• Title/Summary/Keyword: Testing procedure

Search Result 880, Processing Time 0.031 seconds

Arthroscopic Decompression of Spinoglenoid Ganglion Cyst (견갑골 극관절와 결절종의 관절경하 감압술)

  • Hwang, Tae Hyok;Wang, Tae Hyun;Cho, Hyung Lae;Kim, Keun Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.2
    • /
    • pp.92-98
    • /
    • 2011
  • Purpose: We describe a all-arthroscopic technique for decompression of spinoglenoid ganglion cyst and present our clinical results for this procedure. Materials and Methods: From March 2006 to June 2009, eight patients (7 males, 1 female; mean age 40.6 years; range: 21~61) were included who underwent arthroscopic decompression of spinoglenoid ganglion cyst. The most common symptoms were vague shoulder pain and external rotation weakness, which lasted 6.4 months (range: 3~8) on average. Five of eight patients were noted abnormalities on electromyographic (EMG) examination to have suprascapular nerve neuropathy and magnetic resonance imaging (MRI) showed spinoglenoid ganglion cysts in all eight patients and the cyst size was 2.6 cm (range: 1.8~3.6). Labral pathology was identified intraoperatively in all patients and the cysts were decompressed by the posterosuperior capsulotomy under arthroscopic control and labral repair with suture anchors was performed in six patients. Results: The average clinical outcome scores including Constant and Murley, Simple shoulder test (SST) all improved significantly at the time of the final follow-up and there were no complications resulting from the procedures. All patients including the patients with abnormal EMG study recovered strength on isokinetic strength testing. Follow-up MRI scans were performed on all patients at a mean of 5.2 months postoperatively (range: 3~12) revealed complete resolution of the cysts and no evidence of recurrences were seen at an average of 18 months (range: 12~26) of follow-up. Conclusion: Arthroscopic decompression of spinoglenoid ganglion cyst effectively restores patient function and all patients in this study showed improvement in their postoperative MRI findings. Arthroscopic decompression is also useful in the appropriate treatment for labral pathology and may contribute to decreased risk of cyst recurrence.

  • PDF

Effects of SNP Markers of the Apolipoprotein E (APOE) Gene on Meat Quantity and Quality Traits in Korean Cattle (한우 아포지단백질 E (APOE) 유전자의 SNP Marker가 육량 및 육질형질에 미치는 영향)

  • Shin, Ki-Hyun;Shin, Sung-Chul;Chung, Ku-Young;Chung, Eui-Ryong
    • Food Science of Animal Resources
    • /
    • v.29 no.1
    • /
    • pp.108-113
    • /
    • 2009
  • Apolipoprotein E (APOE) is a plasma lipoprotein in mammals and plays an important role in the transport and metabolism of lipids such as phospholipids and triglycerides. Therefore, the APOE gene could be a candidate gene controlling lipid metabolism in beef cattle. This study was performed to identify single nucleotide polymorphisms (SNP) in the APOE gene and to investigate the effects of SNP genotype on the carcass traits such as meat quantity and quality in Korean cattle. For PCR amplification, pooled DNA made from unrelated 60 individuals was prepared and primer pairs were designed based on the cDNA sequence of exon 4 region of the bovine APOE gene. A SNP was identified at position 2034 (T/C substitution) of the exon 4 region in the APOE gene. PCR-RFLP procedure with restriction enzyme ACC I was developed for determining the SNP genotype for each of a total of 309 animals with pedigree information and performance records through the national progeny testing program. The frequencies of the genotypes TT, TC and CC were 10.9, 46.9 and 42.2%. Gene frequencies were 0.344 for T allele and 0.656 for C allele. The g.2034T>C SNP genotype showed a significant effect (p<0.05) on dressing percentage and meat color, respectively. Animals with the TT genotype showed higher dressing percentage than those with the CC genotype, and TT genotype had desirable meat color compared with CC genotype. These results suggest that the g.2034T>C SNP genotype of the APOE gene may be useful as a DNA marker for meat quantity index and dressing percentage in Korean cattle.

