• Title/Summary/Keyword: Tethered method

Search Result 26, Processing Time 0.025 seconds

Nonlinear Dynamic Analysis of a Tethered Satellite (테더가 있는 인공위성의 비선형 동역학 해석)

  • Lee, Kyu-Ho;Jung, Won-Young;Chung, Jin-Tai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.5
    • /
    • pp.416-421
    • /
    • 2011
  • The purpose of this study is to analyze nonlinear dynamics of a tethered satellite. The nonlinear equations of motion are derived by using Lagrange's equations with the polar coordinate system. In order to analyze the response of tethered satellite, time responses are computed by the Newmark's time integration method. This paper claims that the dynamic behavior of the system is changed by the effect of length of tether, mass ratio of satellites.

Urological Manifestations and Laboratory Findings in Patients with Tethered Cord Syndrome (Tethered cord 증후군에서 비뇨기계 증상 및 검사 소견)

  • Jung Tae-Sung;Kim Eun-Jung;Lee Eun-Sil;Shin Son-Moon;Moon Han-Ku;Park Yong-Hoon
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.155-160
    • /
    • 1997
  • Purpose : Tethered cord syndrome is characterized by progressive motor and sensory disturbances in lower extremities, foot deformities caused by a pathologic fixation of spinal cord resulting in excessive stretching of the spinal cord. It is also frequently associated with urological symptoms include urinary frequency, incontinence, enuresis, urgency and recurrent urinary tract infection. Because there is few report in the literature about urological manifestations of theterd cord syndrome, we conducted a retrospective study on the patients diagnosed as tethered cord syndrome to delineate the characteristics of urologic manifestations in tethered cord syndrome and to establish the policy to evaluate patients who is suspected of tethered cord syndrome. Method : A retrospective study was conducted by reviewing the medical records of nine patients who was diagnosed as tethered cord syndrome from November 1991 to July 1996 in Yeungnam University Hospital. Result : 1) The age distribution of nine patients was as follows; 5 patients were under 2 years, 1 case from 2 to 6 years and 3 cases from 6 to 10 years. 2) Of 9 patients 6 had voiding frequency, urinary incontinence, enuresis, urgency and loss of micturation sense. Radiologic urodynamic studies revealed neurogenic bladder in 5 patients, hydronephrosis and hydroureter in 3, vesicoureteral reflux in 3. 3) Of 6 patients with urological abnormal manifestations 4 underwent spinal cord surgery (detethering). In spite of surgical intervention, the urological manifestations improved in only one patient. Conclusion : Urological abnormalities were common in tethered cord syndrome. Abnormal laboratory findings including urodynamic study were found even before the onset of urological symptoms. We have to concern tethered cord syndrome as one of common causes of voiding frequency and enuresis and to evaluate urological abnormalities as thetered cord syndrome is diagnosed.

  • PDF

Nonlinear Dynamic Analysis of a Satellite with Tether Conveying Fluid (유체가 이송하는 테더가 있는 인공위성의 동특성 분석)

  • Jung, Won-Young;Lee, Kyu-Ho;Chung, Jin-Tai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.8
    • /
    • pp.691-697
    • /
    • 2011
  • The purpose of this study is to analyze nonlinear dynamics of a tethered satellite. The coupled non-linear equations of motion are derived by using the extended Hamilton's principle with the polar coordinate system. In order to analyze the response of tethered satellite, time responses are computed by the Newmark's time integration method. We also investigate the dynamic behavior of the system and the effects of length of tether, tip mass and conveyed fluid through the tether with time variation.

Vertically Distributed Aerosol Sampling and Analysis using Tethered Balloon Sampler System in Ansan (안산지역 내에서의 Tethered Balloon 탑재형 포집기를 이용한 연직 분포된 Aerosol 포집 및 분석)

  • Eun, Hee-Ram;Kim, Whan-Ki;Lee, Hong-Ku;Yoo, Dong-Hyun;Yook, Se-Jin;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.7 no.4
    • /
    • pp.139-149
    • /
    • 2011
  • It is very important to measure atmospheric particles and evaluate the characteristics of them since aerosol can influence atmospheric environment, climate, and health. Satellite, aircraft, radio sonde are usually used to measure the vertical distribution of particle properties, temperature, humidity, and pressure. Although the method of using an aircraft is favorable to collect the horizontal distribution of the particles, but unadaptable to measure the vertical distribution of the particles. However, all-in-one balloon particle sampler system can collect particles depending on each altitude controling the balloon by winch. In this research, we performed the air sampling on the TEM grids using house made light weight impactor at the altitude of 300m and 900m. The collected particles were analyzed using TEM/EDS.

