• Title/Summary/Keyword: Thenoyltrifluoroacetone (TTA)

Search Result 12, Processing Time 0.018 seconds

Synergistic extraction of lanthanoids(III) with thenoyltrifluoroacetone and aromatic carboxylic acids and the hydration of the extracted species

  • Ishiwata, E.;Kimura, T.;Kato, Y.;Hasegawa, Y.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.499-503
    • /
    • 1995
  • In order to study how and why the stabilities of lanthanoid(III) complexes in solutions vary across the series, the formation constants of the adducts of tris(2-thenoyltrifluoroacetonato)lanthanoids(III) with seven carboxylic acids in chloroform have been determined by solvent extraction technique at 298K. The formation constants with carboxylic acids generally decrease with increasing the atomic number, but in the middle of the series, they change only slightly. Such trends have been interpreted as related to a change of the coordination number in the middle of the series. It has been attempted to determine the number of water molecules coordinated to the adducts as well as $Eu(TTA)_3$ in chloroform by measuring the fluorescence life time of europium(III), to ensure the assignment of the coordination number.

  • PDF

Electrodeposition of some Alpha-Emitting Nuclides and its Isotope Determination by Alpha Spectrometry (몇가지 알파입자 방출 핵종의 전해석출 및 알파 스펙트럼 측정에 의한 그의 동위원소 정량)

  • Key-Suck Jung;In-Suck Suh
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.279-286
    • /
    • 1983
  • An apparatus was made for the electrodeposition of alpha emitting actinide nuclides, $^{207}Bi$ and $^{210}Po$. The electrodeposition was made on a polished stainless steel plate cathode. The anode was made of platinum wire and to stir the solution. With the ammonium chloride as electrolyte initial pH = 4, chloride concentration = 0.6M and solution volume = 15ml, a current of 1.5 ampere(current density = 0.59A/$cm^2$) was flowed for 100 minutes for the quantitative recovery of electrodeposition and on average recovery of 98.3% was obtained within ${\pm}$0.7% uncertainty. Alpha spectrometry of the electrodeposited sample showed alpha peaks from $^{210}Po, ^{234}U$ and $^{239}Pu$ having energy resolution (FWHM) of 18.3, 21.8 and 36.0 keV respectively. The electrodeposition and alpha spectrometry for a natural uranium sample of domestic origin gave $^{238}U : ^{234}U = 1 : 6.1{\times}10^{-5}$ and for a neutron-irradiated uranium sample did $^{238}U : ^{239}Pu : ^{241}Am = 100 : 0.0263 : 5.20{times}10^{-5}$. The result of $^{238}U$ determination in the irradiated sample by electrodeposition-alpha spectrometry was in accord within ${\pm}1.6%$ of relative error with the results of solid fluorimetry and mass spectrometry. For $^{239}Pu$ the result of electrodeposition-alpha spectrometry was in accord within ${\pm}$4.0% of relative error with the results of anion exchange separation and the thenoyltrifluoroacetone(TTA) extraction both followed by alpha spectrometries.

  • PDF