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

Current Status and Prospects of Various Methods used for Screening Probiotic Microorganisms (Probiotic 미생물 검사에 사용되는 다양한 방법들에 대한 현황과 향후 전망)

  • Kim, Dong-Hyeon;Kim, Hong-Seok;Jeong, Dana;Chon, Jung-Whan;Kim, Hyunsook;Kim, Young-Ji;Kang, Il-Byung;Lee, Soo-Kyung;Song, Kwang-Young;Park, Jin-Hyeong;Chang, Ho-Seok;Seo, Kun-Ho
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.4
    • /
    • pp.203-216
    • /
    • 2016
  • Probiotic microorganisms are thought to provide health benefits when consumed. In 2001, the World Health Organization defined probiotics as "live microorganisms which confer a health benefit on the host, when administered in adequate amounts." Three methods for screening potential probiotics have currently widely available. (1) In vitro assays of potential probiotics are preferred because of their simplicity and low cost. (2) The use of in vivo approaches for exploring various potential probiotics reflects the enormous diversity in biological models with various complex mechanisms. (3) Potential probiotics have been analyzed using several genetic and omics technologies to identify gene expression or protein production patterns under various conditions. However, there is no ideal procedure for selecting potential probiotics than testing cadidate strains on the target population. Hence, in this review, we provide an overview of the different methodologies used to identify new probiotic strains. Furthermore, we describe futre perspectives for the use of in vitro, in vivo and omics in probiotic research.

An effect of Dentin Bonding Procedure on the Shear Bond Strength of Resin Cement to Porcelain Restoration (도재 수복물 합착시 상아질 접착 술식이 레진 시멘트의 전단결합강도에 미치는 영향)

  • Kang, Hae-Jin;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.67-78
    • /
    • 2012
  • The purpose of this study was to determine whether there were differences in shear bond strength to human dentin using IDS technique compared with DDS. Forty freshly extracted human molars were and devided into 4 groups. The control group specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent and cemented with resin cement. The IDS/SE(immediate dentin sealing, Clearfil$^{TM}$ SE Bond) and IDS/SB (immediate dentin sealing, Adapter$^{TM}$ Single Bond 2) specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent(Clearfil$^{TM}$ SE Bond and Adapter$^{TM}$ Sing Bond 2, respectively), whereas DDS specimens were not treated with any dentin bonding agent. IDS/SE, IDS/SB and DDS specimens were thermocycled. Following that delay, specimens were cemented with resin cement. The dentin bonding agent was left unpolymerized until the application of porcelain restoration. Shear bond strengths were measured using a universal testing machine. Specimens also were evaluated for mode of fracture using an optical microscope. The mean shear bond strengths of control group and IDS/SE groups were not statistically different from one another. The bond strength of IDS/SE group had a significantly higher mean than that of DDS group. There was no significant difference in the mean shear bond strength between IDS/SB(4.11MPa) and DDS group. The evaluation of failure modes indicates that most failures in the control group and IDS/SE groups were mixed, whereas failures in the DDS group were interfacial. When preparing teeth for indirect ceramic restoration, IDS with Clearfil$^{TM}$ SE Bond results in improved shear bond strength compared with DDS.

The Study on the Methylmercury Analysis and the Monitoring of Total Mercury and Methylmercury in Fish (어류 중 메틸수은 분석법 확립 및 모니터링)

  • Kim, Hee-Yun;Chung, So-Young;Sho, You-Sub;Oh, Geum-Soon;Park, Seong-Soo;Suh, Jung-Hyuk;Lee, Eun-Ju;Lee, Yoon-Dong;Choi, Woo-Jeong;Eom, Ji-Yoon;Song, Min-Soo;Lee, Jong-Ok;Woo, Gun-Jo
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.882-888
    • /
    • 2005
  • Procedure for analysis of methylmercury in fish was developed, involving addition of HCl, extraction with toluene, and clean-up using L-cystein solution. Obtained extract is analyzed by gas chromatography with electron capture detector using Ulbon HR-Thermon-Hg column. Detection limit and recovery of the method were 0.005mg/kg (expressed as Hg), 98-107 (103%), respectively. Total mercury and methylmercury concentrations in 175 commercial fish samples ranged from [mean-max (mean), unit: mg/kg]: 0.014-1.200 (0.270) and 0.006-0.901 (0.168) in tuna-fish, 0.020-0.934 (0.323) and 0.012-0.553 (0.149) in martin-fish, 0.082-0.782 (0.391) and 0.040-0.436(0.201) in shark, 0,023-0.031 (0.026) and 0,013-0.018 (0.015) in salmon, 0.098-0.193 (0.133) and 0.031-0.015(0.090) in tilefish, and 0,031-0.214 (0.089) and 0.016-0.093 (0.042) in canned tuna respectively. No sample of analyzed fish exceeded 1.0mg/kg wet wt., limit for methylmercury established by Codex. In all species examined, estimated weekly intake was lower than Provisional Tolerable Weekly Intake recommended by the JECFA (the Joint FAO/WHO Expert Committee on Food Additives).

