• 제목/요약/키워드: Testing efficiency

검색결과 1,003건 처리시간 0.025초

방진마스크의 에어졸 방어효과와 밀착정도 (Protection against Aerosols by particulate Respirators and Fit Performance)

  • 한돈희
    • 한국환경보건학회지
    • /
    • 제27권2호
    • /
    • pp.30-36
    • /
    • 2001
  • This review begins with a brief expression of aerosol capture mechanism of fibrous filter(s) and performance of particulate removing respirators. The more complicated and detailed discussion is not included in this articles. Filtration efficiency and pressure drop are introduced as quality factor ( $q_{F}$) and the way in which filtration efficiency varies with particle size is discussed. Quality factors fro filters recently certified in USA were found to be very higher than those of filters made in Korea, China and USA filters certified with old certified standards. Electrically charged filters are widely used because they have high filtration efficiency and low pressure drop, but their efficiency decreases sharply at the condition occurring wet and oil mist. A discussion is given of respirator leakage through face seal and filter media with fit testing and total inward leakage testing. Since fit factor (FF) refers to the reciprocal of the fraction of the total air entering a respirator through face seal leakage , the degree of fitting performance for respirators is expected with FF. Because respirators made in Korea had generally lower FFs than respirators made in USA, it is necessary to develope respirators that fit properly for Koreans or establish regulations for fit testing.g.

  • PDF

On Testing Exponentiality Against HNRBUE Based on Goodness of Fit

  • Mahmoud, M.A.W.;Diab, L.S.
    • International Journal of Reliability and Applications
    • /
    • 제8권1호
    • /
    • pp.27-39
    • /
    • 2007
  • Based on goodness of fit new testing procedures are derived for testing exponentiality against harmonic new renewal better than used in expectation (HNRBUE). For this aging properties, a nonparametric procedure (U-statistic) is proposed. The percentiles of this test statistic are tabulated for sample sizes n=5(1)30(10)50. The Pitman asymptotic efficiency (PAE) of the test is calculated and compared with, the (PAE) of the test for new renewal better than used (NRBU) class of life distribution [see Mahmoud et al (2003)]. The power of this test is also calculated for some commonly used life distributions in reliability. The right censored data case is also studied. Finally, real examples are given to elucidate the use of the proposed test statistic in the reliability analysis.

  • PDF

A Goodness of Fit Approach for Testing NBUFR (NWUFR) and NBAFR (NWAFR) Properties

  • Mahmoud, M.A.W.;Alim, N.A. Abdul
    • International Journal of Reliability and Applications
    • /
    • 제9권2호
    • /
    • pp.125-140
    • /
    • 2008
  • The new better than used failure rate (NBUFR), Abouammoh and Ahmed (1988), and new better than average failure rate (NBAFR) Loh (1984) classes of life distributions, have been considered in the literature as natural weakenings of NBU (NWU) property. The paper considers testing exponentiality against strictly NBUFR (NBAFR) alternatives, or their duals, based on goodness of fit approach that is possible in life testing problems and that it results in simpler procedures that are asymptotically equivalent or better than standard ones. They may also have superior finite sample behavior. The asymptotic normality are proved. Powers, Pitman asymptotic efficiency and critical points are computed. Dealing with censored data case also studied. Practical applications of our tests in the medical sciences are present.

  • PDF

An Efficient Ultrasonic SAFT Imaging for Pulse-Echo Immersion Testing

  • Hu, Hongwei;Jeong, Hyunjo
    • 비파괴검사학회지
    • /
    • 제37권2호
    • /
    • pp.84-90
    • /
    • 2017
  • An ultrasonic synthetic aperture focusing technique (SAFT) using a root mean square (RMS) velocity model is proposed for pulse-echo immersion testing to improve the computational efficiency. Considering the immersion ultrasonic testing of a steel block as an example, three kinds of imaging were studied (B-Scan, SAFT imaging based on ray tracing technology and RMS velocity). The experimental results show that two kinds of SAFT imaging have almost the same imaging performance, while the efficiency of RMS velocity SAFT imaging is almost 25 times greater than the SAFT based on Snell's law.

Nonparametric Test for Used Better Than Aged in Convex Ordering Class(UBAC) of Life Distributions with Hypothesis Testing Applications

  • Abu-Youssef, S.E.
    • International Journal of Reliability and Applications
    • /
    • 제10권2호
    • /
    • pp.81-88
    • /
    • 2009
  • A non-parametric procedure is presented for testing exponentially against used better than aged in convex ordering class (UBAC) of life distributions based on u-test. Convergence of the proposed statistic to the normal distribution is proved. Selected critical values are tabulated for sample sizes 5(5)40. The Pitman asymptotic relative efficiency of my proposed test to tests of other classes is studied. An example of 40 patients suffering from blood cancer disease demonstrates practical application of the proposed test.

