• Title/Summary/Keyword: The 10-second test

Search Result 4,989, Processing Time 0.04 seconds

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • v.15 no.1
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

Temperature development and cracking characteristics of high strength concrete slab at early age

  • Wu, Chung-Hao;Lin, Yu-Feng;Lin, Shu-Ken;Huang, Chung-Ho
    • Structural Engineering and Mechanics
    • /
    • v.74 no.6
    • /
    • pp.747-756
    • /
    • 2020
  • High-strength concrete (HSC) generally is made with high amount of cement which may release large amount of hydration heat at early age. The hydration heat will increase the internal temperature of slab and may cause potential cracking. In this study, slab specimens with a dimension of 600 × 600 × 100 mm were cast with concrete incorporating silica fume for test. The thermistors were embedded in the slabs therein to investigate the interior temperature development. The test variables include water-to-binder ratio (0.25, 0.35, 0.40), the cement replacement ratio of silica fume (RSF; 5 %, 10 %, 15 %) and fly ash (RFA; 10 %, 20 %, 30 %). Test results show that reducing the W/B ratio of HSC will enhance the temperature of first heat peak by hydration. The increase of W/B decrease the appearance time of second heat peak, but increase the corresponding maximum temperature. Increase the RSF or decrease the RFA may decrease the appearance time of second heat peak and increase the maximum central temperature of slab. HSC slab with the range of W/B ratio of 0.25 to 0.40 may occur cracking within 4 hours after casting. Reducing W/B may lead to intensive cracking damage, such as more crack number, and larger crack width and length.

A Validation Study for the Infant/Toddler Environment Rating Scale(ll) (영아/걸음마기 아동 환경 평정 척도 타당화 연구 (ll))

  • 이완정
    • Journal of the Korean Home Economics Association
    • /
    • v.36 no.6
    • /
    • pp.95-108
    • /
    • 1998
  • This study is the second study which was aimed to validate the Infant/ Toddler Environment Rating Scale(ITERS). The test-retest reliability included 10 infant/toddler classes among 30 national/public and private child care centers in Inchon city which had been observed in the first validation study. The Spearman's correlation coefficient for test-retest reliability was ranged from .52 to .84. In addition, two raters observed 10 family day care centers in Inchon city, where two observers independently rated each centers on the ITERS during a single visit. The Spearman's correlation coefficient for interrater reliability was ranged from.72 to .99 For the second measure of content validity, experts who were working in day care centers and who were graduate students, lecturers, or professors majoring child studies rated the appropriateness of each ITERS items for the provision of high-quality programs for infants and toddlers, using a 1(low) to 5(high) scale. The mean rating was ranged from 2.52 to 4.52. In sum, when the rating scores were analyzed by the type of child care centers, national/public child care centers have better quality than private or family child care centers.

  • PDF

Acute Systemic Infusion of Bupropion Decrease Formalin Induced Pain Behavior in Rat

  • Naderi, Somayyeh;Pakdel, Firouz Ghaderi;Osalou, Mostafa Ashrafi;Cankurt, Ulker
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.118-124
    • /
    • 2014
  • Background: The chronic pain can disturb physical, psychological, and social performances. Analgesic agents are widely used but some antidepressants (ADs) showed analgesia also. Bupropion is using for smoke cessation but it can change morphine withdrawal signs such as pain. This study tested the acute systemic effect of bupropion on formalin induced pain behavior in rats. Methods: Wistar male healthy rats were divided into 7 groups (control, sham, and 5 treated groups with 10, 30, 90, 120, and 200 mg/kg of bupropion, i.p.). The bupropion injected 3 hours prior to formalin induced pain behavior. Formalin (50 ${\mu}l$, 2.5%) was injected subcutaneously in dorsal region of right hindpaw in all animals. Nociceptive signs were observed continuously on-line and off-line each minute. Common pain scoring was used for pain assessment. Results: The analysis of data by one-way ANOVA showed that bupropion can reduce pain scores in the second phase but not in first phase. Bupropion decreased the licking/biting duration significantly in first and second phase of formalin test. Conclusions: The results showed that bupropion has analgesic effects at systemic application. The change of second phase of the pain behavior was significant and it revealed that central mechanisms involve in bupropion analgesia.

