• 제목/요약/키워드: Tester System

검색결과 441건 처리시간 0.028초

차세대 소형위성 1호 충격시험 계측/분석 프로그램 개발 (Development of Shock Test Measurement/Analysis Program for NEXTSat-1)

  • 성태현;진재현;김상균
    • 항공우주시스템공학회지
    • /
    • 제10권2호
    • /
    • pp.34-40
    • /
    • 2016
  • A satellite is exposed to various impact environment until orbit entry. It is particularly undergoing the biggest impact by pyro shock, which is generated when the launch vehicle stages are separated or the satellite is separated from the launch vehicle. In this paper, due to the fact that the pyro shock is prerequisite for performing the test and verification on the ground, we developed an air-gun type shock tester for NEXTSat-1 shock test at the KAIST SaTReC along with the development of program introduced by LabVIEW software. The program operated in shock tester is consist of data measurement and analysis with the convenient implementation of user interface and its easy modification of the code.

자동제어계측을 이용한 송풍기 성능시험 (Fan Performance Test with Automatic Control and Measurement)

  • 최영석;김진권
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.373-378
    • /
    • 2003
  • In this paper, build up of fan performance tester in KITECH was introduced. The fan tester was set up based on AMCA standards 210-99, ANSI/ASHRAE 51-1999 with maximum flowrate within $1000\;m^{3}/min$. Both of inlet and outlet chamber setup with multiple nozzles described in AMCA 210 were established. The development of fully automatic control and measurement system are described. With this system, the accuracy of fan performance test can be maintained through the various flowrate and the uncertainty can be reduced.

  • PDF

Fan 냉각장치에서 System 저항에 관한 수치해석 (A Numerical Analysis on the System Impedance in a Fan Cooling System)

  • 김동일;복기소;이승규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1424-1429
    • /
    • 2004
  • To seek the fan operating point on a cooling system with fans, it is very important to determine the system impedance and it has been usually examined with the fan tester(wind tunnel) based on ASHRAE standard and AMCA standard. This leads to a large investment in time and cost, because it could not be executed until the system is made actually. Therefore it is necessary to predict the system impedance curve through numerical analysis so that we could reduce the measurement effort. This paper presents how the system impedance curve (pressure drop curve) is computed by CFD in substitute for experiment. In reverse order to the experimental principle of the fan tester, pressure difference was adopted first as inlet and outlet boundary conditions of the system and then flow rate was calculated.

  • PDF

마샬 안정도시험기를 이용한 아스팔트 혼합물의 파괴에너지 측정시스템 개발 (Development of Fracture Energy Measurement System of Asphalt Mixture Using Marshall Tester)

  • 김부일;이문섭
    • 한국도로학회논문집
    • /
    • 제11권1호
    • /
    • pp.135-144
    • /
    • 2009
  • 본 연구는 마샬 시험기를 이용하여 아스팔트 혼합물의 균열저항성을 평가할 수 있는 보다 간편하고 합리적인 측정시스템을 개발하는데 목적이 있다. 균열저항성 평가를 위한 파라메타로서 파괴에너지를 이용하였다. 마샬 시험기는 기본적으로 공시체 외부에 거치한 LVDT를 이용하여 수직변형률을 측정하는 시스템이며, 이 같은 외부 수직변형률 측정방식은 하중 스트랩 부분에서 발생하는 국부적인 변형으로 인해 측정오차를 야기할 가능성이 있다. 따라서 추가적인 계측 시스템을 설치하지 않고 기본적인 마샬 시험기를 이용하여 혼합물의 파괴에너지를 측정하기 위해서는 공시체 외부에 거치한 LVDT를 이용한 수직변형률 측정값이 파괴에너지 산정에 적용가능한지 여부를 검증하여야 한다. 이를 위해 본 연구에서는 공시체 중앙부분에서의 수평변형률과 외부에 거치한 LVDT를 이용한 수직변형률을 측정하는 두 가지 방식의 간접인장강도실험을 수행하여 그 차이를 비교 분석하였다. 실험결과, 외부 수직변형률 측정의 문제점으로 지적되었던 하중 스트랩 부분에서 발생하는 국부적인 변형은 파괴시점 이전에는 극히 적은 것으로 나타나 파괴에너지 계산에 오차를 유발하지 않음을 보여주었다. 또한 외부 수직변형률 측정의 실험변동성을 확인한 결과, 변동계수가 15% 이하로 마샬시험기를 이용한 균열저항성 평가시스템에 이용 가능함을 알 수 있었다.

  • PDF

A Study on the Fabric Drape Evaluation Using a 3D Scanning System Based on Depth Camera with Elevating Device

  • Kim, Jongjun
    • 패션비즈니스
    • /
    • 제19권6호
    • /
    • pp.28-41
    • /
    • 2015
  • Properties of textile fabrics influence the appearance, aesthetics, and performance of garment. Drape and related properties of fabrics affect profoundly the static and dynamic appearance during wearer's movement. The three dimensional shape of the folded structure often deforms with time or with subtle vibration around the fabric specimen during the drape measurement. Due to the uneven and complex nature of fabrics, the overall shape of the fabric specimen on the drape tester often becomes unstable. There is a need to understand the fundamental mechanisms of how draping may generate pleasing forms. Two drape test methods, conventional Cusick drape test, and in-built drape tester, based on a depth camera, are compared. Fabric specimens including cotton, linen, silk, wool, polyester, and rayon are investigated for the fabric drape and other physical/mechanical parameters. Drape coefficient values of fabric specimens are compared based on the final drape images, together with the intermediate 3D drape images of the specimens during elevation process of the drape tester equipped with a stepper motor system. The correlation coefficient between the data based on the two methods is reasonably high. Another advantage from the depth camera system is that it allows further analysis of three-dimensional information regarding the fabric drape shape, including the shape of nodes or crest and trough.

