• Title/Summary/Keyword: The Height of Building

Search Result 1,088, Processing Time 0.026 seconds

The Preliminary Design Guideline for Tall Building: Exploration of Planning Factors & Building Factors

  • Choi, Yong Sun
    • Architectural research
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • Every year new tall buildings are being conceived, designed, and built with new schemes. Thus it is important to explore the factors that affect tall building design. Thus it is important to explore the tall building design factors. The planning and design of tall buildings require different criteria than those that exist in regular size buildings. Tall buildings are uniquely expressed by their structural systems where exterior esthetic and requirements of space drive the form and composition of the structural systems. Therefore the exploration of design factors is the key to achieve optimum building systems. Optimization as mentioned here is associated with the efficiency of the different building systems. To achieve an optimal system, there is a need for an understanding of the factors that affect on overall tall building design such as planning module, building function, lease span, floor-to-floor-height, building height (aspect ratio), structural system, environmental systems. In this paper a statistical approach will be used and will be based on data collected from the practice through a rigorous survey taken. This information is tabulated and analyzed. The major target of investigation will be lease span related to space requirement in the tall building planning. Factors related to lease spans, such as function, floor-to-floor height, planning module, building height, overall plan dimension, and plan ratio (building geometry), will be looked at carefully. IN conclusion, this approach of optimization can introduce a preliminary design guideline for tall building projects. The purpose of the paper should shed some light on the optimum tall building design criteria.

A Semi-automated Method to Extract 3D Building Structure

  • Javzandulam, Tsend-Ayush;Kim, Tae-Jung;Kim, Kyung-Ok
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.3
    • /
    • pp.211-219
    • /
    • 2007
  • Building extraction is one of the essential issues for 3D city modelling. In recent years, high-resolution satellite imagery has become widely available and it brings new methodology for urban mapping. In this paper, we have developed a semi-automatic algorithm to determine building heights from monoscopic high-resolution satellite data. The algorithm is based on the analysis of the projected shadow and actual shadow of a building. Once two roof comer points are measured manually, the algorithm detects (rectangular) roof boundary automatically. Then it estimates a building height automatically by projecting building shadow onto the image for a given building height, counting overlapping pixels between the projected shadow and actual shadow, and finding the height that maximizes the number of overlapping pixels. Once the height and roof boundary are available, the footprint and a 3D wireframe model of a building can be determined. The proposed algorithm is tested with IKONOS images over Deajeon city and the result is compared with the building height determined by stereo analysis. The accuracy of building height extraction is examined using standard error of estimate.

Pounding between adjacent buildings of varying height coupled through soil

  • Naserkhaki, Sadegh;El-Rich, Marwan;Aziz, Farah N.A. Abdul;Pourmohammad, Hassan
    • Structural Engineering and Mechanics
    • /
    • v.52 no.3
    • /
    • pp.573-593
    • /
    • 2014
  • Pounding between adjacent buildings is a significant challenge in metropolitan areas because buildings of different heights collide during earthquake excitations due to varying dynamic properties and narrow separation gaps. The seismic responses of adjacent buildings of varying height, coupled through soil subjected to earthquake-induced pounding, are evaluated in this paper. The lumped mass model is used to simulate the buildings and soil, while the linear visco-elastic contact force model is used to simulate pounding forces. The results indicate while the taller building is almost unaffected when the shorter building is very short, it suffers more from pounding with increasing height of the shorter building. The shorter building suffers more from the pounding with decreasing height and when its height differs substantially from that of the taller building. The minimum required separation gap to prevent pounding is increased with increasing height of the shorter building until the buildings become almost in-phase. Considering the soil effect; pounding forces are reduced, displacements and story shears are increased after pounding, and also, minimum separation gap required to prevent pounding is increased.

A Study on the Height Limitation of a Building in Building Law - Focusing on the Standard of the Ground Level Calculation - (건축법(建築法)에서의 건축물(建築物) 높이제한규정(制限規定) - 지표면산정기준(地表面算定基準)을 중심(中心)으로 -)

  • Kim, Soo-Young
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.1
    • /
    • pp.29-38
    • /
    • 2003
  • The articles on building height limitation are very important to form buildings to be. The application of the articles is based on the surface of the building site ground, that is, the definite judgment of ground level should ensure the correctness of building height limitation. This study surveyed the recognition degree of practitioners about the building height limitation regulations by questionnaires, and analyzed its results and compared them to related building laws and letter of reply from the office to practitioners' inquiry on related regulation. The study summarized the results as follows; 1. It is not clear to judge the ground level. Especially in cases of pilotis structure, there would be various interpretations to define its ground level. 2. According to present building regulations, the site would be confused to define by practitioners whether it is stiff or plain. 3. In case of regulation of a right to enjoy sunshine, it is hard to calculate the average horizontal level(ground level) with neighboring sites. 4. If there were a manual with illustrations for judging and calculating the ground level of various cases, civil petitions would be reduced.