The Effect of Neuromuscular Electrical Stimulation on Pulmonary Function, Gait Ability, and Quality of Life in Patients with Chronic Obstructive Pulmonary Disease

  • Kang, Jeong-il;Park, Jun-Su;Jeong, Dae-Keun
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.4
    • /
    • pp.129-134
    • /
    • 2018
  • Purpose: This study aims to investigate the changes in pulmonary function, gait ability, and quality of life when NMES is applied along with CBE and to provide basic clinical data to be used in pulmonary rehabilitation guidelines for patients with COPD to treat patients with severe COPD. Methods: For this study, CBE and NMES of quadriceps femoris on both sides were applied to the experimental group (n=10), and only CBE was applied to the control group (n=10). For a pre-test, a 6-minute walk test was performed, and pulmonary function and health-related quality of life were measured. Moreover, an exercise program was applied to each group for 30 minutes per session, 5 times a week, for 6 weeks. After that, a post-test was conducted the same way as the pre-test. Results: In the within-group comparison, there were significant differences in forced expiratory volume in one second, 6-minute walk test and health-related quality of life between the experimental group and the control group (p<0.01)(p<0.05). In the between-group comparison, the experimental group showed an increase in forced expiratory volume in one second and 6-minute walk test (p<0.05) and showed a decline in health-related quality of life (p<0.05). Conclusion: The 6-weeks NMES program improved health-related quality in patients with severe COPD by increasing expiratory volume by reinforcing the function of quadriceps femoris. This finding implies that NMES could be an alternative mode for improving physical functions of patients with severe COPD, who cannot participate in a breathing exercise program or are reluctant to participate.

Development of Slim-Fit Pants Pattern for Obese Male Adolescents (비만 남자 청소년의 슬림핏 팬츠 패턴 개발)

  • Lim, Bo Yun;Kweon, Soo Ae;Kim, Jiyoung
    • Journal of Fashion Business
    • /
    • v.22 no.5
    • /
    • pp.96-112
    • /
    • 2018
  • This study developed the pants pattern, that improved appearance and gesture functions in clothes to resolve inconveniences in case of activities with being adequate in fitness of slim-fit pants for obese adolescents. The slim-fit pants pattern was developed through the fitting test after designing and making the pattern of the experimental clothing A(c/pu; 99/1%) with the primary commercial clothing as basic prototype, through the fitting test and implementation of the experimental clothing, modified and supplemented secondarily, and through the fitting test of the second experimental clothing, modified and supplemented tertiary. In terms of findings, first, as a result of analyzing the commercial slim-fit pants, it is interpreted to have projected an optical illusion, that appears to be slim due to being narrow in width of the front panel when observed from the front of the pants. Second, in the fitting test of the first experimental clothing, the prototype of commercial clothing was understood to have improved butt, crotch, waist and femoral regions. Third, pattern design of the second experimental clothing was allowed to decline abdominal pressure, in case of the sitting position, by making the crotch line in the front panel short and by handling it with a yoke belt, and was processed a difference between waist and hip circumference in the back panel, with a rubber band in the whole waist part. Fourth, in the gesture function test of the third experimental clothing, high evaluation was received in every item excluding the knee region.

Second-order Motion Characteristics of a Semi-submersible Platform in Waves

  • Hong, Sa-Young;Nam, Bo-Woo;Kim, Jin-Ha;Kim, Young-Shik;Hong, Seok-Won;Kim, Young-Soo
    • International Journal of Ocean System Engineering
    • /
    • v.1 no.3
    • /
    • pp.155-164
    • /
    • 2011
  • The second-order motion characteristics of a semi-submersible are investigated in regular waves. A higher-order boundary element method in a frequency domain and a finite element method in a time-domain were applied to the numerical analysis of the nonlinear hydrodynamic force and motion characteristics of semi-submersibles in view point of potential flow. Various aspects of nonlinear effects on the heave and roll of a semi-submersible were numerically investigated and some selected cases were compared with the model test data.

