• Title/Summary/Keyword: Testing Agency

Search Result 439, Processing Time 0.027 seconds

A Case Study of Quality Assurance and Control for the Soil Environmental Assessment in Abandoned Mine (광산지역 토양정밀조사 정도관리(QA/QC) 사례 연구)

  • Ji, Won Hyun;Kim, Jong Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.134-141
    • /
    • 2014
  • A testing inspection is one of the important in the industry, owing to determine the reliability and directivity of testing inspection results. Therefore, the quality assurance and quality control (QA/QC) work which performed by personnel not directly in the inventory compilation development, in testing inspection must be thoroughly considered. Some agencies for environmental test inspection, they sometimes misunderstood that the QA/QC was ended with proficiency testing performance and on-site assessment by a director. Thus, results were often calculated without QA/QC work by self manual when conducting test. The objective of this study was to improve reliability of testing and inspection agency through the QA/QC case study which basically performed to raising reliability of testing and inspection agency. In this study, it increased reliability of result by verifying calibration curve (IC, ICV, CCV), blank, accuracy (LCS, MS) and precision as QA/QC performance, while performing investigation of soil contamination in mining areas. This study suggests that reliability establishing method of test result and management method of analysis process, through the QA/QC instance of testing agency.

A Study on Improvement of Ballistic Testing Method for Combat Helmet (방탄헬멧의 방탄시험방법 개선에 관한 연구)

  • Gu, Seung Hwan;Kim, Kyung Min;Park, Jung Hwa;Song, Seung Hwan
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.2
    • /
    • pp.283-294
    • /
    • 2019
  • Purpose: Although the development of bulletproof helmets continues to be carried out, little has been improved in testing methods. Therefore, in this study, we studied the improvement of the test method of the domestic bulletproof helmet. Methods: The causes of head damage in the battlefield and the trends of bulletproof helmet development in developed countries were analyzed. In addition, improvements were derived by comparing the test methods of bulletproof helmet in Korea and the United States. Results: The results of the improvement by comparing the test methods of bulletproof helmet in Korea and the United States are as follows First, it is an addition to the scope of environmental treatment. Second, it is an addition to the level of protection. Third, the addition of the level of protection by impact. Conclusion: This study considered testing methods to prevent head injuries to shocks that cannot be identified by conventional methods. In addition, it considered testing methods for various threats by improving protection performance to advanced countries' levels.

Achievements, Problems, and Future Direction of the Quality Control Program for Special Periodic Health Examination Agencies in Republic of Korea

  • Won, Yong Lim;Ko, Kyung Sun;Park, Jae Oh;Choi, Yoon jung;Lee, Hyeji;Sung, Jung-min;Lee, Mi-young
    • Safety and Health at Work
    • /
    • v.10 no.1
    • /
    • pp.125-129
    • /
    • 2019
  • The ultimate goal of the quality control program for special periodic health examination agencies is to diagnose the health condition of a worker correctly, based on accurate examination and analysis skills, leading to protect the worker's health. The quality control program on three areas, chemical analysis for biological monitoring since 1995, and pneumoconiosis, audiometric testing since 1996, has contributed to improve the reliability of occupational health screenings by improving the issues including standardization of testing methods, tools, diagnostic opinions, and reliability of analysis for biological monitoring. It has contributed to improving the reliability of occupational health monitoring by rectifying the following issues associated with previous monitoring: absence of standardized testing methods, testing tools that are not upgraded, mismatching diagnostic opinions, and unreliable results of biological specimen analysis. Nevertheless, there are issues in need of further improvement such as lack of expertise or the use of inappropriate method for health examination, and passive and unwilling participation in the quality control. We suggested solutions to these problems for each area of quality control program. Above all, it is essential to provide active support for health examiners to develop their expertise, while encouraging all the health screening agencies, employers, and workers to develop the desire to improve the system and to maintain the relevance.

