• Title/Summary/Keyword: The small squid

검색결과 69건 처리시간 0.025초

오징어채낚기용 은백색 유인체 개발과 어획성능 (Development of the silver-white decoy for squid automatic jigging machine and fishing performance)

  • 안영일;장웅정
    • 수산해양기술연구
    • /
    • 제49권3호
    • /
    • pp.208-217
    • /
    • 2013
  • Decoys for automatic jigging machines, the body part of a squid hook, have been developed in small and existing sizes in consideration of squid food, color blindness, and retinomotor responses and in utilization of pearl pigment, PP of high transparency, and combined mixture. In comparison of the developed silver-white decoy and existing decoys, the optical characteristics were examined, and the fishing performance of small size silver-white squid hooks was assessed in application of 4 fishing boats with the squid automatic jigging machine and metal halide fishing lamp in July, 2012. The luminances of the three squid hook colors-green, dark green and silver-white-increased as the intensity of illumination increased. Among these, the increase of silver-white was particularly distinguished. As to the average contrast of squid hooks, that of silver-white was 10.33, which was the highest, and then green 1.86 and dark green -0.10 in the order. As to the fishing performance of the silver-white hook, that of the 202 Geumyeong-ho and 101Yongjin-ho which caught squids were similar to that of the existing green hook and was relatively low in the case of the Dongbu-ho. However, that of the Haengbok-ho which caught relatively small squids whose average length was 19.9cm and installed silver-white hook in all automatic jigging machines was significantly excellent. In order to enhance the fishing performance of small size silver-white hooks, therefore, it would be effective to install in every automatic jigging machines of fishing boat and to start fishing before July by which small squids are caught.

오징어 먹즙 첨가에 따른 저염 오징어 젓갈의 비휘발성 유기산 변화 (The Changes of Non-Volatile Organic Acids in Low Salt Fermented Squid Affected by Adding to Squid Ink)

  • 오성천;조정순
    • 한국응용과학기술학회지
    • /
    • 제20권1호
    • /
    • pp.64-71
    • /
    • 2003
  • Squid ink was added to the low salt fermented squid by 4% of concentration and ripened at 10$^{\cric}C$ for 6 weeks and at 20$^{\cric}C$ for 28 days. The effect of the squid ink on the non-volatile organic acids of low salt fermented squid were investigated. The results are as follows; The non-volatile organic acid in the salt fermented squid without addition of the squid ink was examined and the result showed that lactic and acetic acids were the major organic acids even if very small amount of citric and oxalic acids were detected. In the squid ink added to the low salt fermented squid, total quantity of non-volatile organic acid in the latter part of the ripening was lower than no treatment groups.

High-$T_c$ SQUID Application for Roll to Roll Metallic Contaminant Detector

  • Tanaka, S.;Kitamura, Y.;Uchida, Y.;Hatsukade, Y.;Ohtani, T.;Suzuki, S.
    • Progress in Superconductivity
    • /
    • 제14권2호
    • /
    • pp.82-86
    • /
    • 2012
  • A sensitive eight-channel high-Tc Superconducting Interference Device (SQUID) detection system for magnetic contaminant in a lithium ion battery anode was developed. Finding ultra-small metallic foreign matter is an important issue for a manufacturer because metallic contaminants carry the risk of an internal short. When contamination occurs, the manufacturer of the product suffers a great loss from recalling the tainted product. Metallic particles with outer dimensions smaller than 100 microns cannot be detected using a conventional X-ray imaging system. Therefore, a highly sensitive detection system for small foreign matter is required. We have already developed a detection system based on a single-channel SQUID gradiometer and horizontal magnetization. For practical use, the detection width of the system should be increased to at least 65 mm by employing multiple sensors. In this paper, we present an 8-ch high-Tc SQUID roll-to-roll system for inspecting a lithium-ion battery anode with a width of 65 mm. A special microscopic type of a cryostat was developed upon which eight SQUID gradiometers were mounted. As a result, small iron particles of 35 microns on a real lithium-ion battery anode with a width of 70 mm were successfully detected. This system is practical for the detection of contaminants in a lithium ion battery anode sheet.

