• 제목/요약/키워드: Test station

검색결과 1,145건 처리시간 0.025초

ANALYSIS OF A STATION BLACKOUT SCENARIO WITH AN ATLAS TEST

  • Kim, Yeon-Sik;Yu, Xin-Guo;Kang, Kyoung-Ho;Park, Hyun-Sik;Cho, Seok;Choi, Ki-Yong
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.179-190
    • /
    • 2013
  • A station blackout experiment called SBO-01 was performed at the ATLAS facility. From the SBO-01 test, the station blackout scenario can be characterized into two typical phases: A first phase characterized by decay heat removal through secondary safety valves until the SG dryouts, and a second phase characterized by an energy release through a blowdown of the primary system after the SG dryouts. During the second phase, some physical phenomena of the change over a pressurizer function, i.e., the pressurizer being full before the POSRV $1^{st}$ opening and then its function being taken by the RV, and the termination of normal natural circulation flow were identified. Finally, a core heatup occurred at a low core water level, although under a significant amount of PZR inventory, whose drainage seemed to be hindered owing to the pressurizer function by the RV. The transient of SBO-01 is well reproduced in the calculation using the MARS code.

Interpretation of Varietal Response to Rice Leaf Blast by G$\times$E Analysis with Reduced Number of Nursery Test Sites

  • Yang, Chang-Ihn;E. L. Javier;Won, Yong-Jae;Yang, Sae-Jun;Park, Hae-Chune;Shin, Young-Boum
    • 한국작물학회지
    • /
    • 제45권5호
    • /
    • pp.316-321
    • /
    • 2000
  • Blast severity data of 39 rice varieties at 11 sites in Korea from 1997 to 1999 were analyzed using AMMI model and pattern analysis. Genotype x Environment (G$\times$E) interaction sum of squares (SS) accounted for 12 % of the total SS. Eight genotype groups and seven location groups were identified based on blast reaction pattern. The data obtained from over 21 sites with 44 test varieties from 1981 to 1996 were also considered. These were compared with the 1997-1999 data using the G$\times$E analysis results. Majority of the variability in the Korean Rice Blast Nursery (KRBN) were attributable to variations due to genotypes. Variations of G$\times$E interaction were maintained though test sites were reduced from 21 to 11 sites. Broadly compatible biological discriminative varieties identified were Nagdongbyeo and Akibare while broadly incompatible biological discriminative varieties identified were Hangangchalbyeo and Seogwangbyeo. Key sites for future evaluation work could be selected from location groups. Each location group should be represented by the site with the strongest interaction pattern. Blast responses in Cheolwon, Gyehwa, Suwon, Iksan, and Icheon showed different patterns from other locations.

  • PDF

Fusarium Fruit Rot of Citrus in Jeju Island

  • Hyun, Jae-Wook;Lee, Seong-Chan;Kim, Dong-Hwan;Ko, Sang-Wook;Kim, Kwang-Sik
    • Mycobiology
    • /
    • 제28권3호
    • /
    • pp.158-162
    • /
    • 2000
  • Twenty-three isolates of Fusarium spp. were obtained from decayed citrus fruits in the fields and storages in 1998-1999. Of them, six and five isolates belonged to F. proliferatum and F. moniliforme, respectively, which were the most common. F. solani and F. sambucinum had each two isolates, F. equiseti had one isolate and seven isolates were unidentified. They produced symptoms of two types in pathogenicity test: those with leathery, beige to light or dark brown, and sunken lesions without surface mycelium (type-1) and those with lesions covered with white, beige or pink surface mycelium (type-2). Four of six isolates identified to F. proliferatum and two unidentified isolates produced type-1 lesions, and all isolates identified to F. moniliforme, F. solani, F. sambucinum, F. equiseti and five unidentified isolates produced type-2 lesions.

  • PDF

Studies on Physiology, Ecology and Protection of Citrus Canker Caused by Xanthomonas axonopodis pv, citri

  • Lee, Seong-Chan;Hyun, Jae-Wook;Kim, Dong-Hwan;Kim, Kwang-Sik;Lim, Han-Chul
    • 한국식물병리학회:학술대회논문집
    • /
    • 한국식물병리학회 2003년도 정기총회 및 추계학술발표회
    • /
    • pp.124-124
    • /
    • 2003
  • Citrus canker is very important disease in international trade of citrus. The disease was usually take place from late of June, and severe middle of July to middle of August, though disease occurrence was affected by environmental conditions. In pathogenicity test, three varieties, orange, lemon and kiyomi among 7 varieties, were succeptible, two varieties, satsuma mandarin and iwasachi, intermediate resistant. On the other hand, shiranuhi and yuzu were resistant relatively. The pathogen, Xanthomonas axonopodis pv. citri, grew well in PD broth adjusted to pH 7.0 at 26$^{\circ}C$. It's growth was best in medium containing group of monosaccharide as a carbon source and group of ammonium as a nitrogen source. Tow isolates were resistant to streptomycin among 11 isolates isolated from diseased leaves in field in Jeju-Do. The streptomycin sensitives isolate was controlled by in greenhouse test. On the other hand, the resistant and sensitive isolates were controlled by treatment with copper sulfate, the control value is 88.7% and 90.6%, respectively.

