• Title/Summary/Keyword: The amount of deviation

Search Result 413, Processing Time 0.022 seconds

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

Design and Implementation of a Novel Frequency Modulation Circuit using Phase Locked Synthesizer (PLL Synthesizer를 이용한 새로운 FM 회로 설계 및 제작)

  • Yang, Seong-Sik;Lee, Jong-Hwan;Yeom, Kyung-Whan
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.224-228
    • /
    • 2003
  • In this paper, for phase lock loop(PLL) synthesizer, we introduce a novel but simple and low cost frequency modulation(FM) circuit of a flat peak frequency deviation for modulation signal from high to very low frequency penetrating into the loop-bandwidth of PLL. The FM circuit was basically designed to compensate an amount of feedback of the loop filter in PLL. The circuit also includes the capability of the adjustment of peak frequency deviation and blocking the interference with the loop filter. The designed circuit was successfully implemented and showed the flat frequency deviation as expected in the design.

  • PDF

Response Function of Temperature Fluctuation in the Poiseulle Flows (포와셀 관유동에서 온도변화의 응답특성)

  • 정진희
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.699-705
    • /
    • 2002
  • The present study discusses the deviation from the pure dead-time model of passive scalars such as temperature and concentration in the Poiseulle flow Even in the case of no thermal diffusion, there exists a substantial amount of damping and large deviation of phase lag from that computed by the traditional dead-time model after only 10 diameter downstream. These are caused by the phase difference of temperature in the radial direction due to the nonuniform velocity distribution. In the presence of thermal diffusion, damping is more pronounced.

An Analysis of Duration of Occlusal Sounds in TMD Patients (측두하악장애 화낮의 교합음 지속시간에 관한 분석)

  • Young-Mee Kwon;Jae-Kap Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.14 no.1
    • /
    • pp.9-17
    • /
    • 1989
  • The author has measured the duration of occlusal sounds during centric occlusal tapping in 30 patients with TMD and 30 normal subjects as controls, and then correlated the duration of occlusal sounds with CMI, amount of centric slide, midline deviation, habitual side of mastication, and presence of occlusal interference. The results were as follows 1. The duration of occlusal sounds during centric occlusal tapping were 36.26 msec in TMD patients and 22.8 msec in normal subjects (p<0.01). 2. The correlation between duration of occlusal sounds and CMI was significant (p<0.01). 3. The correlations between duration of occlusal sounds with amount of centric slide, midline deviation, habitual side of mastication, and presence of occlusal interference were not significant (p<0.05).

  • PDF

Design and Implementation of a Novel Frequency Modulation Circuit using Phase Locked Loop Synthesizer (PLL 주파수 합성기를 이용한 새로운 주파수 변조 회로 설계 및 제작)

  • 양승식;이종환;염경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.599-607
    • /
    • 2004
  • In this paper, using phase locked loop(PLL) synthesizer, we introduce a novel but simple and low cost frequency modulation(FM) circuit of a flat peak frequency deviation fur modulation signal whose frequency covers from outside to inside of the loop-bandwidth of PLL. The FM circuit was basically designed to compensate an amount of feedback of the loop filter in PLL. The circuit also includes the capability of the adjustment of peak frequency deviation and of blocking the intereference with the loop filter. The designed circuit was successfully implemented and showed the flat frequency deviation as expected in the design. In addition, the novel measurement method of the wideband FM modulation index is suggested verified With the suggest measurement, it can be successfully shown the designed circuit has the expected frequency deviation.

A Study on the Analysis of Gel Images of Genes and Molecules (유전자 및 물질의 젤 영상 분석에 관한 연구)

  • 김영원;전병환
    • Proceedings of the IEEK Conference
    • /
    • 2001.06c
    • /
    • pp.33-36
    • /
    • 2001
  • With all the researches to define human genom and to look for some new bio-activated material in the bio-technology field recently, it is more highly needed to analyse DNA or so called Material than ever before. First, the lanes are extracted based on histogram analysis and projection technique. And then three other approaches are applied for band extraction: SB, RG-1, and RG-2. In SB method, a search line is set dividing each lane equally and vertically to find peaks and valleys. And according to them, minimum enclosing rectangle of each band is determined. In RC-1 approach, on the other hand, band areas are extracted by region growing with the peaks as seeds, avoiding the overlap with the neighboring bands. In RC-2 approach, peaks and valleys are searched in two lines that trisect the lane vertically, and the pair of peaks in the same band are determined, and then used to grow the region. To compare the accuracy of the three suggested methods, we measure the location and amount of bands. The result shows that the mean deviation of the location is 0.06, 0.03, and 0.01 for SB, RG-1, and RC-2 respectively. And the mean deviation of the amount of bands is 0.08, 0.05, and 0.02 for SB, RG-1, and RG-2 respectively. In conclusion, the RG-2 method suggested in this paper appears to be the most reliable on the degree of the accuracy in measuring the location and amount of bands

  • PDF

Evaluation on the leakage of ground-water through fractured rock under a spillway (여수로 구조물 하부 암반 내 발달한 절리들을 통한 지하수 누수량 분석)