The Effect of Au Addition on the Hardening Mechanism in Ag-30wt%Pd-10wt%Cu Alloy (Ag-30wt% Pd-10wt% Cu 3원합금(元合金) 및 Au 첨가합금(添加合金)의 시효경화특성(時效硬化特性))

  • Lee, K.D.;Nam, S.Y.
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.27-41
    • /
    • 1999
  • The Ag-Pd-Cu alloys containing a small amount of Au is commonly used for dental purposes, because this alloy cheaper than Au-base alloys for clinical use. However, the most important characteristic of this alloy is age-hardenability, which is not exhibited by other Ag-base dental alloys. The specimens used were Ag-30Pd-10Cu ternary alloy and Au addition alloy. These alloys were melted and casted by induction electric furnace and centrifugal casting machine in Ar atmosphere. These specimens were solution treated for 2hr at $800^{\circ}C$ and were then quenched into iced water, and aged at 350-$550^{\circ}C$ Age-hardening characteristic of the small Au-containing Ag-Pd-Cu dental alloys were investigated by means of hardness testing, X-ray diffraction and electron microscope observations, electrical resistance, differential scanning calorimetric, energy dispersed spectra and electron probe microanalysis. Principal results are as follows ; Maximum hardening occured in two co-phases of ${\alpha}_2$ + PdCu In stage II, decomposition of the $\alpha$ solid solution to a PdCu ordered phase($L1_o$ type) and an Ag-rich ${\alpha}_2$ phase occurred and a discontinuous precipitation occurred at the grain boundary. From the electron microscope study, it was concluded that the cause of age-hardening in this alloy is the precipitation of the PdCu redered phase, which has AuCu I type face-centered tetragonal structure. Precipitation procedure was ${\alpha}{\to}{\alpha}_1+PdCu{\to}{\alpha}_2+PdCu$ at Pd/Cu = 3 Pd element of Ag-Pd-Cu alloy is more effective dental alloy on anti-corrosion and is suitable to isothermal ageing at $450^{\circ}C$.

  • PDF

The Effect of Au Addition on the Hardening Mechanism in Ag-20wt% Pd-20wt% Cu (Ag-20wt% Pd-20wt% Cu 3원합금(元合金) 및 Au첨가합금(添加合金)의 시효경화특성(時效硬化特性))

  • Park, M.H.;Bae, B.J.;Lee, H.S.;Lee, K.D.
    • Journal of Technologic Dentistry
    • /
    • v.19 no.1
    • /
    • pp.21-35
    • /
    • 1997
  • The Ag-Pd-Cu alloys containing a small amount of Au is commonly used for dental purposes, because this alloy is cheaper than Au-base alloys for clinical use. However, the most important characteristic of this alloy is age-hardenability, which is not exhibited by other Ag-base dental alloys. The specimens used were Ag-20Pd-20Cu ternary alloy and Au addition alloy. These alloys were melted and casted by induction electic furace and centrifugal casting machine in Ar atmoshpere. These specimens were solution treated for 2hr at $800^{\circ}C$ and were then quenched into iced water, and aged at $350{\sim}550^{\circ}C$ Age-hardening characteristics of the small Au-containing Ag-pPd-Cu dental alloys were investigated by means of hardness testing, X-ray diffraction and electron microscope observations, electrical resistance, differential scanning calorimetric, emergy dispersed spectra and electron probe microanalysis. Principal results are as follows : Hardening occured in two stages, I. e., stage I in low temperature and stage II in high temperature regions, during continuous aging. The case of hardening in stage I was due to the formation of the Llo type face centered tetragonal PdCu-ordered phase in the grain interior and hardening in stage I was affedted by the Cu concentration. In stage II, decomposition of the $\alpha$ solid solution to a PdCu ordered phase(L1o type) and an Agrich ${\alpha}2$ phase occurred and a discontiunous precipitation occurred at the grain boundary. Form the electron microscope study, it was concluded that the cause of age-hardening in this alloy is the precipitation of the PdCu ordered phase, which has AuCu I type face-centered tetragonal structure. Precipitation procedure was ${\alpha}\to{\alpha}+{\alpha}2+PdCu\to{\alpha}1+{\alpha}2+PdCu$ at Pd/Cu = 1 Ag-Pd-Cu alloy is more effective dental alloy as ageing treatment and is suitable to isothermal ageing at $450^{\circ}C$.