대서양 아프리카 연안 트로올 어장의 어황변동에 관하여 1. 오징어, 살오징어, 문어 종의 어황 (On the Fluctuation of Trawl Fishing Condition in the Atlantic Coast of Africa 1. On the fishing condition of cutle fish, squid and octopus.)

  • 김진건
    • 수산해양기술연구
    • /
    • 제13권2호
    • /
    • pp.27-32
    • /
    • 1977
  • The paper deals the fishing condition of the stern trawlers operated in the Atlantic coast of Africa. The datas are gathered from the Korean stern trawlers operated in the area from June, 1975 to May, 1976. The obtained results are summarized as follows: 1. The mean catch per haul are calculated as, cuttle fish 14.5kg, large size squid(more than :lOOg of body weight) 28.2kg, small size squid(less than 300g) 36.4kg, octopus 47.0kg. 2. Small size cuttle fish(less than5OOg of body weight) are caught much during after spring tide in July to September, yet, large size ClIttle fish(more than 500g) are caught much during neap tide in October to January. 3. Small size squid(less than 300g of body weight) are cBught much during after spring tide in October to December, yet, large size squid(more than 3OOg) are caught much during before spring tide in October to March. 4. Octopus are caught during neap tide in July to August.

  • PDF

집적화된 Nb DC SQUID 소자의 제작 및 특성 (Fabrication and Characteristics of Integrated Nb DC SQUID)

  • 이용호;권혁찬;김진목;박종철
    • 한국자기학회지
    • /
    • 제2권3호
    • /
    • pp.277-281
    • /
    • 1992
  • 입력코일과 변조코일이 박막 형태로 집적화된 planar DC SQUID를 제작하고 그 특성을 조사하였다. SQUID loop은 균일한 외부자장의 영향을 받지 않도록 두개의 ring이 '8'자형으로 직렬로 연결된 구조를 하고 있으며, 조셉슨 접합으로는 Pd shunt 저항을 가지는 Nb/Al-oxide/Nb 턴넬 접합을 이용하였다. 소자는 포토리소그라피 기술과 RF 마그네트론 스퍼터링 및 양극산화 방법으로 제작하였으며, 제작된 SQUID는 4.2 K에서 기본적인 특성을 측정한 결과 standard readout 시스템에 적합한 매끄러운 특성을 보였으며 전압 잡음은 측정할 수 없을 정도로 작아 white noise는 최대 $10^{-4}\;{\phi}_o/\;\sqrt{H_z}$ 이하로 나타났다. 현재 matching 코일을 사용하여 잡음 특성을 측정중에 있으며 앞으로 SQUID parameter를 최적화할 경우 매우 고감도의 자기센서로 활용될 수 있을것으로 기대된다.

  • PDF

오징어류에 대한 트롤 끝자루의 망목선택성 (Mesh Selectivity of Trawl Cod-end for Squid)

