• Title/Summary/Keyword: The series connection-type

Search Result 108, Processing Time 0.031 seconds

Improvement of Current Limiting and Recovery Characteristics in Series Connection Type SFCL with Added Third Winding (3차권선이 추가된 직렬연결형 초전도한류기의 전류제한 및 회복 특성 향상)

  • Ko, Seok-Cheol;Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.62-68
    • /
    • 2014
  • The series connection type superconducting fault current limiter (SFCL) with added third winding, which was magnetically coupled in one iron core, was proposed. The proposed SFCL was expected to be more improved by just adding third winding into the conventional series connection type SFCL with two coils. To analyze the contribution of the third winding for the current limiting and the recovery characteristics of the SFCL, the short-circuit tests for the series connection type SFCL with the added third winding were performed together with the analysis on its electrical equivalent circuit. From the comparative analysis on the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising this SFCL, the improved current limiting and recovery characteristics of the series connection type SFCL using the third winding could be confirmed.

Analysis on Current Limiting Characteristics of Series Connection-type SFCL with Two Magnetically Coupled Circuits Applied into a Simulated Power System (모의전력계통에 적용된 두 개의 자기결합 회로를 갖는 직렬연결형 초전도 전류제한기의 전류제한 특성 분석)

  • Ko, Seok-Cheol;Lee, Shin-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.1
    • /
    • pp.68-72
    • /
    • 2013
  • The series connection-type superconducting fault current limiter (SFCL) with two magnetically coupled circuits was suggested and its effectiveness through the analysis on the current limiting and recovery characteristics was described. The fault current limiting characteristics of the proposed SFCL as well as the load voltage sag compensating characteristics according to the winding direction were investigated. To confirm the fault current limiting and the voltage sag suppressing characteristics of the this SFCL, the short-circuit tests for the simulated power system with the series connection-type SFCL were carried out. The series connection-type SFCL designed with the additive polarity winding was shown to perform more effective fault current limiting and load voltage sag compensating operations through the fast quench occurrence right after the fault appears and the fast recovery operation after the fault removes than that with the subtractive polarity winding.

Improvement of Current Limiting and Recovery Characteristics of Flux-Lock Type SFCL with Series Connection of Two Coils Using Its Third Coil

  • Ko, Seok-Cheol;Kim, Young-Pil;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.472-477
    • /
    • 2017
  • In this work, the current limiting and recovery characteristics of a flux-lock type superconducting fault current limiter (SFCL) with series connection of two coils were effectively improved by adding a third winding into the conventional flux-lock type SFCL with series connection of two coils. To confirm the contribution of the third winding to the current limiting and recovery characteristics of this type of the SFCL, short-circuit testing was carried out with consideration of the third winding, and the effect of the third winding on the current limiting and recovery characteristics was examined by comparative analysis of the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising the SFCL. Through the analysis of both the limiting impedance and the operational current as the main design parameter of the SFCL, the improved current limiting and recovery characteristics of the flux-lock type SFCL using the third winding could be verified.

Quench Characteristics of Flux-lock Type SFCL in Subtractive Polarity Winding (감극 결선시 자속구속형 전류제한기의 퀜치 특성)

  • Hwang, Jong-Sun;Han, Tae-Hee;Choi, Hyo-Sang;Park, Hyoung-Min;Cho, Yong-Sun;Nam, Guong-Hyun;Lee, Na-Young;Lim, Sung-Hun;Chung, Dong-Chul;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.251-252
    • /
    • 2006
  • As one of methods to increase the voltage rating of the flux-lock type SFCL, the fault current limiting characteristics of the flux-lock type SFCL with HTSC elements connected in series were analyzed. The initial fault current amplitudes in two SFCLs with the series connection of two HTSC elements and with single HTSC element were the same. In addition, the resistance amplitude of each HTSC element in SFCL with the series connection of two HTSC elements had the similar one in SFCL with single HTSC element. With increase of applying voltage, the unbalance of voltage between two HTSC elements in SFCL with the series connection of two HTSC elements disappeared.

