;Kim, Sookil;Chul W. Joh;Kim, Tae H.
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 1998
  • There has been necessity of an air free ionization chamber using the gold-crystal-aluminium plates, henceforth called the crystal chamber. The crystal chamber formed of parallel plates is very small in size and has more response for absorbed dose of therapeutic radiation beams. The gold plate on the crystal facing the photon and electron beam acts as an intensifier of signals and crystal plate as an ionization medium respectively. Both the copper guard ring and the aluminum collecting electrode are connected to an electrometer. Using high energy photon (6, 15 MV) and electron (9, 12, 15, 18 MeV) beams, the responses of the crystal chamber are evaluated against a PTW Farmer-type chamber at a field size of 10${\times}$10cm$^2$ and 100 cm SSD. The responses of crystal chamber for therapeutic radiation electron and photon beams are greater in magnitude by several order than Farmer. The crystal chamber has good linearity without correction factor C$\_$t,p/ with respect to the signals, a reading reproduction with good accuracy and precision less than 0.5%, and has other useful functions in measuring radiation beams.

  • PDF

A Study on WWW-based Digital Pulse Database System (인터넷을 이용한 디지털 맥진 서버시스템 구축)

  • Seo, H.W.;Lee, J.Y.;Kim, J.H.;Hwang, S.C.;Lee, M.H.;Lee, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3241-3242
    • /
    • 2000
  • Recent progress in the medical informatics enables us to use the medical information regardless on the time or place limit, to make a diagnostic and therapeutic plan, according to increasing need about health of general population. There are many database oriented sites on the web, which provide medical common senses, hospital information, and medical counselling on the web. But there are few oriental pulse database on the web. The purpose of this study is to develope the Clinical Oriental Pulse Database Management System over the WWW.

  • PDF

Design and Implementation of VR-ADHD Digital Therapy Using VR Games

  • Dae-Won Park;Han-Byul Kang;Sang-Hyun Lee
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.1
    • /
    • pp.332-336
    • /
    • 2023
  • In this paper, we design and implement an ADHD diagnostic rating scale algorithm and virtual reality- based digital treatment by combining virtual reality technology that enables multiple access based on specialized medical data. The VR ADHD digital treatment to be implemented is intended to be applied directly to diagnosis and treatment of child/adolescent ADHD by applying various psychiatric treatment technologies. In order to evaluate the usability of the digital therapeutic agent developed in this paper, an expert group consisting of 2 males and 12 females "targeted counseling psychology majors at the Asian Dementia Center once a day for 3 weeks, ADHD VR-based digital therapeutics for children Experienced and usability evaluation conducted. As a final result of this thesis, it was possible to develop attentional concentration ability, working memory improvement ability, and impulsive control ability in four games of digital therapy, and it was possible to confirm significant results that can be expected to have ADHD therapeutic effects.

NutriSonic web expert system for meal management and nutrition counseling with nutrient time-series analysis, e-food exchange and easy data transition

  • Hong, Soon-Myung;Cho, Jee-Ye;Lee, Jin-Hee;Kim, Gon;Kim, Min-Chan
    • Nutrition Research and Practice
    • /
    • v.2 no.2
    • /
    • pp.121-129
    • /
    • 2008
  • This study was conducted to develop the NutriSonic Web Expert System for Meal Management and Nutrition Counseling with Analysis of User's Nutritive Changes of selected days and food exchange information with easy data transition. This program manipulates a food, menu and meal and search database that has been developed. Also, the system provides a function to check the user's nutritive change of selected days. Users can select a recommended general and therapeutic menu using this system. NutriSonic can analyze nutrients and e-food exchange ("e" means the food exchange data base calculated by a computer program) in menus and meals. The expert can insert and store a meal database and generate the synthetic information of age, sex and therapeutic purpose of disease. With investigation and analysis of the user's needs, the meal planning program on the internet has been continuously developed. Users are able to follow up their nutritive changes with nutrient information and ratio of 3 major energy nutrients. Also, users can download another data format like Excel files (.xls) for analysis and verify their nutrient time-series analysis. The results of analysis are presented quickly and accurately. Therefore it can be used by not only usual people, but also by dietitians and nutritionists who take charge of making a menu and experts in the field of food and nutrition. It is expected that the NutriSonic Web Expert System can be useful for nutrition education, nutrition counseling and expert meal management.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Treatment Planning Software for High Dose Rate Remote Afterloading Brachytherapy of Uterine Cervical Cancer (Personal computer를 이용한 자궁경부암의 고선량을 강내치료 계획)

  • Huh, Seung-Jae;Kang, Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.183-186
    • /
    • 1986
  • In brachytherapy of uterine cervical cancer using the high dose rate remote afterloading system, it is of prime importance to determine the position of the radiation sources and to estimate the irradiation time. However, calculation with manual method is so time consuming and laborious, that authors designed a software as an aid to intracavitary radiotherapy Planning using the personal computer to obtain the precision of treatment without being too complicated for routine use. Optimal source arrangement in combination with dose rate at each specific points and irradiation time can be easily determined using this software in several minutes.

  • PDF

A Computer Vision Approach for Identifying Acupuncture Points on the Face and Hand Using the MediaPipe Framework (MediaPipe Framework를 이용한 얼굴과 손의 경혈 판별을 위한 Computer Vision 접근법)

  • Hadi S. Malekroodi;Myunggi Yi;Byeong-il Lee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.563-565
    • /
    • 2023
  • Acupuncture and acupressure apply needles or pressure to anatomical points for therapeutic benefit. The over 350 mapped acupuncture points in the human body can each treat various conditions, but anatomical variations make precisely locating these acupoints difficult. We propose a computer vision technique using the real-time hand and face tracking capabilities of the MediaPipe framework to identify acupoint locations. Our model detects anatomical facial and hand landmarks, and then maps these to corresponding acupoint regions. In summary, our proposed model facilitates precise acupoint localization for self-treatment and enhances practitioners' abilities to deliver targeted acupuncture and acupressure therapies.