• Title/Summary/Keyword: The Environmental Test

Search Result 10,359, Processing Time 0.053 seconds

Prediction of Forest Fire Danger Rating over the Korean Peninsula with the Digital Forecast Data and Daily Weather Index (DWI) Model (디지털예보자료와 Daily Weather Index (DWI) 모델을 적용한 한반도의 산불발생위험 예측)

  • Won, Myoung-Soo;Lee, Myung-Bo;Lee, Woo-Kyun;Yoon, Suk-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • Digital Forecast of the Korea Meteorological Administration (KMA) represents 5 km gridded weather forecast over the Korean Peninsula and the surrounding oceanic regions in Korean territory. Digital Forecast provides 12 weather forecast elements such as three-hour interval temperature, sky condition, wind direction, wind speed, relative humidity, wave height, probability of precipitation, 12 hour accumulated rain and snow, as well as daily minimum and maximum temperatures. These forecast elements are updated every three-hour for the next 48 hours regularly. The objective of this study was to construct Forest Fire Danger Rating Systems on the Korean Peninsula (FFDRS_KORP) based on the daily weather index (DWI) and to improve the accuracy using the digital forecast data. We produced the thematic maps of temperature, humidity, and wind speed over the Korean Peninsula to analyze DWI. To calculate DWI of the Korean Peninsula it was applied forest fire occurrence probability model by logistic regression analysis, i.e. $[1+{\exp}\{-(2.494+(0.004{\times}T_{max})-(0.008{\times}EF))\}]^{-1}$. The result of verification test among the real-time observatory data, digital forecast and RDAPS data showed that predicting values of the digital forecast advanced more than those of RDAPS data. The results of the comparison with the average forest fire danger rating index (sampled at 233 administrative districts) and those with the digital weather showed higher relative accuracy than those with the RDAPS data. The coefficient of determination of forest fire danger rating was shown as $R^2$=0.854. There was a difference of 0.5 between the national mean fire danger rating index (70) with the application of the real-time observatory data and that with the digital forecast (70.5).

Assessment of water supply reliability in the Geum River Basin using univariate climate response functions: a case study for changing instreamflow managements (단변량 기후반응함수를 이용한 금강수계 이수안전도 평가: 하천유지유량 관리 변화를 고려한 사례연구)

  • Kim, Daeha;Choi, Si Jung;Jang, Su Hyung;Kang, Dae Hu
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.993-1003
    • /
    • 2023
  • Due to the increasing greenhouse gas emissions, the global mean temperature has risen by 1.1℃ compared to pre-industrial levels, and significant changes are expected in functioning of water supply systems. In this study, we assessed impacts of climate change and instreamflow management on water supply reliability in the Geum River basin, Korea. We proposed univariate climate response functions, where mean precipitation and potential evaporation were coupled as an explanatory variable, to assess impacts of climate stress on multiple water supply reliabilities. To this end, natural streamflows were generated in the 19 sub-basins with the conceptual GR6J model. Then, the simulated streamflows were input into the Water Evaluation And Planning (WEAP) model. The dynamic optimization by WEAP allowed us to assess water supply reliability against the 2020 water demand projections. Results showed that when minimizing the water shortage of the entire river basin under the 1991-2020 climate, water supply reliability was lowest in the Bocheongcheon among the sub-basins. In a scenario where the priority of instreamflow maintenance is adjusted to be the same as municipal and industrial water use, water supply reliability in the Bocheongcheon, Chogang, and Nonsancheon sub-basins significantly decreased. The stress tests with 325 sets of climate perturbations showed that water supply reliability in the three sub-basins considerably decreased under all the climate stresses, while the sub-basins connected to large infrastructures did not change significantly. When using the 2021-2050 climate projections with the stress test results, water supply reliability in the Geum River basin was expected to generally improve, but if the priority of instreamflow maintenance is increased, water shortage is expected to worsen in geographically isolated sub-basins. Here, we suggest that the climate response function can be established by a single explanatory variable to assess climate change impacts of many sub-basin's performance simultaneously.

