• Title/Summary/Keyword: The Type of Linkage

Search Result 338, Processing Time 0.03 seconds

Measurement of Engine Piston Temperature Distribution by Using Scissors-type Linkage System (가위형 링크 기구를 이용한 기관의 피스톤 온도 분포 측정)

  • 김재업;이종화;김세웅;김응서
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.69-76
    • /
    • 1993
  • The program for the development of linkage system was made and the scissors-type linkage system was designed. The piston temperature distribution under steady state was measured by the linkage system and thermocouple. The effects of engine speed, coolant outlet temperature, and torque on the piston temperature were investigated.

  • PDF

평면 캠-링크 기구의 설계 소프트웨어 개발

  • 양현익;유호윤
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.788-793
    • /
    • 1995
  • For a linkage mechanism deiven by cam, cam profile is the major design factor and is determined by the motion type od cam follower. If a cam mechanism has additional kinematic linkages besides cam and follower then the follower motion should be specified form the motion of end linkage member so that cam would be able to generate the desired end linkage motion. In this paper, a cam-linkage mechanism is constructed with the combinations of modular linkage elements including cam and follower and as a resullt, a planar cam-linkage mechanism design software with the cam profile optimization function is developed and presented.

  • PDF

A Study on the Linkage for National Geographic Information Clearinghouse (국가지리정보유통망과 계열 유통망의 연계에 관한 연구)

  • 신동빈;김수현
    • Spatial Information Research
    • /
    • v.11 no.4
    • /
    • pp.453-464
    • /
    • 2003
  • The Competitive power of the country in knowledge information can be determined that how efficiently useful knowledge and information can be circulated. Korean government established the second National GIS Master Plan, and constructed National Geographic Information Clearinghouse to the goal 'whole nation's internet circulation of the geographic information and practical use'. But every departments of government are trying to circulate their geographic information individually, And this case, consumer group should approach to several dissemination network in various routing line to get the geographic information. In fact, it is difficult to present the solution for uilified single dissemination network. It is difficult to present suitable linkage plan coinciding in special environment and characteristics of all systems. Consequently, in this study, we suggested linkage element that should consider far link with National Geographic Information Clearinghouse, and presented linkage plan by linkage target type.

  • PDF

Spring Connected Size-Variable Rigid Block Model for Automatic Synthesis of a Planar Linkage Mechanism (평면 링크기구 자동 설계를 위한 스프링 연결 사이즈 가변 블록 모델)

  • Kim, Bum-Suk;Yoo, Hong-Hee
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.822-826
    • /
    • 2008
  • A linkage mechanism is a device to convert an input motion into a desired output motion. Traditional linkage mechanism designs are based on trial and error approaches so that size or shape changes of an original mechanism often result in improper results. In order to resolve these problems, an improved automatic mechanism synthesis method that determines the linkage type and dimensions by using an optimization method during the synthesis process has been proposed. For the synthesis, a planar linkage is modeled as a set of rigid blocks connected by zero-length translational springs with variable stiffness. In this study, the sizes of rigid blocks were also treated as design variables for more general linkage synthesis. The values of spring stiffness and the size of rigid block yielding a desired output motion at the end-effecter are found by using an optimization method.

  • PDF

Conformation and Linkage Studies of Specific Oligosaccharides Related to H1N1, H5N1, and Human Flu for Developing the Second Tamiflu

  • Yoo, Eunsun
    • Biomolecules & Therapeutics
    • /
    • v.22 no.2
    • /
    • pp.93-99
    • /
    • 2014
  • The interaction between viral HA (hemagglutinin) and oligosaccharide of the host plays an important role in the infection and transmission of avian and human flu viruses. Until now, this interaction has been classified by sialyl(${\alpha}2-3$) or sialyl(${\alpha}2-6$) linkage specificity of oligosaccharide moieties for avian or human virus, respectively. In the case of H5N1 and newly mutated flu viruses, classification based on the linkage type does not correlate with human infection and human-to-human transmission of these viruses. It is newly suggested that flu infection and transmission to humans require high affinity binding to the extended conformation with long length sialyl(${\alpha}2-6$)galactose containing oligosaccharides. On the other hand, the avian flu virus requires folded conformation with sialyl(${\alpha}2-3$) or short length sialyl(${\alpha}2-6$) containing trisaccharides. This suggests a potential future direction for the development of new species-specific antiviral drugs to prevent and treat pandemic flu.