  • PDF

Testing NBUCA Class of Life Distribution Using U-Test

  • Al-Nachawati, H.
    • International Journal of Reliability and Applications
    • /
    • 제8권2호
    • /
    • pp.125-135
    • /
    • 2007
  • In this paper, testing exponentiality against new better than used in convex average and denote by (NBUCA), or its dual (NWUCA) is investigated through the U-test. The percentiles of these tests are tabulated for samples sizes n = 5(1)40. The power estimates of the test are simulated for some commonly used distributions in reliability. Pitman's asymptotic efficiency of the test is calculated and compared. Data of 40 patients suffering from blood cancer disease (Leukemia) is considered as a practical application of the proposed test in the medical sciences.

  • PDF

자철광 분말을 이용한 하수처리시스템의 질소, 인 제거효율에 관한 연구 (Study on the Removal Efficiency of Nitrogen and Phosphorus in Wastewater Treatment System Using Magnetite Powder)

  • 조은영;박승민;여인설;문정식;박주영;김종철;김양섭;박찬규
    • 한국유체기계학회 논문집
    • /
    • 제18권2호
    • /
    • pp.43-47
    • /
    • 2015
  • As water quality regulations have tightened, many studies to improve wastewater treatment efficiency have been performed. In this study, magnetite powder was used to maintain a high concentration of MLSS in lab-scale wastewater treatment system. After magnetite powder injection, MLSS concentration was above 8,000 mg/L and it was 3.2 times higher than control group(2,500 mg/L). In addition, nitrogen removal efficiency and phosphorus removal efficiency comparing with the control group was increased 20.5% and 11%, respectively.

Particle Filtration Efficiency Testing of Sterilization Wrap Masks

  • Chau, Destiny F.;O'Shaughnessy, Patrick;Schmitz, Michael L.
    • Journal of Preventive Medicine and Public Health
    • /
    • 제54권1호
    • /
    • pp.31-36
    • /
    • 2021
  • Objectives: Non-traditional materials are used for mask construction to address personal protective equipment shortages during the coronavirus disease 2019 (COVID-19) pandemic. Reusable masks made from surgical sterilization wrap represent such an innovative approach with social media frequently referring to them as "N95 alternatives." This material was tested for particle filtration efficiency and breathability to clarify what role they might have in infection prevention and control. Methods: A heavyweight, double layer sterilization wrap was tested when new and after 2, 4, 6, and 10 autoclave sterilizing cycles and compared with an approved N95 respirator and a surgical mask via testing procedures using a sodium chloride aerosol for N95 efficiency testing similar to 42 CFR 84.181. Pressure testing to indicate breathability was also conducted. Results: The particle filtration efficiency for the sterilization wrap ranged between 58% to 66%, with similar performance when new and after sterilizing cycles. The N95 respirator and surgical mask performed at 95% and 68% respectively. Pressure drops for the sterilization wrap, N95 and surgical mask were 10.4 mmH2O, 5.9 mmH2O, and 5.1 mmH2O, respectively, well below the National Institute for Occupational Safety and Health limits of 35 mmH2O during initial inhalation and 25 mmH2O during initial exhalation. Conclusions: The sterilization wrap's particle filtration efficiency is much lower than a N95 respirator, but falls within the range of a surgical mask, with acceptable breathability. Performance testing of non-traditional mask materials is crucial to determine potential protection efficacy and for correcting misinterpretation propagated through popular media.

Efficiency and Minimaxity of Bayes Sequential Procedures in Simple versus Simple Hypothesis Testing for General Nonregular Models

  • Hyun Sook Oh;Anirban DasGupta
    • Journal of the Korean Statistical Society
    • /
    • 제25권1호
    • /
    • pp.95-110
    • /
    • 1996
  • We consider the question of efficiency of the Bayes sequential procedure with respect to the optimal fixed sample size Bayes procedure in a simple vs. simple testing problem for data coming from a general nonregular density b(.theta.)h(x)l(x < .theta.). Efficiency is defined in two different ways in these caiculations. Also, the minimax sequential risk (and minimax sequential stratage) is studied as a function of the cost of sampling.

  • PDF

Energy Management of a Grid-connected High Power Energy Recovery Battery Testing System

  • Zhang, Ke;Long, Bo;Yoo, Cheol-Jung;Noh, Hye-Min;Chang, Young-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.839-847
    • /
    • 2016
  • Energy recovery battery testing systems (ERBTS) have been widely used in battery manufactures. All the ERBTS are connected in parallel which forms a special and complicated micro-grid system, which has the shortcomings of low energy recovery efficiency, complex grid-connected control algorithms issues for islanded detection, and complicated power circuit topology issues. To solve those shortcomings, a DC micro-grid system is proposed, the released testing energy has the priority to be reutilized between various testing system within the local grid, Compared to conventional scheme, the proposed system has the merits of a simplified power circuit topology, no needs for synchronous control, and much higher testing efficiency. The testing energy can be cycle-used inside the local micro-grid. The additional energy can be recovered to AC-grid. Numerous experimental comparison results between conventional and proposed scheme are provided to demonstrate the validity and effectiveness of the proposed technique.