Evaluation of Ecological Niche for Major Tree Species in the Natural Deciduous Forest of Mt. Chumbong (점봉산(點鳳山) 일대(一帶) 천연활엽수림(天然闊葉樹林)의 주요(主要) 구성(構成) 수종(樹種)에 대한 생태지위(生態地位) 평가(評價))

  • Kim, Guang Ze;Kim, Ji Hong
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.3
    • /
    • pp.380-387
    • /
    • 2001
  • The characteristics of ecological niche, breadth and overlap, for seventeen major tree species were evaluated in the natural deciduous forest in Mt. Chumbong area. Employed by the plot sampling method, the environmental gradient for vertical niche was based on the intensity of light within the forest, and that for horizontal niche was based on multi-dimensional resources in distribution pattern. The result showed that Fraxinus rhynchophylla had the highest value of vertical niche breadth and Maackia amurensis had the lowest, and Acer pseudo-sieboldianum had the highest value of horizontal niche breadth and Betula costata had the lowest. There was no significant correlation between both measures of niche breadth. However, the tolerance index for each species was positively correlated to the values of niche breadth. Spearman's rank correlation coefficients were applied to test the correlationship between the species ranks of tolerance index and those of two ecological niche breadths. The coefficient of $r_s=0.432$ ($P{\leq}0.1$) was not enough to support significant correlationship between the tolerance index and vertical niche breadth at the 95% probability. If Carpinus cordata, rarely reach canopy of the forest due to its own growth form, are excluded from the analysis, coefficient was calculated as $r_s=0.650$ ($P{\leq}0.01$), resulting in highly significant correlationship. The Spearman's rank correlation coefficient was $r_s=0.797$ ($P{\leq}0.01$) for tolerance indices and the values of horizontal niche breadth, indicating highly significant. Four distinctive species groups, produced by cluster analysis on the basis of ecological niche overlap for each pair of species, were in considerable accord with the positively associated species constellation pattern created by the inter-species association analysis.

  • PDF

A Study on Leaching Characteristics of $Cr^{6+}$ in Cement Grout Materials (시멘트 그라우트재에서 $Cr^{6+}$용출특성에 관한 연구)

  • 김동우;이재영;천병식
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.62-69
    • /
    • 2003
  • The aim of research is the evaluation of the $Cr^{6+}$ emission features of the liquid injection through emission experiments in varying conditions, based on a field-mixing ratio. The results showed that the content of $Cr^{6+}$ content in cement measured had an Ordinary Potland Cement (OPC) of 25.3 mg/kg, which constitute the largest portion among the other materials. Likewise, the emission experiment of homo-gel and sand-gel generally satisfied the standard of KSLT (Korea Standard Leaching Test) in waste of 1.5 mg/L, but in case of the standard of KSLT in soil the emission of OPC $Cr^{6+}$ of 4.85 mg/kg. These conditions is a little exceeded the criteria in the ‘Ga’ area in terms of Korea Soil Environmental Preservation Law. In addition, results generated by the mock-up injection facilities revealed that $Cr^{6+}$ emission increased as Water/Cement and injection pressure increased. At injection pressure higher than 4 kg/㎤, $Cr^{6+}$ emission exceeded the water preservation standard of 0.5 mg/L. Similarly, a pattern experiment of C $r^{6+}$ emission according to pH was conducted, in order to evaluate the $Cr^{6+}$ emission features of grout materials in leachate below pH 5 such as pH 4 acid rain or landfill. Results show that $Cr^{6+}$ emission dramatically increased in high acidic or basic state. It indicates that $Cr^{6+}$ emission will probably increase in an environment where grout materials are injected. On the other hand, concentration of leachate was determined in areas where grout materials are used. The results show that the concentration of emission in an ultra purity condition does not manifest intensity, and is affected in the OPC>MC>SC order. It means that the pollutants or $Cr^{6+}$ emission increases with decreasing concentration. As such, $Cr^{6+}$ emission will probably exceed the countermeasure criteria according to the types of gout materials. Similarly, high pressure or injection will cause increased $Cr^{6+}$ emission. Therefore, the selection of materials or mixing ratio should be considered in general as well as according to specific industries, based on the strength and pH of $Cr^{6+}$ emission.