Nonlinear Optical Zeolite Films for Second and Third Harmonic Generation

  • Kim, Hyun-Sung;Pham, Tung Thanh;Yoon, Kyung-Byung
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.1443-1454
    • /
    • 2011
  • Methods to prepare novel second-order nonlinear optical (2O-NLO) materials composed of all-silica zeolite (silicalite-1) and a series of 2O-NLO molecules having high second order hyperpolarizability constants (${\beta}$ values) are reviewed. These methods include the development of novel methods to incorporate a series of hemicyanine (HC) molecules into the channels of silicaite-1 films in uniform orientations. The first method is to incorporate HC molecules tethered with long alkyl chains (octadecyl or longer) into the silicalite-1 channels with the long alkyl chain side first through the hydrophobic-hydrophobic interaction between the long alky chains and the silicalite-1 channels. The second method is to incorporate the HC molecule tethered with a medium length alkyl chain (nonyl) into the silicalite-1 channels with the medium length alkyl chain side first through hydrophobic-hydrophobic interaction between the medium length alky chain in the photoexcited state and the silicalite-1 channels. The third method is to incorporate the HC molecule tethered with propionic acid into the silicalite-1 channels with the propionic acid side last mediated by a tetrabultylammonium cation ion-paired to the propionate unit. A method to prepare a novel third-order nonlinear optical (3O-NLO) material composed of zeolite-Y and PbS or PbSe quantum dots is also reviewed. This Account thus describes a promising new direction to which the search for highly sensitive 2O-NLO and 3O-NLO materials has to be conducted and a new direction to which zeolite research and applications have to be expanded.

Development and Evaluation of Hy-CPC (Hy-CPC의 개발 및 성능평가)

  • Lee, Hong-Ku;Hwang, In-Kyu;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.10 no.3
    • /
    • pp.93-97
    • /
    • 2014
  • Condensation particle counter (CPC) has been one of the most important basic instrument for measuring number concentration of submicron aerosols. The principle of the CPC is to expose aerosols to a supersaturated vapor and cool down which causes adiabatic expansion. The particles grow by heterogenous nucleation to a sufficient size for easy detection by optical method. However, for growth by condensation, CPC essentially needs both saturater and condensor causing a heavy system. Therefore, it is hard to install commercial CPC to tethered balloon package system. In this study, we developed customized CPC for tethered balloon package system called Hy-CPC which is lighter and smaller in structure than commercial CPCs, and evaluated activation efficiency and detection efficiency by Hy-CPC using electrostatic method (electrometer and Faraday cup).

Separation of Lithium Isotopes by Tetraazamacrocycles Tethered to Merrifield Peptide Resin

  • Jeon, Youn-Seok;Jang, Nak-Han;Kang, Byung-Moo;Jeon, Young-Shin;Kim, Chang-Suk;Choi, Ki-Young;Ryu, Hai-Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.451-456
    • /
    • 2007
  • Tetraazamacrocyclic ion exchangers tethered to Merrifield peptide resin (DTDM, TTTM) were prepared and the ion exchange capacity of these was characterized. The isotope separation of lithium was determined using breakthrough method of column chromatography. The isotope separation coefficient was strongly dependent on the ligand structure by Glueckauf's theory. We found that the isotope separation coefficients were increased as the values of distribution coefficients were increased. In this experiment the lighter isotope, 6Li was enriched in the resin phase, while the heavier isotope, 7Li in the solution phase. The ion radius of lighter isotope, 6Li was shorter than the heavier isotope, 7Li. The hydration number of lithium ion with the same charge became small as mass number was decreased. Because 6Li was more strongly retained in the resin than 7Li, the isotopes of lithium were separated with subsequent enrichment in the resin phase.