System Level Space Environment Testing of Satellite Digital Transponder (디지털 위성중계기에 대한 시스템 단위의 우주환경 검증 시험)

  • Song, Young-Joong;Kim, Jung-Ho;Lee, Sue-Hyun;Seo, Hak-Geum;Shin, Guan-Ho;Jin, Bong-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.12
    • /
    • pp.1159-1169
    • /
    • 2013
  • EQM Model Digital transponder applying the Korean's own designing and manufacturing technology has gone through a series of trials and errors during the development. In particular, lack of thermal designs expedience for the vacuum causes variety of errors in designing, assembling transponder and setting up the test at the first thermal vacuum test (TVAC). Since the first TVAC test could not accomplished its aims successfully, so the second TVAC should be performed as make up test with revised Digital transponder. In this paper, the defects that identified in the first TVAC are analyzed and applied solutions and its results at the second TVAC are presented. Using the lessons from the first and second TVAC, we will be able to make more reliable digital transponders in the next phase of project. In addition it also be useful as a reference when we design another satellite payloads.

Launch Environment Test for Scale magNetospheric and Ionospheric Plasma Experiment (SNIPE) Engineering Qualification Model (초소형위성 SNIPE(Scale Magnetospheric and Ionospheric Plasma Experiment) 시제인증모델의 발사환경시험 및 분석)

  • Kim, Min-Ki;Kim, Hae-Dong;Choi, Won-Sub;Kim, Jin-Hyung;Kim, KiDuck;Kim, Ji-Seok;Cho, Dong-Hyun
    • Journal of Space Technology and Applications
    • /
    • v.1 no.3
    • /
    • pp.319-336
    • /
    • 2021
  • This paper discusses the results of launch environment tests for the engineering qualification model (EQM) of nanosatellite Scale magNetospheric and Ionospheric Plasma Experiment (SNIPE) for scientific missions and lessons learned for the design of nanosatellites. SNIPE is a group of four formation-flying 6U nanosatellites with a range of payloads for missions including space weather measurement. We developed the EQM to verify the preliminary design prior to fabricating the flight model. Launch environment test of EQM was conducted for the first time in 2019, and all failures were corrected and verified at the second test conducted in 2021. A notable point of the two tests is that the nanosatellite deployer used in the first test is different from that of the second test. The second deployer has the capability to fix the internal satellite whereas the first deployer just contains and deploys the satellite. Thus actual mechanical loads the satellite receives is reduced for the second test compared to the first test. This work compares the mechanical responses of two tests and proposes general guidelines for structural design of nanosatellites.

Development and Simulation Verification of Operation System for Mobile ESS Test Equipment (ESS 이동형 시험장비용 운영시스템의 개발과 모의검증)

  • Shin, Je-Seok;Han, Hyun-Gyu;Kim, Jin-Tae;Lee, Seung-Min;Park, Chan-Wook;Lim, Geon-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.168-174
    • /
    • 2018
  • The performance test for 376MW ESS for frequency regulation currently operating in 13 substations is conducted based on the test procedure in the first and second steps. In the first step, components of ESS is moved to the certification authority where the test equipment is located in order to be proceeded with the test. In the second step, the performance test is conducted manually for the ESS equipments installed on site using the movable measurement equipment, and thus it can only be performed on some limited test items and requires a lot of time and manpower. Therefore, mobile test equipment for ESS(MOTES) is being developed that can perform automatically more test items for ESS in the field using the MOTES, and reduce manpower and time. To do this, an algorithm and a prototype of the operating system(MOS) are also being developed that can control MOTES automatically. In this paper, a development of the MOS prototype is introduced and then a simulation is performed to verify the prototype and its algorithm before the field demonstration.