• 제목/요약/키워드: Test-setup

검색결과 374건 처리시간 0.027초

자동제어계측을 이용한 송풍기 성능시험 (Fan Performance Test with Automatic Control and Measurement)

  • 최영석;김진권
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.373-378
    • /
    • 2003
  • In this paper, build up of fan performance tester in KITECH was introduced. The fan tester was set up based on AMCA standards 210-99, ANSI/ASHRAE 51-1999 with maximum flowrate within $1000\;m^{3}/min$. Both of inlet and outlet chamber setup with multiple nozzles described in AMCA 210 were established. The development of fully automatic control and measurement system are described. With this system, the accuracy of fan performance test can be maintained through the various flowrate and the uncertainty can be reduced.

  • PDF

무기체계 실사격 시험의 시스템공학 적용 (Systems Engineering based Live Fire Test of Weapon Systems)

  • 유병직;황규환;류충호;김문기;예성혁;한욱상
    • 한국군사과학기술학회지
    • /
    • 제15권1호
    • /
    • pp.28-35
    • /
    • 2012
  • We propose the live fire test process model based on systems engineering which consists of 4 phases i.e., review, setup, conduct and result. We also suggest the 4 phases acquisition model consisting of planning, execution, evaluation and disposal for test infrastructure. CMMI, TMMi and PMBOK are referred and hierarchial analysis method are adopted in developing the models. Thus, the detailed sub-processes are designed after defining higher level processes first. The higher level processes are defined by extracting common areas of all the test types. The low level processes for each specific test are designed by tailoring the higher level processes. By applying the proposed test process models into collaboration tool and information system, effective and systematic test processes for weapon systems are established.

MMC 기반 STATCOM 용 밸브의 성능시험 장치를 위한 새로운 토폴로지 (New Topology for Valve Performance Test Equipment of MMC based STATCOM)

  • 배종우;정재헌;노의철;정용호;백승택;이진희;김영우
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.82-88
    • /
    • 2017
  • This study proposes a new topology for the performance test of a valve consisting of a modular multilevel converter (MMC)-based static synchronous compensator (STATCOM). The conventional valve performance test equipment requires high-voltage AC source of several kV rating because the number of submodules to be tested in a valve should be at least six or eight. However, the power source of the proposed scheme is DC and not AC source. The DC power source voltage range of the proposed test circuit is from several volts to several tens of volts. Therefore, the size and cost for the performance test equipment can be reduced considerably compared with the conventional method. The proposed scheme satisfies the requirements of the IEC 62927 standard. Simulations are conducted for a valve of 50[MVA] MMC-based STATCOM. Experimental results with a scale-downed setup show the validity of the proposed performance test topology.

모바일 스마트 단말을 활용한 실시간 멀티미디어 스트리밍 서비스 개발 (Development of Realtime Multimedia Streaming Service using Mobile Smart Devices)

  • 박미룡;심한억
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권4호
    • /
    • pp.51-56
    • /
    • 2014
  • 스마트 단말이 생활 저변에 확대된 시대에 스마트 단말의 다양한 센서들을 활용한 응용 서비스들의 연구 개발이 진행되고 있다. 스마트 단말에는 주변 환경을 수집할 수 있는 카메라, GPS, 마이크, 및 통신 모듈이 포함되어 있으며 이들을 이용한 응용서비스들은 사용자 중심의 컨텐츠 개발로 확산되고 있다. 본 논문에서는 다양한 센서들이 포함되어 있는 스마트 단말에서 다중 사용자에게 실시간 멀티미디어 스트림 전송을 위해 실시간 스트리밍 서비스 아키텍처를 설계하고, 동시 다중 사용자들을 수용하기 위한 백엔드 분산 서버 구조, 실시간 스트리밍과 미디어 저장 등을 처리하며, 설계된 아키텍처 기반으로 오픈소스 기반 단말용 앱과 서버를 통해 동작을 시험한다. 시험을 통해 초기 멀티미디어용 SIP(Session Initiation Protocol)의 호 연결지연과 미디어 스트리밍 전송 지연 및 종단간 플레이 타임 등을 측정하며, 측정 결과 국내에서는 모바일 환경에서 실시간 멀티미디어 서비스를 하기에 부족함이 없는 망 상황으로, 향후 초기 호 연결 지연시간을 단축시켜 종단간 플레이 타임을 향상시켜야 한다.

