• Title/Summary/Keyword: The Environmental Test

Search Result 10,359, Processing Time 0.039 seconds

The Effect of Balance Training and environmental enrichment on motor performance after Traumatic Cerebellar Injury in the Rat (균형훈련과 환경강화가 외상성 소뇌 손상 흰쥐의 운동 수행력에 미치는 영향)

  • Song Ju-min;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.72-89
    • /
    • 2004
  • The purposes of this study were to test the effect of balance training and environmental enrichment on motor performance after traumatic cerebellar injury in the rat. Traumatic cerebellar injury was induced by weight drop model and after operation they were housed in individual standard cages for 24 hours. Twenty two Sprague-Dawley rats were randomly assigned into control and experimental groups. The control group was housed in standard cage for 7 days. The experimental group I was housed in standard cage after balance training for 7 days. The experimental group II was housed in environmental enrichment cage after balance training for 7 days. Vestibular drop test and tilting plane test was examined at preoperation, on 1st day after operation and 7th day after operation to the rats. The results of this experiment were as follows: 1. In motor behavioral test, at preoperation and on 1 day after operation, the outcomes were not different among the groups. But on 7th day after operation, the outcomes of group I were better than that in control group, and group II were better than group I. These results suggest that behavioral motor outcome by simultaneously application of balance training and environmental enrichment in traumatic cerebellar injured rats were more improve than that by just balance training.

  • PDF

Design and Performance Test of Cooling-Air Test Equipment for the Environmental Control System in Aircraft (항공기 ECS 냉각공기 시험장비 설계 및 성능 시험)

  • So, Jae-uk;Kim, Jin-sung;Kim, Jae-woo;Kim, Jin-bok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.2
    • /
    • pp.147-154
    • /
    • 2021
  • In this paper, the configuration and design of the test equipment are presented to examine the impact of rapid temperature change in cooling-air that may occur during the operation of the fixed wing aircraft Environmental Control System (ECS) on avionic electronic equipment. At the start of the ECS, the temperature of the air supplied by the aircraft ECS may be increased to 5.0℃ per second. In order to ensure operating of the avionic electronic equipment that is mounted on the aircraft and receives cooling-air from the ECS, testing equipment that can implement the cooling-air characteristic test environment is required. During design of test equipment was verified cooling-air rapid rate of temperature change by performing a thermal/flow analysis, performance of the test equipment implemented was verified by applying an avionic electronic equipment.

Effect of arbitrarily manipulated gap-graded granular particles on reinforcing foundation soil

  • Xin, Zhen H.;Moon, Jun H.;Kim, Li S.;Kim, Kab B.;Kim, Young U.
    • Geomechanics and Engineering
    • /
    • v.17 no.5
    • /
    • pp.439-444
    • /
    • 2019
  • It is generally known that high strength soil is indicative of well-graded particle size distribution. However, there are some special cases of firm ground despite poor grade distribution, especially a specific gap-graded soil. Based on these discoveries, this study investigated the development of an additive of gap-graded soils designed to increase soil strength. This theoretical concept was used to calculate the mixed ratio required for optimal soil strength of the ground sample. The gap-graded aggregate was added according to Plato's polyhedral theory and subsequently calculated ratio and soil strength characteristics were then compared to characteristics of the original soil sample through various test results. In addition, the underground stress transfer rate was measured according to the test conditions. The test results showed that the ground settlement and stress limit thickness were reduced with the incorporation of gap-graded soil. Further field tests would confirm the reproducibility and reliability of the technology by using gap-graded soil to reinforce soft ground of a new construction site. Gap-graded soil has the potential to reduce the construction cost and time of construction compared to other reinforcing methods.

Study on Environmental Resistance of Railway Transponder Tag for Wayside Installation (철도교통 트랜스폰더 태그의 선로변 설치를 위한 내환경성 연구)

  • Kim, Hye Yun;Park, Sungsoo;Yang, Youngoo;Lee, Seung Won;Youm, Ki Jung;Lee, Jae-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.948-953
    • /
    • 2015
  • In this paper, we studied the environmental requirements for the railway transponder system. The transponder system is comprised of a reader installed beneath the train, a tag installed on the track, and a portable programmer. Among them, the transponder tag should be designed to withstand harsh environments, such as wide operating temperature range, mechanical shock and vibration, etc. To validate stable and reliable service under railway conditions, we carried out environmental test for transponder tag. We then installed the tags on the Honam high-speed test line.

ENVIRONMENTAL FATIGUE OF METALLIC MATERIALS IN NUCLEAR POWER PLANTS - A REVIEW OF KOREAN TEST PROGRAMS

  • Jang, Changheui;Jang, Hun;Hong, Jong-Dae;Cho, Hyunchul;Kim, Tae Soon;Lee, Jae-Gon
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.929-940
    • /
    • 2013
  • Environmental fatigue of the metallic components in light water reactors has been the subject of extensive research and regulatory interest in Korea and abroad. Especially, it was one of the key domestic issues for the license renewal of operating reactors and licensing of advanced reactors during the early 2000s. To deal with the environmental fatigue issue domestically, a systematic test program has been initiated and is still underway. The materials tested were SA508 Gr.1a low alloy steels, 316LN stainless steels, cast stainless steels, and an Alloy 690 and 52M weld. Through tests and subsequent analysis, the mechanisms of reduced low cycle fatigue life have been investigated for those alloys. In addition, the effects of temperature, dissolved oxygen level, and dissolved hydrogen level on low cycle fatigue behaviors have been investigated. In this paper, the test results and key analysis results are briefly summarized. Finally, an on-going test program for hot-bending of 347 stainless steel is introduced.