Check4Urine: 스마트폰 기반 휴대용 소변검사 시스템 (Check4Urine: Smartphone-based Portable Urine-analysis System)

  • 조중재;유준혁
    • 대한임베디드공학회논문지
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 2015
  • Recently, a few image-processing based mobile urine testers have actively been studied since the urine-analysis result can be available to the user in real time immediately after the test is done. However, the accuracy of test result can be severely degraded due to variable illumination environments and a variety of manners to capture the image with a camera embedded in the smartphone according to different users. This paper proposes the Check4Urine system, a novel smartphone-based portable urine-analysis tester and provides three techniques to improve such a performance degradation problem robust to various test environments and disturbances, which are the compensation algorithm to correct the varying illumination effect, an urine strip detection algorithm robust to edge loss of the object image, and the color decision algorithm based on the pre-processed reference table. Experimental results show that the proposed Check4Urine system increases the accuracy of urine-analysis by 20-50% at various test conditions, compared with the existing image-processing based mobile urine tester.

전기자동차용 2차전지를 위한 스마트 ICT형 전자식 외부 단락시험기 개발 (Development of Smart ICT-Type Electronic External Short Circuit Tester for Secondary Batteries for Electric Vehicles)

  • 정태욱;신병철
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.333-340
    • /
    • 2022
  • Recently, the use of large-capacity secondary batteries for electric vehicles is rapidly increasing, and accordingly, the demand for technologies and equipment for battery reliability evaluation is increasing significantly. The existing short circuit test equipment for evaluating the stability of the existing secondary battery consists of relays, MCs, and switches, so when a large current is energized during a short circuit, contact fusion failures occur frequently, resulting in high equipment maintenance and repair costs. There was a disadvantage that repeated testing was impossible. In this paper, we developed an electronic short circuit test device that realizes stable switching operation when a large-capacity power semiconductor switch is energized with a large current, and applied smart ICT technology to this electronic short circuit stability test system to achieve high speed and high precision through communication with the master. It is expected that the inspection history management system based on data measurement, database format and user interface will be utilized as essential inspection process equipment.

비파괴적인 재료물성치 평가에 관한 연구 (A Study on the Nondestructive Evaluation of Material Properties)

  • 김형익;김정표;석창성
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.130-136
    • /
    • 2005
  • The nondestructive evaluation system consisted of a ball indentation tester and a ultrasonic tester was developed to evaluate material properties. The relations between the parameters from test results using the system and the results of tensile and fracture toughness tests were investigated. The fracture toughness and tensile properties could be determined using the system. Some metallic materials were experimented to predict the fracture toughness and tensile properties and verify the relations between them. The predicted fracture toughness and tensile properties show a good agreement with the results obtained by conventional tests. It is found that the material properties and the material degradation can be evaluated using the nondestructive evaluation system.

A Study on the Usefulness of Development of a Steam Sterilizer Equipped with an Electronic Bowie-Dick Test System

  • Bae, Young Ok;Hwang, Jun Soo;Kim, Sung Il;Lee, Joon Ha
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.156-163
    • /
    • 2017
  • To verify the usefulness of a steam sterilizer equipped with an electronic Bowie-Dick test system, this study was carried out using two methods, utilizing both a steam sterilizer and an electronic Bowie-Dick tester. The first method is to confirm the error detection of the chemical Bowie-Dick test pack and the electronic Bowie-Dick tester in a malfunctioning sterilizer environment. For this purpose, the Bowie-Dick test program for the steam sterilizer was used to test three types of test packs commonly used in hospitals and the electronic Bowie-Dick tester by changing the set values of temperature, time, and vacuum frequency. The second is an experiment to check the sterilizer's normal operation with the electronic Bowie-Dick tester and the usefulness of grasping the cause of the malfunction. The results showed that the sterilization temperature was the same as that of the test pack at a temperature $1{\sim}6^{\circ}C$ lower than the reference temperature of $134^{\circ}C$. In the test with the sterilization exposure time as a variable, there was a normal discoloration at a time difference of 30~90 s. In the experiment using the number of vacuum cycles, the test was correct by performing the normal discoloration only at the normal condition of 3 times. The test results of 30 hospitals were 100 failure tests by a total of 291 Bowie-Dick tests. Of these, the failure factors related to an internal temperature that the chemical test packs could not detect were the greatest, and the four factors related to temperature, including the internal temperature, were found to be 71.18% of total malfunctions. In addition, the Bowie-Dick tester was provided within 30 min after the start of the Bowie-Dick test to confirm the performance of the sterilizer and the detailed cause. A steam sterilizer equipped with an electronic Bowie-Dick test system is used to manage individual sterilizers. In the current steam sterilizer with many temperature-related errors, it is possible to check the malfunction of the temperature difference that the test pack cannot detect, and the cause of error for the sterilizer is immediately detected after the test. The steam sterilizer equipped with the electronic Bowie-Dick test system assists with infection control with accurate sterilizer performance assurance.