High-Performance Damping Device for Suppressing Vibration of Stay Cable (사장 케이블 제진을 위한 고성능 감쇠 장치)

  • Jung Hyung-Jo;Park Chul-Min;Jang Ji-Eun;Park Kyu-Sik;Lee In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.489-496
    • /
    • 2005
  • In this paper, the feasibility of the high-performance damping device vibration suppression of stay cables has been investigated. The proposed damping system consists of a linear viscous damper and a scissor-jack-type toggle linkage. Since the mechanism of the scissor-jack-type toggle linkage amplifies the relative displacement of the linear viscous damper, it is expected that the capacity of the viscous damper used in the scissor-jack-damper energy dissipation system can be reduced without the loss of the control performance. Numerical simulation results demonstrate the efficacy of the damping system employing the scissor-jack-type toggle linkage. Therefore, the proposed damping system could be considered as one of the promising candidates for suppressing vibration of stay cable.

  • PDF

Kinematic Modeling of Distal Radioulnar Joint for Human Forearm Rotation (인간의 전완 회전을 위한 원위 요척골 관절의 기구학적 모델링)

  • Yoon, Dukchan;Lee, Geon;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.4
    • /
    • pp.251-257
    • /
    • 2019
  • This paper presents the kinematic modeling of the human forearm rotation constructed with a spatial four-bar linkage. Especially, a circumduction of the distal ulna is modeled for a minimal displacement of the position of the hand during the forearm rotation from the supination to the pronation. To establish its model, four joint types of the four-bar linkage are, firstly, assigned with the reasonable grounds, and then the spatial linkage having the URUU (Universal-Revolute-Universal-Universal) joint type is proposed. Kinematic analysis is conducted to show the behavior of the distal radio-ulna as well as to evaluate the angular displacements of all the joints. From the simulation result, it is, finally, revealed that the URUU spatial linkage can be substituted for the URUR (Universal-Revolute-Universal-Revolute) spatial linkage by a kinematic constraint.

Development of 4-Bar Linkage Orthotic Knee Joint (4절 연쇄 보조기무릎관절의 개발)

  • Kim, Jang-Hwan;Yi, Jin-Bock
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.317-325
    • /
    • 2011
  • This study aims to develop the stance-control typed 4-bar linkage orthotic knee joint that replace the locked orthotic knee joint for the disabled with poliomyelitis and muscle weakness of lower limb. Unlike the existing stance-control orthotic knee joint, there are no needs of electric power, connecting circuit, bulky compomnets, etc, because this 4-bar linkage orthotic knee joint is controled by geometric locking. To evaluate the 4-bar linkage orthotic knee joint, a subject participated in this study who has been diagnosed with lower limb poliomyelitis and have used locked type orthotic knee joint. In the results of analysis of subject's gait using 3-dimentional motion analysis system, this 4-bar linkage orthotic knee joint provide the stability during stance phase and knee flexion during swing phase.

THE EFFECTS OF POPULATION SIZE AND DOMINANCE OF QUANTITATIVE TRAIT LOCI (QTL) ON THE DETECTION OF LINKAGE BETWEEN MARKERS AND QTL FOR LIVESTOCK

  • Jeon, G.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.6
    • /
    • pp.651-655
    • /
    • 1995
  • A simulation study on detection of linkage between genetic markers and QTL in backcross design was conducted. The effects of various sample sizes and the degree of QTL dominance on detention of linkage were examined by using a simple regression analysis. The results indicated that as sample size increased, the standard error of the estimated slope became smaller. When the dominance effect of QTL was complete, the estimated slope tended to be negative but was statistically not significant at all with type I error of greater than 50%. With complete linkage between genetic Marker and QTL, the estimated intercept value was smallest but the estimated slope was largest as expected. In most cases with various degree of dominance and sample sizes, when the actual recombination rate became larger, greater values were obtained for the slope except in the case of complete dominance of QTL.

Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis (소아마비에서 4절 연쇄 장하지보조기 사례연구)

  • Kim, Jang-Hwan;Kwon, Oh-Yun;Yi, Chung-Hwi;Cho, Sang-Hyun;Cynn, Heon-Seock;Choi, Heung-Sik
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.