Feasibility Test on Automatic Control of Soil Water Potential Using a Portable Irrigation Controller with an Electrical Resistance-based Watermark Sensor (전기저항식 워터마크센서기반 소형 관수장치의 토양 수분퍼텐셜 자동제어 효용성 평가)

  • Kim, Hak-Jin;Roh, Mi-Young;Lee, Dong-Hoon;Jeon, Sang-Ho;Hur, Seung-Oh;Choi, Jin-Yong;Chung, Sun-Ok;Rhee, Joong-Yong
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.93-100
    • /
    • 2011
  • Maintenance of adequate soil water potential during the period of crop growth is necessary to support optimum plant growth and yields. A better understanding of soil water movement within and below the rooting zone can facilitate optimal irrigation scheduling aimed at minimizing the adverse effects of water stress on crop growth and development and the leaching of water below the root zone which can have adverse environmental effects. The objective of this study was to evaluate the feasibility of using a portable irrigation controller with an Watermark sensor for the cultivation of drip-irrigated vegetable crops in a greenhouse. The control capability of the irrigation controller for a soil water potential of -20 kPa was evaluated under summer conditions by cultivating 45-day-old tomato plants grown in three differently textured soils (sandy loam, loam, and loamy sands). Water contents through each soil profile were continuously monitored using three Sentek probes, each consisting of three capacitance sensors at 10, 20, and 30 cm depths. Even though a repeatable cycling of soil water potential occurred for the potential treatment, the lower limit of the Watermark (about 0 kPa) obtained in this study presented a limitation of using the Watermark sensor for optimal irrigation of tomato plants where -20 kPa was used as a point for triggering irrigations. This problem might be related to the slow response time and inadequate soil-sensor interface of the Watermark sensor as compared to a porous and ceramic cup-based tensiometer with a sensitive pressure transducer. In addition, the irrigation time of 50 to 60 min at each of the irrigation operation gave a rapid drop of the potential to zero, resulting in over irrigation of tomatoes. There were differences in water content among the three different soil types under the variable rate irrigation, showing a range of water contents of 16 to 24%, 17 to 28%, and 24 to 32% for loamy sand, sandy loam, and loam soils, respectively. The greatest rate increase in water content was observed in the top of 10 cm depth of sandy loam soil within almost 60 min from the start of irrigation.

Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well (지하수정호 결합 복합지열시스템의 시범운영 효과분석)

  • Song, Jae-Yong;Kim, Ki-Joon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.475-488
    • /
    • 2018
  • This study evaluates geothermal system efficiency in terms of input power and heat exchange volume on the heat-source and load sides, by applying a combined open-closed type loop system comprising a geothermal system and a groundwater well to a cultivation site. In addition, this study analyzes the effects of heating and cooling for a complex geothermal system, by evaluating the temperatures of an external site and a cultivation site during operation. During cooling operations the heat exchange volume on the heat source side, average 90.0kW/h for an open type system with an input of 235L/minute groundwater, and 40.1kW/h for a closed type system with an input of 85L/minute circulating water, for a total average heat exchange volume of 130.1kW/h. The actual heat exchange volume delivered on the load side averages 110.4kW/h. The average EER by analysis of the geothermal system's cooling efficiency is 5.63. During heating operation analysis, the heat exchange volume on the heat source side, average 60.4kW/h in an open type system with an input of 266L/minute groundwater, and 22.4kW/h in closed type system with an input of 86L/minute circulating water, for a total average heat exchange volume of 82.9kW/h. The actual heat exchange volume delivered on the load side averages 112.0kW/h in our analysis. The average COP determined by analysis of the geothermal system's heating efficiency is 3.92. Aa a result of the tradeoff between the outside temperature and the inside temperature of the production facility and comparing the facility design with a combined well and open-closed loops geothermal(CWG) system, we determine that the 30RT-volume CWG system temperature are lower by $3.4^{\circ}C$, $6.8^{\circ}C$, $10.1^{\circ}C$ and $13.4^{\circ}C$ for ouside temperature is of $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$, respectively. Based on these results, a summer cooling effect of about $10^{\circ}C$ is expected relative to a facility without a CWG system as the outside temperature is generally ${\geq}30^{\circ}C$. Our results suggest that a complex geothermal system provides improvement under a variety of conditions even when heating conditions in winter are considered. Thus It is expected that the heating-cooling tradeoffs of complex geothermal system are improved by using water screen.

