• 제목/요약/키워드: The main material of building

검색결과 283건 처리시간 0.024초

열반사성 외장마감재의 온도조절 성능에 관한 연구 (A Study on the Temperature Controlled Performance of Thermal Reflective Exterior Finishes)

  • 류화성;신상헌;송성용;김득모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.186-187
    • /
    • 2019
  • In modern times, due to the centralized urban structure, the interval between buildings is narrow and the increase of the heat island phenomenon due to the accumulation of the structure is becoming a social problem. In order to solve these problems, various materials for reducing the surface temperature of buildings are under study. Particularly, in the case of a wall part which is a part directly affected by the outside air of the building, it is a main structural part for determining the room temperature. The purpose of this study was to develop a material that can improve the thermal environment performance of the building by evaluating the temperature control performance of the exterior finishing material using the heat reflecting material as a method for controlling the temperature of the outer wall finishing material.

  • PDF

Fundamental Investigation of Functional Property of Concrete Mixed with Functional Materials

  • Lee, Jong-Chan;Lee, Moon-Hwan;Lee, Sae-Hyun;Park, Young-Sin;Park, Jae-Myung
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.165-171
    • /
    • 2006
  • Environment-friendly materials are increasingly used as building construction materials nowadays, and the market share of those is growing. Accordingly, the research and developments in terms of environmental value are progressing steadily now. The main characteristics of environmental products are far-infrared radiation, negative-ion emission, electromagnetic wave shielding, and antimicrobial property. These products are often used in mortar and as spray on the finishing material. Nevertheless, there are hardly any research on the functional properties of concrete, the main material in construction field. Thus, we evaluated such basic properties of concrete as slump, compressive strength and air content while using such functional materials as sericite, wood-pattern sandstone, carbon black and nano-metric silver solution to focus on their functional properties like far-infrared radiation, negative ion emission, electro magnetic wave shielding, and antimicrobial activity in this research. The results indicated that the most useful material in the functional materials was carbon black. Sericite and nano-metric silver solution had a little effect on the functional property. Moreover, although wood-pattern sandstone had very high functional property, it exhibited too low compressive strength to be applied, to concrete as a factory product. Antimicrobial property of nano-metric silver solution in the concrete was not clear demonstrated, but if these specimens were to be aged in $CO_2$ gas for a long time, it might be apparent.

MOVEMENT CONTROL OF HIGH-RISE BUILDINGS DURING CONSTRUCTION

  • Taehun Ha;Sungho Lee;Bohwan Oh
    • 국제학술발표논문집
    • /
    • The 4th International Conference on Construction Engineering and Project Management Organized by the University of New South Wales
    • /
    • pp.46-51
    • /
    • 2011
  • High-rise buildings are widely being constructed in the Middle-East, South-East, and East Asia. These buildings are usually willing to stand for the landmark of the region and, therefore, exhibit some extraordinary features such as super-tall height, elevation set-backs, overhangs, or free-form exterior surface, all of which makes the construction difficult, complex, and even unsafe at some construction stages. In addition to the elaborately planned construction sequence, prediction and monitoring of building's movement during construction and after completion are required for precise and safe construction. This is often called the Building Movement Control during construction. This study describes Building Movement Control of the KLCC Tower, a 58-story office building currently being built right next to the famous PETRONAS Twin Towers. The main items of the Building Movement Control for the KLCC Tower are axial shortening and verticality. Preliminary prediction of these items are already carried out by the structural design team but more accurate prediction based on construction stage analysis and combined with time-dependent material testing, field monitoring, and site survey is done by the main contractor. As of September 2010, the Tower is under construction at level 30, where the plan abruptly changes from rectangle to triangle. Findings and troubleshooting until the current construction stage are explained in detail and implementations are suggested for future applications.

  • PDF

건축물의 실내건축 재료에 관한 화재안전성 연구 (A Study on the Fire Safety Performance of Interior Surface Materials in a Building)

  • 서수은;신승우
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2013년 추계학술대회
    • /
    • pp.275-290
    • /
    • 2013
  • The main cause of building fire fatalities occur in the combustible material heat, smoke and toxic gases are. Building interior decoration, etc., especially as much of the harmful substances generated during combustion, and, used in domestic architecture wallpaper, ceiling, and other plastics, built-in foam insulation also analyzed recognition of fire hazards approach to test the conkalrorimiteo test, choedaeyeolbangchulryul through, chongbal heat, mass loss rate, generates carbon monoxide gas hazard ratio tests, analysis and evaluation rigid foam index testing the toxicity of hazardous material generated by performing a gas clean up and assess the material test results, the minimum order to provide data to quantify the risk of fire. Ensure fire safety of building materials, composite materials in order to test the various risk factors could be considered organic to the introduction of testing and evaluation is needed urgently.

  • PDF

재료의 경년상태를 고려한 PSC격납건물의 극한내압능력 평가 (Evaluation of Ultimate Pressure Capacity of Prestressed Concrete Containment Building Considering Aging of Materials)

  • 이상근;송영철;권용길;한상훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.805-810
    • /
    • 2000
  • The purpose of this study is to predict long-term structural safety on the Yonggwang Unit 3 prestressed concrete containment building. The aging-related degradations of its main structural materials are investigated and the effects of the property variation of time-dependent materials on the structural behavior of containment building are also assessed through the analysis on the ultimate pressure capacity. The nonlinear finite element analyses for both the design criteria condition a the present aging condition are conducted to assess the present structural capacity of the containment building As a result, it is verified that the structural capacity of the Yonggwang Unit 3 containment building under the present aging condition is judged to be still rugged. n addition, the sensitivity of the ultimate pressrue capacity of containment building according to th degradation levels of the structural materials are assessed. Finally, it is showed that the sensitivity levels are in the order of the tendon, rebar and concrete in case of individual material degradations, and the tendon-rebar, tendon-concrete and rebar-concrete in case of coupled material degradations.

