A Study on the Maintenance Cost Estimation Model of the Apartment Housing (공동주택의 관리비 추정모델 연구)

  • Lee, Kang-Hee;Yang, Jae-Hyuk;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.59-67
    • /
    • 2010
  • The maintenance cost plays a important role to plan the scale of the apartment housing such as a number of household, building area and building type. Therefore, it is required to forecast the cost considering various maintenance characteristics. The maintenance characteristics are floor area, number of household, heating type, site area and etc.. In addition, the maintenance cost are classified into 5 area. These are a personal expense, facility maintenance cost, energy and water cost, insurance and sanitary cost. These five cost area are related with various characteristics and brought up the estimation model using the stepwise multiple regression analysis. The energy and heating cost share over the 50% in the total cost and the personal expense cost shares about 40%. The personal expense cost per area is 5,272 won/$m^2{\cdot}yr$ irregardless of heating type and the district heating type is a higher cost than other type. In facility maintenance cost, the central heating type is 2,015 won/$m^2{\cdot}yr$ and higher than other type. The estimation models have good statistics in each model. Most of the model have a determination coefficient over 0.7 and Durbin Watson value between 1.5 and 2.5.

A study on the suitable of building size in district units plan (지구단위계획(地區單位計劃)에서 건축(建築) 규모설정(規模設定)에 관한 연구(硏究))

  • Lee, Won-Geun;Lee, Jae-Kook;Do, Gyu-Hwan
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.1
    • /
    • pp.39-49
    • /
    • 2003
  • The height provisions, by the urban planning, describe the hightest height per width division, also define oblique line limitation by road without mentioning the highest per width division. Therefore this study will be a basic model for the standard of measuring the highest height per width division analysizing the propriety of current standard of oblique limitation. This technique is prepared to prevent the confusion and to complements the existing planning method. Therefore, it takes more time to establish this new method and to apply it to the existing condition. This study reviewed density control in District Units Plan, based on the guidelines of density, which included height, ratio of total floor to ground area, and land distribution. This study aims to provide efficient analysis by using current oblique limitation provisions Thus, proving the area rations of general residential areas are decreasing. Since the purpose of the District Units Plan is to avoid confusion and help ease the existing problematic conditions which have risen from the two above-mentioned conventional systems, further observation and research on these areas are necessary.

  • PDF

Establishment of a Estimation Model of On-Road and Off-Road Parking Demand Based on the Total Floor Area of Buildings (건축물 연면적에 따른 노상·노외 주차수요 산정 모형 구축)

  • Je mo Nam;Young woo Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.2
    • /
    • pp.44-53
    • /
    • 2023
  • Recently, serious parking problems are occurring due to the difficulty of securing sufficient parking space, and it may lead to other traffic or social problems. In order to solve the parking problem in areas and districts beyond a certain range, a study on-roads and off-street parking lots reflecting regional characteristics is necessary. Therefore, this study establishing a parking demand calculation model for use as a basic study in establishing on-road and off-road characteristics. In order to conduct the study, Dong-fu, Daegu Metropolitan City was divided into dongs, and parking facilities and parking demand were investigated. The survey time was divided into daytime and nighttime on weekdays, and the types of vehicles were divided into three types: passenger car, small trucks and buses, large trucks and buses. As explanatory variables for calculating parking demand, the total floor area of buildings for each of six purposes was used, including detached houses, apartment houses, neighborhood living facilities, cultural and assembly facilities, business facilities, and sales facilities. As a result of the correlation analysis, among the six explanatory variables, the total area of neighborhood living facilities showed a significant correlation with on- and off-street parking demand. A regression analysis model was constructed using the total area of neighborhood living facilities as an explanatory variable, and statistically significant results were obtained.

The Evaluation of Architectural Density on Urban District using Airborne Laser Scanning Data (항공레이저측량 자료를 이용한 시가지 건축밀도 평가에 관한 연구)

  • Lee, Geun-Sang;Koh, Deuk-Koo;Cho, Gi-Sung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.6 no.3
    • /
    • pp.95-106
    • /
    • 2003
  • This study evaluated the architectural density of urban district using airborne laser scanning(ALS) that is a method used in urban planning, water resources and disaster prevention with high interest recently. First, digital elevation model(DEM) and digital surface model(DSM) was constructed from Light detection and ranging(LiDAR). For getting the height of building, ZONALMEAN filter was used in DEM and ZONALMAJORITY filter was used in DSM. This study compared the floor from filtering with the floor from survey and got standard error, which is ${\pm}0.199$ floor. Also, through the overlay and statistical analysis of total-area layer and zone layer, we could present floor area ratio by zone. As a result of comparison with floor area ratio between airborne laser scanning data and survey data, the standard error of floor area ratio shows ${\pm}2.68%$. Therefore, we expect that airborne laser scanning data can be a very efficient source to decision makers who set up landuse plan in near future.

