• Title/Summary/Keyword: Therapeutic I-131 capsule

Search Result 2, Processing Time 0.016 seconds

Safety Simulation of Therapeutic I-131 Capsule Using GEANT4 (GEANT4를 이용한 치료용 I-131 캡슐의 안정성 시뮬레이션)

  • Jeong, Yeong-Hwan;Kim, Byung-Cheol;Sim, Cheol-Min;Seo, Han-Kyung;Gwon, Yong-Ju;Han, Dong-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.57-61
    • /
    • 2014
  • Purpose Iodine (I-131) is one of the most widely used radioactive isotopes for therapeutic in the field of nuclear medicine. Therapeutic I-131 capsule is made out of lead to shield high energy radiation. Accurate dosimetry is necessarily required to perform safe and effective work for relative workers. The Monte Carlo method is known as a method to predict the absorbed dose distribution most accurately in radiation therapy and many researchers constantly attempt to apply this method to the dose calculation of radiotherapy recently. This paper aims to calculate distance dependent and activity dependent therapeutic I-131 capsule using GEANT4. Materials and Methods Therapeutic capsules was implemented on the basis of the design drawings. The simulated dose was determined by generating of gamma rays of energy to more than 364 keV. The simulated dose from the capsule at the distance of 10 cm and 100 cm was measured and calculated in the model of water phantom. The simulated dose were separately calculated for each position of each detector. Results According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of therapeutic I-131 capsule should not exceed 2.0 mSv/h and 0.02 mSv/h, respectively. The simulated doses turned out to be less than the limit, satisfying the domestic regulation. Conclusion These simulation results may serve as useful data in the prediction of hands dose absorbed by I-131 capsule handling. GEANT4 is considered that it will be effectively used in order to check the radiation dose.

  • PDF

A Summary of Radiation Accidents in Atomic Energy Activities of Korea (우리나라의 원자력 연구 개발에 수반된 방사선 사고)

  • 이현덕;하정우
    • Nuclear Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.97-106
    • /
    • 1970
  • Radiation accidents which occured in the A.E.R.I. during last ten years are described (table 1). It seemed to the authors that some of these accidents were considered to be hazardous to man body and associated installations. This report deals with the following four major accidents involving body contamination incidents that our health physicists have been experienced. 1. Over-exposures (up to 130 rem) to the total body due to the mismanipulation in the Cobalt-60 gamma irradiation facility. 2. Floor surface contamination (up to 13 mrad/hr) and its spread out due to the mishandling of radioiodine contained in the bottle. 3. Body surface contamination and 0.36 uCi radioactivity accumulated in the thyroid gland of a worker due to the inhalation of gaseous iodine-131. 4. A void capsule due to the leakage out of the radium therapeutic source (3mg\ulcorner) These accidents were treated by definitely prompt action to protect the workers and associated installations from any radiation hazards and every possible efforts were made to confine the spread of radioactive contamination as small area as possible by means of elaborate decontamination work and monitoring.

  • PDF