• Title/Summary/Keyword: The White Noise

Search Result 1,074, Processing Time 0.025 seconds

Comparison of various structural damage tracking techniques based on experimental data

  • Huang, Hongwei;Yang, Jann N.;Zhou, Li
    • Smart Structures and Systems
    • /
    • v.6 no.9
    • /
    • pp.1057-1077
    • /
    • 2010
  • An early detection of structural damages is critical for the decision making of repair and replacement maintenance in order to guarantee a specified structural reliability. Consequently, the structural damage detection, based on vibration data measured from the structural health monitoring (SHM) system, has received considerable attention recently. The traditional time-domain analysis techniques, such as the least square estimation (LSE) method and the extended Kalman filter (EKF) approach, require that all the external excitations (inputs) be available, which may not be the case for some SHM systems. Recently, these two approaches have been extended to cover the general case where some of the external excitations (inputs) are not measured, referred to as the adaptive LSE with unknown inputs (ALSE-UI) and the adaptive EKF with unknown inputs (AEKF-UI). Also, new analysis methods, referred to as the adaptive sequential non-linear least-square estimation with unknown inputs and unknown outputs (ASNLSE-UI-UO) and the adaptive quadratic sum-squares error with unknown inputs (AQSSE-UI), have been proposed for the damage tracking of structures when some of the acceleration responses are not measured and the external excitations are not available. In this paper, these newly proposed analysis methods will be compared in terms of accuracy, convergence and efficiency, for damage identification of structures based on experimental data obtained through a series of laboratory tests using a scaled 3-story building model with white noise excitations. The capability of the ALSE-UI, AEKF-UI, ASNLSE-UI-UO and AQSSE-UI approaches in tracking the structural damages will be demonstrated and compared.

An analysis of the Sound Radiation Characteristics of the King Song-Dok Bell Using Cylindrical Acoustic Holography (원통형 음향 홀로그라피를 이용한 성덕대왕 신종의 방사음장 특성 분석)

  • Kim, Yang-Hann;Kim, Sea-Moon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.94-100
    • /
    • 1997
  • In order to investigate the radiation of sound from the King Song-Duk bell, we measured the sound pressure around the bell at every 30$^{\circ}$ using a microphone line array which was composed of 30 microphones separated by 15cm;total number of measurement point was 360. The sound field was estimated by using cylindrical acoustic holography. The spectrum of measured sound pressure demonstrates that it is almost like white noise in the very beginning, but in 10 seconds two close frequency components(64.06Hz, 64.38Hz) remain and make a famous beating. This beating sound is often believed to make unique sound of the King Song-Duk bell. The mode shapes of that frequency components are the same except that one is rotated by 45$^{\circ}$ from the other. This phenomenon occurs at the other pairs of components are the same except ones in very high frequency range where the mode shapes are rather complex.

  • PDF

The Effect of Adaptation to Sound Intensity on the Neural Metabolism in Auditory Pathway: Small Animal PET Study (소동물 [F-18]FDG 양전자단층촬영 기법을 이용한 청각신경에서의 소리크기에 대한 적응효과 연구)

  • Jang, Dong-Pyo
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.55-60
    • /
    • 2011
  • Although sound intensity is considered as one of important factors in auditory processing, its neural mechanism in auditory neurons with limited dynamic range of firing rates is still unclear. In this study, we examined the effect of sound intensity adaptation on the change of glucose metabolism in a rat brain using [F-18] micro positron emission tomography (PET) neuroimaging technique. In the experiment, broadband white noise sound was given for 30 minutes after the [F-18]FDG injection in order to explore the functional adaptation of rat brain into the sound intensity levels. Nine rats were scanned with four different sound intensity levels: 40 dB, 60 dB, 80 dB, 100 dB sound pressure level (SPL) for four weeks. When glucose uptake during the adaptation of a high intensity sound level (100 dB SPL) was compared with that during adaptation to a low intensity level (40 dB SPL) in the experiment, the former induced a greater uptake at bilateral cochlear nucleus, superior olivary complexes and inferior colliculi in the auditory pathway. Expectedly, the metabolic activity in those areas linearly increased as the sound intensity level increased. In contrast, significant decrease interestingly occurred in the bilateral auditory cortices: The activities of auditory cortex proportionally decreased with higher sound intensities. It may reflect that the auditory cortex actively down-regulates neural activities when the sound gets louder.