  • PDF

A Study on the Space Programming of Prayer House feature (기도원 시설의 공간구성 특성에 관한 연구)

  • 장경수
    • Korean Institute of Interior Design Journal
    • /
    • no.19
    • /
    • pp.105-113
    • /
    • 1999
  • This study investigates the prayer House facilities in Korean Churches and improves them to the positive way in order to revive the church itself. The prayer houses in Korea manages the various facilities and special programs. Theses facilities are used in christian seminars, educations, belief-training for the more non-christian's resort and training center when they could meet the god naturally. The purpose of this paper suggests the condition of the current prayer house facilities and the main organizers. this leads the fundamental data for the patterns of the unit facilities. Methods of study and range are 20 places among Seoul, Kyunggi - do area and analyse document survey, phone interview, drawing analysis, direct visit including the prayer house type, building area, site area, total floor area, location condition as searching items.

  • PDF

Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul- (공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 -)

  • Park, So-Yun;Lee, Yun-Jae;Lee, Hyun-Soo
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.

Development of Economic Analysis Model for Rebuilding Feasibility Evaluation of Old School Building (노후 학교건물의 개축 타당성 평가를 위한 경제성 분석 모델 개발)

  • Lee, Changsu;Ahn, Heejae;Kwon, Woobin;Kim, Minju;Kim, Harim;Cho, Hunhee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.273-274
    • /
    • 2023
  • Although there are many old school buildings that is more than 40 years in Korea, it is difficult to rebuild all of them due to limitations in budget management. Therefore, objective feasibility evaluation criteria are necessary to determine which school buildings should be rebuilt preferentially among the numerous old school buildings. One of the rebuilding feasibility evaluation items, economic evaluation generally requires documents such as construction statements and facility drawings. However, because most buildings older than 40 years do not have these documents, an economic analysis model that requires only basic building information should be developed. In this study, the economic analysis model that can be used for evaluating the rebuilding feasibility only with the number of years, total floor area, and structural information of school buildings was established. This model can contribute to the objective feasibility evaluation of old school buildings because it can evaluate numerous buildings on the same criteria based on basic building information.

  • PDF

Analysis of Rent-Free Determinants : Evidence from Seoul Office Market (오피스 렌트프리 결정요인 분석 : 서울시를 중심으로)

  • Han, Gwang-Ho;Kwon, Hee-Jae;Ro, Seung-Han
    • Journal of Cadastre & Land InformatiX
    • /
    • v.49 no.1
    • /
    • pp.5-15
    • /
    • 2019
  • This study is to review methodological limitations of previous studies, propose Tobit Model as an analysis model. We model used annual rent-free as dependent variable and considering to contract characteristics and building characteristics as independent variable. We model was consisted to the three model as follow: Basic model, Time control model, Quadratic model. As a result of the analysis, existing variables revealed through previous studies such as contract period, contract area, total floor area, and building age were all statistically significant. These results were robust when considering time effects. Also, floor area and annual rent-free was quadratic relationship by inverse U shape. This result provide to methodological contribution for related research. Also, provide to more accurate information for participants in seoul office market.

A Systematic Review of the Mechanical CPR and Manual CPR on Out-of-Hospital Cardiac Arrest Occurring in High-rise Building

  • ChanHo, Lee;ByounGgil, Yoon;HongBeom, Ahn;YongSeok, Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.434-443
    • /
    • 2022
  • CPR in High-rise building is one of the challenging tasks to 119 paramedics, evacuating patient from the narrow and vertical area. This study was built to compare the method of mechanical CPR and manual CPR is to maximizing on-scene treatment time, and minimizing the hand-off time in cardiac arrest, transporting patient as fast as possible. The electronic data research (Science, Pubmed, Medline, Medline and 55 academic DB interworking) was conducted, and five articles were included by reviewing and excluding through the Covidence program and Review Manager version 5.4(Cochrane Collaboration). OHCA occurring on the higher floor indicates lower in survival. A total studies uniformly reported mechanical CPR is more effective during the high-rise building evacuation, than manual CPR in rate, depth, and hands-on time of chest compression. Use of mechanical CPR device is more suitable in case of High-rise building OHCA to improve the survival rate which is affected by high-quality CPR.

Characteristics of Modernized Hanok for development Estimate system. (개략견적 기법 개발을 위한 신한옥 특성 분석)

  • Kim, Hyo-Sun;Jung, Young-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.124-125
    • /
    • 2013
  • The purpose of this research is to propose an approximate estimation system for Modernized Hanok. Mock-up (Jisinjae) site data has been collected and analysed to characterize the modernized Hanok and to examine the range of cost fluctuation rate with each work items. As a result, number of floor, area (㎥), shape, methods and materials were considered as key factors for price change on the total construction cost. Furthermore, wood structure (34%) and roof (17%) account for major cost percentage. The cost fluctuation rate of two factors were -3.3%~+5.6% (wood structure) and -4.1%~+4.2% (roof). For further research, existing method will be analysed in order to developing the Hanok estimation system. And the cost fluctuation rate of every work items will be continually evaluated.

  • PDF