A Modal Testing of Large Naval Vessel Using Main Gun Firing Test (주포 사격시험을 이용한 대형 함정의 모달테스트)

  • Park, Mi-You;Han, Hyung-Suk;Cho, Heung-Gi;Kim, Joong-Gil;Im, Dong-Been;Lee, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • The accurate results of finite element analysis are directly related to reliability FE model which is exactly describing dynamic characteristics of target structure. So, a model updating is necessary to establish reliable FE(Finite Element) model with a lot of experience and effort using modal testing. A large structure is too difficult to obtain the dynamic characteristics owing to its weight and size. In this work, using main gun firing test, modal testing was performed to obtain dynamic characteristics of large naval vessel, which is difficult to tap the general modal testing method. The result of experiment was considered its possibility and future plans.

Small Target Detection with Clutter Rejection using Stochastic Hypothesis Testing

  • Kang, Suk-Jong;Kim, Do-Jong;Ko, Jung-Ho;Bae, Hyeon-Deok
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.12
    • /
    • pp.1559-1565
    • /
    • 2007
  • The many target-detection methods that use forward-looking infrared (FUR) images can deal with large targets measuring $70{\times}40$ pixels, utilizing their shape features. However, detection small targets is difficult because they are more obscure and there are many target-like objects. Therefore, few studies have examined how to detect small targets consisting of fewer than $30{\times}10$ pixels. This paper presents a small target detection method using clutter rejection with stochastic hypothesis testing for FLIR imagery. The proposed algorithm consists of two stages; detection and clutter rejection. In the detection stage, the mean of the input FLIR image is first removed and then the image is segmented using Otsu's method. A closing operation is also applied during the detection stage in order to merge any single targets detected separately. Then, the residual of the clutters is eliminated using statistical hypothesis testing based on the t-test. Several FLIR images are used to prove the performance of the proposed algorithm. The experimental results show that the proposed algorithm accurately detects small targets (Jess than $30{\times}10$ pixels) with a low false alarm rate compared to the center-surround difference method using the receiver operating characteristics (ROC) curve.

  • PDF

Using scratch test to evaluate cohesive bond strength of Mo composite coating

  • Koiprasert, Hathaipat;Thaiwatthana, Sirinee;Sheppard, Panadda
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.34-41
    • /
    • 2015
  • Bonding strength of a thermal sprayed coating is difficult to measure using a conventional pull-off test method. Scratch test is a potential alternative testing method. An adhesive and a cohesive bond strength of the coating can be measured by the pull-off test while the scratch test performed on the cross-section of the thermal sprayed coating can only demonstrate the cohesive bond strength of the coating. Nevertheless, it is still beneficial to perform the scratch testing on the cross-section of the coating for the sake of comparison thus providing an alternative to the pull-off test. The scratch test method can reduce testing time and cost in the long run due to a significant cost reduction in consumables and energy and time saving from the curing step of the glue used in the pull-off test. This research investigates the possibility of using the scratch test to measure the cohesive bond strength of Mo/NiCrBSi composite coating. The results from the pull-off test and the scratch test indicate that the cohesive bond strengths of the Mo composite coating show similar trend and that the cohesive bond strength are increased when increasing NiCrBSi content.

Method development for efficacy testing of veterinary disinfectants using bacteriophage MS2 (Bacteriophage MS2를 이용한 소독제 효력시험 확립에 관한 연구)