Systematic comparisons among OpenFAST, Charm3D-FAST simulations and DeepCWind model test for 5 MW OC4 semisubmersible offshore wind turbine

  • Jieyan Chen;Chungkuk Jin;Moo-Hyun Kim
    • Ocean Systems Engineering
    • /
    • v.13 no.2
    • /
    • pp.173-193
    • /
    • 2023
  • Reliable prediction of the motion of FOWT (floating offshore wind turbine) and associated mooring line tension is important in both design and operation/monitoring processes. In the present study, a 5MW OC4 semisubmersible wind turbine is numerically modeled, simulated, and analyzed by the open-source numerical tool, OpenFAST and in-house numerical tool, Charm3D-FAST. Another commercial-level program FASTv8-OrcaFlex is also introduced for comparison for selected cases. The three simulation programs solve the same turbine-floater-mooring coupled dynamics in time domain while there exist minor differences in the details of the program. Both the motions and mooring-line tensions are calculated and compared with the DeepCWind 1/50 scale model-testing results. The system identification between the numerical and physical models is checked through the static-offset test and free-decay test. Then the system motions and mooring tensions are systematically compared among the simulated results and measured values. Reasonably good agreements between the simulation and measurement are demonstrated for (i) white-noise random waves, (ii) typical random waves, and (iii) typical random waves with steady wind. Based on the comparison between numerical results and experimental data, the relative importance and role of the differences in the numerical methodologies of those three programs can be observed and interpreted. These comparative-study results may provide a certain confidence level and some insight of potential variability in motion and tension predictions for future FOWT designs and applications.

Seismic response of steel reinforced concrete spatial frame with irregular section columns under earthquake excitation

  • Xue, Jianyang;Zhou, Chaofeng;Liu, Zuqiang;Qi, Liangjie
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.337-347
    • /
    • 2018
  • This paper presents some shaking table tests conducted on a 1/4-scaled model with 5-story steel reinforced concrete (SRC) spatial frame with irregular section columns under a series of base excitations with gradually increasing acceleration peaks. The test frame was subjected to a sequence of seismic simulation tests including 10 white noise vibrations and 51 seismic simulations. Each seismic simulation was associated with a different level of seismic disaster. Dynamic characteristic, strain response, acceleration response, displacement response, base shear and hysteretic behavior were analyzed. The test results demonstrate that at the end of the loading process, the failure mechanism of SRC frame with irregular section columns is the beam-hinged failure mechanism, which satisfies the seismic code of "strong column-weak beam". With the increase of acceleration peaks, accumulated damage of the frame increases gradually, which induces that the intrinsic frequency decreases whereas the damping ratio increases, and the peaks of acceleration and displacement occur later. During the loading process, torsion deformation appears and the base shear grows fast firstly and then slowly. The hysteretic curves are symmetric and plump, which shows a good capacity of energy dissipation. In summary, SRC frame with irregular section columns can satisfy the seismic requirements of "no collapse under seldom earthquake", which indicates that this structural system is suitable for the construction in the high seismic intensity zone.

Amplitude dependency of damping of tall structures by the random decrement technique

  • Xu, An;Xie, Zhuangning;Gu, Ming;Wu, Jiurong
    • Wind and Structures
    • /
    • v.21 no.2
    • /
    • pp.159-182
    • /
    • 2015
  • This study focuses on the amplitude dependency of damping of tall structures by the random decrement technique (RDT). Many researchers have adopted RDT to establish the amplitude dependency of damping ratios in super-tall buildings under strong wind loads. In this study, a series of simulated examples were analyzed to examine the reliability of this method. Results show that damping ratios increase as vibration amplitudes increase in several cases; however, the damping ratios in the simulated signals were preset as constants. This finding reveals that this method and the derived amplitude-dependent damping ratio characteristics are unreliable. Moreover, this method would obviously yield misleading results if the simulated signals contain Gaussian white noise. Full-scale measurements on a super-tall building were conducted during four typhoons, and the recorded data were analyzed to observe the amplitude dependency of damping ratio. Relatively wide scatter is observed in the resulting damping ratios, and the damping ratios do not appear to have an obvious nonlinear relationship with vibration amplitude. Numerical simulation and field measurement results indicate that the widely-used method for establishing the amplitude-dependent damping characteristics of super-tall buildings and the conclusions derived from it might be questionable at the least. More field-measured data must be collected under strong wind loads, and the damping characteristics of super-tall buildings should be investigated further.