Adsorption Characteristics of Granular Activated Carbon Filter Used for Drinking Water Purifier (정수기용 입상활성탄소 필터의 흡착특성에 관한 고찰)

  • Baek, Young-Man;Park, Je-Chul;Kim, Hyung-Jin
    • Journal of Environmental Science International
    • /
    • v.17 no.8
    • /
    • pp.899-905
    • /
    • 2008
  • Quality test for activated carbon(AC) filter used for drinking water purifier is now an obligatory test and the standard material for valid purifying amount in water purifier performance test has been changed from residual chlorine to chloroform according to the notice of Ministry of Environment in 2006. Therefore, this study aimed to compare the ingredients of AC filters by confirming chloroform removal rate of AC filter and conducting 4 adsorption tests (Iodine, methylene blue decolorization, phenol value, ADS value) for AC filters provided by manufacturers. With water pressure of $1kgf/cm^2$, 1,500 liters of prepared inflow went through to check chloroform removal rate. As a result, product with removal rate of below 60% from all products. On the other hand, 4 adsorption tests were conducted for filters in the market and filters from manufacturers. None of the products satisfied all 4 tests. In particular, they showed great shortage to the standard in phenol value and ADS value test. However, manufacturers' filter showed much better performance than filters in the market. Also, the result of valid purifying amount test for each of five products of appropriate product and inappropriate product based on filter quality test showed average 4,440 liters for appropriate product and average 2,620 liters for inappropriate product. According to the result, it is shown that the filter with good adsorption also had good chloroform removal efficiency and adsorption efficiency. Therefore, it is expected that customers can screen good quality product through obligatory conduct of filter quality test. However, it is considered that complementation in system is required for future inspection.

Comparative Study on Red Blood Cell Hemolysis and Yeast Test by Photosensitizing Compounds (광예민성화합물에 의한 적혈구 용혈현상과 Yeast 시험 비교연구)

  • 김봉희;백광흠
    • Environmental Analysis Health and Toxicology
    • /
    • v.5 no.1_2
    • /
    • pp.45-50
    • /
    • 1990
  • In order to investigate the phototoxicity of five phenothiazine derivatives and one thioxanthen derivative were examined by using in vitro method based on growth inhibition of Candida albicans and red blood cell hemolysis. Effects of the test compounds on RBCs were monitored with a spectrophotometer and a drug PI in the Candida albicans was calculated on the basis of the lowest concentration giving a yeast-free zone. All phenothiazines phototoxic in the red blood cell hemolysis method were positive in the yeast test except promethazine. It was also observed that toxic photo-products were formed by perphenazine and chlorpromazine in the red blood cell hemolysis.

  • PDF

A Serological Test for Syphilis among Prostitutes by VDRL Slide Test (VDRL Slide Test에 의한 접대부의 매독혈청검사 성적)

  • 김영의;김경준
    • Journal of Environmental Health Sciences
    • /
    • v.1 no.1
    • /
    • pp.18-20
    • /
    • 1974
  • A Serological test for Syphilis by VDRL Slide tests were made to find the degree of treponemal infection. For this study sera were collected from 5, 312 Prostitutes of Seoul, Inchun, Euijungbu, Yangzoo, Pajoo and Pyungtaig from November 27, to December 7, 1972 and were examined on the following items. 1. VDRL Slide Qualitative test. 2. VDRL Slide Quantitative test. As the results of this study the following Conclusions were obtained. 1) This test were obtained average reactive 5.92% for 5, 312 prostitutes in Seoul 7.87% for 254 prostitutes, in Iuchun 6.77% for 354 prostitutes, in Euijungbu 6.62% for 740 prostitutes, in Yangjoo 5.82% for 1, 958 prostitutes, in Pajoo 6.08% for 937 prostitutes and in Pyungtaig 4.82% for 1, 069 prostitutes respectively 2) The highest Reagin titer was 1: 32 serum dilution.

  • PDF

Evaluation of performance of closed-loop vertical ground heat exchanger by In-situ thermal response test (현장 열응답 시험을 통한 수직 밀폐형 지중열교환기의 성능 평가)

  • Lee, Chul-Ho;Park, Moon-Seo;Kwak, Tae-Hoon;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.229-239
    • /
    • 2010
  • Performing a series of in-situ thermal response tests, the effective thermal conductivity of six vertical closed-loop ground heat exchangers was experimentally evaluated and compared each other, which were constructed in a test bed in Wonju. To compare thermal efficiency of the ground heat exchangers in field, the six boreholes were constructed with different construction conditions: grouting materials (cement vs. bentonite), different additives (silica sand vs. graphite) and the shape of pipe-sections (general U-loop type vs. 3 pipe-type). From the test results, it can be concluded that cement grouting has a higher effective thermal conductivity than that of bentonite grouting, and the efficiency of graphite better performs over silica sand as a thermally-enhancing addictive. In addition, a new 3 pipe-type heat exchanger provides less thermal interference between the inlet and outlet pipe than the conventional U-loop type heat exchanger, which results in superior thermal performance.

  • PDF