• Title/Summary/Keyword: Thallium

Search Result 130, Processing Time 0.034 seconds

Lung/Heart Uptake Ratio and Transient Dilation Ratio of the Left Ventricle During Thallium-201 Imaging with Dipyridamole (Dipyridamole 부하를 T1-201 심근스캔에서 폐/심장 섭취율과 일과성 좌심실 확장율에 관한 연구)

  • Lee, Jae-Tae;Chung, Byung-Chun;Kim, Sang-Hyun;Lee, Kyu-Bo;Chae, Sung-Chull
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.177-185
    • /
    • 1991
  • Dipyridamole thallium imaging is one of the most widely accepted means of evaluating patients with suspected or known coronay artery disease. The results of thallium imaging help diagnose coronary artery disesse (CAD), determine the hemodynamic significance of coronary stenosis, evaluate viability of myocardium, assess the outcome of therapeutic interventions and stratify patients according to their risk for luther cardiac events. An increased lung thallium uptake and transient LV dilation has been reported as poor prognostic indicator and associated with extensive and severe coronary artery disease. We quantitated lung/heart uptake ratio (l/HUR) and transient left ventricular dilation ratio in 44 patients and 17 controls undertaking dipyridamole thallium-201 scintigraphy. The results are as follows: 1) The lung/heart uptake ratio was high in patients with CAD and which became higher according to increasing number of diseased vessel. The L/HUR of patients with low LVEF (<35%) was lower than those with normal LVEF. 2) Transient left ventricular dilation ratio of CAD patients had no close relation between numbers of diseased vessels and was not higher than normals. But transient left ventricular dilation ratio of patients with myocardial infartion was higher than normals. We concluded that lung/heart uptake ratio seems to be sensitive marker for severity of CAD and myocardial function, but transient left ventricular dilation ratio alone is not sufficient to be a marker for severe and extensive CAD.

  • PDF

A Case of Ectopic Parathyroid Adenoma Detected by 201 Thallium Scintiscan (201 Thallium Scintiscan으로 확인된 이소성 부갑상선 선종의 1예)

  • Shong, Young-Kee;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Min, Hun-Ki;Oh, Seung-Keun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.1
    • /
    • pp.75-78
    • /
    • 1987
  • A 57 year old female patient was diagnosed as primary hyperparathyroidism after incidental finding of hypercalcemia. She was treated with radioiodine for Graves disease twenty years ago. Preoperative localization procedures with sonography and CT were unrevealing but 201 thallium scintiscan clearly demonstrated ectopic parathyroid adenoma which was confirmed by surgery. Brief review of the preoperative parathyroid localization procedure was done and the relationship between radioiodine therapy and hyperparathyroidism was discussed.

  • PDF

Effect of Inhibitors on cell growth and urease activity of Vibrio parahaemolyticus (저해제가 Vibrio parahzemolyticius 균주의 생육 및 요소분해효소의 활성에 미치는 영향)

  • 김종숙;김영희
    • Journal of Life Science
    • /
    • v.10 no.6
    • /
    • pp.558-563
    • /
    • 2000
  • Effect of inhibitors on Vibrio parahaemolyticus cell growth and its urease activity was studied. The growth of the bacterium and the enzyme activity were inhibited by the addition of 0.02% p-hydroxymercuric benzoate, $HgCl_2$and $AgNO_3$. However, same concentration of boric acid, thallium acetate and $Pb(NO_3)_2$ did not affect the cell growth but inhibited urease activity by 25%, 29%, and 38%, respectively. Acetohydroxamic acid was the most potent inhibitor on cell growth by inhibiting 40% but did not affect urease activity. To investigate the effect of inhibitors on urease activity, urease was purified and confirmed on SDS-PAGE. The purified urease was inhibited 100% by the addition of 1 mM acetohydroxamic acid and $AgNO_3$but no inhibition was occurred by the addition of the same concentration of thallium acetate. and the addition of 0.01 mM of $HgCl_2$ and acetohydroxamic acid inhibited the purified urease activity by 39% and 24%, respectively. On 0.1 millimolar basic, acetohydroxamic acid and $HgCl_2$inhibited 4 times more active in urease inhibition than p-hydroxymercuric benzoate whereas no inhibition was occurred either thallium acetate or $Pb(NO_3)_2$.

  • PDF

Synthesis and Characterization of Thallium (Ⅲ) Complexes with Tetracyanoquinodimethane, TI$(TCNQ)_3$ and $TICI_2(TCNQ)_{2.5}$

  • 김미경;김영인;문성배;최성낙
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.5
    • /
    • pp.424-428
    • /
    • 1996
  • TlCl2(TCNQ)2.5 and Tl(TCNQ)3 were obtained from the reaction of LiTCNQ (TCNQ=tetracyanoquinodimethane) and TlX3 (X=Cl and NO3). These compounds were characterized by spectroscopic(IR, UV, EPR), electrochemical methods, and electrical conductivity measurements. Thermal analysis (TG, DSC) was also conducted. The room temperature electrical conductivities of these compounds are in the range of semiconductors. Spectroscopic studies indicate that Tl(TCNQ)3 has fully ionized TCNQ- ions in a form of simple salt, whereas TlCl2(TCNQ)2.5 is consisted of TCNQ- and TCNQ0 as a complex salt. EPR values of TCNQ- radical anion are 1.999 in both compounds and the signal attributable to metal ion is not observed, suggesting that any unpaired electrons are localized on TCNQ radicals, and metal atoms have diamagnetic state. Ligand decomposition and reduction process are simultaneously progressed in both compounds above at 200 ℃. The endothermic activation energy of TlCl2(TCNQ)2.5 is shown somewhat larger than that of Tl(TCNQ)3, it may be due to Tl-Cl bond strength. The mid-peak potentials of these compounds are very similar to those of TCNQ and the values of Epa and Epc are almost equal to 1. The wave of thallium ion is not detected in cyclic voltammogram, hence the redox processes of the complexes might be mainly localized to the TCNQ ligand rather than thallium ion.