  • PDF

Types of Misconceptions and their Consistencies of the Elementary School Teachers about the Characteristics of Currents according to the Connection Methods of Batteries in Simple Electric Circuits (전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 오개념 유형과 그 일관성)

  • Hyun, Dong-Geul;Shin, Ae-Kyung
    • Journal of Science Education
    • /
    • v.38 no.2
    • /
    • pp.331-343
    • /
    • 2014
  • The types of misconceptions and their consistencies of the elementary school teachers about the characteristics of currents according to the connection methods of batteries in simple electric circuits were investigated. The misconceptions of the elementary school teachers about them could be divided into three types. Among the respondents of the 96 elementary school teachers for this study, the 2 elementary school teachers consistently understood the characteristics of currents on the basis of the misconception type of focusing only the number of batteries connected regardless of the connection methods of batteries, the 8 elementary school teachers did on the basis of the misconception type of confusing the series connection and the parallel connection of batteries, and the 4 elementary school teachers did on the basis of the misconception type of confusing the series and parallel connection of batteries with those of resistors. Also, they consistently applied these misconception types to not only the situations to use the learned concepts but the situations to use the differentiated concepts about the connection methods of batteries.

  • PDF

Quench Characteristics of Superconducting Elements using Reactors at Series and Parallel Connections (직·병렬연결시 리액터를 이용한 초전도 소자의 퀜치 특성)

  • Choi, Hyo-Sang;Lim, Sung-Hun;Cho, Yong-Sun;Nam, Gueng-Hyun;Lee, Na-young;Park, Hyoung-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.9
    • /
    • pp.863-869
    • /
    • 2005
  • We investigated quench characteristics of superconducting elements connected in series and parallel each other. The serial and parallel connections of superconducting elements causes a difficulty in simultaneous quench due to slight difference between their critical current densities. In other to induce simultaneous quench, we fabricated four type circuits; serially connected circuit before parallel connection, the circuit connected in parallel before serial connection, serially connected circuit before parallel connection with reactors, the circuit connected in Parallel before serial connection with reactors. We confirmed that the simultaneous quenches occurred in serial and parallel connections of superconducting elements using reactors. In addition, the power burden of superconducting elements was smaller than those of serial and parallel connections of superconducting elements without reactors.

Characteristics of a Flux-Lock Type Superconducting Fault Current Limiter According to the Parallel Connection of the Superconducting Elements. (초전도 한류소자의 병렬연결에 따른 자속구속형 초전도 한류기의 특성 분석)

  • Oh, Kum-Gom;Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.198-201
    • /
    • 2008
  • We investigated the operating characteristics of the flux-lock type superconducting fault current limiter(SFCL) with the parallel connection between the primary and secondary windings which are connected with two superconducting units in series. The parallel connection for current level increase of the flux-lock type SFCL is necessary to apply the SFCL into the power system. The resistance generated in superconducting units was dependent upon the winding direction of the primary and the secondary coils, which can reduce the power burden. The resistance of the superconducting elements in the subtractive polarity winding is higher than that of the additive polarity winding. The fault current limiting effect of the subtractive polarity winding is better than that of the additive polarity winding. From this results, we confirmed that the power capacity of the flux-lock type SFCL could be increased by the parallel connection of the superconducting units.

Improvement of Simultaneous Quench Characteristic of Flux-Lock Type Superconducting Fault Current Limiters Through Its Series Connection (자속구속형 초전도 사고전류 제한기의 직렬연결을 통한 동시 퀜치 특성 향상)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.102-106
    • /
    • 2007
  • To apply the flux-lock type superconducting fault current limiter(SFCL) into power system, its current and voltage ratings are required to increase. Especially, in case of series connection of SFCLs, the countermeasure for simultaneous quenches must be considered. The structure, which each flux-lock type SFCL unit was wound in series on the same iron core, can induce the simultaneous quench of superconducting elements. Through the fault current limiting experiment for the suggested structure, it was confirmed that the even voltage burden among the superconducting elements comprising SFCLs could be made.

Characteristics of Superconducting Elements in Series-Connected Three-Phase Flux-Lock type SFCL (3상 자속구속형 한류기의 초전도 소자 직렬연결 특성분석)

  • Park, Hyoung-Min;Choi, Hyo-Sang;Cho, Yong-Sun;Hwang, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.35-36
    • /
    • 2007
  • We investigated the characteristics of three phase flux-lock type SFCL. Three phase flux-lock type consists of three reactor wound on an iron core in each single phase and the secondary coil is connected to the superconducting elements in series. the superconducting elements with serial connection were quenched simultangously in the single line-to-ground fault.

  • PDF

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.