Interaction of Sodium Selenite on Neurotoxicity Induced by Methylmercuric Chloride (유기수은의 신경독성에 대한 셀레늄의 보상작용)

  • Park, J.S.;Lee, H.M.;Chung, Y.;Shin, D.C.;Roh, J.H.;Moon, Y.H.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.25 no.1 s.37
    • /
    • pp.13-25
    • /
    • 1992
  • This study was conducted to investigate the mechanism of protective effect by sodium selenite in methylmercuric chloride neurotoxicity, increasing intracellular $Ca^{2+}$concentration of the neuron. Methylmercuric chloride of 3mg/kg of body weight was administered simultaneously with sodium selenite of 5mg/kg and pretreatment of sodium selenite via intraperitoneal injection to rats. Also, effect of methylmercuric chloride($25{\mu}M,\;50{\mu}M,\;100{\mu}M$) and sodium selenite($200{\mu}M$) on free intrasynaptosomal $Ca^{2+}$ concentration were studied using the fluorescent $Ca^{2+}$ indicator fura -2 in vitro. After the treatment, at 6, 24, and 48 hours later, mercury in the cerebral cortex, liver and kidney tissues, succlnic dehydrogenase activities, adenosin-5'-triphosphate concentration, acetylcholinesterase activities, and intracellular $Ca^{2+}$ concentration in the cerebral cortex were determined in vivo. Cerebral synaptosomes of rats were incubated with methylmercuric chloride and sodium selenite in Hepes buffer for 10 minutes and free intrasynaptosomal $Ca^{2+}$ concentration were measured with fura-2 in vitro. The results were summarized as follows ; 1. The combined administration of $CH_3HgCl$ and $Na_2SeO_3$ and pretreatment of $Na_2SeO_3$ according to time significantly more increased in the cerebral cortex and decreased in the liver, kidney mercury concentrations compared to the administration of $CH_3HgCl$ only. 2. The combined administration of $CH_3HgCl$ and $Na_2SeO_3$ and pretreatment of $Na_2SeO_3$ increased more succinic dehydrogenase and acetylcholinesterase activities compared to the administration of $CH_3HgCl$ only. Particularly pretreatment of $Na_2SeO_3$ significantly more compared to the administration of $CH_3HgCl$ only. The concentration of adenosine-5'-triphosphate in $Na_2SeO_3$ treatment groups revealed a favourable effect compared to the administration of $CH_3HgCl$ only. 3. Intracellular $Ca^{2+}$ concentration in administration of $CH_3HgCl$ only was increased significantly more than control group in all test hours but was increased significantly more at 48 hours only after treatment in combined administration of $CH_3HgCl$ and $Na_2SeO_3$ and pretreatment of $Na_2SeO_3$ according to time interval more decreased significantly intracellular $Ca^{2+}$ concentration compared to the administration of $CH_3HgCl$ only. 4. Free intrasynaptosomal $Ca^{2+}$ concentration in the combined administration of $CH_3HgCl$ and $Na_2SeO_3$ was decreased ($24%{\sim}40%$) significantly more than the administration of $CH_3HgCl$ only. From the above results, the specific dosage of $Na_2SeO_3$ decreased increment of intracellular $Ca^{2+}$ concentration induced by administration of $CH_3HgCl$. These findings suggest the protective mechanism of $Na_2SeO_3$ on the neurotoxicity of $CH_3HgCl$.