Effects of Design Factors of the Instrument Cluster Panel on Consumers' Affection Applying Robust Design (강건 설계기법을 이용한 자동차 게이지 클러스터의 디자인 요소와 고객 감성에 관한 연구)

  • Jung, Ga-Hun;Park, Sung-Joon;Kim, Seong-M.;Jung, Eui-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.25-31
    • /
    • 2010
  • It is known from consumer surveys that the interior design of cars greatly influences on consumers' affection. Most notably, the instrument panel which occupies the driver's attention while driving would be one of the main components that affect consumer's affection, but the designer does not often put due importance to this design component. The purpose of this study is to define consumers' affection on the instrument cluster panel in terms of its design factors: color of panel lighting and layout of meters as independent factors. Semantic differentials or affective adjectives that are related to the instrument panel were first derived from surveys, existing studies and the available literature. Then, representative affective factors were drawn using factor analysis and multi-dimensional scaling (MDS). Evaluation of the instrument panel was performed and analyzed by Taguchi's robust design to provide more robust results under various noise factors which are color and material of car interior. Experiment revealed that consumers had five affective factors on the instrument panel and luxurious, charming, and visible affections are grouped into a factor and unique and dynamic affections in another factor. Evaluation of the instrument panel by Taguchi's robust design found that the white color of panel lighting and the panel with four meters was the most preferred design in terms of both the affection of luxury and uniqueness.

A Study on Interference Cancelling Receiver with Adaptive Blind CMA Array (적응 블라인드 CMA 어레이를 이용한 간섭 제거 수신기에 관한 연구)

  • 우대호;변윤식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4A
    • /
    • pp.330-335
    • /
    • 2002
  • In the direct sequence code division multiple access system, the problem of multiple access interference due to multiple access is generated. A interference cancelling receiver is used to solve this problem. The conventional interference cancelling receiver is structure of successive interference canceller using antenna array. In this structure, the difference of between method I and method II depends on updating weight vector. In this paper, the adaptive blind CMA array interference cancelling receiver using cost function of constant modulus algorithms is proposed to update weight vector at conventional structure. The simulation compared the proposed interference cancelling receiver with two conventional interference cancelling receivers by signal to interference ratio and bit error rate curve under additive white Gaussian noise environment. The simulation results show that the proposed receiver has about the gain of SIR of 1.5[dB] more than method I which is conventional receiver at SIR curve, and about the gain of SIR of 0.5(dB) more than method II. In BER curve, the proposed IC receiver about the gain of SNR of 2[dB] more than method I and about the gain of SNR of 0.5[dB] more than method If, Thus, the proposed interference cancelling receiver has the higher performance than conventional interference cancelling receivers.

Improvement of Color Quality of Flash Images Utilizing the Same-Scene No-Flash Images (동일 장면 비-플래쉬 영상을 이용한 플래쉬 영상의 색상 개선)

  • Chang, Ho-Seok;Lim, Jin-Young;Jung, Kyeong-Hoon;Kim, Ki-Doo;Kang, Dong-Wook
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.760-770
    • /
    • 2008
  • Though flash images are in general less noisy and present details better than no-flash images, they may sometimes be unnaturally saturated to white/gray-tone and have ridiculously strong shadows around the foreground objects due to the strong flashlight. In this paper, we propose a new algorithm to improve the color quality of the flash images by transfer of the color information of the same-scene no-flash images. The proposed algorithm preserves the vivid edges and the clean details of the flash image while transferring natural colors of the no-flash image, so that it makes the constructed images of the better subjective quality. The performance of the proposed algorithm is verified by experiment which applied to the two types of images with different noise levels.

Estimation of GPS Holdover Performance with Ladder Algorithm Used for an UFIR Filter (UFIR 필터 Ladder 알고리즘 이용 GPS Holdover 성능 추정)

  • Lee, Young-kyu;Yang, Sung-hoon;Lee, Chang-bok;Heo, Moon-beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.669-676
    • /
    • 2015
  • In this paper, we described the simulation results of the phase offset performance of a clock in holdover mode which was normally operated in GPS Disciplined Oscillator (GPSDO). In the TIE model, we included the time error term caused by environmental temperature variation because one of the most important parameters of clock phase error is the frequency offset and drift caused by the variation of temperature. For the simulation, we employed Maximum Time Interval Error (MTIE) for the performance evaluation when the frequency offset and drift are estimated by using an Unbiased Finite Impulse Response (UFIR) filter with ladder algorithm. We assumed that the noise in the GPS measurement is white Gaussian with zero mean and 1 ns standard deviation, and temperature linearly varies with a slope of $1{^{\circ}C}$ per hour. From the simulation results, the followings were observed. First, with the estimation error of temperature of less than 3 % and the temperature compensation period of less than 900 seconds, the requirement of CDMA2000 phase synchronization under 10 us could be achieved for more than 40,000 seconds holdover time if we employ an OCXO (Oven Controlled Crystal Oscillator) clock. Second, in order to achieve the requirement of LTE-TDD under 1.5 us for more than 10,000 seconds holdover time, below 3 % estimation error and 500 seconds should be retained if a Rubidium clock is adopted.