• Title/Summary/Keyword: The current image

Search Result 2,254, Processing Time 0.033 seconds

Study on image quality improvement using Non-Linear Look-Up Table (비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구)

  • Kim, Sun-Chil;Lee, Jun-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF

Estimation of Sea Surface Current Vector based on Satellite Ocean Color Image around the Korean Marginal Sea

  • Kim, Eung;Ro, Young-Jae;Ahn, Yu-Hwan
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.816-819
    • /
    • 2006
  • One of the most difficult parameters to measure in the sea is current speed and direction. Recently, efforts are being made to estimate the ocean current vectors by utilizing sequential satellite imageries. In this study, we attempted to estimated sea surface current vector (sscv) by using satellite ocean color imageries of SeaWifs around the Korean Peninsula. This ocean color image data has 1-day sampling interval and spatial resolution of 1x1 km. Maximum cross-correlation method is employed which is aimed to detect similar patterns between sequential images. The estimated current vectors are compared to the surface geostrophic current vectors obtained from altimeter of sea level height data. In utilizing the color imagery data, some limitations and drawbacks exist so that in warm water region where phytoplankton concentration is relatively lower than in cold water region, estimation of sscv is poor and unreliable. On the other hand, two current vector fields agree reasonably well in the Korean South Sea region where high concentration of chlorophyll-a and weak tide is observed. In the future, with ocean color images of shorter sampling interval by COMS satellite, the algorithm and methodology developed in the study would be useful in providing the information for the ocean current around Korean Peninsula.

  • PDF

A study of characteristics for Image sticking in AC - Plasma Display Panel

  • Han, Yong-gyu;Lee, S.B.;Jeong, S.H.;Son, C.G.;Yoo, N.L.;Lee, H.J.;Lim, J.E.;Lee, J.H.;Jeoung, J.M.;Ko, B.D.;Oh, P.Y.;Moon, M.W.;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.263-265
    • /
    • 2005
  • In the alternative current plasma display panel(AC-PDP) technology, it is very important to remove the image sticking for improving an image quality. In this paper, we have investigated the driving method of alternative current plasma display panel(AC-PDP) for preventing image sticking. We have investigated the driving method of alternative current plasma display panel(AC-PDP) for preventing image sticking. The preventing method of image sticking was proposed by adopting the Sticking Remove Pulse(SRP). The variation of brightness is most affected by the MgO to be formed at the surface of the phosphor layer. As a result, the image sticking is reduced when the driving method adopted an SRP.

  • PDF

Analysis of Surface Current Measurement Based on X-band Radar Image (X-밴드 레이더 이미지 기반 표층해류 계측 분석)

  • Na-Yun Kang;Yu-Kyung Lee;Young-Jun Yang
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.323-324
    • /
    • 2022
  • This paper explains the comparison results of surface current measurement using X-band Radar image through analysis. Measurements were carried out from February 2022 using the X-band Radar for marin ships installed at Sokcho Beach. Based on the Korea Hydrographic and Oceanographic Agency ocean observation buoys, the accuracy of surface current(current speed) measurement was verified through comparison and analysis of measurement data.

  • PDF

Effective Exemplar-Based Image Inpainting Using Patch Extrapolation (패치 외삽을 이용한 효과적인 예제기반 영상 인페인팅)

  • Kim, Jin-Ju;Lee, Si-Woong
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2014
  • Image inpainting is the widely used technique to restore a damaged region or to fill a hole in an image. The exemplar-based technique effectively generates new texture by copying colour values of the most correlated patch in the source into the empty region of the current patch. In traditional exemplar-based synthesis, the patch correlation is computed using only the already filled pixels of the current patch. Thus, by ignoring the correlation between the hole regions of the two patches, an undesirable patch which is highly correlated with the current patch in the already filled area but considerably dissimilar in the area to be filled can be selected, which results in bad texture propagation. To avoid such problems, a new exemplar-based inpainting method using patch extrapolation is proposed. The empty part of the current patch is extrapolated beforehand, and then the complete patch is used for finding its exemplar. Experimental results show that the proposed method provides more natural synthesis results than the conventional ones.

Effects of Annealing Temperature on the Local Current Conduction of Ferromagnetic Tunnel Junction (열처리에 따른 강자성 터널링 접합의 국소전도특성)

  • Yoon, Tae-Sick;Tsunoda, Masakiyo;Takahashi, Migaku;Li, Ying;Park, Bum-Chan;Kim, Cheol-Gi;Kim, Chong-Oh
    • Korean Journal of Materials Research
    • /
    • v.13 no.4
    • /
    • pp.233-238
    • /
    • 2003
  • Ferromagnetic tunnel junctions, Ta/Cu/Ta/NiFe/Cu/$Mn_{75}$ $Ir_{25}$ $Co_{70}$ $Fe_{30}$/Al-oxide, were fabricated by do magnetron sputtering and plasma oxidation process. The effect of annealing temperature on the local transport properties of the ferromagnetic tunnel junctions was studied using contact-mode Atomic Force Microscopy (AFM). The current images reflected the distribution of the barrier height determined by local I-V analysis. The contrast of the current image became more homogeneous and smooth after annealing at $280^{\circ}C$. And the average barrier height $\phi_{ave}$ increased and its standard deviation $\sigma_{\phi}$ X decreased. For the cases of the annealing temperature more than $300^{\circ}C$, the contrast of the current image became large again. And the average barrier height $\phi_{ave}$ decreased and its standard deviation $\sigma_{\phi}$ increased. Also, the current histogram had a long tail in the high current region and became asymmetric. This result means the generation of the leakage current that is resulted from the local generation of a low barrier height region. In order to obtain the high tunnel magnetoresistance(TMR) ratio, the increase of the average barrier height and the decrease of the barrier height fluctuation must be strictly controlled.led.