Target strength estimation by tilt angle and size dependence of rockfish (Sebastes schlegeli) using ex-situ and acoustic scattering model (현수법과 모델을 이용한 조피볼락의 유영자세각과 체장에 따른 음향 후방산란강도)

  • YOON, Euna;KIM, Kiseon;LEE, Intae;JO, Hyeon-Jeong;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.2
    • /
    • pp.152-159
    • /
    • 2017
  • Rockfish was a commercially important fish specie in marine ranching areas in Korea. To estimate density and biomass of rockfish using acoustic method, target strength (TS) information is required on the species. This study measured TS dependence on tilt angle and size on 14 live rockfish individuals at 38, 70, and, 120 kHz by ex-situ measurement (tethered method) and acoustic scattering model (Krichhoff ray mode, KRM). The swimbladdered angle ranged from 18 to $30^{\circ}$ ($mean{\pm}s.d.=26{\pm}4^{\circ}$). The mean TS for all individuals was highest -35.9 dB of tilt angle $-17^{\circ}$ at 38 kHz, -35.4 dB of tilt angle $-25^{\circ}$ at 70 kHz, and -34.9 dB of tilt angle $-22^{\circ}$ at 120 kHz. The ex-situ TS-total length (TL, cm) relationships were $TS_{38kHz}=20log_{10}(TL)-67.1$, $TS_{70kHz}=20log_{10}(TL)-68.6$, and $TS_{120kHz}=20log_{10}(TL)-69.9$, respectively. The model TS-total length (TL, cm) relationships were $TS_{38kHz}=20log_{10}(TL)-66.4$, $TS_{70kHz}=20log_{10}(TL)-67.0$, $TS_{120kHz}=20log_{10}(TL)-67.0$. The two measurements between the ex-situ TS and KRM model for TS-tilt angle and fish size were found to be significantly correlated.

Recyclable single-stranded DNA template for synthesis of siRNAs

  • Ali, Mussa M.;Obregon, Demian;Agrawal, Krishna C.;Mansour, Mahmoud;Abdel-Mageed, Asim B.
    • BMB Reports
    • /
    • v.43 no.11
    • /
    • pp.732-737
    • /
    • 2010
  • RNA interference is a post-transcriptional silencing mechanism triggered by the bioavailability and/or exogenous introduction of double-stranded RNA (dsRNA) into cells. Here we describe a novel method for the synthesis of siRNA in a single vessel. The method employs in vitro transcription and a single-stranded DNA (ssDNA) template and design, which incorporates upon self-annealing, two promoters, two templates, and three loop regions. Using this method of synthesis we generated efficacious siRNAs designed to silence both exogenous and endogenous genes in mammalian cells. Due to its unique design the single-stranded template is easily amenable to adaptation for attachment to surface platforms for synthesis of siRNAs. A siRNA synthesis platform was generated using a 3' end-biotinylated ssDNA template tethered to a streptavidin coated surface that generates stable siRNAs under multiple cycles of production. Together these data demonstrate a unique and robust method for scalable siRNA synthesis with potential application in RNAi-based array systems.

Polymer brush: a promising grafting approach to scaffolds for tissue engineering

  • Kim, Woonjung;Jung, Jongjin
    • BMB Reports
    • /
    • v.49 no.12
    • /
    • pp.655-661
    • /
    • 2016
  • Polymer brush is a soft material unit tethered covalently on the surface of scaffolds. It can induce functional and structural modification of a substrate's properties. Such surface coating approach has attracted special attentions in the fields of stem cell biology, tissue engineering, and regenerative medicine due to facile fabrication, usability of various polymers, extracellular matrix (ECM)-like structural features, and in vivo stability. Here, we summarized polymer brush-based grafting approaches comparing self-assembled monolayer (SAM)-based coating method, in addition to physico-chemical characterization techniques for surfaces such as wettability, stiffness/elasticity, roughness, and chemical composition that can affect cell adhesion, differentiation, and proliferation. We also reviewed recent advancements in cell biological applications of polymer brushes by focusing on stem cell differentiation and 3D supports/implants for tissue formation. Understanding cell behaviors on polymer brushes in the scale of nanometer length can contribute to systematic understandings of cellular responses at the interface of polymers and scaffolds and their simultaneous effects on cell behaviors for promising platform designs.