  • PDF

과학기술위성2호 관제를 위한 Ground station Baseband Controller(GBC) 개발 (Ground station Baseband Controller(GBC) Development of STSAT-2)

  • 오대수;오승한;박홍영;김경희;차원호;임철우
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권8호
    • /
    • pp.482-485
    • /
    • 2005
  • STSAT-2 is first satellite which is scheduled to launch by first Korea launcher. Ground station Baseband Controller(GBC) for operating STSAT-2 is now developing. GBC control data flow path between satellite operation computers and ground station antennas and count number of received data packets among demodulated audio signals from three antennas and also set data flow path to good-receiving antenna automatically In GBC two uplink FSK modulators(1.2kbps, 9.6kbps) and six downlink FSK demodulators(9.6kbps, 38.4kbps) are embedded. STSAT-2 GBC hardware is more simpler than STSAT-1 GBC by using FPGA in which all digital logic implemented. Now test and debugging of GBC hardware and Software(FPGA Code and CBC Manager Program) is well progressing in SaTReC, KAIST. This paper introduce GBC structure, functions and test results.

과학기술위성2호 관제를 위한 Ground station Baseband Controller(GBC) 개발 (Ground station Baseband Controller(GBC) Development of STSAT-2)

  • 오대수;오승한;박홍영;김경희;차원호;임철우;유창완;황동환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.116-118
    • /
    • 2005
  • STSAT-2 is first satellite which is scheduled to launch by first Korea launcher. After launch Ground station Baseband Controller(GBC) for operating STSAT-2 is now developing. GBC control data flow path between satellite operation computers and ground station antennas. and GBC count number of received data packets among demodulated audio signals from three antennas and set data flow path to good-receiving antenna automatically. In GBC two uplink FSK modulators(1.2kbps, 9.6kbps) and six downlink FSK demodulators(9.6kbps, 38.4kbps) are embedded. STSAT-2 GBC hardware is more simpler than STSAT-1 GBC by using FPGA in which all digital logic implemented. Now test and debugging of GBC hardware and Software(FPGA Code and GBC Manager Program) is well progressing in SaTReC, KAIST. This paper introduce GBC structure, functions and test results.

  • PDF

FACTORS INFLUENCING FEED EFFICIENCY AND BACKFAT THICKNESS IN STATION TESTED BEEF BULLS

  • Liu, M.F.;Makarechian, M.;Price, M.A.;Huedepohl, C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제8권5호
    • /
    • pp.495-498
    • /
    • 1995
  • Records taken on 372 young beef bulls tested at the Ellerslie Bull Test Station, Alberta, Canada from November 1981 to April 1987 were analyzed to quantify the effects of age of dam, on-test age, on-test liveweight and herd of origin of bull on feed efficiency (feed/gain, kg/kg) in the test period (n = 231) and ultrasonic measurement of bakcfat thickness (mm) at the end of the test (n = 372). The reduction in $R^2$ due to each influencing factor (i.e. the variation accounted for by the factor) was used to indicate the importance of the influencing factor. Age of dam and on-test age of bull were not important factors on feed/gain and ultrasonic backfat thickness, as they accounted for less than 0.5% of the variation in feed/gain and ultrasonic backfat thickness, respectively (p > 0.1). On-test liveweight had some influence on feed/gain and ultrasonic backfat thickness, accounting for 3.5% (p < 0.01) and 0.4% (p < 0.05) of the total variation, respectively. The regression coefficients of feed/gain and ultrasonic backfat thickness on on-test liveweight were 0.016 (kg/kg)/kg and .013 mm/kg, respectively, both being significant (p < 0.05), indicating that lighter bulls entering the test were generally more efficient in feed utilization in the test period and had less backfat at the end of the test than heavier entering bulls. Herd of origin of bull accounted for a substantial amount of the total variation (> 16%) in feed/gain and ultrasonic backfat thickness (p = 0.08), indicating that a prolonged aqjustment period was needed to reduce the influence of herd of origin when assessing aggregate genetic merit of beef bulls for growth rate, feed efficiency and lean meat production using a central station performance testing program.

Incorporating Station Related Aging Failures in Bulk System Reliability Analysis

  • Billinton Roy;Yang Hua
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.322-330
    • /
    • 2005
  • This paper proposes methods to incorporate station related aging failures in composite system reliability assessment. Aging failures of station components, such as circuit breakers and bus bars, are a major concern in composite power system planning and operation as an increasing number of station components approach the wear-out phase. This paper presents probabilistic models for circuit breakers involving aging failures and relevant evaluation techniques to examine the effects of station related aging outages. The technique developed to incorporate station related aging failures are illustrated by application to a small composite test system. The paper illustrates the effects of circuit breaker aging outages on bulk system reliability evaluation and examines the relative effects of variations in component age. System sensitivity analysis is illustrated by varying selected component parameters. The results show the implications of including component aging failure considerations in the overall analysis of a composite system.

과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안 (The Plan of Safety for Pump Station through Hydraulic Transient Analysis & Demonstration)

  • 라병필;김진만;박종호;김경엽
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.199-207
    • /
    • 2004
  • Water supply facilities are recently getting larger according as domestic waterworks become multi regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment station and water supply & distribution facilities. Although pumping stations and pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. As a result of this study, a pumping station is guaranteed by the computer simulation and field test analysis. Therefore these are contributed safety operation in pumping station through adjustment of the pumping station safety plan, air valve and valve closing time.

  • PDF

신재생에너지를 이용한 철도역사용 복합형 가로등 설계 (Design of Hybrid Type Streetlight for Railway Station with Renewable Energy)

  • 윤용호;김재문
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2103-2108
    • /
    • 2016
  • Energy saving is as important as developments of green energy and alternative energy. This paper describes design of hybrid type streetlight for railway station with renewable energy as photovoltaic, wind, secondary battery. In designing hybrid type streetlight for railway station, generation energy with renewable energy and reliability is strongly needed to meet the demand of railway station. In order to achieve the high performance of a streetlight, photovoltaic, wind and secondary battery system, PV tracker, monitoring and GUI system with logging function are designed. To verify of performance of hybrid type streetlight for railway station, we have demonstration test to get of generation energy and flow of energy and the results are present in this paper.