SOI CMOS image sensor with pinned photodiode on handle wafer (SOI 핸들 웨이퍼에 고정된 광다이오드를 가진 SOI CMOS 이미지 센서)

  • Cho, Yong-Soo;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.341-346
    • /
    • 2006
  • We have fabricated SOI CMOS active pixel image sensor with the pinned photodiode on handle wafer in order to reduce dark currents and improve spectral response. The structure of the active pixel image sensor is 4 transistors APS which consists of a reset and source follower transistor on seed wafer, and is comprised of the photodiode, transfer gate, and floating diffusion on handle wafer. The source of dark current caused by the interface traps located on the surface of a photodiode is able to be eliminated, as we apply the pinned photodiode. The source of dark currents between shallow trench isolation and the depletion region of a photodiode can be also eliminated by the planner process of the hybrid bulk/SOI structure. The photodiode could be optimized for better spectral response because the process of a photodiode on handle wafer is independent of that of transistors on seed wafer. The dark current was about 6 pA at 3.3 V of floating diffusion voltage in the case of transfer gate TX = 0 V and TX=3.3 V, respectively. The spectral response of the pinned photodiode was observed flat in the wavelength range from green to red.

A Review of Mobile Display Image Quality

  • Kim, Youn Jin
    • Information Display
    • /
    • v.15 no.5
    • /
    • pp.22-32
    • /
    • 2014
  • The current research intends to quantify the surround luminance effects on the shape of spatial luminance CSF and to propose an image quality evaluation method that is adaptive to both surround luminance and spatial frequency of a given stimulus. The proposed image quality method extends to a model called SQRI[8]. The non-linear behaviour of the HVS was taken into account by using CSF. This model can be defined as the square root integration of multiplication between display MTF and CSF. It is assumed that image quality can be determined by considering the MTF of the imaging system and the CSF of human observers. The CSF term in the original SQRI model was replaced by the surround adaptive CSF quantified in this study and it is divided by the Fourier transform of a given stimulus. A few limitations of the current work should be addressed and revised in the future study. First, more accurate model predictions can be achievable when the actual display MTF is measured and used instead of the approximation. Then, a further improvement to the model prediction accuracy can be made when chromatic adaptation of the HVS is taken into account[45-46].

A Design of Single Pixel Photon Counter for Digital X-ray Image Sensor (X-ray 이미지 센서용 싱글 픽셀 포톤 카운터 설계)

  • Baek, Seung-Myun;Kim, Tae-Ho;Kang, Hyung-Geun;Jeon, Sung-Chae;Jin, Seung-Oh;Huh, Young;Ha, Pan-Bong;Park, Mu-Hun;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.322-329
    • /
    • 2007
  • A single pixel photon counting type image sensor which is applicable for medical diagnosis with digitally obtained image and industrial purpose has been designed with $0.18{\mu}m$ triple-well CMOS process. The designed single pixel for readout chip is able to be operated by single supply voltage to simplify digital X-ray image sensor module and a preamplifier which is consist of folded cascode CMOS operational amplifier has been designed to enlarge signal voltage(${\Delta}Vs$), the output voltage of preamplifier. And an externally tunable threshold voltage generator circuit which generates threshold voltage in the readout chip has been newly proposed against the conventional external threshold voltage supply. In addition, A dark current compensation circuit for reducing dark current noise from photo diode is proposed and 15bit LFSR(Linear Feedback Shift Resister) Counter which is able to have high counting frequency and small layout area is designed.

Analysis of the Motion Picture Quality of Stereoscopic Three-dimensional Images

  • Choi, Hee-Jin;Jung, Jae-Hyun;Kim, Hwi;Lee, Byoung-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.383-387
    • /
    • 2010
  • The stereoscopic three-dimensional (3D) display provides a 3D image by inducing binocular disparity for the observers who wear special glasses. With the rapid progress in flat panel display technologies, the stereoscopic 3D display is becoming a new benefit-model of the current display industry, and several kinds of commercial stereoscopic 3D products have been released and are attracting people. Nowadays, the motion picture quality of the 3D image becomes as important as resolution or luminance since most of the commercial 3D products are 3D televisions or 3D monitors which are required to display a clear motion 3D image. In this paper, an analysis and simulation of the motion picture quality of stereoscopic 3D image is proposed, and a comparison of the motion picture performance among the current stereoscopic 3D technologies is also provided.