  • PDF

A Study on Fall Accident (1개 종합병원 환자의 낙상에 관한 조사)

  • Lee, Hyeon-Suk;Kim, Mae-Ja
    • The Korean Nurse
    • /
    • v.36 no.5
    • /
    • pp.45-62
    • /
    • 1998
  • The study was conducted from November 1995 to May 1996 at the one general hospital in Seoul. The total subjects of this study were 412 patients who have the experience of fall accident, among them 31 was who have fallen during hospitalization and 381 was who visited emergency room and out patient clinic. The purposes of this study were to determine the characteristics, risk factors and results of fall accident and to suggest the nursing strategies for prevention of fall. Data were collected by reviewing the medical records and interviewing with the fallers and their family members. For data analysis, spss/pc+ program was utilized for descriptive statistics, adjusted standardized $X^2$-test. The results of this study were as follows: 1) Total subjects were 412 fallers, of which 245(59.5%) were men and 167(40.5%) were women. Age were 0-14 years 79(19.2%), 15-44 years 125(30.4%), 45-64 years 104(25.2%), over 65 years 104(25.2%). 2) There was significant association between age and the sexes ($X^2$=39.17, P=0.00). 3) There was significant association between age and history of falls ($X^2$=44.41. P= .00). And history of falls in the elderly was significantly associated with falls. 4) There was significant association with age and medical diagnosis ($X^2$=140.66, P= .00), chief medical diagnosis were hypertension(34), diabetis mellitus(22), arthritis(11), stroke(8), fracture(7), pulmonary tuberculosis(6), dementia(5) and cataract(5), 5) There was significant association between age and intrinsic factors: cognitive impairment, mobility impairment, insomnia, emotional problems, urinary difficulty, visual impairments, hearing impairments, use of drugs (sedatives , antihypertensive drugs, diuretics, antidepressants) (P < 0.05). But there was no significant association between age and dizziness ($X^2$=2.87, P=.41). 6) 15.3% of total fallers were drunken state when they were fallen. 7) Environmental factors of fall accident were unusual posture (50.9%), slips(35.2%), trips (9.5%) and collision(4.4%). 8) Most of falls occurred during the day time, peak frequencies of falls occurred from 1pm to 6pm and 7am to 12am. 9) The places of fall accident were roads(22.6%), house-stairs 06.7%), rooms, floors, kitchen (11.2%), the roof-top, veranda, windows(10.9%), hospital(7.5%), ice or snowy ways(5.8%), bathroom(4.9%), playground, park(4.9%), subway-stairs(4.4%) and public-bathrooms (2.2%). 10) Activities at the time of fall accident were walking(37.6%), turning around or reaching for something(20.9%), going up or down stairs09.2%), exereise, working07.4%), up or down from a bed(2.7%), using wheelchair or walking aids, standing up or down from a chair(2.2%) and standing still(2.2%). 11) Anatomical locations of injuries by falls were head, face, neck(31.3%), lower extremities (29.9%). upper extremities(20.6%), spine, thorax, abdomen or pelvic contents(l1.4%) and unspecified(2.9%). 12) Types of injures were fracture(47.6%), bruises03.8%), laceration (13.3%), sprains(9.0%), headache(6.6%), abrasions(2.9%), intracranial hemorrage(2.4%) and burns(0.5%). 13) 41.5% of the fallers were hospitalized and average of hospitalization was 22.3 days. 14) The six fallers(1.46%) died from fall injuries. The two fallers died from intracranial hemorrage and the four fallers died of secondary infection; pneumonia(2), sepsis(1) and cell lulitis(1). It is suggested that 1) Further study is needed with larger sample size to identify the fall risk factors. 2) After the fall accident, comprehensive nursing care and regular physical exercise should be emphasized for the elderly person. 3) Safety education and safety facilities of the public place and home is necessary for fall prevention.