  • Kim, Hyoung-Soo;Lee, Ju-Hyun;Jeong, Ui-Jin;Lee, Joong-Woo
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.2
    • /
    • pp.129-134
    • /
    • 2006
  • Recently, spillways are need to control stable water level for supporting main dams because of floods by unusual change of weather such as Typhoon Rusa. This study has been focused on the amount of leakage through the rock mass distributed fractures and joints under the opened emergency spillway. It is very important to evaluate the amount of leakage as these affect stability of spillway by interaction between effective stress and pore pressure. The commercial program MAFIC has been used for analyzing groundwater flow in fractured rock mass. The results showed that the values of range, average and deviation of leakage were 2.85∼3.79×10-1, 3.32×10-1 and 1.70×10-2 m3/day/m2 respectively. Secondary, we have estimated the effect of grouting after the transmissivity(Tf) of joint 1 as main pathway of leakage known from above results was changed from 1.78×10-7 to 1.59×10-9 m2/s. The results showed that the values of range, average and deviation of leakage were 7.80×10-4∼1.53×10-3, 1.18×10-3 and 1.32×10-4 m3/day/m2 respectively. As the result, the amount of leakage after grouting has been decreased by a ratio of 1 to 277.

  • PDF

A Study on Verification of Shoe Last Grading System Based on Foot Measuring Data (발계측 자료에 기초한 신골 할출 시스템의 검증에 관한 연구)

  • Park, Hae-Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.71-77
    • /
    • 2007
  • Shoe's size and shape are determined by the last that takes shape of foot because last is the mold of shoe in development and manufacturing process. Then adaptation between foot and shoe is dependent on the last. In mass shoe production, model size is developed in the first place, other sized lasts are made through the grading process based on model size. The most important factor in grading system is grading deviation that must be same amount induced from foot measuring database. At present, most of the last manufacturing companies in korea using 260mm as a standard foot model size. When length grading deviation is 5mm, the ball girth grading deviation is 3.7mm and the ball width grading deviation is 1.2mm. I verified existing grading system by comparing grading results with foot measuring data. Also, I proposed reasonable grading deviation and application method of grading system. From the analysis of foot measuring database, reasonable grading deviations are 1.22mm in ball width and 0.84mm in ankle height in case of length grading deviation is 5mm. I confirmed that the current grading system is very accurate. When we grade last from 230mm to 290mm by current grading system based on model size 260mm, there is grading error over 1mm in the front outside area of foot. This error level of 1mm is no problem in normal walking shoe's last, but it induces adaptation problems in sports and special purposed shoe's last. Therefore using of three standard model size is recommended in grading men's last for reducing grading deviation error under the level of 1mm. It is specifically described as 235mm in 225-245mm, 260mm in 250-270mm, 285mm in 275-295mm. According to the above recommended grading system, it is enough to measure only three foot sizes in case of foot measuring project for men's last development.

Horizontal Effects of 10-mm Inferior Oblique Recession versus 14-mm Inferior Oblique Recession

  • Kim, Jae Min;Kim, Ungsoo Samuel
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.478-482
    • /
    • 2018
  • Purpose: The aim of this study was to investigate the quantitative effect of inferior oblique (IO) 10- and 14-mm recession on postoperative horizontal deviation. Methods: Patients (22 men and 18 women) who underwent IO recession were divided into two groups for comparison studies: group 1 (10-mm IO recession, 15 patients) and group 2 (14-mm IO recession, 25 patients). Preoperative and postoperative horizontal deviations were measured, and the resulting horizontal deviations from the 10- and 14-mm IO recession surgeries were compared. The effects of superior oblique underaction, IO overaction, and combined exodeviation on postoperative horizontal deviation were analyzed. Results: Although group 1 did not show a significant horizontal deviation change after surgery ($1.9{\pm}4.5$ prism diopters [PD], p = 0.452), group 2 had a meaningful horizontal change after 14-mm recession ($2.2{\pm}3.8PD$, p = 0.022). Both groups showed a significant esodrift in horizontal deviation (group 1, p = 0.017; group 2, p = 0.030) in patients with exodeviation over 8 PD. The mean change in horizontal deviation was $6.0{\pm}5.4PD$ for group 1 and $9.0{\pm}5.0PD$ for group 2. Although the amount of superior oblique underaction did not affect the extent of change in horizontal deviation, patients with severe IO overaction showed a significant change in horizontal deviation after 14-mm IO recession. Conclusions: Fourteen-millimeter IO recession could make a statistically significant change in horizontal deviation after surgery. In addition, esodrift should be considered after IO recession in patients with a preoperative exodeviation greater than 8 PD or severe IO overaction.

Surface Approximation Utilizing Orientation of Local Surface

  • Ko, Myeong-Cheol;Sohn, Won-Sung;Choy, Yoon-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.4
    • /
    • pp.698-706
    • /
    • 2003
  • The primary goal of surface approximation is to reduce the degree of deviation of the simplified surface from the original surface. However it is difficult to define the metric that can measure the amount of deviation quantitatively. Many of the existing studies analogize it by using the change of the scalar quantity before and after simplification. This approach makes a lot of sense in the point that the local surfaces with small scalar are relatively less important since they make a low impact on the adjacent areas and thus can be removed from the current surface. However using scalar value alone there can exist many cases that cannot compute the degree of geometric importance of local surface. Especially the perceptual geometric features providing important clues to understand an object, in our observation, are generally constructed with small scalar value. This means that the distinguishing features can be removed in the earlier stage of the simplification process. In this paper, to resolve this problem, we present various factors and their combination as the metric for calculating the deviation error by introducing the orientation of local surfaces. Experimental results indicate that the surface orientation has an important influence on measuring deviation error and the proposed combined error metric works well retaining the relatively high curvature regions on the object's surface constructed with various and complex curvatures.

  • PDF