  • PDF

A Study on the Building Height Estimation and Accuracy Using Unmanned Aerial Vehicles (무인비행장치기반 건축물 높이 산출 및 정확도에 관한 연구)

  • Lee, Seung-weon;Kim, Min-Seok;Seo, Dong-Min;Baek, Seung-Chan;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.2
    • /
    • pp.79-86
    • /
    • 2020
  • In order to accommodate the increase in urban population due to government-led national planning and economic growth, many buildings such as houses and business building were supplied. Although the building law was revised and managed to manage the supplied buildings, for the sake of economic benefit, there have been buildings that are enlarged or reconstructed without declaring building permits. In order to manage these buildings, on-site surveys were conducted. but it has many personnel consumption. To solve this problem, a method of using a satellite image and a manned aircraft is utilized, but it is diseconomical and a renewal cycle is long. In addition, it is not utilized to the height, and although it is judged by the shading of the building, it has limitations that it must be calculated individually. In this study, height of the building was calculated by using the unmanned aerial vehicle with low personnel consumption, and the accuracy was verified by comparison with the building register and measured value. In this study, spatial information was constructed using a fast unmanned aerial vehicle with low manpower consumption and the building height was calculated based on this. The accuracy by comparing the calculated building height with the building register and the actual measurement.

Effect of the building envelope on heating and cooling load in super tall building considering the meteorological changes with height (높이별 기상변화를 고려한 초고층 건축물의 외피종류별 냉난방 부하특성 분석)

  • Choi, Jong-Kyu;Kim, Yang-Soo;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.337-344
    • /
    • 2012
  • Today, the number of super tall buildings are under construction or being planed in Middle East and Asian Countries. For example the burj Khalifa, the tallest building in the world, is completed in 2008 and the height of that is about 800m. Also, Lotte World Tower is under construction in Korea. External environmental conditions such as wind speed, air temperature, humidity and solar radiation around the super tall building differs according to the building height due to the vertical micro climate change. However, the meteorological information used for AC design of building is obtained typically from standard surface meterological station data(~2m above the ground). In this paper the effect of the building envelope on heating and cooling load in super tall building considering the meteorological changes with height was analyzed with simulation method. As results of this research, the guideline to select the building envelop alternatives for super tall building will be suggested in this paper.

  • PDF

Extraction of Building Height Using Digital Map and Single Imagery (수치지도와 단영상을 이용한 건물의 고도값 추출)

  • Yun Kong-Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.1
    • /
    • pp.57-64
    • /
    • 2006
  • Recently the extraction of building height information has been investigated using remotely sensed image and digital maps. In this study, based on the digital photogrammetry principle and mono imagery method the building height information can be extracted by using relationship between ground coordinates and image coordinates. To evaluate the result the comparison was done with building height from 1:5000 aerial photo. The experiment shows that extraction of building height could be performed using IKONOS single imagery and digital map and it is proved that the building height could be reconstructed within some extent.

Extraction of Building Height Using correlation of Digital Map and Single Imagery (단영상과수치지도의상관관계를이용한건물의고도값추출)

  • Yeu Bock-Mo;Hong Jea-Min;Kim Min-Gu
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2006.05a
    • /
    • pp.138-145
    • /
    • 2006
  • Recently the extraction of building height information has been investigated using remotely sensed image and digital maps. In this study, based on the digital photogrammetry principle and mono imagery method the building height information can be extracted by using relationship between ground coordinates and image coordinates, To evaluate the result the comparison was done with building height from 1:5000 aerial photo. The experiment shows that extraction of building height could be performed using IKONOS single imagery and digital map and it is proved that the building height could be reconstructed within some extent.

  • PDF

A Study on Present Condition and Adjustment of the Minmium Height Regulation District in Busan Metropolitan City (부산시 최저고도지구 실태 및 기준조정에 관한 연구)

  • Lee, Dong-Hyun;Baek, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.51-60
    • /
    • 2008
  • The Purpose of this study is to find the adjustment of the minimum height regulation district in Busan metropolitan city. For this purpose, data of buildings in the minimum height regulation district are collected and analysed. Especially, detailed data of buildings in CBD are analysed. The results of this study provide that CBD's average building height is the fourth floor and the ratio that a building less than the fourth floor holds in total building is 51%. In the case of central area, CBD's building height should be maintained and it is necessary to make the policy that reinforce limited height for the high land use and landscape management. Based on these findings this study suggests that the limit building height should put it up more than the seventh floor.

  • PDF

A Study on the Impact Factor of Sunlight and View by Apartment Building in its Neighboring Area (focused on the variation of building height) (공동주택에 의한 인접지역의 일조 및 조망 영향에 관한 연구 - 건물 높이 변화를 중심으로 -)

  • 김용이;최정민
    • Journal of the Korean housing association
    • /
    • v.14 no.6
    • /
    • pp.51-58
    • /
    • 2003
  • When apartment buildings are builed and re-builded, they tends to be taller. This tendency causes the problems for solar access and view in the neighboring area. So the impact factor of sunlight and view by apartment building in its neighboring area is examined. The results of this study are as follows: When analyzing sky view by dividing the sky vault into the differential area, the analysis of view can be efficient. The shorter the apartment building, the more the continuous solar access time. And the taller the building, the more the accumulated solar access time. As the height of building is taller and it is farther from the border of apartment building, view ratio, sky view ratio, and form ratio are increased. It implies that the slimmer the building, the more the visual environment can be improved.