  • PDF

Effect of Inferior Alveolar Nerve Block Anesthesia on Taste Threshold (하치조신경 전달마취가 미각역치에 미치는 영향)

  • Ahn, Young-Joon;Kim, Seung-Whan;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.177-185
    • /
    • 2007
  • Iatrogenic injury following dental treatments and the use of local anesthetics may cause taste disorders. The aims of this study were to investigate quantitative and qualitative changes of taste due to unilateral inferior alveolar nerve block anesthesia and further to evaluate potential effects on taste function related to anesthesia or hypoesthesia of inferior alveolar nerve, possibly occurring after dental procedure. 30 healthy volunteers in their twenties participated in this study (male to female = 1:1, mean age of $24.0{\pm}1.8$ years). Each subject received inferior alveolar nerve block anesthesia on his or her right side with 2% lidocaine HCl containing 1:100,000 epinephrine. Before and after anesthesia, electrogustometric test and chemical localized test for salty, sweet, sour and bitter tastes were performed on the eight sites in the oral cavity; right and left anterior and lateral tongue and circumvallate papilla of the tongue and soft palate. Unilateral inferior alveolar nerve anesthesia produced elevation of electrical taste threshold and reduction of intensity ratings for all 4 tastes (salty, sweet, sour and bitter) over anterior and lateral tongue and circumvallate papilla on the ipsilateral side (p<0.05). Contralateral sides exhibited decreased intensity ratings for salty and sweet taste (p<0.05) on anterior and lateral tongue while there was no significant difference in electrogustometric testing. Based on the results of this study, it is assumed that unilateral local anesthesia on inferior alveolar nerve can affect chorda tympani and glossopharyngeal nerves on the same side, leading to taste deficits. Taste intensity on the contralateral side may, in part, be deteriorated as well.

Walking test for assessing lung function and exercise performance in patients with cardiopulmonary disease (심폐질환 환자에서 걷기검사를 이용한 폐기능 및 운동기능의 평가)

  • Jung, Hye Kyung;Chang, Jung Hyun;Cheon, Seon Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.976-986
    • /
    • 1996
  • BACKGROUND : Dyspnea is common among patients with cardiopulmonary disease, and "daily disability" is defined as a functional impairment resulting from exercise intolerance. The maximal oxygen uptake(VO2max) during exhausting work is not only the best single physical indicator of the capacity of a man for sustaining hard muscular work, but also the most objective method by which one can determine the physical fitness of an individual as reflected by his cardiovascular system. However, the expense, time and personnel requirements make this procedure prohibitive for testing large group. The walking test is well-known type of exercise and it cost nothing to perform and have good reproducibility. Thus we performed the walking test and investigated correlations with spirometry, ABG and exercise test. METHOD: We observed the walking test and exercise test by cycle ergometer in 37 patients who visited our hospital because of dyspnea. Arterial blood gas analysis and spiromety, dyspnea index were performed, too. RESULT : (1) The VO2max was significantly lower in patients with COPD and cardiovascular disease than asthma and dyspnea on exertion group(p<0.05). The walking test distance was also lower in former. (2) The 12 minute walking test was significantly correlated with VO2max, PaCO2, FVC(%), FEV1(%) in all patients(p<0.05), and the walking test was only conelated with VO2max in patients with COPD(p<0.05). (3) In COPD patients, the VO2max was best correlated with FEV1(%) and FVC(%) and significantly correlated with walking test. But there was no correlation between walking test and FEV1(%) & FVC(%). (4) The 6 minute walking test was well correlated with 12 minute walking test(r=0.92. p<0.01). CONCLUSION : The walking test is the simple method for assessing exercise performance in patient with cardiopulmonary disease and a reliable indicator for VO2max. And the walking test is practical method for assessing on everyday disability rather than maximal exercise capacity. The 6 minute walking test is highly correlated with 12 minute walking test and a less exhausting for the patients and a time-saving for the investigator.

  • PDF