  • PDF

Analysis of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Shaped Steel with Tension Softening Behavior (인장연화거동을 고려한 강섬유 보강 초고성능 콘크리트 바닥판과 역T형 강재 합성보의 휨거동 해석)

  • Yoo, Sung-Won;Yang, In-Hwan;Jung, Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.185-193
    • /
    • 2015
  • Ultra high performance concrete (UHPC) has been developed to overcome the low tensile strengths and brittleness of conventional concrete. Considering that UHPC, owing to its composition and the use of steel fibers, develops a compressive strength of 180 MPa as well as high stiffness, the top flange of the steel girder may be superfluous in the composite beam combining a slab made of UHPC and the steel girder. In such composite beam, the steel girder takes the form of an inverted-T shaped structure without top flange in which the studs needed for the composition of the steel girder with the UHPC slab are disposed in the web of the steel girder. This study investigates experimentally and analytically the flexural behavior of this new type of composite beam to propose details like stud spacing and slab thickness for further design recommendations. To that goal, eight composite beams with varying stud spacing and slab thickness were fabricated and tested. The test results indicated that stud spacing running from 100 mm to 2 to 3 times the slab thickness can be recommended. In view of the relative characteristic slip limit of Eurocode-4, the results showed that the composite beam developed ductile behavior. Moreover, except for the members with thin slab and large stud spacing, most of the specimens exhibited results different to those predicted by AASHTO LRFD and Eurocode-4 because of the high performance developed by UHPC.

Changes of Microbial Community Associated with Construction Method and Maintenance Practise on Soil Profile in Golf Courses (지반 조성과 관리방법에 따른 골프장 토양내 미생물 군집의 변화)

  • Moon, Kyung-Hee;Kim, Ki-Dong;Joo, Young-Kyoo
    • Asian Journal of Turfgrass Science
    • /
    • v.23 no.2
    • /
    • pp.219-228
    • /
    • 2009
  • The construction procedures and artificial turf maintenance program on golf course definitely influence on the distortion of its environment. Soil microbial communities in soil profile were affected directly by those practises on turf areas. In Jeju island, the environmental impact assessment has been required to apply the first quality class granular activated carbon(GAC), which has a high absorbent character to agricultural chemicals, on the soil profiles of golf green system to reduce the pesticide leaching to ground water. This research was carried out to analyze the changes of microbial communities and chemical properties on soil profiles where GAC had been applied at the construction stage at two golf courses in Jeju. The changes of soil microbial population and chemical properties associated with construction methods of soil profile and agrochemical management program were analyzed by monthly at the surface and sub-soil profiles during April through October, 2007. The total numbers of bacteria and fungi, soil moisture content, soil physio-chemical properties were measured on greens and fairways of the both golf courses with different GAC treatment on the green and fairway soil profiles. The results showed that GAC had positive effects on the water holding capacity, pH and EC, however, it did not improved the holding capacity of available nutrients ${NO_3}^-,{NH_4}^+$, and phosphorus by its sorption phenomenon. In microbial count test, the total numbers of bacteria and fungi showed a great variation during sampling dates. That may directly relate to the agrochemical application, however, the ratio of total bacterial number versus total fungus number showed a constant value on a sub-soil of 15~30cm depth. Thus, the construction method of GAC in soil profile, and application of fertilizer and pesticide, both impacted on the changes of microbial population. It's means that the construction method of soil profile and turf management using agro-materials might greatly affect on the turfgrass culture and the environment of golf course.