Physico-Chemical Properties of $Tl_2O-B_2O_3-SiO_2$ Glasses and Their Phase Separations ($Tl_2O-B_2O_3-SiO_2$ 系 유리의 物理化學的 性質 및 그의 分相)

  • Kim, Kee-Hyong
    • Journal of the Korean Chemical Society
    • /
    • v.12 no.2
    • /
    • pp.65-80
    • /
    • 1968
  • The physico-chemical properties of nine selected thallium borosilicate glasses and other 21 supplementary compositions were investigated. Their composition-property curves are found to be in many respects analogous to those of other borosilicate glasses containing lithia, soda, and lead oxide. It is indicated that certain minima found in the composition-property curves of thallium borosilicate glasses might be caused by a change in boron coordination as has been observed to occur in the $Na_2O-B_2O_3-SiO_2$ glasses. Typical effects of thallium ions on the borosilicate glass are summarized as follows: 1) Addition of thallium ions increased density, refractive index, water solubility, linear coefficient of thermal expansion, and dielectric constant. 2) Increased concentration of thallium decreased the softening point of the glasses, caused fluorescence under ultraviolet radiation and smeared out the absorption edges up to $15{\mu}$ in the infrared region. An extensive liquid immiscibility was found by replication electron microscope technique in the $Tl_2O-B_2O_3-SiO_2$ system. The immiscibility covers a composition range roughly from 55 wt. % Tl2O to the binary system $B_2O_3-SiO_2.$ By acid treatment, it was found that the immiscible glass consists of separate silica-rich and boron-rich phases.

  • PDF

Safety and Feasibility of Thallium-201 Myocardial SPECT with Intravenous Infusion of Disodium Adenosine Triphosphate (ATP) in the Diagnosis of Coronary Artery disease (관상동맥 질환 진단에서 ATP부하 T1-201 심근 관류 SPECT의 안전성과 유용성)

  • Pai, Moon-Sun;Park, Chan-H.;Yoon, Seok-Nam;Kim, Won;Kim, Han-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.250-258
    • /
    • 1998
  • Purpose: ATP (adenosine triphosphate) is a potent coronary vasodilator with a rapid onset of action and a very short half-life. Myocardial perfusion scintigraphy with intravenous ATP has not yet been sufficiently proven in the diagnosis, follow-up, and risk stratification of coronary artery disease. The purpose of this study was to evaluate the safety, feasibility and diagnostic accuracy of pharmacologic stress thallium-201 myocardial SPECT using an intra-venous ATP infusion in patients with suspected coronary artery disease. Materials and Methods: Thallium-201 myocardial SPECT in 319 patients with suspected coronary artery disease were performed after the infusion of ATP (0.08 mg/kg/min for 6 min). The adverse effects were carefully monitored. Coronary angiography was also performed within 3 weeks. Results: Although 76.5% of the patients had some adverse effects, they were transient, mild, and well tolerated. In all patients, the ATP infusion protocol was completed and only 2 patients required aminophylline. The adverse effects were dyspnea in 63%, headache in 31%, flushing in 21%, chest pain in 14% and abdominal discomfort in 5% of the patients. The sensitivity and specificity were 80% and 90% respectively. Conclusion: Thallium-201 myocardial SPECT after 6 min-infusion of ATP at a rate of 0.08 mg/kg/min is safe and has a diagnostic value in detecting coronary artery disease.

  • PDF

Thallium(I)-Selective Electrodes Based on Calix[4]pyrroles

  • Park, Gyeong Sun;Jeong, Seong Uk;Lee, Sim Seong;Kim, Jae Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.9
    • /
    • pp.909-912
    • /
    • 2000
  • Thallium(I) selective electrodes based on meso-alkyl substituted calix[4]pyrroles such as, meso-octamethyl-calix[4]pyrrole (L1), meso-octaethylcalix[4]pyrrole (L2) and meso-tetraspirocyclohexylcalix[4]pyrrole (L3) as sensor molecules have been pre pared and tested. The conditioned electrode (E4) incorporating L3gave best results with a wide working concentration range of 10-5.5 ~10-1 M near-Nernstian slope of 56.0 mV/decade of activity and detection limit of 10-6.0 M. This electrode exhibited a fast response time of 30 s and high selectivity over Na+ , K+ and other metal ions with only Ag+ interfering. The electrode works well in the pH range 2.0-11.0 and can be successfully employed for the determination of Tl+.This proposed electrode was also used as an indicator electrode in potentiometric titration of Tl+.