  • PDF

Performance-based Design of 300 m Vertical City "ABENO HARUKAS"

  • Hirakawa, Kiyoaki;Saburi, Kazuhiro;Kushima, Souichirou;Kojima, Kazutaka
    • 국제초고층학회논문집
    • /
    • 제3권1호
    • /
    • pp.35-48
    • /
    • 2014
  • In designing a 300 meter high skyscraper expected to be the tallest building in Japan, an earthquake-ridden country, we launched on the full-scale performance based design to ensure redundancy and establish new specifications using below new techniques. The following new techniques are applied because the existing techniques/materials are not enough to meet the established design criteria for the large-scale, irregularly-shaped building, and earth-conscious material saving and construction streamlining for reconstructing a station building are also required: ${\bullet}$ High strength materials: Concrete filled steel tube ("CFT") columns made of high-strength concrete and steels; ${\bullet}$ New joint system: Combination of outer diaphragm and aluminium spray jointing; ${\bullet}$ Various dampers including corrugated steel-plate walls, rotational friction dampers, oil dampers, and inverted-pendulum adaptive tuned mass damper (ATMD): Installed as appropriate; and ${\bullet}$ Foundation system: Piled raft foundation, soil cement earth-retaining wall construction, and beer bottle shaped high-strength CFT piles.

사무소 건축물의 건축기계설비 배관 부속자재 요율 산출 (Calculation of the Attached-Piping-Material Rate for the Building Mechanical-Service System in Office Buildings)

  • 박률
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.185-194
    • /
    • 2017
  • Currently, in comparison with other architectural estimations, the estimation work regarding building mechanical-service systems is time-consuming, and the process is continuously becoming more difficult because of the increased usage of the attached piping materials such as fittings and hangings in addition to their complicated construction processes. To improve this problem, the Korean authority provides a simple estimation method for the attached-material rate regarding the main piping material, which is the most time-consuming work in the architectural-mechanical estimation. However, to be an applicable method on construction sites, a proper conversion rate of the attached-piping material is still required for the proposed method regarding building usage and working types. Therefore, the purpose of this research is the calculation of the rate of the attached-piping materials such as the fittings and supports through the building of the mechanical-service work types of mechanical rooms, air conditioning, domestic water and hot-water supplies, and the drain-, vent-, and gas-piping work in office buildings that have been designed after 2010.

수조구조물의 방수.방식 공사용 유기.무기 소재 및 섬유보강형 바탕처리재의 성능평가에 관한 연구 (A Study on Waterproofing and Anticorosive Performance Evaluation of Surface treatment material used wi th Glass Fiber, Inorganic and Organic Material for Water Tank)

  • 오상근;박봉규;주웅일;박성진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.70-75
    • /
    • 2001
  • There is a problem to be solved for improvement of durability and safety for concrete When the waterproofing and anticorrosive work of main concrete are design, the material a of construction need to be correctly applied to appropriate circumstance conditions. Epoxy mostly been used for concrete water tank structure. Lately, lots of subjects on adaption res in mortar for waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with waterproofing materials in this experiment. Capability evaluation items include the bond age and curing conditions, the bond strength after accelerated weathering test and fret impact resistance, a mount of water, seepage quan Through the experiment analysis, we found that waterproofingtity, drinking water chemicals resistance. and anticorrosive resin mortar used with glass fiber cloth, inorgar material is dominantly superior to other waterproofing materials. According to this paper, we suggest the resin mortar as a new surface treatment material water tank structure.

  • PDF

다중이용업소 실내마감재료 사용기준에 관한 연구 (A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses)

  • 김용성;조성오
    • 한국실내디자인학회논문집
    • /
    • 제22권5호
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.

황토를 이용한 건자재의 생산현황에 대한 조사연구 (Investigation of the present production trend of building material in relation to loess)

  • 조창희;김진관;이병호
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.107-114
    • /
    • 2012
  • This is a study that surveyed and analyzed the present status of producing loess construction materials in Korea from 2006 to 2011. The findings are as follows. 1) More than 70% of loess construction material manufacturers are distributed in the capital area. Chungcheong-do and Gyeonggi-do are grown by about 20% on the annual average. 2) Shape of loess brick is possessed mostly by a rectangular parallelepiped. A hole shape, which has 1~5 holes among these things, is possessing a majority. 3) It was indicated to be 42 days as material age for the compressive strength, to be about 2.7Mpa for both extrusion and compression, and to be about 30% for absorptance. 4) Among the whole loess material manufacturers, it accounts for 87 for loess brick 66% for loess mortar and more than 39% for loess paint, but within 10%~15% for other loess products. 5) The main specifications of loess brick are $300{\times}150{\times}150,\;300{\times}150{\times}100,\;300{\times}200{\times}150,\;300{\times}150{\times}200$ in order of the output of 74kinds of loess bricks. 6) In order to improve the strength of building materials, mortar and concrete used loess, it is necessary to examine closely about the effect of ceramic binder and cement on loess products.