  • Rhee, Chae Hong;Kim, Soohee;Han, Bokhee;Kim, Young-Wook;Her, Moon;Jeong, Wooseog
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.3
    • /
    • pp.149-155
    • /
    • 2021
  • In virucidal efficacy testing, the chemical inactivation cannot be determined for all viruses due to the difficulties or the inability to culture sufficiently or the risk of exposure to the viruses. Therefore, disinfectants against these viruses could be evaluated by different methods and surrogate viruses are used as alternative. In this study we developed a method for efficacy testing of veterinary disinfectants using one of the candidate surrogate viruses, bacteriophage MS2, as part of the research on the selection of surrogate viruses for efficiency of efficacy testing of veterinary disinfectants. This method is based on the Animal and Plant Quarantine Agency (APQA) guidelines for efficacy testing of veterinary disinfectants. Bacteriophage and disinfectant are reacted in suspension in accordance with the APQA guidelines and then a newly established double agar layer method is applied for the efficacy test. The double agar layer method is summarized as follows: 1) The bottom agar with 1.5% agar is boiled and cooled before poured into petri dishes at volume of 20 mL, and dried under biological safety cabinet. 2) The top agar with 0.7% agar is boiled and kept at 50℃ before E. coli culture was seeded. 3) The serially diluted bacteriophage MS2-disinfectant mixtures 0.05 mL and E. coli host 0.01 mL (OD600 0.2~0.3) are mixed with 5 mL of top agar and incubate them at 50℃ for 5 min for reaction. 4) The resulting mixture is poured over top of a bottom agar plate and rocked sufficiently to ensure that the top agar covers the entire surface of the bottom agar. 5) The double agar layer is then placed under biological safety cabinet to allow the agar layer to solidify and subsequently incubated at 37℃ for 24 hr. 6) Following incubation, the plates may be inspected for plaques and record results.

Threat Analysis based Software Security Testing for preventing the Attacks to Incapacitate Security Features of Information Security Systems (보안기능의 무력화 공격을 예방하기 위한 위협분석 기반 소프트웨어 보안 테스팅)

  • Kim, Dongjin;Jeong, Youn-Sik;Yun, Gwangyeul;Yoo, Haeyoung;Cho, Seong-Je;Kim, Giyoun;Lee, Jinyoung;Kim, Hong-Geun;Lee, Taeseung;Lim, Jae-Myung;Won, Dongho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.5
    • /
    • pp.1191-1204
    • /
    • 2012
  • As attackers try to paralyze information security systems, many researchers have investigated security testing to analyze vulnerabilities of information security products. Penetration testing, a critical step in the development of any secure product, is the practice of testing a computer systems to find vulnerabilities that an attacker could exploit. Security testing like penetration testing includes gathering information about the target before the test, identifying possible entry points, attempting to break in and reporting back the findings. Therefore, to obtain maximum generality, re-usability and efficiency is very useful for efficient security testing and vulnerability hunting activities. In this paper, we propose a threat analysis based software security testing technique for evaluating that the security functionality of target products provides the properties of self-protection and non-bypassability in order to respond to attacks to incapacitate or bypass the security features of the target products. We conduct a security threat analysis to identify vulnerabilities and establish a testing strategy according to software modules and security features/functions of the target products after threat analysis to improve re-usability and efficiency of software security testing. The proposed technique consists of threat analysis and classification, selection of right strategy for security testing, and security testing. We demonstrate our technique can systematically evaluate the strength of security systems by analyzing case studies and performing security tests.

Development of the KOSHA Proficiency Testing Scheme on Asbestos Analysis in Korea

  • Kwon, Jiwoon;Jang, Konghwa;Hwang, Eunsong;Kim, Ki-Woong
    • Safety and Health at Work
    • /
    • v.8 no.3
    • /
    • pp.318-321
    • /
    • 2017
  • This commentary presents the regulatory backgrounds and development of the national proficiency testing (PT) scheme on asbestos analysis in the Republic of Korea. Since 2009, under the amended Occupational Safety and Health Act, the survey of asbestos in buildings and clearance test of asbestos removal works have been mandated to be carried out by the laboratories designated by the Ministry of Employment and Labor (MOEL) in the Republic of Korea. To assess the performance of asbestos laboratories, a PT scheme on asbestos analysis was launched by the Korea Occupational Safety and Health Agency (KOSHA) on behalf of the MOEL in 2007. Participating laboratories are evaluated once a year for fiber counting and bulk asbestos analysis by phase contrast microscopy and polarized light microscopy, respectively. Currently, the number of laboratory enrollments is > 200, and the percentage of passed laboratories is > 90. The current status and several significant changes in operation, sample preparations, and statistics of assigning the reference values of the KOSHA PT scheme on asbestos analysis are presented. Critical retrospect based on the experiences of operating the KOSHA PT scheme suggests considerations for developing a new national PT scheme for asbestos analysis.