불균형 휨모멘트를 받는 플랫플레이트-기둥 접합부의 편심전단강도 (Strength Model for Eccentric Shear of Flat Plate-Column Connections under Unbalanced Moment)

  • 최경규;박홍근
    • 콘크리트학회논문집
    • /
    • 제16권2호
    • /
    • pp.229-240
    • /
    • 2004
  • 불균형 휨모멘트를 재하받는 플랫플레이트-기둥 접합부의 편심전단강도와 모멘트강도를 규명하기 위해 그동안 많은 실험연구가 수행되어 왔다. 기존 실험들은 서로 다른 실험방식을 사용하고 있는데, 접합부의 전단강도는 실험방식에 따라 차이가 있는 것으로 나타났다. 따라서 기존 실험에 근거하여 개발된 현행 설계기준들은 플랫플레이트의 강도를 정확히 설명하고 있지 못한 실정이다. 선행 연구에서는 연속 플랫플레이트에 대한 비선형 유한요소해석에 근거하여, 슬래브-기둥 접합부에 패한 새로운 설계방법을 개발하였다. 그러나 제안된 설계방법에서는 휨모멘트 강도산정에 필요한 접합부 편심강도를 경험식에 의존하여 산정하고 있다. 본 연구에서는, 접합부 파괴 메카니즘을 분석하기 위해서, Rankine 재료파괴기준을 이용하는 이론적인 접근법을 채택하였다. 분석결과에 근거하여 개선된 편심전단강도모델이 개발되었고, 기존 실험과의 비교를 통해 검증되었다. 개발된 강도식을 이용하여, 선행연구에서 개발된 설계방법을 재검증하였다.

Positional uncertainties of cervical and upper thoracic spine in stereotactic body radiotherapy with thermoplastic mask immobilization

  • Jeon, Seung Hyuck;Kim, Jin Ho
    • Radiation Oncology Journal
    • /
    • 제36권2호
    • /
    • pp.122-128
    • /
    • 2018
  • Purpose: To investigate positional uncertainty and its correlation with clinical parameters in spine stereotactic body radiotherapy (SBRT) using thermoplastic mask (TM) immobilization. Materials and Methods: A total of 21 patients who underwent spine SBRT for cervical or upper thoracic spinal lesions were retrospectively analyzed. All patients were treated with image guidance using cone beam computed tomography (CBCT) and 4 degrees-of-freedom (DoF) positional correction. Initial, pre-treatment, and post-treatment CBCTs were analyzed. Setup error (SE), pre-treatment residual error (preRE), post-treatment residual error (postRE), intrafraction motion before treatment (IM1), and intrafraction motion during treatment (IM2) were determined from 6 DoF manual rigid registration. Results: The three-dimensional (3D) magnitudes of translational uncertainties (mean ${\pm}$ 2 standard deviation) were $3.7{\pm}3.5mm$ (SE), $0.9{\pm}0.9mm$ (preRE), $1.2{\pm}1.5mm$ (postRE), $1.4{\pm}2.4mm$ (IM1), and $0.9{\pm}1.0mm$ (IM2), and average angular differences were $1.1^{\circ}{\pm}1.2^{\circ}$ (SE), $0.9^{\circ}{\pm}1.1^{\circ}$ (preRE), $0.9^{\circ}{\pm}1.1^{\circ}$ (postRE), $0.6^{\circ}{\pm}0.9^{\circ}$ (IM1), and $0.5^{\circ}{\pm}0.5^{\circ}$ (IM2). The 3D magnitude of SE, preRE, postRE, IM1, and IM2 exceeded 2 mm in 18, 0, 3, 3, and 1 patients, respectively. No association were found between all positional uncertainties and body mass index, pain score, and treatment location (p > 0.05, Mann-Whitney test). There was a tendency of intrafraction motion to increase with overall treatment time; however, the correlation was not statistically significant (p > 0.05, Spearman rank correlation test). Conclusion: In spine SBRT using TM immobilization, CBCT and 4 DoF alignment correction, a minimum residual translational uncertainty was 2 mm. Shortening overall treatment time and 6 DoF positional correction may further reduce positional uncertainties.

두경부환자의 토모테라피 치료시 SETUP 변화율에 대한 후향적 평가 (After retrospective evaluation of the SETUP rate change during the treatment of head and neck cancer patient with Helical Tomotherapy)

  • 하태영;김승준;황철환;손종기
    • 대한방사선치료학회지
    • /
    • 제28권1호
    • /
    • pp.27-34
    • /
    • 2016
  • 목 적 : 두경부 환자 토모 치료 시 위치 보정한 좌표값을 이용한 환자의 Setup 변화율을 후향적 평가를 하고자 한다. 재료 및 방법 : 2010년 01월에서 2012년12월까지 토모테라피 치료를 받은 두경부 환자 중 무작위(95)로 샘플링하여 3그룹으로 정리하였다. 그룹 1(32)Brain, 그룹2(28)Maxillar, Nasal cavity, 그룹3(35) Nosopharynx(NPX), Tongue, Tonsil, Oropharynx(OPX)로 분류하였다. 3그룹 간에 있어 X 축, Y 축, Z 축 오차, Roll, 체중변화, Vector를 변수로 하여, 30회 치료기간 중 반복측정에 의한 통계적 검정을 시행하였다. 결 과 : 통계적 검정 결과 fraction에 따른 차이는 x축(p=0.458), y축(0.989)은 차이가 없었으며 z축(p=0.001), roll(p=0.037), 체중변화(p<0.001), Vector(p<0.001)은 차이가 있는 것으로 나타났다. 또한 fraction에 따라 3그룹간의 패턴은 x축(p=0.430), roll(p=0.299)은 차이가 없었으며 y축(0.023), y축(0.023), 체중변화(p=0.001), Vector(p=0.028)은 차이가 있는 것으로 나타났다. 결 론 : 후향적 평가를 시행한 결과 그룹3즉, Y, Z, 체중변화, Vector 변화에 대하여 알 수 있었고 Low neck을 포함한 치료 시 Random error가 커짐을 통계적 알 수 있었다.