  • 김삼곤;서두옥;안장영
    • 수산해양교육연구
    • /
    • 제9권1호
    • /
    • pp.71-82
    • /
    • 1997
  • 최근 오징어는 주요 대상어종이 되고 있으므로, 동중국해와 우리 나라 남해에서 어획되는 Short-finned squid와 Long-finned squid에 대해 분석하였다. 조업시험은 실습선 새바다호를 이용하여 다이아몬드형 망목에 의한 조업시험은 망목의 크기가 A(51.2mm), B(70.2mm), C(77.6mm), D(88.0mm), E(111.3mm)인 5종의 끝자루를 제작하여 1991년 6월부터 1992년 12월 중에 행하였으며, 정방형망목에 의한 조업시험은 망목의 크기가 A(51.2mm), B(70.2mm), C(77.6mm), D(88.0mm)인 4종의 끝자루를 제작하여 1992년 7월부터 1994년 6월 중에 행하였다. 다이아몬드형 망목과 정방형 망목의 끝자루에 Cover net를 부착하고 Trouser방식으로 실시하였다. 분석한 결과를 요약하면 다음과 같다. 1. 동장이 201mm 이상 되는 도피율은 D Type가 A type 보다 Short-finned squid는 55%, Long finned squid는 46% 컸다. 2. Short-finned squid의 어획량은 한국남해가 동중국해 보다 2.5배 많았으며, Long-finned squid는 동중국해가 한국남해 보다 14.3배 많았다. 3. 다이아몬드형 망목의 선택성곡선에서 Short-finned squid의 평균 선택동장 49mm, 평균 50% 선택동장 141mm 이었으며, Long-finned squid의 평균 선택동장 48mm, 평균 50% 선택동장 122mm 이었다. 정방형 망목의 선택성곡선에서 Short-finned squid의 평균 선택동장 67mm, 평균 50% 선택동장 156mm 이었으며, Long-finned squid의 평균선택 동장 60mm, 평균 50% 선택동장 137mm 이었다. 4. Short-finned squid에 대한 Master curve 선택성곡선 에서 다이아몬드형 망목은 기울기 3.01, 선택계수 2.10 이었으며, 정방형 망목은 기울기 1.82, 선택계수 2.37 이었다. Long-finned squid에 대한 Master curve 선택성곡선에서 다이아몬드형 망목은 기울기 3.11, 선택계수 1.81 이었으며, 정방형 망목은 기울기 2.35, 선택계수 2.08 이었다.

  • PDF

YBCO SQUID를 이용한 실험쥐의 심자도 측정 (Rat Magnetocardiograms Measured by YBCO SQUID Magnetometer)

  • 안산;김인선;송종현
    • Progress in Superconductivity
    • /
    • 제12권2호
    • /
    • pp.124-128
    • /
    • 2011
  • We have developed a high-$T_C$ SQUID magnetometer system to measure magnetocardiograms of laboratory rats. White noise of the measurement system was about 50 fT/$Hz^{1/2}$ when measured in a magnetically shielded box. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 50 pT. We could observe well defined P-, QRS-, and T-wave from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of heart disease model using laboratory rat.

소형 SQUID, 직접 되먹임 방식 전자회로, 고온초전도 SQUID 주사현미경의 개량 (Development of Small-sized SQUID and Direct-coupled Electronics for High-$T_c$ Scanning SQUID Microscope)

  • 백범;이승민;윤주환;김정구
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.78-82
    • /
    • 2001
  • The spatial resolution of $high-T_{c}$ scanning SQUID microscope is limited by the washer size of SQUID and the gap distance between SQUID sensor and the sample. In this work, we tried to improve the spatial resolution of scanning SQUID microscope by reducing the size of SQUID sensor fabricated with $YBa_2$$Cu_3$$O_{7}$ thin film. Outer dimensions of the SQUiDs we tested are 24 $\mu\textrm{m}$ $\times$ $ 28\mu\textrm{m}$, $12 \mu\textrm{m}$ $\times$ $16\mu\textrm{m}$, $12\mu\textrm{m}$ x $12\mu\textrm{m}$, $10 \mu\textrm{m}$ $\times$ $10 \mu\textrm{m}$ each. To operate them in the flux-locked loop scheme, we used a direct-coupled electronics instead of using conventional electronics involving a modulation scheme. Since the direct-coupled feedback scheme does not require modulation current adjustment that poses as a practical difficulty in the SQUID operation in modulation-scheme, the direct feedback operation is rather simpler than the conventional modulation method. The resulting noise features were dominated by the noise of preamp in FLL electronics except that of the largest SQUID. The noise levels of SQUIDs are expected below 1$\times$$10^{-5}$ $\Phi_{0}$H $z^{1}$2/ (at 300 Hz), that is a typical noise level for SQUID made of $YBa_2$C $u_3$$O_{7}$ thin film. The data acquisition and motion-controlling parts were also improved, resulting in faster data acquisition rate and less vibration of the system.m.

  • PDF