  • PDF

A Melon Fruit Grading Machine Using a Miniature VIS/NIR Spectrometer: 2. Design Factors for Optimal Interactance Measurement Setup

  • Suh, Sang-Ryong;Lee, Kyeong-Hwan;Yu, Seung-Hwa;Shin, Hwa-Sun;Yoo, Soo-Nam;Choi, Yong-Soo
    • Journal of Biosystems Engineering
    • /
    • 제37권3호
    • /
    • pp.177-183
    • /
    • 2012
  • Purpose: In near infrared spectroscopy, interactance configuration of a light source and a spectrometer probe can provide more information regarding fruit internal attributes, compared to reflectance and transmittance configuration. However, there is no through study on the parameters of interactance measurement setup. The objective of this study was to investigate the effect of the parameters on the estimation of soluble solids content (SSC) and firmness of muskmelons. Methods: Melon samples were taken from greenhouses at three different harvesting seasons. The prediction models were developed at three distances of 2, 5, and 8 cm between the light source and the spectrometer probe, three measurement points of 2, 3, and 6 evenly distributed on each sample, and different number of fruit samples for calibration models. The performance of the models was compared. Results: In the test at the three distances, the best results were found at a 5 cm distance. The coefficient of determination ($R_{cv}{^2}$) values of the cross-validation were 0.717 (standard error of prediction, SEP=$1.16^{\circ}Brix$) and 0.504 (SEP=4.31 N) for the estimation of SSC and firmness, respectively. The minimum measurement point required to fully represent the spectral characteristics of each fruit sample was 3. The highest $R_{cv}{^2}$ values were 0.736 (SEP=$0.87^{\circ}Brix$) and 0.644 (SEP=4.16 N) for the estimation of SSC and firmness, respectively. The performance of the models began to be saturated when 60 fruit samples were used for developing calibration models. The highest $R_{cv}{^2}$ of 0.713 (SEP=$0.88^{\circ}Brix$) and 0.750 (SEP=3.30 N) for the estimation of SSC and firmness, respectively, were achieved. Conclusions: The performance of the prediction models was quite different according to the condition of interactance measurement setup. In designing a fruit grading machine with interactance configuration, the parameters for interactance measurement setup should be chosen carefully.

Immunity Test for Semiconductor Integrated Circuits Considering Power Transfer Efficiency of the Bulk Current Injection Method

  • Kim, NaHyun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권2호
    • /
    • pp.202-211
    • /
    • 2014
  • The bulk current injection (BCI) and direct power injection (DPI) method have been established as the standards for the electromagnetic susceptibility (EMS) test. Because the BCI test uses a probe to inject magnetically coupled electromagnetic (EM) noise, there is a significant difference between the power supplied by the radio frequency (RF) generator and that transferred to the integrated circuit (IC). Thus, the immunity estimated by the forward power cannot show the susceptibility of the IC itself. This paper derives the real injected power at the failure point of the IC using the power transfer efficiency of the BCI method. We propose and mathematically derive the power transfer efficiency based on equivalent circuit models representing the BCI test setup. The BCI test is performed on I/O buffers with and without decoupling capacitors, and their immunities are evaluated based on the traditional forward power and the real injected power proposed in this work. The real injected power shows the actual noise power level that the IC can tolerate. Using the real injected power as an indicator for the EMS test, we show that the on-chip decoupling capacitor enhances the EM noise immunity.

나로호 킥모터 TVC 노즐 행정확인시험 및 특성 분석 (Stroke Verification Test and Operational Characteristics Analysis of KSLV-I Kick Motor TVC Nozzle)

  • 선병찬;박용규;오충석;노웅래
    • 항공우주기술
    • /
    • 제11권1호
    • /
    • pp.158-168
    • /
    • 2012
  • 본 논문에서는 나로호 2단 킥모터 TVC 노즐에 대한 행정확인시험 방법과 행정확인시험 데이터로부터 TVC 운용 특성을 분석하는 과정 및 결과에 대해 다루었다. 개루프 행정확인 시험을 통해 TVC 스트로크와 포텐셔미터 전압 간의 관계를 분석하고, 폐루프 행정확인시험을 통해 노즐정렬오차, TVC 구동오차, TVC 중립위치, 플렉스씰 노즐의 회전중심위치, 비행시험후 분석에 사용할 노즐각 환산계수 등을 분석할 수 있음을 보였다. 아울러, 나로호 1호기 및 2호기 TVC 시스템에 대해 행정확인시험을 수행한 결과 TVC 운용 관련 모든 파라미터가 정상 범위 내에서 설정되었음을 정량적인 수치로써 제시하였다.